Packaged Cooling With Electric Heat And Gas/Electric .

Transcription

Packaged RooftopsPrecedent 3-10 Tons — 60 HzR-22Packaged Cooling (T*C)Packaged Gas/Electric (Y*C)April 2008RT-PRC025-EN

IntroductionPackaged Rooftop Air ConditionersThrough the years, Trane has designed and developed the most complete lineof Packaged Rooftop products available in the market today. Trane was thefirst to introduce the Micro—microelectronic unit controls—and has continuedto improve and revolutionize this design concept.Electromechanical controls are available for simpler applications, and for themore sophisticated, ReliaTel microprocessor controls.The ReliaTel control platform offers the same great features and functionalityas the original Micro, with additional benefits for greater application flexibility.With its sleek, compact cabinet, rounded corners and beveled top Precedentcontinues to provide the highest standards in quality and reliability, comfort,ease of service, and the performance of Trane light commercial products.Trane customers demand products that provide exceptional reliability, meetstringent performance requirements, and are competitively priced. Tranedelivers with Precedent.Precedent features cutting edge technologies: reliable compressors, Traneengineered ReliaTel controls, computer-aided run testing, and IntegratedComfort Systems. So, whether you’re the contractor, the engineer, or theowner you can be certain Precedent Products are built to meet your needs.It’s Hard To Stop A Trane. Packaged CoolingPackaged Gas/Electric 2008 Trane All rights reservedRT-PRC025-EN

Table of ContentsIntroduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2Standard Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4Other Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4Features and Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4Standard Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5Variety of Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6Other Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8Application Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Selection Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12Model Number Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14General Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16Performance Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .106ReliaTel Controlled Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .106Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .108Jobsite Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118Dimensional Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119Weights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .127Mechanical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .129Factory Installed Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .130Factory or Field Installed Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .131Field Installed Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .132RT-PRC025-EN3

Features and BenefitsStandard Features 1” throwaway filters providedon 3-5 ton units 2” throwaway filters providedon 6-10 ton units 5-year Limited CompressorWarranty 5-year Limited Heat ExchangerWarrantyTrane built Scroll Compressorson all 3-10 ton units except 3 tonStandard Efficiency Model(Reciprocating Compressor)CO2 Sensing Digital Display Zone SensorFactory Installed Options Dual Thermistor Remote ZoneSensor High Altitude Kit High Static Drive Humidity Sensor LP Conversion Kit Manual Outside Air Damper Motorized Outside Air Dampers Powered Exhaust Quick Adapt Curbs Quick Start Kit Belt Drive Motors (3-5 tons) Black Epoxy Pre-Coated Coils CompleteCoat Condenser Coil Anti-Short Cycle Timer(Standard with ReliaTel ) Dehumidification Option High Pressure Cutout Colored and Numbered Wiring Convertible Airflow Direct Drive Motors (3-5 tons) Easy Access Low VoltageTerminal Board (LTB) Electromechanical or ReliaTelMicroprocessor Controls Foil-Faced and Edge CapturedInsulation IAQ Dual Sloped and RemovableDrain Pans Liquid Line Refrigerant Drier Low Ambient Cooling to 0 F onMicroprocessor Models Low Ambient Cooling to 40 F onElectromechanical Models Operating Charge of R-22 Patented Hybrid Condenser Coilfor easy cleaning Phase Reversal Protection (3-5ton units with direct drive indoormotor)Progressive Tubular AluminizedSteel Heat ExchangerProvisions for Through-the-BaseGas and Condensate DrainConnections Quick Access Panels Quick Adjust Fan MotorMounting Plate Single Point Power Single Side Service Standardized Components4Field Installed Options 1-year Limited Parts WarrantyBelt Drive Motors (6-10 tons)Trane Communications Interface(TCI)Options* Hinged Access Doors Novar Return Air Sensor Novar Unit Controls Powered or UnpoweredConvenience Outlet Stainless Steel Heat Exchangerwith 10-year warranty Remote Potentiometer Roof Curb Supply and/or Return Air SmokeDetector Thermostat Ventilation Override Accessory Zone Sensor Thermal Expansion Valve Through the Base ElectricalAccess Through the Base Electrical withCircuit Breaker Through the Base Electrical withDisconnect Switch 2” Pleated FiltersFactory or Field Installed Options Barometric Relief Clogged Filter/Fan Failure Switch Crankcase Heaters Discharge Air Sensing Kit Economizer Electric Heaters Frostat LonTalk CommunicationsInterface (LCI) Oversized Motors Reference or ComparativeEnthalpy Tool-less Hail Guards*Refer to Model Number Descriptionfor option availability.Other Benefits Cabinet design ensures waterintegrity Ease of Service, Installation andMaintenance Mixed model build enables“fastest in the industry” shipcycle times Outstanding Airflow Distribution ReliaTel Controls Unmatched Product Support isone of our finest assets. TraneSales Representatives are aSupport Group that can assistyou –Special ApplicationsRT-PRC025-EN

Features and Benefits–Specifications–Computer Programs andmuch moreStandard FeaturesAnti-Short Cycle Timer (Standardwith ReliaTel)Provides a 3 minute minimum “ON”time and 3 minute “OFF” time forcompressors to enhance compressorreliability by assuring proper oilreturn.Colored And Numbered WiringSave time and money tracing wiresand diagnosing the unit.CompressorsPrecedentcontains the bestcompressortechnologyavailable toachieve thehighest possibleperformance. Ourcompressor lineincludes Tranebuilt ClimaTuff reciprocating and scrolls.Benefits” section within the Featuresand Benefits section of this catalog.Easy Access Low VoltageTerminal BoardFor the simpler job that does notrequire a building automationsystem, or expanded diagnosticscapabilities, Precedent offerselectromechanical controls. This 24volt control includes the controltransformer and contactor pressurelugs for power wiring.Precedent’s LowVoltage TerminalBoard is externalto the electricalcontrol cabinet. Itis extremely easyto locate andattach thethermostat wireand testoperation of allunit functions.This is another cost and time savinginstallation feature.Convertible UnitsThe units ship in a downflowconfiguration. They can be easilyconverted to horizontal by simplymoving two panels.Units come complete with horizontalduct flanges so the contractordoesn’t have to field fabricate them.These duct flanges are a time andcost saver.CoolingPrecedent boasts a patent-pending1 1 1 condenser coil, permanentlygapped for easy cleaning.Standard or High Efficiency Coolingavailable.Dual Sloped Drain PansReliaTel microprocessor controlsprovide unit control for heating,cooling and ventilating utilizing inputfrom sensors that measure indoorand outdoor temperature and otherzone sensors. ReliaTel also providesoutputs for building automationsystems and expanded diagnostics.For a complete list of ReliaTelofferings, refer to the “OtherRT-PRC025-ENAll panels in theevaporatorsection of theunit havecleanable foilfaced insulation.All edges areeither captured orsealed to ensureno insulationfibers get into theairstream.Heat ExchangerCondenser CoilControls – ReliaTel orElectromechanicalFoil Faced InsulationEvery Precedentunit has a noncorrosive,removable,double-slopeddrain pan that’seasy to clean andreversible toallow installationof drain trap oneither side of theunit.The compact cabinet features aprogressive tubular heat exchangerin low, medium and high heatcapacities.The heat exchanger is fabricatedusing stainless steel burners andcorrosion-resistant aluminized steeltubes as standard on all models. Ithas an induced draft blower to pullthe gas mixture through the burnertubes. The heater has a direct sparkignition system which doubles as asafety device to prove the flame.Gas/Electric Precedent modelsexceed all California seasonalefficiency requirements. They alsoperform better than required to meetthe California NOx emissionrequirements.Low Ambient CoolingAll Precedent microprocessor unitshave cooling capabilities down to 0 Fas standard. Electromechanicalmodels have cooling capabilities to40 F as built, or to 0 F by adding theoptional low ambient control(frostat).5

Features and BenefitsLow Voltage ConnectionsThe wiring of the low voltageconnections to the unit and the zonesensors is as simple as 1-1, 2-2, and3-3. This simplified system makes iteasy for the installer to wire.Due to standardized componentsthroughout the Precedent line,contractors/owners can stock fewerparts.Through the Base CondensateEvery unit includes provisions forthrough the base condensate drainconnections. This allows the drain tobe connected through the roof curbinstead of a roof penetration.MotorsBelt or direct drive – standard oroversized supply fan motors meet awide airflow range.Phase Reversal Protection1Phase Monitor shall provide 100%protection for motors andcompressor against problems causedby phase loss, phase imbalance andphase reversal. Phase monitor isequipped with an LED that providesand ON or FAULT indicator.Remove two screws for access to thestandardized internal componentsand wiring.Dehumidification (Hot GasReheat) OptionFactory Installed OptionsThis optionallows forincreasedoutdoor airventilation.It reduceshumiditylevels whileincreasingcomfortlevel in the air space. Cooling canoperate without a demand fordehumidification. The hot gas reheatcoil is designed to deliver maximumreheat temperatures and pivot toallow for easy access cleaning.Belt Drive Motors (3-5 tons)For additionalstaticrequirements,Precedent 3-5ton units offeran optionalbelt drivemotor to meeta wide range ofairflow needs.The pre-coated coils are aneconomical option for protection inmildly corrosive environments.CompleteCoat Condenser CoilQuick-Adjust Idler ArmWith the Quick-Adjust Idler Arm, thebelt and sheaves can be quicklyadjusted without moving themounted fan motor. The result is amajor savings in time and money.Codes require a method of assuredunit shutdown for servicing. Fieldinstalled disconnects sometimesinterfere with service access. Factoryinstallation of unit disconnectsreduces costs, assures propermounting and provides theopportunity to upgrade to unit circuitbreaker protection.Variety of Options*Black Epoxy Pre-Coated CoilsQuick-Access Panelsprovisions for through the baseelectrical connections are available.These coils provide excellentcorrosion resistance as well asuniformity of coverage and coatingthickness.Circuit Breaker (Required withThrough- the-Base Electrical)High Pressure CutoutThis factory-installed option isoffered for units that do not haveHigh Pressure Cutout as standard. All3-phase units with scrollcompressors include High Pressurecutout as standard.Hinged Access DoorsSingle side service is standard on allunits.These doors permiteasy access to thefilter, fan/heat, andcompressor/controlsections. Theyreduce the potentialroof damage fromscrews or sharpaccess doorcorners.Standardized ComponentsNovar Unit ControlsComponents are placed in the samelocation on all Precedent units.Familiarize yourself with onePrecedent and you are familiar withevery Precedent.Novar 3051 and 2024 are availablefor Precedent Gas and Electric Heatmodels.Single Point PowerA single electrical connection powersthe unit.Single Side Service163-5 ton units with Direct Drive Indoor MotorThis option is a factory installedthermal magnetic, molded case,HACR Circuit Breaker with provisionsfor through the base electricalconnections.Disconnect Switch (Requiredwith Through-the-Base Electrical)Phase MonitorFactory installed 3-pole, moldedcase, disconnect switch withPhase monitor shall provide 100%protection for motors andcompressors against problemsRT-PRC025-EN

Features and Benefitscaused by phase loss, phaseimbalance, and phase reversal.Phase monitor is equipped with anLED that provides an ON or FAULTindicator.*Refer to Model Number Descriptionfor option availability.Powered or UnpoweredConvenience OutletThis option is a GFCI, 120v/15amp, 2plug, convenience outlet, eitherpowered or unpowered. This optioncan only be ordered when Throughthe Base Electrical with either theDisconnect Switch or Circuit Breakeroption is ordered.Stainless Steel Heat ExchangerThe optional stainless steel heatexchanger is constructed of 304stainless steel. It is resistant tocorrosion and oxidation and easy toclean.The high strength to weight ratioallows for high ventilation rates withgas units. It is an excellent option tocompliment the dehumidificationoption as a high outside airventilation unit.With this option, a 10-year stainlesssteel heat exchanger warranty isstandard.Supply and/or Return Air SmokeDetectorWith this optioninstalled, if smoke isdetected, all unitoperation will be shutdown. Reset will bemanual at the unit.Return Air SmokeDetectors requireminimum allowableairflow when used withcertain models.Thermal Expansion ValveThrough-the-Base ElectricalUtility AccessAn electrical serviceentrance shall beprovided allowingelectrical access forboth control andmain powerconnections insidethe curb andthrough the base ofthe unit. Option willallow for fieldinstallation of liquid-tight conduitand an external field installeddisconnect switch.Factoryprovidedthrough thebaseopeningssimplifywiring andpiping.Because these utility openingsfrequently minimize the number ofroof penetrations, the integrity ofroofing materials is enhanced.Two-Inch Pleated Filters2” pleated media filters are offeredas an option on all Precedent unitsfor jobs with enhanced Indoor AirQuality (IAQ) requirements.Factory or Field InstalledOptionsBarometric ReliefDesigned to be used on downflowunits, barometric relief is anunpowered means of relievingexcess building pressure.Clogged Filter/Fan Failure SwitchA dedicated differential pressureswitch is available to achieve activefan failure indication and/or cloggedfilter indication.These sensors allow a zone sensorservice light or Integrated ComfortSystem to indicate a dirty filter or afan that’s not working. The fieldinstallation charges for thesevaluable feedback devices ofteneliminate them from consideration.Factory installation can make suchfeatures a good investment.Crankcase HeatersThese band or insertion heatersprovide improved compressorreliability by warming the oil toprevent migration during off-cyclesor low ambient conditions.Discharge Air Sensing KitProvides true discharge air sensing inheating models. The kit is functionalonly with the ReliaTel OptionsModule.Electric HeatersElectric heat modules are availablewithin the basic unit. If ordering theThrough the Base Electrical optionwith an Electrical Heater, the heatermust be factory installed.Fresh Air Options – Dampers andEconomizer0 - 25% manual or 0 - 50% motorizedoutside air hoods are available.Economizers are equipped witheither dry bulb or reference orcomparative enthalpy sensing.These economizers provide freecooling as the outdoor temperatureand/or humidity decreases. Correctlyinstalled, they offer a valuable energysavings. Factory-installedeconomizers save time and ensureproper installation.The economizers come with threecontrol options — dry bulb isstandard, enthalpy and differentialenthalpy are optional.FrostatThis capillary bulb embedded in theface of the evaporator coil monitorscoil temperature to preventevaporator icing and protect thecompressor. Recommended forapplications with low leaving airtemperatures, low airflow and orhigh latent load applications.LonTalk CommunicationsInterfaceThe LonTalk communicationsinterface allows the unit tocommunicate as a Tracer LCI-Vdevice or directly with genericLonTalkNetwork Building AutomationSystem Controls.Available for a wider range ofapplications.RT-PRC025-EN7

Features and BenefitsOversized MotorsFactory or field installed oversizedmotors available for high staticapplications.Reference or ComparativeEnthalpyMeasures and communicateshumidity while maximizing comfortcontrol.Tool-less Hail GuardsTool-less, hail protection quality coilguards shall be either factory or fieldinstalled for condenser coilprotection. This option protects thecondenser coil from vandalism and/or hail damage.Dual Thermistor Remote ZoneSensorThis sensor will reduce the totalnumber of remote sensors to obtainspace temperature averaging. Thissensor should be utilized withReliaTel controls.High Altitude KitPreviously a Canadian Agencyrequirement for units applied about2000 feet, it is not required by theU.S. Domestic contractors shouldconsult with local authority on bestpractice. Devates gas orifices by 10%.High Static DriveAvailable on many models, this highstatic drive accessory extends thecapability of the standard motor.Avoid expensive motors andoperating costs by installing thisoptimized sheave accessory.Humidity Sensor/HumidistatTrane Communication Interface(TCI)Available factory or field installed.This module when applied with theReliaTel easily interfaces withTrane’s Integrated Comfort System.Field Installed OptionsCO2 SensingThe CO2 sensor has the ability tomonitor space occupancy levelswithin the building by measuring theparts per million of CO2 (CarbonDioxide) in the air. As the CO2 levelsincrease, the outside air dampermodulates to meet the CO2 spaceventilation requirements. The CO2sensor kit is available as a fieldinstalled accessory.Digital Display Zone SensorThe Digital LCD (Liquid CrystalDisplay) zone sensor has the look andfunctionality of standard zonesensors. This sensor should beutilized with ReliaTel controls.8Used in conjunction with ourDehumidification (Hot Gas Reheat)units to provide outstandinghumidity control and comfort.Humidity sensors can be wall or ductmounted and set fo

Through the years, Trane has designed and developed the mo st complete line of Packaged Rooftop products available in the market today. Trane was the first to introduce the Micro—microelect ronic unit controls—and has co