R&S FSH HandheldSpectrum AnalyzerSpecificationsRohde & Schwarz FSH-Z29 SpecsProvided by www.AAATesters.comData Sheet Version 24.00yearFSH dat-sw en 5214-0482-22 v2400 cover.indd 116.01.2018 11:43:05

Version 24.00, January 2018CONTENTSSpecifications . 4Frequency . 4Sweep time. 5Bandwidths . 5Level. 5Trigger functions . 7Inputs and outputs . 8Vector network analysis/vector voltmeter . 10R&S FSH4/R&S FSH8 model .24/.28 with R&S FSH-K42/R&S FSH-K45 option . 10R&S FSH13/R&S FSH20 model .23/.30 with or without option R&S FSH-K45 option . 12Scalar network analysis . 14R&S FSH4/R&S FSH8 model .24/.28 without R&S FSH-K42 option . 14Distance-to-fault analysis . 15R&S FSH4/R&S FSH8/R&S FSH13/R&S FSH20 model .24/.28/.23/.30 with R&S FSH-K41 option . 15R&S FSH-K29 pulse measurements with power sensor . 15R&S FSH-K10 GSM EDGE measurement application. 16R&S FSH-K44 3GPP WCDMA BTS/NodeB pilot channel and pilot EVM measurement applicationR&S FSH-K44E 3GPP WCDMA BTS/NodeB code domain power and EVM measurement applicationwith HSDPA/HSPA analyzer . 17R&S FSH-K46 CDMA2000 BTS pilot channel and EVM measurement applicationR&S FSH-K46E CDMA2000 BTS code domain power measurement application . 19R&S FSH-K47 1xEV-DO BTS pilot channel and EVM measurement applicationR&S FSH-K47E 1xEV-DO BTS PN scanner and time domain power measurement application . 21R&S FSH-K48 3GPP TD-SCDMA BTS power and P-CCPCH EVM measurement applicationR&S FSH-K48E 3GPP TD-SCDMA/HSDPA BTS code domain power and EVM measurement application . 22R&S FSH-K50/R&S FSH-K51 LTE FDD/TDD downlink pilot channel and EVM measurement applicationR&S FSH-K50E/R&S FSH-K51E LTE FDD/TDD downlink extended channel and modulation measurement application . 24R&S FSH-K56 NB-IoT measurement application (for FDD LTE) . 25R&S FSH-K43 receiver mode and channel scan measurement application . 26General data. 27Equivalence of specifications for different R&S FSH part numbers. 28Accessories . 29R&S FSH-Z14 directional power sensor . 29R&S FSH-Z44 directional power sensor . 31R&S HA-Z240 GPS receiver . 32R&S FSH-Z114 precision frequency reference . 32Ordering information . 33Options . 33Accessories . 34R&S NRP-Zxx power sensors supported by the R&S FSH4/8/13/20 . 35R&S Thermal Power Sensors . 36Optical Power Sensors and accessories . 36Recommended extras: directional antenna and accessories . 36Warranty . 362Rohde & Schwarz R&S FSH Handheld Spectrum Analyzer

Version 24.00, January 20188SpecificationsSpecifications apply under the following conditions:15 minutes warm-up time at ambient temperature, specified environmental conditions met, calibration cycle adhered to.Data without tolerances: typical values only. Data designated as “nominal” applies to design parameters and is not tested.Data without tolerance limits is not binding.FrequencyFrequency rangeR&S FSH4 model .04/.14R&S FSH8 model .08/.18R&S FSH4 model .24R&S FSH8 model .28R&S FSH13 model .13/.23R&S FSH20 model .20/.30Frequency resolutionReference frequency, internalAging per yearTemperature driftAchievable initial calibration accuracyTotal reference uncertainty0 C to 50 C 1Reference uncertainty 20 C to 30 CReference frequency, with R&S HA-Z240 GPS receiver optionFrequency uncertaintyGPS on, 1 minute after satellite lockup to 30 minutes after losing satellite lockReference frequency, with R&S FSH-Z114 precision frequency reference optionAging per yearTemperature drift0 C to 50 CAchievable initial calibration accuracyTotal reference uncertaintyR&S FSH-Z114 connected 30 seconds after oscillator lock 2 minutes after oscillator lockFrequency readoutMarker resolutionUncertaintyNumber of sweep (trace) pointsMarker tuning frequency step sizeFrequency counter resolutionCount uncertaintyselectableSNR 25 dBFrequency spanSpan uncertaintySpectral purity SSB phase noiseCarrier offset130 kHz100 kHz1 MHz9 kHz to 3.6 GHz9 kHz to 8 GHz100 kHz to 3.6 GHz100 kHz to 8 GHz9 kHz to 13.6 GHz9 kHz to 20 GHz1 Hz1 10–61 10–65 10–7(time since last adjustment aging rate) temperature drift calibration accuracy 2 10–6 aging, typ. 1 10–6 aging 2.5 10–8 5 10–83.6 10–94 10–101 10–9(time since last adjustment aging rate) temperature drift 3 calibration accuracy(nominal)(time since last adjustment aging rate) temperature drift calibration accuracy0.1 Hz (marker frequency referenceuncertainty 10 % resolution bandwidth ½ (span/(sweep points – 1) 1 Hz)631span/6300.1 Hz (low), 0.1 mHz (high) (frequency reference uncertainty ½ (last digit))0 Hz, 10 Hz to 3.6/8/13.6/20 GHznominal 1 %f 500 MHz –95 dBc (1 Hz), typ. –105 dBc (1 Hz) –100 dBc (1 Hz), typ. –110 dBc (1 Hz) –120 dBc (1 Hz), typ. –127 dBc (1 Hz)For serial number 115000: 30 C to 50 C: 3 10–6.Rohde & Schwarz R&S FSH Handheld Spectrum Analyzer3

Version 24.00, January 2018Sweep timeSweep timeUncertaintyspan 0 Hz10 Hz span 600 MHzspan 600 MHzspan 0 Hzspan 10 Hz100 µs to 1000 s20 ms to 1000 s20 ms span/600 MHz to 1000 snominal 1 %nominal 3 %–3 dB bandwidthzero span 21 Hz RBW 300 kHzRBW 300 kHz1 Hz to 3 MHz in 1/3 sequence10 MHz, 20 MHz additionallynominal 5 %nominal 10 %nominal 5 (Gaussian type filters)–3 dB bandwidthzero span 21 Hz to 3 MHz in 1/3 sequence10 MHz additionallyBandwidthsResolution bandwidthsRangeBandwidth accuracySelectivity 60 dB:3 dBVideo filtersRangeLevelDisplay rangedisplayed noise floor to 30 dBmMaximum rated input level with RF attenuation 10 dBDC voltageR&S FSH4/ R&S FSH 8,80 Vmodel .04/.08/.14/.18R&S FSH4/ R&S FSH 8, model .24/.28,50 VR&S FSH13, R&S FSH 20CW RF power30 dBm ( 1 W)Peak RF powerduration 3 s33 dBm ( 2 W)Max. pulse voltage150 VMax. pulse energypulse width 10 µs10 mWsMaximum rated input level with RF attenuation 10 dBDC voltage50 VCW RF power20 dBm ( 100 mW)Peak RF powerduration 3 s23 dBm ( 200 mW)Max. pulse voltage50 VMax. pulse energypulse width 10 µs1 mWsIntermodulationThird-order intercept (TOI),intermodulation-free dynamic range, signal level 2 –20 dBm, RF attenuation 0 dB,nominal valuesRF preamplifier offfin 300 MHz 54 dBc (TOI 7 dBm, typ. 11 dBm)300 MHz fin 3.6 GHz 60 dBc (TOI 10 dBm, typ. 15 dBm)3.6 GHz fin 20 GHz 46 dBc (TOI 3 dBm, typ. 10 dBm)intermodulation-free dynamic range, signal level 2 –40 dBm, RF attenuation 0 dB,RF preamplifier onfin 300 MHz 50 dBc (TOI –15 dBm)300 MHz fin 20 GHz 56 dBc (TOI –12 dBm)Second harmonic intercept (SHI),RF attenuation 0 dB, RF preamplifier offnominal valuesfin 20 MHz to 1.5 GHz 40 dBmfin 1.5 GHz to 3 GHz 30 dBmfin 3 GHz to 4 GHz 20 dBmfin 4 GHz to 10 GHz 60 dBmRF attenuation 0 dB, RF preamplifier onfin 100 MHz to 4 GHz0 dBm24Requires instrument with serial number 105000.Rohde & Schwarz R&S FSH Handheld Spectrum Analyzer

Version 24.00, January 20188Displayed average noise level0 dB RF attenuation, termination 50 Ω, RBW 100 Hz, VBW 10 Hz,sample detector, log scaling, tracking generator off, normalized to 1 Hzfrequencypreamplifier off9 kHz to 100 kHzR&S FSH4, R&S FSH8 –108 dBm, typ. –118 dBm(models .04/.14/.08/.18 only)R&S FSH13, R&S FSH20 –96 dBm, typ. –106 dBm100 kHz to 1 MHz –115 dBm, typ. –125 dBm1 MHz to 10 MHz –136 dBm, typ. –144 dBm10 MHz to 2 GHz –141 dBm, typ. –146 dBm2 GHz to 3.6 GHz –138 dBm, typ. –143 dBm3.6 GHz to 5 GHz –142 dBm, typ. –146 dBm5 GHz to 6.5 GHz –140 dBm, typ. –144 dBm6.5 GHz to 13.6 GHz –136 dBm, typ. –141 dBm13.6 GHz to 18 GHz –134 dBm, typ. –139 dBm18 GHz to 20 GHz –130 dBm, typ. –135 dBmfrequencypreamplifier on100 kHz to 1 MHz –133 dBm, typ. –143 dBm1 MHz to 10 MHzR&S FSH4, R&S FSH8 –157 dBm, typ. –161 dBmR&S FSH13, R&S FSH20 –155 dBm, typ. –159 dBm10 MHz to 1 GHz –161 dBm, typ. –165 dBm1 GHz to 2 GHz –159 dBm, typ. –163 dBm2 GHz to 5 GHz –155 dBm, typ. –159 dBm5 GHz to 6.5 GHz –151 dBm, typ. –155 dBm6.5 GHz to 8 GHz –147 dBm, typ. –150 dBm8 GHz to 13.6 GHz –158 dBm, typ. –162 dBm13.6 GHz to 18 GHz –155 dBm, typ. –160 dBm18 GHz to 20 GHz –150 dBm, typ. –155 dBmAdjacent channel leakage power ratio (ACLR)Dynamic rangefrequency 3.6 GHz, total power –20 dBm3GPP WCDMAadjacent channelnominal 55 dBalternate channelnominal 58 dBCDMA2000 adjacent channelnominal 58 dBalternate channelnominal 61 dBImmunity to interference, nominal valuesImage frequenciesR&S FSH4/R&S FSH8, serial number 105000fin – 2 21.4 MHz –70 dBc, typ. –80 dBcfin – 2 831.4 MHz –70 dBc, typ. –90 dBcfin – 2 4881 MHz–60 dBcR&S FSH4/R&S FSH8, serial number 105000, R&S FSH13, R&S FSH20fin – 2 54.4 MHz –70 dBc, typ. –80 dBcfin – 2 860.8 MHz –70 dBc, typ. –90 dBcfin – 2 4892.8 MHz–60 dBcR&S FSH13, R&S FSH20fin 2 6342.4 MHz–60 dBcfin – 2 6342.4 MHz–60 dBcIntermediate frequenciesR&S FSH4/R&S FSH8, serial number 10500021.4 MHz, 831.4 MHz, 4881.4 MHz –60 dBc, typ. –80 dBc8931.4 MHz–50 dBcR&S FSH4/R&S FSH8, serial number 105000, R&S FSH13, R&S FSH2054.4 MHz, 860.8 MHz, 4892.8 MHz –60 dBc, typ. –80 dBc8924.8 MHz–50 dBcR&S FSH13, R&S FSH203171.2 MHz–50 dBcRohde & Schwarz R&S FSH Handheld Spectrum Analyzer5

Version 24.00, January 2018Other interfering signals,signal level – RF attenuation –20 dBmOther interfering signals, related to localoscillatorsResidual spurious responseR&S FSH4/R&S FSH8, serial number 105000f 3.6 GHz, –60 dBcspurious at fin – 2440.7 MHz3.6 GHz f 8 GHz, –60 dBcspurious at fin – 4465.7 MHzR&S FSH4/R&S FSH8, serial number 105000, R&S FSH13, R&S FSH20f 3.6 GHz, –60 dBcspurious at fin – 2446.4 MHz3.6 GHz f 8 GHz, –60 dBcspurious at fin – 4462.4 MHz8 GHz f 20 GHz, –60 dBcf 3.6 GHz f 300 kHz–60 dBc f 300 kHz –60 dBcf 3.6 GHz f 300 kHz–54 dBc f 300 kHz –54 dBcf receive frequencyinput matched with 50 Ω, –90 dBmwithout input signal, RBW 30 kHz,f 3 MHz, RF attenuation 0 dB,tracking generator offLevel displayLogarithmic level axisLinear level axisNumber of tracesTrace detectors1/2/5/10/20/50/100/150 dB, 10 divisions0 % to 100 %, 10 divisions2max. peak, min. peak, auto peak, sample,RMSclear/write, max. hold, min. hold, average,view–200 dBm to 30 dBmdBm, dBmV, dBµV, V, WTrace functionsSetting range of reference levelUnits of level axisLevel measurement uncertaintyAbsolute level uncertainty at 100 MHzFrequency response ( 20 C to 30 C)Attenuator uncertaintyUncertainty of reference level settingDisplay nonlinearityBandwidth switching uncertaintyTotal measurement uncertainty 20 C to 30 C9 kHz f 100 kHz(models .04/.14/.08/.18 only)100 kHz f 10 MHz10 MHz f 3.6 GHz3.6 GHz f 20 GHz 0.3 dBnominal 1.5 dBnominal 1.5 dB 1 dB 1.5 dB 0.3 dBnominal 0.1 dB 0.2 dBSNR 16 dB, 0 dB to –50 dB,logarithmic level displayreference: RBW 10 kHznominal 0.1 dB95 % confidence level, 20 C to 30 C,SNR 16 dB, 0 dB to –50 dB below reference level, RF attenuation auto10 MHz f 3.6 GHz 1 dB, typ. 0.5 dB3.6 GHz f 20 GHz 1.5 dB, typ. 1 dBTrigger functionsTriggerTrigger sourceInternal periodic trigger, cycle frequencyExternal trigger level thresholdserial number 121000serial number 121000low high transitionhigh low transitionGated triggerGate sourceGate delayGate length6Rohde & Schwarz R&S FSH Handheld Spectrum Analyzerfree run, video, externalinternal periodic trigger additionally1 Hz to 1 MHz, min. resolution 1 Hz2.4 V0.7 Vexternal10 µs to 100 s, min. resolution 10 µs(or 1 % of delay)10 µs to 100 s, min. resolution 10 µs(or 1 % of gate length)

Version 24.00, January 20188Inputs and outputsRF inputImpedanceConnectorVSWR100 kHz f 1 GHz1 GHz f 6 GHz6 GHz f 20 GHzRF input only50 ΩN femalenominal 1.5nominal 2nominal 30 dB to 40 dB in 5 dB stepsInput attenuatorAF outputAF demodulation typesAM and FMConnector3.5 mm mini jackOutput impedancenominal 32 ΩVoltage (open circuit)VRMS adjustable from 0 V to 100 mVPower sensorConnector7-contact female (type Binder 712)Power sensors supportedsee accessoriesTracking generator (models .14/.18/.23/.24/.28/.30 only)Frequency rangemodels .14/.24100 kHz to 3.6 GHzmodels .18/.23/.28/.30100 kHz to 8 GHzConnectorN female, 50 ΩVSWR100 kHz f 1 GHznominal 1.51 GHz f 6 GHznominal 26 GHz f 8 GHz, models .18 and .28nominal 3Output leveltracking generator attenuation 0 dBnominal 0 dBmTracking generator attenuator0 dB to 40 dB in 1 dB stepsDynamic range for isolationRF attenuation 0 dB, tracking generator attenuation 10 dB, RBW 1 kHzmeasurements100 kHz f 300 kHz 60 dB, typ. 80 dB300 kHz f 6 GHz 70 dB, typ. 90 dB6 GHz f 8 GHz, models .18 and .28 typ. 50 dBReverse powerDC voltage50 VCW RF power 20 dBm ( 0.1 W)Max. pulse voltage50 VMax. pulse energy (10 µs)1 mWsExternal reference, external trigger, DC bias port 2 (BNC 1)ConnectorBNC, 50 ΩModeselectable,ext. reference, ext. trigger, DC bias port 2R&S FSH4/R&S FSH8, models .24/.28selectable,ext. reference, ext. triggerR&S FSH4/R&S FSH8, other models,R&S FSH13, R&S FSH20External referencerequired level0 dBmfrequency10 MHzExternal trigger thresholdlow high transition2.4 Vhigh low transition0.7 VDC bias port 2max. rated input voltage50 Vmax. rated input current600 mARohde & Schwarz R&S FSH Handheld Spectrum Analyzer7

Version 24.00, January 2018IF out, DC bias port 1 (BNC 2)ConnectorModeIF out frequencyDC bias port 1Internal DC bias 3Output portOutput voltageMaximum output powerMaximum continuous output current38selectable,R&S FSH4/R&S FSH8, models .24/.28R&S FSH4/R&S FSH8,models .04/.14/.08/.18,R&S FSH13, R&S FSH20R&S FSH4/R&S FSH8,serial number 105000R&S FSH4/8, serial number 105000,R&S FSH13, R&S FSH20max. rated input voltagemax. rated input currentselectableoperated with batteryoperated with AC mainsmode: internalBNC, 50 ΩIF out, DC bias port 1IF out21.4 MHz54.4 MHz50 V600 mAport 1 or 2 12 V to 32 V in 1 V steps4W10 W500 mAInternal DC bias is available by instruments with serial number 106292 (model .24) or serial number 106623 (model .28).Rohde & Schwarz R&S FSH Handheld Spectrum Analyzer

Version 24.00, January 20188Vector network analysis/vector voltmeterR&S FSH4/R&S FSH8 model .24/.28 with R&S FSH-K42/R&S FSH-K45 optionR&S FSH4 model .24R&S FSH8 model .28Frequency rangeFrequency resolutionData pointsPort power300 kHz to 3.6 GHz300 kHz to 8 GHz1 Hz631nominal 0 dBm to –40 dBm in 1 dB stepscontrolled via tracking generatorattenuationReflection measurementResult formatsmeasurement mode vectormagnitude, phase, magnitude phase,VSWR, reflection coefficient, Smith chart,cable loss, group delay, electrical lengthmagnitude phase, Smith chartmeasurement mode vector voltmeterReturn lossRangeResolutionMeasurement uncertaintyselectableOne-port phaseRangeResolutionMeasurement uncertainty1/2/5/10/20/50/100 dB, linear 100 %0.01 dBsee figure Uncertainty of reflectionmeasurement R&S FSH4/R&S FSH8 withthe R&S FSH-K42/ R&S FSH-K45 optionselectable90/180/360/1000 to 10000 in 1/2/5 steps0.01 specifications are based on a matched DUT, RBW 100 Hz, RF attenuation 10 dB,nominal source power 0 dBm, 20 C to 30 C300 kHz f 3.6 GHz0 dB return loss 15 dBnominal 3 15 dB return loss 25 dBnominal 6 25 dB return loss 35 dBnominal 20 3.6 GHz f 8 GHz (R&S FSH8 only)0 dB return loss 15 dBnominal 3 15 dB return loss 25 dBnominal 6 25 dB return loss 35 dBnominal 20 VSWRRangeSmith chartRangeReflection coefficientmRhoCorrected directivityselectable1 to 1.1, 1.5, 2, 6, 11, 21 or 711, zoom 2, 4, 8range300 kHz f 3 GHz3 GHz f 6 GHz6 GHz f 8 GHz300 kHz f 3 GHz3 GHz f 6 GHz6 GHz f 8 GHzCorrected test port match1 to 1000 in 1, 2, 5 stepstyp. 46 dBtyp. 43 dBtyp. 36 dBtyp. 30 dBtyp. 25 dBtyp. 21 dBUncertainty of reflection measurement with R&S FSH-K42/-K45 option3Measurement uncertainty / dB21300 kHz f 3 GHz3 GHz f 6 GHz06 GHz f 8 GHz-1-2-3051015202530Return Loss / dBUncertainty of reflection measurement R&S FSH4/R&S FSH8 with the R&S FSH-K42/R&S FSH-K45 option.Rohde & Schwarz R&S FSH Handheld Spectrum Analyzer9

Version 24.00, January 2018Transmission measurementResult formatsmeasurement mode vectormeasurement mode vector voltmeter(requires R&S FSH-K45)GainMeasurement rangeDisplay rangeResolutionMeasurement uncertaintyselectablecalibration method full two port highaccuracyPhaseRangeResolutionMeasurement uncertainty–120 dB to 80 dB1/2/5/10/20/50/100 dB, linear 100 %0.01 dBsee figure Transmission magnitudeuncertainty R&S FSH4/R&S FSH8selectableDynamic range from port 1 to port 2Dynamic range from port 2 to port 1Test port matchmagnitude, phase, magnitude phase,group delay, electrical lengthmagnitude phase90/180/360/1000 to 10000 in 1/2/5 steps0.01 specifications are based on a matched DUT, RBW 100 Hz, RF attenuation 10 dB,nominal source power 0 dBm, 20 C to 30 C300 kHz f 50 MHz0 dB insertion loss 40 dBnominal 2 50 MHz f 3.6 GHz0 dB insertion loss 50 dBnominal 2 50 dB insertion loss 70 dBnominal 3 3.6 GHz f 6 GHz (R&S FSH8 only)0 dB insertion loss 50 dBnominal 2 50 dB insertion loss 70 dBnominal 3 6 GHz f 8 GHz (R&S FSH8 only)0 dB insertion loss 50 dBnominal 3 50 dB insertion loss 70 dBnominal 5 RF attenuation 0 dB, tracking generator attenuation 10 dB, RBW 1 kHz100 kHz f 300 kHztyp. 70 dB300 kHz f 6 GHz 70 dB, typ. 90 dB6 GHz f 8 GHztyp. 50 dBRF attenuation 0 dB, tracking generator attenuation 10 dB, RBW 1 kHz100 kHz f 300 kHztyp. 80 dB300 kHz f 6 GHz 80 dB, typ. 100 dB6 GHz f 8 GHztyp. 60 dBas specified for tracking generatoroutput/RF inputTransmissionmagnitude uncertaintyR&S FSH4/R&S FSH8Transmissionmagnitude ,IF bandwidthbandwidth hAccuracy”,f f 1GHz,1 GHz, IF 100 HzUncertainty in dB10.0001.0000.1000.010-80-60-40-200DUT transmission magnitude, S21 or S12 , in dBTransmission magnitude uncertainty R&S FSH4/R&S FSH8 with the R&S FSH-K42/R&S FSH-K45 option.10Rohde & Schwarz R&S FSH Handheld Spectrum Analyzer

Version 24.00, January 20188R&S FSH13/R&S FSH20 model .23/.30 with or without option R&S FSH-K45 option 4Frequency rangeFrequency resolutionData pointsPort power100 kHz to 8 GHz1 Hz631nominal 0 dBm to –40 dBm in 1 dB stepscontrolled via tracking generatorattenuationReflection measurementResult formatsmeasurement mode vectormagnitude, phase, magnitude phase,VSWR, reflection coefficient, Smith chart,cable loss, group delay, electrical lengthmagnitude phase, Smith chartmeasurement mode vector voltmeter(requires R&S FSH-K45)Return lossInputRangeResolutionMeasurement uncertaintyRF port 21/2/5/10/20/50/100 dB, linear 100 %0.01 dBsee figure Uncertainty of reflectionmeasurement with the R&S FSH13model .23/R&S FSH20 model .30selectableOne-port phaseRangeResolutionMeasurement uncertaintyselectable90/180/360/1000 to 10000 in 1/2/5 steps0.01 specifications are based on a matched DUT, RBW 100 Hz, RF attenuation 10 dB,nominal source power 0 dBm, 20 C to 30 C300 kHz f 3.6 GHz0 dB return loss 15 dBnominal 3 15 dB return loss 25 dBnominal 6 25 dB return loss 35 dBnominal 20 3.6 GHz f 8 GHz (R&S FSH8 only)0 dB return loss 15 dBnominal 3 15 dB return loss 25 dBnominal 6 25 dB return loss 35 dBnominal 20 VSWRRangeSmith chartRangeReflection coefficientmRhoCorrected directivityselectable1 to 1.1, 1.5, 2, 6, 11, 21 or 711, zoom 2, 4, 8range1 to 1000 in 1, 2, 5 steps300 kHz f 3 GHztyp. 46 dB3 GHz f 6 GHztyp. 43 dB6 GHz f 8 GHztyp. 36 dB300 kHz f 3 GHztyp. 30 dB3 GHz f 6 GHztyp. 25 dBUncertaintyof reflectionwith R&S FSH-K42/-K45 typ.option6 GHz f 8measurementGHz21 dBCorrected test port match3Measurement uncertainty / dB21300 kHz f 3 GHz3 GHz f 6 GHz06 GHz f 8 GHz-1-2-3051015202530Return Loss / dBUncertainty of reflection measurement with the R&S FSH13 model .23/ R&S FSH20 model .30.4R&S FSH13/R&S FSH20 model .23/.30 supports one port reflection and transmission measurements as standard.For vector voltmeter support the R&S FSH-K45 option is needed.Rohde & Schwarz R&S FSH Handheld Spectrum Analyzer11

Version 24.00, January 2018Transmission measurementResult formatsmeasurement mode vectormeasurement mode vector voltmeter(requires R&S FSH-K45)GainMeasurement rangeDisplay rangeResolutionMeasurement uncertaintyselectablecalibration method "Reflection port 2 transmission reverse"PhaseRangeResolutionMeasurement uncertainty–120 dB to 80 dB1/2/5/10/20/50/100 dB, linear 100 %0.01 dBsee figure Transmission magnitudeuncertainty R&S FSH13/R&S FSH20model .23/.30selectableDynamic range from port 2 to port 1Test port matchmagnitude, phase, magnitude phase,group delay, electrical lengthmagnitude phase90/180/360/1000 to 10000 in 1/2/5 steps0.01 specifications are based on a matched DUT, RBW 100 Hz, RF attenuation 10 dB,nominal source power 0 dBm, 20 C to 30 C300 kHz f 50 MHz0 dB insertion loss 40 dBnominal 2 50 MHz f 3.6 GHz0 dB insertion loss 50 dBnominal 2 50 dB insertion loss 70 dBnominal 3 3.6 GHz f 6 GHz (R&S FSH8 only)0 dB insertion loss 50 dBnominal 2 50 dB insertion loss 70 dBnominal 3 6 GHz f 8 GHz (R&S FSH8 only)0 dB insertion loss 50 dBnominal 3 50 dB insertion loss 70 dBnominal 5 RF attenuation 0 dB, tracking generator attenuation 10 dB, RBW 1 kHz100 kHz f 300 kHztyp. 80 dB300 kHz f 6 GHz 80 dB, typ. 100 dB6 GHz f 8 GHztyp. 60 dBas specified for tracking generatoroutput/RF input TransmissionTransmissionmagnitude uncertaintyFSH13/R&S FSH20magnitudeR&Suncertaintywith calibrationmethod "FullTwoHigh Accuracy",f 1GHz,bandwidth 100Hzwith calibrationmethod "Reflectionport2 Porttransmissionreverse",f 1 IFGHz,IF bandwidth 100 HzUncertainty in dB10.0001.0000.1000.010-80-60-40-20DUT transmission magnitude, S21 or S12 , in dBDUT transmission magnitude in dBTransmission magnitude uncertainty R&S FSH13/R&S FSH20 model .23/.30.12Rohde & Schwarz R&S FSH Handheld Spectrum Analyzer0

Version 24.00, January 20188Scalar network analysisR&S FSH4/R&S FSH8 model .24/.28 without R&S FSH-K42 option 5R&S FSH4 model .24R&S FSH8 model .28Frequency rangeFrequency resolutionData pointsPort powercontrolled via tracking generatorattenuationReflection measurementResult formatsReturn lossVSWRCorrected directivity (20 to 30 )Corrected test port match (20 to 30 )Transmission measurementResult formatsDynamic range from port 1 to port 2Dynamic range from port 2 to port 1Test port match300 kHz to 3.6 GHz300 kHz to 8 GHz1 Hz631nominal 0 dBm to –40 dBm in 1 dB stepsmagnitude, VSWR, reflection coefficient1/2/5/10/20/50/100 dB, linear 100 %0.01 dB1 to 2, 6, 11, 21 or 71, selectablenominal 25 dBnominal 20 dBnominal 20 dBnominal 15 dBrangeresolutionrange300 kHz f 6 GHz6 GHz f 8 GHz300 kHz f 6 GHz6 GHz f 8 GHzmagnitudeRF attenuation 0 dB, tracking generator attenuation 0 dB, RBW 1 kHz300 kHz f 6 GHz 60 dB, typ. 80 dB6 GHz f 8 GHztyp. 40 dBRF attenuation 0 dB, tracking generator attenuation 0 dB, RBW 1 kHz300 kHz f 6 GHz 70 dB, typ. 90 dB6 GHz f 8 GHztyp. 50 dBas specified for tracking generatoroutput/RF inputUncertainty of reflection measurement without the R&S FSH-K42 option.5R&S FSH13/R&S FSH20 model .23/.30 support vector network analysis only.Rohde & Schwarz R&S FSH Handheld Spectrum Analyzer13

Version 24.00, January 2018Distance-to-fault analysisR&S FSH4/R&S FSH8/R&S FSH13/R&S FSH20 model .24/.28/.23/.30 with R&S FSH-K41 optionReturn lossVSWRReflection coefficientmRhoFault resolution in mMaximum permissible spurious signalInputMaximum cable /100 dB, linear 100 %0.01 dB1 to 1.1, 1.5, 2, 6, 11, 21 or 710.01range1 to 1000 in 1, 2, 5 steps(1.5 108 velocity factor/span)nominal 0 dBmRF port 1 or 2RF port 21500 mRF attenuation 0 dBmodel .24/.28: selectablemodel .23/.30depending on cable lossR&S FSH-K29 pulse measurements with power sensorIn combination with one of the power sensors R&S NRP-Z81, -Z85 or -Z86, the R&S FSH4/8/13/20 supports measurements onpulsed signals 6. The achievable RF performance is documented in the data sheet specifications of the R&S NRP-Z81/-Z85/-Z86power sensors. The list below shows which measurements are supported by the R&S FSH-K29.MeasurementsPulse power parametersPeak powerPulse top powerAverage powerBase powerMinimum powerPositive overshootNegative overshootPulse timing parametersPulse durationPulse periodPulse start/stop timeRise/fall timeDuty cycle6R&S FSH-K29 The R&S NRP-Z8x power sensors are supported by instruments with serial number 105000.For instruments with serial number 121000 the R&S FSH-Z129 adapter cable is needed in addition.14Rohde & Schwarz R&S FSH Handheld Spectrum Analyzer

Version 24.00, January 20188R&S FSH-K10 GSM EDGE measurement applicationThe specifications below apply to the R&S FSH4/8/13/20. They are based on the data sheet specifications of t