Adt safewatch pro custom 3000 manual 2Adt safewatch pro 3000 add user code. Adt safewatch pro 3000en user manual. Manual for adt safewatch pro 3000. Adt safewatch pro 3000 user manual.Use 1321CN in Canada. Type 16 Provides a fire alarm when zone is shorted, but only after alarm verified. 4-13 Touchpad Programming Fields . lobby or foyer) disarmed for access into the other partition. Wire Run Chart For Devices* Drawing AuxPower From The Control (12V & 12V–) Wire TOTAL CURRENT DRAWN BY ALL DEVICES CONNECTED TO A SINGLE WIRE RUN Size 50 mA or less 100 mA 300 mA 500 mA 600 mA #22 900 ft (274m) 450 ft (137m) 150 ft (46m) 90 ft (27m) 75 ft (23m) #20 1400 ft (427m) 700 ft (213m) 240 ft (73m) 140 ft (43m) 120 ft (37m) #18 1500 ft (457m)1100 ft (335m) 350 ft (107m) 220 ft (67m) 170 ft (52m) #16 1500 ft (457m) 1500 ft (457m) 550 ft (168m) 350 ft (107m) 270 ft (82m) *Includes Touchpads, RF Receivers, Zone Expander/Relay Units, 4286 Phone Module and communication device. Type 05 Assign to a zone that contains a foil-protected door or window (such as in a store), Trouble byDay/ or to a zone covering a sensitive area such as a stock room, drug supply room, etc. Relays have two programming menu modes: Use *79 Menu mode to map module addresses and device (output) numbers. Set the radio’s address to “03” following the instructions provided with the radio. Common zone option allows either partition to arm, whileleaving a common area (ex. 3.Connect Phone Module terminals as shown. Provides an instant alarm, with NO audible indication at any touchpad or external sounder, if the zone is faulted when the system is armed in the Away, Stay, or Instant, modes. UL For UL installations and Residential fire installations, refer to the chart below for the correctbattery size required to meet the mandatory standby time. 2-12 Installing a Keyswitch . When correctly positioned, push the lock until it is held securely by its snap tabs. To program pager reporting: 1.Enter the appropriate information in thefollowing data fields *160, *163, *166, *169 Pager Phone Numbers (for pagers 1-4 respectively) *161, *164, *167, *170 Pager Prefix Characters (for pagers 1-4 respectively) *162, *165, *168, *171 Pager Reporting Options by Partition (for pagers 1-4 respectively) 2.Enable Pager Delay, if desired, in field *172 (delays alarm reporting for ALL pagers)3.Make sure appropriate user open/close pager reports are enabled using the user attribute command (master code [8] user no. terminals 600 mA max.)† TOTAL 2-7 3000EN Series: Installation Instructions Hardwire Zones Normally Open Zones/ Normally Open EOLR Zones 1.Connect open circuit devices in parallel across the loop; for EOLRzones, connect the EOLR across the loop wires at the last device. This feature eliminates false alarms due to electrical or physical transients. Touchpads must be set for addresses 16-23 (first touchpad is address 16, which is different from previous controls) and programmed in data fields *190-*196. 2.Use data field program mode to enable touchpadaddresses, assign a partition, enable sound options in fields *190-*196 as shown in the table above. Refer to the instructions included with the AVS-ADT system for installation procedures. 5 20 no. 8-PIN TRIGGER CONNECTOR 1 KEY 3 4 5 6 7 8 17 (RED) (ORANGE) (YELLOW) 18 (GREEN) (BLUE) (PURPLE) (BLACK) OUTPUT 12 AUX. Zones andPartitions The system supports up to 64 zones plus three emergency zones (numbered 95, 96, and 99). BEDROOM BEDROOM LIVING ROOM Install smoke detectors in any room where an alarm control is located, or in any room where alarm Smoke Detectors for Minimum Protection control connections to an AC source or phone lines SmokeDetectors for Additional Protection are made. (70mA alarm) † In UL installations, maximum 6160VADT Voice 60mA Touchpad (190mA alarm) current draw from the Auxiliary Output and the Alarm Output 6270ADT Touch Screen 180mA/220mA†† combined must not exceed (280mA alarm) 600 mA (500 mA max from Auxiliary Output). 3.Position thelock in the hole, making certain that the latch will make contact with the latch bracket when the door is closed. Transmitter Battery Life Batteries in the wireless transmitters may last from 4 to 7 years, depending on the environment, usage, and the specific wireless device being used. Insert the key into the lock. Use *57 Menu mode to define thefunction keys (see Function Key Programming section). Make sure that the board rests on the correct row (see Detail A). Use *56 Menu mode to program the keyswitch zone and assign it zone type 77. YEL WIRE REDWIRE GRNWIRE BLKWIRE TO TOUCHPAD TO TOUCHPAD TO TOUCHPAD TO TOUCHPAD Figure 4. Type 24 Usually assigned toall sensors or contacts on exterior doors and windows where Silent Burglary bells and/or sirens are NOT desired. Since this is a “trouble” zone type, do not use this zone type with relays set to activate upon “alarm.” Type 14 Assigned to any zone with a carbon monoxide detector. 81 Zone List Programming Create Zone Lists for relay/powerlinecarrier zones, chime, night-stay, cross zone and pager zones. SWITCH SWITCH BANK 1 BANK 2 1 OFF 1 ON 2 OFF 2 ON 3 OFF 3 OFF 4 OFF 4 ON 5 OFF 5 ON 6 OFF 6 ON 7 OFF 7 ON 8 ON 8 ON AUXILIARY AUDIO LEVEL ADJUSTMENT TRIM POT UVCM MODULE 29 30 31 32 33 34 5 TRIGGER CONNECTOR

18 ZONE CONTROL OUTPUT TERMINALS 4 5 21 22 23 24 25 GND 12VDC EOL RING TIP RED (R) GREEN (T) GREY (R) BROWN (T) 8 2 5 6 7 BANK 1 2 3 4 SWITCH ON 1 8 5 6 7 BANK 1 2 3 4 SWITCH ON 11 10 9 8 7 6 FALLING VOICE TRIG 5 4 3 GND 2 12VDC IN 1 OPTIONAL MONITORING ZONE CONNECTION (USE ZONE TYPE 81) TOPREMISES HANDSET INCOMING PHONE LINE aav uvcm-003-V0 Figure 15. 3.Connect the receiver's wire harness to the control's touchpad terminals. The phone lines must be in service for the phone module to function, even when accessing the system from an on-premises phone. Event Logging records up to 100 selected events in a history log(control and readout from the log is done via Ademco Compass Downloader software or installer/master code at Touchpad). When using a keyswitch, the zone it is connected to is no longer available for use as a protective zone. USE THE APPROPRIATE CLIPS FOR MOUNTING. floor plan-001-V1 Recommendations For Proper Intrusion ProtectionFor proper intrusion coverage, sensors should be located at every possible point of entry to a home or commercial premises. ( ) wiresmk DETECTOR 4 Figure 7b. Auxiliary Alarm Sends a report to the central station and provides an alarm sound at the touchpad. ULC Note for Canadian Units: In accordance with ULC standards, the RF supervisionperiod for this control is three hours for Fire zones (Zone Types 9 and 16) and 12 hours for all other zone types. 12-1 System Communication. 2-1 Mounting the PC Board Alone (no RFReceiver). Type 23 * Can be used on a zone when an output relay action is desired, but with no No Alarm Response accompanying alarm (e.g., lobby door access). Zones can also be assigned to a common partition, which is an area shared by users of both partitions(such as a lobby in a building). 14-4 Various System Trouble Displays . 4-7 Miscellaneous System Fields. This control will not power-up unless AC power isconnected (will not power-up on battery alone). Sounder Wiring (Supervised) Notes This control complies with NFPA requirements for temporal pulse sounding of fire notification appliances. SUPPLEMENTARY CONTROL TERMINAL STRIP POWER SUPPLY – AUX. Supervised transmitters† send check-in signals to the receiver at 70-90 minuteintervals. E.g., Using output 18 for the trigger, program an output function in *80 Menu mode as: ZT 60, P 0, Action 1, Device 18 NOTE: REFER TO UVCM MODULE INSTRUCTIONS FOR CONNECTIONS TO AUDIO SPEAKERS AND MICROPHONE. 2.a. Insert the top of the circuit board into the slots at the top of the cabinet. Firew/Verification System verifies alarm by resetting smoke detectors after short is detected (removes power 7 seconds for zone 1; 3 seconds for trigger output). In the case of a Monitor Zone short/open, the message, "*ALARM*-24 Hr. Non-Burg. 15-1 System Test. This control does not automatically reset power to 4-wire smoke detector zones, so you must use a relay (e.g., 4204, 4229), or on-board trigger** to reset power (also required for fire verification). Zone types are defined below. Use4204 or 4229 modules. 2.Remove cabinet door, then remove the lock knockout from the door. 2-2 Wiring to Touchpads. The wireless system can identify a true low-battery situation, thus allowing the dealer or user of the system time toarrange a change of battery and maintain protection for that given point within the system. 16-1 SECURITY CONTROL . 13-3 System Operation. SWITCHSWITCH BANK 1 BANK 2 1 OFF 1 ON 2 OFF 2 ON 3 OFF 3 OFF 4 OFF 4 ON 5 OFF 5 ON 6 OFF 6 ON 7 OFF 7 ON 8 ON 8 ON 5 TRIGGER CONNECTOR 18 ZONE EARTH CONTROL OUTPUT GROUND TERMINALS AUXILIARY 4 5 21 22 23 24 25 AUDIO LEVEL ADJUSTMENT GND 12VDC TRIM POT EOL UVCMMODULE 8 2 5 6 7 BANK 1 2 3 4 SWITCH ON 1 8 5 6 7 BANK 1 2 3 4 SWITCH ON RING 34 TIP 33 32 31 30 29 11 10 9 8 7 6 FALLING VOICE TRIG 5 4 3 GND 2 12VDC IN 1 RING TIP OPTIONAL MONITORING ZONE CONNECTION (USE ZONE TYPE 81) 4286 4 3 2 1 RED (R) GREEN (T) GREY (R) RJ31X BROWN (T) TO PREMISES HANDSETINCOMING PHONE LINE aav uvcm-004-V1 Figure 16. When using these outputs, note: pin 1 output number 17 (trigger 1): 15 ohms to ground when closed (output low), open when off (output high, normal default); can be used to reset smoke detector power (must set “output normal low yes” in *79 Menu mode, and set for zone type 54, firezone reset, in *80 Menu mode); or can support 12V relay module† that draws less than 100mA pin 5 output number 18 (trigger 2): 100 ohms to ground when closed (output low); open when off (output high, normal default); or can support 12V relay module that draws less than 20mA † e.g., Altronix AX-RBS 8-PIN TRIGGER CONNECTOR 1 KEY 3 4 56 7 8 (RED) (ORANGE) (YELLOW) (GREEN) (BLUE) (PURPLE) (BLACK) OUTPUT 17 12 AUX. Observe proper polarity when connecting the detectors. Type 22 Disarms the system when the zone is activated. Use *80 Menu mode to define the output functions (see Output Device Programming section). 2.Enable normally open/EOLR zones usingZone Programming mode, “Hardwire Type” prompt. 7845i-ent, 7845GSMADT) and Compass downloading software. Either partition may arm its system if the common zone is faulted, but once armed, the other partition will not be able to arm unless the common zone is first bypassed or the fault is corrected. 80 MENU MODE OR COMBUSTION USEN.O. DETECTOR 2000 CONTACT, OHMS WHICH CLOSES EOLR WHEN POWER TO ZONE TERM. 1-1 Capabilities . 3.Insert the receiver's antennas through the top of the cabinet, into the blocks' right-hand terminals, and tighten thescrews. Make sure to power at least one touchpad in each partition from the control’s auxiliary power output. If only using the on-board triggers, you can use a 4-wire cable (N4632-4, supplied with the control) as shown below. 13-1 Uploading/Downloading via theInternet. Scheduling Mode Create up to 32 schedules to automate various system functions. DATA DATA – IN OUT 4 5 6 7 RED WIRE BLK WIRE GRN WIRE YEL WIRE TO TOUCHPAD TO TOUCHPAD TO TOUCHPAD TO TOUCHPAD IMPORTANT: MAKETHESE CONNECTIONS DIRECTLY TO SCREW TERMINALS AS SHOWN. 58 Zone Programming Assign zone attributes similar to 56 mode, but provides a faster (Expert Mode) programming procedure and is intended for those more experienced in programming controls of this type. If communication/tamper failure occurs on a device with zoneswired to it, all zones on the device will be displayed in their respective partitions. Connections use one of the on-board triggers. 3-1 † These fields must be enabled for Residential Fire, UL Residential Burglar Alarm, and UL Commercial Burglar Alarm installations. Type 02 Assign to zones that are used for entry and exit and require more time thanthe Entry/Exit Burglary #2 primary entry/exit point. 5-1 Completing Zone Programming . LOCATION SWITCH INTERFERENCE WIRING OPENING INDICATOR LED KNOCKOUT AREA CIRCUIT BOARD FOR SURFACE WIRING SOCKET PLUG TORELEASE CIRCUIT BOARD, REMOVE SCREWS AND BEND BACK TABS 5881-003-V0 Figure 9. 3.If desired, use data field *198 to turn on the display of the partition number. 7-1 Zone List Programming . a UL commercial burglar alarminstallation, the keyswitch’s tamper switch must be connected in to the alarm system. Be sure to connect the negative (–) terminal on the power supply unit to terminal 4 (AUX –) on the control. NOTE: Each touchpad must be assigned a unique address, starting at address 16. Zone Expander Modules must be set for specific addresses (07-11), basedon the zone numbers used (see table of addresses in 4219/4229 Expansion Zones section). Only one phone module can be used and it can only be connected to partition 1. Using a Supplementary Power Supply Notes Typical English Display: 6150ADT Typical Custom English Display: 6160ADT Typical Voice Touchpad: 6160VADT AUI: iCenter(see note below) or 6270ADT Touch Screen The system supports up to 8 addressable touchpads, which can be assigned to partitions in any combination (see program fields *190-*196). This restriction is due to the capacitive effect on the data lines when quad cable is used. Disarm (BR only) User number for button must be assigned. CHECK SNAPPOSITION TAB LOCKED PUSH SNAP UNLOCKED TAB CABINET DOOR STEP 1 BOTTOM PUSH ON LOCK UNTIL IT IS SEATED SECURELY lock snap-001-V0 STEP 2 cab Figure 1. Plug the connector at the other end of the harness into the receiver. Refer to those sections for detailed procedures. 4286 Phone Module Wiring Connections Mountingand Wiring the Control Audio Alarm Verification Connections (AAV, “Listen-In”) Using the UVS System with UVCM Module Refer to the connection diagrams below. NOTE: To reduce the risk of fire, use only 26AWG or larger telecommunications line cord for phone line connection. Touchpads powered from supplies that do not have a backup batterywill not function if AC power is lost. ( ) IS APPLIED. 4-3 System Status Report Codes ( 59– 68) . Connect all other ECP devices (touchpads, expander modules, etc.) to the ECP terminals on the AVS board. Connection to the incoming telco line via a RJ31X jackand direct-connect cord, as shown, is essential, even if the system is not connected to a central station. 1-1 Compatible Devices. Notes This product has been designed and laboratory-tested to ensure its resistance to damage from generallyexpected levels of lightning and electrical discharge, and does not normally require an earth ground. b.Slide the mounting plate to the right so that the plate’s left-hand tang slides under the cabinet’s tiewrap loop. 11-1 AVS System Enable and Quick Program Commands. System must be armed forthe Latchkey report to be sent. The 5802MN and 5804 Button Transmitters have replaceable batteries. The Ademco 4146 keyswitch is UL Listed. You must install a battery, since the battery supplies this current. 5) WITH FLYING BLACK: TO AUX. 4204 DIP Switch Address Settings SW ADDRESS 12 13 14 15 2 ON off ON off 3 ON ON off off 4 off offoff off 5 off off off off SW ADDRESS 7 8 9 10 11 2 off ON off ON off 3 off ON ON off off 4 off ON ON ON ON 5 ON off off off off 4204 RELAY DIP SWITCH 4 TYPICAL FOR SETTING DEVICE ADDRESS (SHOWN "OFF") AND ENABLING/DISABLING TAMPER RELAY COVER TAMPER (REED) SWITCH 3 4-PIN TOUCHPAD PLUG RELAY EITHER ORBOTH 2 CAN BE USED RELAY TB1 1 13 14 15 16 YEL DATA IN FROM CONTROL BLK (–) GROUND 12 C 11 NC 10 NO 9 C 8 NC 7 NO 6 C 5 NC 4 NO 3 C 2 NC 1 NO TB2 GRN DATA OUT TO CONTROL RED ( ) 12V Figure 11. Active when the panel is armed in the Away mode. .) for fire. Notes The system supports up to 40 expansion zones (NO orNC) using up to five (5) 4219 and/or 4229 Zone Expander Modules. Provides an instant alarm if faulted when armed in the Away, Stay, Night-Stay, or Instant (night) modes. 5-5 58 Expert Programming Mode Procedures. 2.Connect an EOL resistor across the loopwires at the last detector. 82 Alpha Programming Create alpha descriptors for easy zone identification. 10-1 29 IP/GSM Menu Mode . 1-2 S E C T I O N 2 Mounting and Wiring the Control This sectiondescribes the procedures for mounting and wiring this control and its peripheral devices. 3.Connect the other end of the 3-conductor cable to the 1361X10 Transformer, as shown. 16-2 Regulatory Agency Statements . 2-6 Hardwire Zones. AC Power Outlet Ground: Available from 3-prong, 120VAC power outlets only. 8132ADT iCenter 150mA/350mA†† (200mA/400mA†† alarm) ‡ Figures are for relays 5881/5882 RF Receiver 60mA OFF/relays ON. TERMINALS ONEXTERNAL ALARM CONTROL BOARD SOUNDER 4 ALARM 2000 OBSERVE OHM OUTPUT POLARITY EOL TERMINALS RESISTOR 3 2 CUT RED JUMPER ON CONTROL BOARD TO ENABLE BELL (SOUNDER) SUPERVISION. 2-8 Mounting and Wiring the Control 5 RELAY AUX PWR PROGRAM BLK RED RELAY OUTPUT AS ZONE EOLTERMINALS TYPE 54 POWER (FIRE ZONE N.O. SUPERVISION RESET) RELAY MODULE 4 N.C. A77-716B. Auxiliary Power Output: 12VDC, 600 mA maximum (uses circuit protection). Optional bell supervision detects external sounder wiring short (when in alarm) or open (when bell is off); causes a trouble condition, touchpad display, and sends areport to the central monitoring station, if enabled. Installing the Transmitters 1.To be sure reception of the transmitter's signal at the proposed mounting location is adequate, perform a Go/No Go Test, described in the Testing the System section. 15-3 Specifications & Accessories. power load for all devices exceeds 600mA. 4285/4286 7 VIP MODULE 5 6 LOUDER 1 2 3 4 VOLUME (4286 KEYED ONLY) HEADER UNUSED YELLOW: TO DATA OUT (term. 14-5 Testing theSystem. 5-1 About Zone Programming. This allows site maintenance independent of central station monitoring, and modification to sites globally via theInternet. 4-Wire Smoke Detector Using Relay for Power Reset AUX PWR ( ) 5 TO OUTPUT 17 ( ) BLK RED PROGRAM OUTPUT 17 EOL FOR "OUT NORM POWER LOW" YES IN 79 MENU N.O. SUPERVISION MODE AND AS ZONE RELAY MODULE VIOLET TYPE 54 IN 4-WIRE SMOKE A77-716B. 8-1 Alpha Descriptor Programming. UL For UL commercial burglar alarm installations, use EOLR zones. 2-12 Installing the Transmitters. Install a smoke detector inside every bedroom where someone sleepswith the door partly or completely closed. This allows either partition to arm, while leaving the common partition disarmed for access into the other partition. Type 07 Assign to a zone that has an emergency button. The system touchpad will display a “check” message indicating the appropriate zone (but touchpad beeping does not occur). Makesounder connections to alarm output terminals 3 ( ) and 4 (–). 2 17 no. Alarm by Night Can also be used on a sensor or contact in an area where immediate notification of an entry is desired. This system supports programmable function keys. (Both batteries fit inside the cabinet.) Earth Ground Metal Cold Water Pipe: Use a non-corrosive metalstrap (copper is recommended) firmly secured to the pipe to which the ground lead is electrically connected and secured. UL Use only UL Listed sounding devices for UL installations. 4.If using relays with the 4229, connect the desired field wiring to the unit's relay contact terminals. 3 (zn 25-32) 09 no. If using 1361X10 transformer and powerlinecarrier devices, use the SA4120XM-1 cable (part of 4120TR Trigger Cable). If using a phone module, continue with the following steps. 1-1 3000EN Series: Installation and Setup Guide Compatible Devices Supports up to 8 Addressable Touchpads: English Display Touchpad (6150ADT), Custom English Display Touchpad (6160ADT), and CustomEnglish Display Voice Touchpad (6160VADT) Supports up to four iCenter (AUI) or 6270ADT touch screen devices in addition to up to 8 touchpads (described above). UL NOTE: Uploading/Downloading via the Internet has not been evaluated by UL Functions Single-button arming feature: Can use up to 2 dedicated touchpad keys on Custom EnglishDisplay touchpads to arm the system AWAY, STAY, or NIGHT-STAY Scheduling, which can control devices and/or auto-arm/disarm the system Up to 4 touchpad macros, which can be activated by wired touchpads Paging feature allows certain system conditions to be reported to up to 4 pager phone numbers; can use a dedicated key on touchpadsto send a signal to a pager Built-in Telephone Line Monitoring option can monitor the telephone line voltage and can cause a local display, or a display and trouble/alarm sound. The voltage level between terminals 1 and 2 of the control must not fall below 16.5VAC or else an “AC LOSS” message will be displayed. 6) 23 24 25 TO EARTH GROUND(COLD WATER PIPE, ETC.) (TIP)GREEN (RING)RED RJ31XRING INCOMING TELCO LINE DIRECT TIP CONNECT CORD TIP JACK RING CA38A PREMISES ANSWERING PLUG IN MACHINE AND PHONES CANADA (R)GREY BROWN(T) ANSWERING MACHINE * * TO CONTROL PANEL TERMINALS USED FOR KEYPAD CONNECTIONS * NOTE: IFTHE TELEPHONE HAS BUILT-IN CALLER ID, THE CALLER ID FUNCTION MAY NOT WORK . OR COMBUSTION DETECTOR 2000 OHMS EOLR TO ZONE TERM. 4.You can wire an optional closed-circuit tamper switch (model 112) in series with the zone. 9-1 Adding Custom Words (will not be annunciated by 4286 PhoneModule). Either partition can clear and restore the common zone after an alarm. a fire alarm installation, the keyswitch must be located next to an alphanumeric display touchpad. Recommendations For Smoke And Heat Detectors With regard to the number and placement of smoke/heatdetectors, we subscribe to the recommendations contained in the National Fire Protection Association's (NFPA) Standard #72 noted below. Install a smoke detector inside bedrooms where electrical appliances (such as portable heaters, air KITCHEN BEDROOM BEDROOM TV ROOM KITCHEN DINING BDRM conditioners or humidifiers) are used. Supports up to five (5) 4219, 4229 addressable zone expander modules for up to 40 expansion zones Up to 16 output relays and/or Powerline Carrier Devices (X-10 type) plus two on-board triggers --Use any combination of 4204, 4229 and or Powerline Carrier Devices. A - SIA Model SASW3000EN RECOMMENDATIONS FOR PROPER PROTECTIONThe Following Recommendations for the Location of Fire and Burglary Detection Devices Help Provide Proper Coverage for the Protected Premises. A subsequent short circuit within 90 seconds triggers fire alarm. You can then make devices that are plugged into Powerline Carrier devices perform various functions in response to commands you enterat the security system touchpads. For additional information regarding the 5800TM, refer to the 5800TM’s instructions. The system can control two independent areas of protection (known as partitions) for use by independent users, if desired, by simply assigning zones to one or the other partition during zone programming. 4-13 iCenter (AUI)Enable. If an earth ground is desired for additional protection in areas of severe electrical activity, terminal 25 on the control board, or the cabinet, may be used as the ground connection point. The length of all wire runs for both partitionscombined must not exceed 1500 feet (457m) when unshielded quad conductor cable is used (750 feet if shielded cable is used). 4 15 no. To test the integrity of the ground terminal, use a 3-wire circuit tester with neon lamp indicators, such as the UL Listed Ideal Model 61-035, or equivalent, available at most electrical supply stores. If a keyswitch isused on: an installation that transmits opening and closing signals, the keyswitch zone must be programmed to send opening and closing signals. If the receiver is mounted remotely: Place the RF receiver in a high, centrally located area for best reception. BR KTCHN THIS CONTROL COMPLIES WITH NFPA GARAGE REQUIREMENTS FORTEMPORAL PULSE LVNG RM . 2-1 Mounting Board with RF Receiver. This will decrease range and/or block transmissions. 6-3 Zone Lists. b.Swing the baseof the board into the mounting clips and secure it to the cabinet with the accompanying screws. 5881/5882 RF Receiver (cover removed) 2-11 3000EN Series: Installation Instructions Installing a 5800TM Module 1.Mount the 5800TM next to the RF receiver (between one and two feet from the receiver’s antennas) using its accompanying mountingbracket. 57 Function Key Program each of the four alphabet function keys to perform one of Programming several system operations. Zone Type Description Type 00 Program a zone with this zone type if the zone is not used. 8-PIN TRIGGER CONNECTOR 1 KEY 3 4 5 6 7 8 (YEL) (RED) (GRN) OUT 17 12 AUX. If the tamper is opened when thesystem is armed, an alarm will occur. Faults on the common zone are displayed on common zone touchpads, and will also appear on another partition’s touchpad when that partition is armed. 4-2 Dialer Programming ( 40 – 50) . The examples of goodearth grounds listed at the left are available at most installations

This feature eliminates false alarms due to electrical or physical transients. Touchpads must be set for addresses 16-23 (first touchpad is address 16, which is different from previous controls) and programmed in data fields *190-*196. 2.Use data field program mode to enable touchpad