Defender Kitchen Hood Fire Extinguishing System

Transcription

Defender Kitchen Hood Fire Extinguishing System

Kitchen Duct, Hood and ApplianceFire Extinguishing Systems The duct, hood and appliance have highfire risk with heat, oil and air in kitchen The cook or appliance faults cause high firerisk The dirty hood and duct causes high firerisk The duct, Hood and Appliance fires spreadrapidly in the building through ducts The duct, hood and appliance fires aredifficult to extinguish with 360C heat from oil

Kitchen Duct, Hood and ApplianceFire Extinguishing Systems Most of local regulations stipulate kitchenduct hood and appliance extinguishingsystems before opening building Most of consultants and advisors stipulatekitchen duct hood and appliance extinguishingsystems during Project base There is huge demand for preferred andcompetitive kitchen duct hood and appliancefire extinguishing system World wide Defender is preferred and competitive forinstaller and end users as kitchen duct hoodand appliance fire extinguishing system

Defender is Preferred Defender is manufactured and supported byFinder company. 24 years experience 7/24 sales and technical support Fast Delivery Technical Training Trained and Authorized Installers Exclusive Dealers Regular Installation Inspection Regular Customer Satisfaction Control Marketing Support Brand Awareness Direct Mailing E marketing Exhibition participation Marketing Documents

Defender is preferred Defender is easy to install, use andmaintain. Defender M mechanical system is suitablefor difficult applications Defender P pressurized system is suitablefor fast detection and less cost applications Defender meets customer different sizedapplications requirements4 nozzle systems8 nozzle systems12 nozzle systems16 nozzle systems18 nozzle systems

Defender is Preferable Defender performance is tested and approved by LPCB

Defender is Competitive Defender nozzles coverage are wider thenthe others. The less pipe Works, labor cost andcylinder capacity are needed Defender cylinders are pressurized. Themaintenance and charging are cost effective Defender control head operates both manualand automatic. Additional manual release is notnecessary. Defender P series with pressurized pipingsystem is designed to meet customer costexpectations

Defender M and P Type System Design and Quotation System LayoutSystem ComponentsSystem Detection Line Design and QuantitiesSystem Nozzle Design and QuantitiesSystem Cylinder Capacities

Defender M Type System Design and Quotation System Cylinder Capacities1455 DM08 8 Flow point 9,5L cylinder and activation mechanism1555 DM12 12 Flow point 15L cylinder and activation mechanism1655 DM18 18 Flow point 22,7L cylinder and activation mechanismP2000 Manual activation unit System Detection Line Design and QuantitiesP2750 141C Thermobulb thermal linkP2850 181C Thermobulb thermal linkP2950 260C Thermobulb thermal linkP9000 corner pulley Nozzle Design and QuantitiesP1700 A nozzleP1800 F nozzleP1900 R nozzle

Defender P Type System Layout

Defender P Type System Installation Manualwww.defender.com.tr

Defender M Type System Installation Manualwww.defender.com.tr

Authorized Installerwww.fire-defender.com

Kitchen Duct, Hood and Appliance Fire Extinguishing Systems The duct, hood and appliance have high fire risk with heat, oil and air in kitchen . Defender M Type System Design and Quotation System Cylinder Capacities 1455 DM08 8 Flow point 9,5L cylinder and activation mechanism