MODBUS Damper Interface catalogue Release 1.7 AUGUST 2017Modbus Damper Interface CatalogueTwo Position Smoke Fire Damper InterfaceThis product forms part of a life safety system. Failure to correctlystore, handle, install and maintain the product will directly put atrisk the lives of the occupants and the fabric of the building.- PAGE 1 -Always READ this document BEFOREINSTALLATION. Please Retain forfuture reference.

MODBUS Damper Interface catalogue Release 1.7 AUGUST 2017SFDI-M / FDI-M / SDI-M230V / 120V / 24Vtwo positionDamper Interfacethe Actionair Damper Interface provides a completeModbus communication device to control dampers.ELECTROSTATIC SENSITIVE DEVICET wo Position Smoke Fire Damper Interface Options:SfDI - Mthe Actionair Smoke Fire Damper Interface provides a complete Modbus communication device tocontrol any failsafe spring-return smoke fire damper actuator that incorporates two auxiliary switches.fDI - Mthe Actionair Fire Damper Interface provides a complete Modbus communication device to failsafe, via anelectromagnet, any spring-return fire damper. Monitoring of the open and/or closed position is optional.SDI - Mthe Actionair Smoke Damper Interface provides a complete Modbus communication device to controlany open/closed smoke damper actuator that incorporates two auxiliary switches.Please note: Each interface is available in 24V, 120V, or 230V. Please specify a voltage at time of order.- PAGE 2 -

MODBUS Damper Interface catalogue Release 1.7 AUGUST 2017Mounting Diagram200Preparation75 Only trained and qualified personnel should be allowed toinstall, replace or service this equipment. Installation shouldbe in accordance with the relevant local safety standards. The connectors can accommodate cable diameters up to2.5mm2. It is recommended that all wires be crimped to easeinstallation and replacement of the product. The mains wiring should comply with IEC 60227 or IEC 60245. A switch or circuit breaker should be included as part of theinstallation. The switch or circuit breaker should meet the relevantrequirements of IEC 60947-1 and IEC 60947-3. The switch or circuit breaker should be in close proximity tothe equipment and be within easy reach of the operator. The switch or circuit breaker should be marked as thedisconnecting device for the equipment and shoulddisconnect both poles of the supplyaprox 256016015aprox 25Four mounting holesØ 6mm for mountingwith suitable screwsdepending on whethermounting to a duct,block wall or stud wall.120220Dimensions in mm.Installation1.10Dimensions and MountingThe compact and robust design of the interfaceenclosure allows the unit to be mounted to a duct,block wall or stud wall.Ensure the Interface is located close enough tothe actuator/damper it is controlling/monitoring.Normally, actuator/electromagnet leads are 1m inlength. Also, ensure the Interface is accessible forfuture maintenance purposes.2. Wire the interface in accordance with the wiring diagramsshown following. If the actuator is to be located more than 5mfrom the Interface then contact Safegard Systems for technicalassistance.3. Please be aware that the switch and auxiliary inputs arenot optically isolated. It is recommended that the optionaldetectors (smoke or heat) use failsafe open contacts toguarantee their detection in the event of a fault condition.It is also recommended that the network cables are not runalongside any high voltage or high frequency sources. Also,network cables must not be mixed on an individual networkas they have very different electrical characteristics and couldrender the system unreliable.Please note: 150mm clearance required for lid removal andat cable entry points. Unused cable entries should be sealed withblind washers. Do not drill the enclosure as this will affect itsIP rating.Disconnect the local supply before commencing any workon the Interface.4.If FDI-M, the electromagnet failsafe realease is optional. Ifused, the electromagnet must be protected by a suitablesnubber device.5.If FDI-M, the monitoring of the damper positions is optional.6.Once wiring is complete, apply power to the DI-M. The greenpower LED should illuminate to indicate the presence ofpower.7. The Interface is now ready to be configured using a standardModbus tool or the Safegard system.- PAGE 3 -

MODBUS Damper Interface catalogue Release 1.7 AUGUST 2017SFDI-M Wiring: 230V & 120VSFDI-M Wiring: 24VThermalTripSAFEGARDSGS230-TTo Heat DetectorActuator Example230VActuator DriveS62ActuatorPositionSenseS4SDS624VActuator DriveS2 S11OPTIONALTo Heat DetectorActuator ExampleHDTo uatorPositionSenseS4ACTUATOR DRIVEL NSWITCH INPUTSAUX1AUX2S6 S4S2S1-Aux InputsACTUATOR DRIVE -Green LEDYellow LEDSWITCH INPUTSAUX1AUX2S6 S4S2S1--L N GNDGNDNETWORKNETWORKService Pin-GNDGNDNETWORKNETWORKPOWER INNetworkNetworkService LEDBlue LEDService PinPOWER INPower LEDRed LEDYellow LEDService LEDBlue LED1AT-Green LEDPower LEDRed LED- LSDS2 S112Aux InputsF1HDTo SmokeDetector OR-NetworkNetwork-24V ACN24V DCFDI-M Wiring: 230V & 120VOPTIONALFireDamperElectromagnetfailsafe releaseFDI-M Wiring: 24VTo Heat DetectorHDCLOSEDOPENTo Electromagnetfailsafe releaseTo Heat DetectorTo SmokeDetectorSDDamperPositionSenseACTUATOR DRIVE SWITCH INPUTSL NOPENCLOSEDAUX1AUX2 -ACTUATOR DRIVE -Yellow LEDOPENCLOSEDAUX1AUX2 --Power LEDYellow LEDService LEDService LEDBlue LEDBlue LEDService PinService PinGNDGNDNETWORKNETWORKPOWER INNetwork1ATSWITCH INPUTSRed LEDPower LEDRed LED -GNDGNDNETWORKNETWORKPOWER INNetwork- L-Green LEDGreen LEDL NSDAux InputsAux InputsF1HDCLOSEDOPEN-N24V DC- PAGE 4 - OR-24V ACNetworkNetwork

MODBUS Damper Interface catalogue Release 1.7 AUGUST 2017SDI-M Wiring: 230V & 120VBELIMOBE230SDI-M Wiring: 24VBELIMOBE24OPTIONALTo Heat DetectorActuator ExampleS6ActuatorPositionSenseS4Actuator ExampleHDTo SmokeDetectorOPTIONALTo Heat DetectorSDS6S2 S1313L1 N L2SWITCH INPUTSAUX1AUX2S6 S4S2S1- 1- 2SWITCH INPUTSAUX1AUX2S6 S4S2S1--Green LEDYellow LEDGNDGNDNETWORKNETWORKNetworkService LEDBlue LEDService PinPOWER INPower LEDRed LEDYellow LEDService LEDBlue LED1ATAux InputsPower LEDRed LED Service Pin-GNDGNDNETWORKNETWORKPOWER INNetwork- LSD2ACTUATOR DRIVE-Green LEDL N124VActuator DriveAux InputsACTUATOR DRIVES4HDTo SmokeDetectorS2 S12230VActuator DriveF1ActuatorPositionSense- OR-NetworkNetwork24V ACN24V DCMaintenanceLED Behaviour24V AC/DC version5 x 20mm, Time-Lag Fuse, 2A rated (see F1 on wiringdiagrams); for example Littlefuse 215 seriesFunction Green Red Yellow120/230VAC versions5 x 20mm, Time-Lag Fuse, 1A rated (see F1 on wiringdiagrams); for example Littlefuse 215 seriesOpenOnOffClosedOffOnBlueTravelling Flashing FlashingFault FlashingPing One-shotOfflineOnOnOnWink function: Service LED flashes for 5s- PAGE 5 -On

MODBUS Damper Interface catalogue Release 1.7 AUGUST 2017Two Position Smoke Fire Damper Interface SpecificationsModbusEnvironmentalChip Arm Cortex-M3Operating temperature-5 C to 70 CService functionsStorage temperature-20 C to 70 CHumidity25 % RH to 90 % RH at 70 CMaximum altitude2000 mService pin and service LEDSupply(please specify at time of order)Input voltages(230 23) V AC, 50 Hz(120 12) V AC, 60 Hz(24 4.8) V AC, 50 Hz(24 2.4) V DCConformanceAgency Listings CEMaximum power consumption 2.5 WEMC EN60730-1:00 A1:04 A2:08 A16:07 CISPR 22 /FCC part 15, cl. BOutputLVDEN60730-1:2005 A2:2008Contact typeDPCO mechanicalrelay contactsEnclosureMaximum switched load25 VAMaterial ABS base with polycarbonate lidInputsIP ratingIP 54FlammabilityUL 94V-0Contact type Non-isolated dry contactsPollution Category 2Sense currentDimensions (excl glands)200 mm x 120 mm x 75 mm(L x W x D)Dimensions (incl glands)200 mm x 170 mm x 75 mm(L x W x D)10 mANote:Optional HDIE available: 300 C for 2 hour or 600 C for ½ hour applications.Please refer to Hot Enclosures Catalogue or contact Safegard Systems for details.Complies with European standardsWARNING: The responsible body shall be made aware that, if the equipment is used in a manner not specified by themanufacturer, the protection provided by the equipment may be impaired.The information herein is subject to change without notice. We do not assume any liability arising out of the use of this product. Purchase ofgoods and services is subject to Safegard Systems standard terms and conditions.Product warranty 12 months from date of delivery.Actionair and Safegard are brand names of Swegon Air Management and SafegardSystems respectively and both companies are part of the Swegon Group.Swegon Air Management, South Street, Whitstable, Kent, CT5 3DU, UKT: 01227 276100 F: 01227 264262 E: sales@actionair.co.uk www.actionair.co.ukUnit 33, Southern Cross Business Park, Bray, Co. Wicklow, A98 HT99, IrelandT: 353 1 2761600 F: 353 1 2761611 E: info@safegard.ie www.safegard.ie- PAGE 6 -

MODBUS DaMper Interface catalOgUe releaSe 1.7 aUgUSt 2017 - PAGE 1 - Modbus Damper Interface catalogue two position Smoke fire Damper Interface this product forms part of a life safety system. ailure to correctly f store, handle, install and maintain the product will directly put at risk the lives of the occupants and the fabric of the building.