Architectural Specification Manual: Canada - Technical Glass Products

Transcription

Architectural Specification Manual: Canada800.426.0279tgpamerica.com

PILKINGTON PROFILIT GLAZING SYSTEMPilkington Profilit architectural glazing systems have been designed for worldwide architectural markets. They incorporatethe latest window and material technology. The framing and component details shown in this manual can only beobtained from Technical Glass Products.The Pilkington Profilit glazing system is based on a range of unique cast glass channels, which have high structuralstrength and are contained within a custom designed aluminum perimeter frame. A unique feature of the PilkingtonProfilit system is the wide range of glazing designs that can be achieved without the need to incorporate vertical orhorizontal aluminum members.For specifications, photographs, videos and additional information contact:TECHNICAL GLASS PRODUCTS8699 Escarpment Way, Unit #5Milton, ON L9T 0J5800.426.0279 b:tgpamerica.com1Office:CSI-SPECIFICATIONFull copies of our CSI 08 45 11 specification can be downloaded from our Web site or obtained from our office.This Architectural Specification Manual provides a summary of the specification, design and applications that can be achievedwith Pilkington Profilit. Many special finishes and components are available, please consult Technical Glass Products. 2013 Technical Glass Products. Pilkington Profilit is a registered trademark of Pilkington plc. Lumira aerogel is a registered trademark of CabotCorporation. Technical Glass Products, One Source. Many Solutions., and TGP America are registered trademarks of Technical Glass Products.800.426.0279tgpamerica.com

pageTable of ContentsSECTION 2dateDESIGN - Design OptionsSingle Glazed Tempered Maximum Glass Profile Lengths . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Double Glazed Tempered Maximum Glass Profile Lengths . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Bending Limits of the Aluminum Profiles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1310 13sectionSystemsAluminum Framing Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8Finishes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8Systems Isometric View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Sealant Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10contentsTesting / CertificationsSafety Glazing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7Product Certification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71INTRODUCTION - Product Description and Engineering DataTranslucent Linear Channel Glazing System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1Profile Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1Glass Color Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2Sandblasting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2Typical Vertical Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Glass Installed Vertically Shown in Sectional Views . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Dual Glazed K-60 Performance Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5Lumira aerogel Insulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6Performance Analysis: Preliminary Test Results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6Key Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6Components of the Lumira aerogel System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6Table of ContentsSECTION 1800.426.0279tgpamerica.com

pageTable of Contents (cont.)SECTION 3contents1sectiondateCONSTRUCTION - Applications and DetailsK-41 Interior Head Detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20K-41 Interior Sill Detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21K-41 Interior Jamb Detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22K-60 Exterior Head Detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23K-60 Exterior Sill Detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24K-60 Exterior Jamb Detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25K-60 Interior Sill Detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26K-60 Exterior Thermal Stacking Detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27K-60 Exterior Thermal Head Detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28K-60 Exterior Thermal Sill Detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29K-60 Exterior Thermal Jamb Detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30K-60 Horizontal Head Detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31K-60 Horizontal Sill Detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32K-60 Horizontal Jamb Detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33Glass Corner Detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34Window into Pilkington Profilit Wall . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35Window into Pilkington Profilit Wall Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36K-60 Exterior Thermal Head Receptor Detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37K-60 Exterior Non-Thermal Wind Anchors for High Walls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38K-60 Exterior Non-Thermal Single Glaze Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39-4010 13SECTION 4Table of Contents (CONT.)THE PRODUCT - Profiles and ComponentsK-41 Series Glass . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14K-41 Series WA Framing Profiles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15K-41 Series WT Thermal Framing Profiles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16K-60 Series Glass . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17K-60 Series WA Framing Profiles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18K-60 Series WT Thermal Framing Profiles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19800.426.0279tgpamerica.com

pagedate10 13section1contentsIntroductionSECTION 1 INTRODUCTION800.426.0279tgpamerica.com

1pageIntroductionTRANSLUCENT LINEAR CHANNEL GLAZING SYSTEMThe Pilkington Profilit translucent linear channel glazing system consists of unique, self supporting cast glass channels andan extruded metal perimeter frame. The end result is an opaque but light-transmitting wall. Pilkington Profilit can be used ininterior or exterior applications. The “U-shaped” channels can be installed either vertically or horizontally.The glass is available in a variety of colors and textures with varying translucency allowing for the passage of natural lightwithout the loss of privacy. Pilkington Profilit is energy efficient, provides excellent sound reduction, and it’s one of the mostcost-efficient glass wall systems available. Single or dual glazing options are available for interior and exterior applications,including cladding and screen walls.FEATUREScontentsIntroductionAvailable in long channel lengths (23 feet/7 meters)Allows natural light while maintaining privacyCan be tempered to meet impact safety requirementsEnergy efficientExcellent light transmissionSound insulation (up to 44 db)Can be utilized in curved wallsInstalls vertically or horizontallyAluminum perimeter frame with full range of finish optionsMinimal maintenanceProven performance -- used in Europe for more than 40 yearsK-41Glass Thickness2.36” (60 mm)7 mm1.61” (41 mm)6 mmsectionK-60Flange10 13Series1PROFILE OPTIONSdate 800.426.0279tgpamerica.com

2pageIntroductionDESIGN OPTIONSPilkington Profilit comes in a broad spectrum of colors, textures and finishes. Please visit tgpamerica.com to view any ofthese design options.date10 13GLASS COLORS Standard Cast: Standard channel glass has an inherent slight green hue Low Iron: Pilkington Profilit OW (Low-Iron) is a low iron composition glass that creates a nearly colorless product withimproved light transmission. Please see Pilkington Profilit OW (Low-Iron) fact sheet for more information.section1COLOR COATINGS/SANDBLASTEDAll coatings can be applied onto all available textures. Amethyst-slight blue transparent coating Opaque Enameled Frit-a variety of opaque colored frits that are heat tempered to the glass Opaque Color Coating-a variety of high performance opaque colors that don't require tempering, most RAL color systemoptions are available Metallic Color Coating-opaque custom-blended, high-performance metallic colors that don't require tempering Sandblasted-improves privacy while allowing light transmission; can be applied to all textures (unless they have asurface-applied specialty coating)contentsFUNCTIONAL COATINGSOptional performance coatings improve U-values or better control solar heat gain. These options can't be sandblasted. Low-E: improved u-values Antisol : improved solar heat gainIntroductionSURFACE TEXTURESAll textures can be sandblasted unless they have a surface applied specialty coating. Standard: lightly dimpled surface Macro: netted screen surface Slim Line: thin, linear grooves Wave: well defined ridge texture Clear: no visible texture800.426.0279tgpamerica.com

3pageTypical Vertical InstallationADTypical Vertical InstallationDCB1contentsB10 13sectionAdateC800.426.0279tgpamerica.com

4date10 13section1contentsTypical Vertical InstallationGLASS INSTALLED VERTICALLY SHOWN IN SECTIONAL VIEWSpageTypical Vertical Installation800.426.0279tgpamerica.com

DUAL GLAZED K-60 PERFORMANCE VALUESU-VALUE GLASS ONLYLIGHT TRANSMISSIONSOLAR HEAT GAINCOEFFICIENTSTC RATINGSHADINGCOEFFICIENTSTANDARD .4952%0.5142.59ANTISOL0.4941%0.3842.52PLUS 1.7 (LOW-E) COATING ON #3 S TYPESee Page 6 for information on Lumira aerogel insulation which maximizes the performance values for the PilkingtonProfilit system. 5date10 13section1contents*K-41 Series is typically used in interior installations, thus performance values are not listed.** Performance details coming soon.3M S20SIAR400 Film is available for Solar Heat Gain control. Contact TGP at 1-800-426-0279 for performance information.Performance ValuespagePerformance Values800.426.0279tgpamerica.com

6pageLumira Aerogel InsulationLUMIRA AEROGELPERFORMANCE ANALYSIS: PRELIMINARY TEST RESULTSLumira Aerogel Panel*16 mm (Clear)Lumira Aerogel Panel*K 25/60 Series ProfilitUninsulatedNanogel Panel* 16mm (Clear)U Value (Glass Only)0.490.210.19Light Transmission70%50%38%Solar Heat Gain Coeff. (SHGC)Coeff. (SHGC) (NFRC 200)0.630.420.31424444G 70F 60G 79F 60G 79F 60Condensation Resistance Factor(CRF) (AAMA 1503)section1Sound TransmissionCoeff. (STC) - (E 90)Nanogel 25Panel*25mm (Clear)mm (Clear)contentsWhat is Aerogel?Aerogel is a unique form of highly porous, non-hazardous silica, described as a lattice work of glass strands with very small poresand extremely low solids content (5% solid, 95% air). It is known as the lightest weight and best insulating solid in the world.Lumira Aerogel InsulationLumira aerogel, formerly Nanogel aerogel, a surface-treated amorphous silica, is a safe and non-hazardous material. It isencased in 16 mm polycarbonate sheeting, which is centered in the Pilkington Profilit channel glass cavity. Combined withPilkington Profilit channel glass, all the components of the system are safe, recyclable and environmentally friendly. Forprojects requiring extra thermal performance, contact TGP for custom Lumira aerogel information. Reduces overall energy consumption Enhances daylight design Provides cost-effective daylighting solutions Simplifies installation Improves thermal and acoustic insulation Improves ability to meet building codes without tradeoffsdateKEY BENEFITSCENTERING CLIP FORLUMIRA AEROGEL SYSTEM10 13* Additional Lumira aerogel options, including polycarbonate colors and 25 mm panels for increased performance, areavailable. Please contact TGP.2.017" [51.2]800.426.0279tgpamerica.com

7pageTesting / CertificationsSAFETY GLAZINGNational Building Codes reference ANSI Z 97.1-1984 and Consumer Products Safety Commission: Title 16 part 1201, 16 CFR1201 safety standards for architectural glazing materials. Pilkington Profilit is available in tempered or filmed options tomeet these impact safety requirements.TEMPERINGPilkington Profilit T Tempered Glass: Meets ASTM C1048-97B “STANDARD SPECIFICATION FOR HEAT TREATED GLASS” Meets ANSI Z97:1 and CPSC CFR 1201 (Cat. I and II)PRODUCT CERTIFICATIONThe Pilkington Profilit Translucent Linear Glazing System has been installed throughout the world for over 40 years and hasbeen tested in the United States, Great Britain and Germany for: Air, Water and Structural Performance Sound Reduction Thermal Performance Glazing Safety Impact Safety Hurricane Impact Seismic PerformancecontentsSAFETY FILM3M Scotchshield Ultra Safety (SCLARL 400) can be laminated to the inside surface of Pilkington Profilit. Film is factoryapplied except in special circumstances. Meets ANSI Z97:1 and CPSC CFR 1201 (Cat. I and II)Testing/CertificationsHEAT SOAKING Optional heat soaking of tempered Pilkington Profilit can be supplied according to standard Bauregelliste 11.4.2.1TESTING800.426.0279date10 13sectionPilkington Profilit has been tested to meet the following standards: AAMA 501.4 AAMA 101 AAMA 1801-97 AAMA/NWWDA 101/1 S.297 ASTM F 588-97 NFRC 100-97 ANSI Z97.1-1984 CPSC - 16CFR1201, Cat II Category II impact safety (with safety film or tempering) NOA #06-0810.12 Miami Dade large missile impact - TSA 202, 203 and 204Formal test reports are available by contacting Technical Glass Products at 1-800-426-0279.tgpamerica.com

8pageSystemsALUMINUM FRAMING SYSTEMSAluminum perimeter frames are extruded from window grade alloy 6063 complying with the requirementsof ASTM B221. The frames consist of a basic channel system with a plastic insert for the glass. Various framefinishes are offered including anodized, painted and mill finish.The profiles are available in two sizes for both the K-41 and K-60 Series glass types with many variations ofextrusion to suit any installation condition. The profiles are also available with a thermal break, preventingcold bridging through the Pilkington Profilit system. The PVC insert locates the glass within the aluminumframe, preventing glass-to-metal contact and is impact and weather resistant. The simplicity of the aluminumframework, with the small number of components, allows for a quick easy installation.Note: TGP framing systems are designed to meet or exceed the AAMA industry standards and US perimeter detailing.FINISHESMILL FINISHFrame profiles may be supplied for finishing in accordance with individual contract requirements.date10 13section1contentsARCHITECTURAL PAINTED COATINGSA wide range of architectural painting specifications can be pre-applied to the finish, including a wide range ofPPG Architectural paint systems and colors.SystemsANODIZEDFrame profiles can also be supplied with anodized finish in a full range of anodized colors. This is classified as a“superior external architectural” finish and has a surface penetration of .007 or greater inches.800.426.0279tgpamerica.com

9pageSystemsdate10 13section1contentsSystemsSYSTEMS ISOMETRIC VIEW800.426.0279tgpamerica.com

10pageSealant DetailsSEALANTSThe sealant used is a high quality translucent silicone, which picks up the natural tint of the glass. The sealantis applied to all glass-to-glass, glass-to-aluminum and aluminum-to-structure joints, providing a completelyweather-tight seal to the Pilkington Profilit system. The silicone recommended is a one-part moisture curingsealant. The sealant has outstanding durability, resisting chemical and atmospheric deterioration.Recommended Sealants: Schnee Moorhead S731, Dow Corning 1199, GE Sil-Glaze SCS 2801, and Tremco Tremsil 600.12" [3]Sealant DetailsPROFILIT CHANNEL GLASSSILICONE SEALANTcontentsSILICONE SEALANTGASKET #166.25" [6]BACKER RODSILICONE SEALANT10 13BRACKET-ATTACHMENTLEG TURNED UPWARDsection1.12" [3]PROFILIT CHANNEL GLASSdateGASKET #166.25" [6]BRACKET-ATTACHMENTLEG TURNED DOWNWARD800.426.0279tgpamerica.com

pagedate10 13section2contentsDesignSECTION 2 DESIGN800.426.0279tgpamerica.com

11pageDesign OptionsSINGLE GLAZED TEMPEREDMAXIMUM GLASS PROFILE LENGTHS IN METERS(Unsupported Glass Length for Vertical Installations in Canada)Pilkington Profilit Glass TypeSINGLE GLAZING - Wired and Non WiredK 22/41/6K 25/41/6K 32/41/6K 50/41/6K 22/60/7K 25/60/7K ePlease Note: Longer installation lengths may be achieved with the use of wind anchors. Contact TGP forfurther information10 13These tables give maximum installation lengths in meters for vertically glazed tempered Pilkington Profilitglass within closed buildings and should be used as a guide only. All design details should be confirmedby Technical Glass Products’ technical service department. All installation lengths have been calculated toaccommodate a 50% overload safety factor in accordance with National Testing protocol.section20.50Design OptionsDesign Load lbs/ft2contentsDesign Load kN/m2800.426.0279tgpamerica.com

12pageDesign OptionsDOUBLE GLAZED TEMPEREDMAXIMUM GLASS PROFILE LENGTHS IN METERS(Unsupported Glass Length for Vertical Installations in Canada)K 25/41/6K 32/41/6K 50/41/6K 22/60/7K 25/60/7K 53.0062.001.501.401.301.002.402.302.00These tables give maximum installation lengths in meters for vertically glazed tempered Pilkington Profilitglass within closed buildings and should be used as a guide only. All design details should be confirmedby Technical Glass Products’ technical service department. All installation lengths have been calculated toaccommodate a 50% overload safety factor in accordance with National Testing protocol.Design OptionsK 22/41/6contentsPilkington Profilit Glass TypeDOUBLE GLAZING - Wired and Non Wired2Design Load lbs/ft2sectionDesign Load kN/m2datePlease Note: Longer installation lengths may be achieved with the use of wind anchors. Contact TGP forfurther information10 13Maximum span (width) for horizontal Pilkington Profilit is 13’-0” or lesser lengths as indicated by the chart.800.426.0279tgpamerica.com

13pageDesign OptionsBENDING LIMITS OF THE ALUMINUM PROFILESIt is possible to curve the aluminum profiles successfully on plan. Non thermally broken profiles can also becurved on elevation to form arches; glass is cut at an angle to accommodate the arch and fit within the profile.The minimum radius that the aluminum profiles may be bent is 6'6''. This radius is measured to the outside ofthe frame as shown in the drawing below.:section2contentsDesign OptionsK-60 Series 980WA and WT981WA and WTdate10 13MINIMUM RADIUSK22 6'6'' (2m)K25 6'6'' (2m)K32 10'6'' (3.2m)K50 24'7'' (7.5m)800.426.0279tgpamerica.com

pagedate10 13section3contentsPROFILES AND COMPONENTSThe Product - Profiles and ComponentsSECTION 3 THE PRODUCT800.426.0279tgpamerica.com

14pageK-41 Series Glassdate10 13section3contentsK-41 Series GlassCHANNEL GLASS AVAILABLE IN .24 IN (6 mm) THICKNESS800.426.0279tgpamerica.com

15pageK-41 Series WA Framing Profiles1.97" [50]K-41 Series WA Framing Profiles2.44" [62]2.20" [56]contents950WA HEAD / JAMB OR SILL FOR INTERIOR APPLICATIONSsection32.44" [62]2.20" [56]1.73" [44]10 13.98" [25]date961WA SILL800.426.0279tgpamerica.com

16K-41 Series WT Thermal Framing Profiles2.44" [62]pageK-41 Series WT ThermalFraming Profiles2.36" [60]2.21" [56]date10 13section3contents950WT HEAD / JAMB800.426.0279tgpamerica.com

17pageK-60 Series Glassdate10 13section3contentsK-60 Series GlassCHANNEL GLASS AVAILABLE IN .28 IN (7 mm) THICKNESS800.426.0279tgpamerica.com

18pageK-60 Series WA Framing Profiles3.35" [85]3.35" [85]2.95" [75]984WA HEAD / JAMBFOR HORIZONTAL INSTALLATION ONLYsection3contents980WA HEAD / JAMB OR SILL FOR INTERIOR APPLICATIONS10 133.35" [85]3.11" [79]1.73" [44].12" [3]date2.17" [55]3.11" [79]K-60 Series WA Framing Profiles3.11" [79].98" [25]981WA800.426.0279tgpamerica.com

19pagesection3contentsK-60 Series WT Thermal Framing ProfilesK-60 Series WT ThermalFraming Profiles10 133.35" [85]date3.11" [79]1.73" [44].98" [25]981WT SILL800.426.0279tgpamerica.com

pagedate10 13section4contentsAPPLICATIONS AND DETAILSConstruction - Applications and DetailsSECTION 4 CONSTRUCTION800.426.0279tgpamerica.com

WOOD BLOCKINGIF NEEDEDSHIM, BACKER ROD& SILICONE SEALANTFASTENER WITH RUBBER WASHERINSTALLED ON 12" TO 18" CENTERSOR TO STUDS.25" [6]962-2 VINYL INSERTSTRUCTURE ORDROP CEILING20K-41 Interior Head DetailpageK-41 Interior Head Detailcontents1.97" [50]950WA FRAME USED FOR HEAD.79" [20]4GLASS SHIM41-044GLASS SHIMsectionSILICONE SEALANTK-41 SERIES GLASS10 13.24" [6]1.93" [49]date2.44" [62]800.426.0279tgpamerica.com

21dateNOTE: USE WOOD BLOCKING TO MAINTAIN A MINIMUM 1/2" GLASS BITE INTO FRAMING.10 13section4contentsK-41 Interior Sill DetailpageK-41 Interior Sill Detail800.426.0279tgpamerica.com

SILICONE SEALANTSTRUCTURE.79" [20]GASKET #166INSTALLED ON 12" TO 18"CENTERS OR TO STUDS1.93" [49].24" [6]2.44" [62]SHIM, BACKER RODAND SILICONE SEALANTFLANGE PLANK USED AT JAMB2" MIN. TO AS REQUIREDK-41 SERIES GLASS.25" [6]22date10 131.97" [50]NOTE: MINIMUM 3/4" GLASS BITE INTO FRAMINGsection.12" [3]contents962-2 VINYL INSERTFLANGE PLANK USED AT JAMB2" MIN. TO AS REQUIRED41-044 GLASS SHIM4950WA FRAMEUSED FOR JAMBK-41 Interior Jamb DetailpageK-41 Interior Jamb Detail800.426.0279tgpamerica.com

2310 13section4contentsK-60 Exterior Head DetailpageK-60 Exterior Head Detail800.426.0279dateNOTE: MAINTAIN A 3/4” GLASS BITE INTO FRAMINGtgpamerica.com

24pageK-60 Exterior Sill Detail.28" [7]41-044GLASS SHIM981-2 VINYL INSERTSILICONE SEALANT981WA FRAMEUSED FOR SILL.51" [13]1.73" [44]BACKER RODAND SILICONE SEALANT.25" [6]contentsK-60 SERIES GLASS42.83" [72]section3.35" [85]K-60 Exterior Sill DetailK-60 SERIES GLASS INSTALLED INTO 981WAFRAME PROFILE WITH 981-2 VINYL INSERT.FASTENER WITH RUBBER WASHERINSTALLED ON 12" TO 18" CENTERSOR DIRECT TO FLOOR JOISTSNOTE: MAINTAIN A 1/2” GLASS BITE INTO FRAMING800.426.0279tgpamerica.comdateSTRUCTURE10 13SHIM FORUNLEVEL FLOOR

GASKET #166STRUCTURE.79" [20]FASTENER WITH RUBBER WASHERINSTALLED ON 12" TO 18"CENTERS OR TO STUDS.12" [3]2.83" [72].28" [7]3.35" [85]SHIM, BACKER RODAND SILICONE SEALANTFLANGE PLANK USED AT JAMB2" MIN. TO AS REQUIRED2.17" [55].25" [6]2510 13NOTE: MAINTAIN A 3/4” GLASS BITE INTO FRAMINGdateK-60 SERIES GLASScontentsSILICONE SEALANT980-2 VINYL INSERT4FLANGE PLANK USED AT JAMB2" MIN. TO AS REQUIRED41-044 GLASS SHIMsection980WA FRAMEUSED FOR JAMBK-60 Exterior Jamb DetailpageK-60 Exterior Jamb Detail800.426.0279tgpamerica.com

26dateNOTE: USE WOOD BLOCKING TO MAINTAIN 1/2” GLASS BITE INTO FRAMING10 13section4contentsK-60 Interior Sill DetailpageK-60 Interior Sill Detail800.426.0279tgpamerica.com

27pagedate10 13section4contentsK-60 Exterior Thermal Stacking DetailK-60 Exterior ThermalStacking DetailNOTE: SEE PAGE 37 FOR A HEAD RECEPTOR DETAIL TOACCOMODATE INTERSTORY MOVEMENT.800.426.0279tgpamerica.com

28pageK-60 Exterior Thermal Head DetailSTRUCTURESHIM, BACKER RODAND SILICONE SEALANT.25" [6]980-2 VINYL INSERT2.56" [65]contents980WT FRAME USED FOR HEAD.79" [20]K-60 Exterior Thermal Head DetailFASTENER WITH RUBBER WASHERINSTALLED ON 12" TO 18" CENTERSOR TO STUDSSILICONE SEALANT41-044GLASS SHIMsection4K-60 SERIES GLASS.28" [7]2.83" [72]date10 133.35" [85]NOTE: MAINTAIN A 3/4” GLASS BITE INTO FRAMING800.426.0279tgpamerica.com

29date10 13section4contentsK-60 Exterior Thermal Sill DetailpageK-60 Exterior Thermal Sill DetailNOTE: MAINTAIN A 1/2” GLASS BITE INTO FRAMING800.426.0279tgpamerica.com

304contentsK-60 Exterior Thermal Jamb DetailpageK-60 Exterior Thermal Jamb Detaildate10 13sectionNOTE: MAINTAIN A 3/4” GLASS BITE INTO FRAMING800.426.0279tgpamerica.com

31pageK-60 Horizontal Head Detail.25" [6]SHIM2.95" [75]STRUCTURE.79" [20]41-044 PVC GLASS SHIMK-60 Horizontal Head Detail984WA HEAD FRAMESILICONE SEALANTGASKET #166980-2 VINYL INSERTSILICONE SEALANTBACKER RODBRACKET S-29896 LEG TURNED DOWNFOR ATTACHMENT: HALFEN BOLT BC1211contentsK-60 SERIES GLASS2.93" [72]BRACKET S-29896 LEG TURNED UP.28" [7]4.040 THK [1 MM] SEPARATION MATERIAL (CUSHION)section.25" [6]date10 132-3 MM SPACE BETWEENBRACKET AND GLASSPANEL BELOW800.426.

* Additional Lumira aerogel options, including polycarbonate colors and 25 mm panels for increased performance, are available. Please contact TGP. Lumira Aerogel Panel* 16 mm (Clear) Lumira 25 mm (Clear) page contents section date 7 10 13 1 00.426.0279 tgpamerica.com Testing / Certifications