1600-IP Series Product Manual - Viking Electronics

Transcription

Designed, Manufactured and Supported in the USAVIKINGSECURITY & COMMUNICATION1600-IP SeriesPRODUCTMANUALADA Compliant VoIPEmergency PhonesMarch 25, 2021ADA & CE Compliant VoIP Emergency Phoneswith Built-In Dialer and Digital Voice AnnouncerThe 1600-IP Series of ADA Compliant VoIP Emergency Phones are designed toprovide quick and reliable handsfree communication for SIP VoIP phone systemswith PoE. All 1600-IP Series phones meet ADA requirements for elevator oremergency telephones, and can be programmed from any touch tone phone orPC on the same LAN or remotely using a static IP address. The phones can dialup to 5 programmable emergency numbers. In addition, the E-1600-20-IP,E-1600-22-IP, E-1600-52-IP and E-1600-TP2IPEWP feature a second "INFO"button that will dial up to 5 non-emergency numbers. Two amp relay contacts areprovided for strobe light, camera, door/gate control, etc.The 1600-IP Series phones can be programmed to automatically deliver a digitalannouncement to identify the location of the emergency call. Alternatively, a DTMFtouch tone code may also be delivered. A “Call Connected” LED can be initiatedmanually or automatically. All programming parameters, including phone numbersand location numbers, are stored in non-volatile memory, requiring no batteries.All units are PoE powered.For outdoor installations where the unit is exposed to precipitation or condensation,select 1600-IP Series phones are available with Enhanced Weather Protection(EWP). EWP products are designed to meet IP66 standards and may feature foamrubber gaskets, sealed connections, gel-filled butt connectors, as well as pottedcircuit boards with internally sealed, field-adjustable trim pots and DIP switches foreasy onsite programming. For more information on EWP, see DOD 859.!Installation requires a Network Administrator / IT Technician Automatic polling and programming software included2 Amp relay contacts for door/gate or SL-2 strobe light controlSIP compliant (see page 2 for more information)Outbound Proxy, Authentication ID, Peer to Peer, VLAN TaggingPoE powered (class 1, 4 Watts)Automatic Noise Canceling (ANC) feature for proper operation in noisy areasVoIP eliminates the need for “Push to Talk” modeNetwork downloadable firmwareMeets ADA requirements for Emergency Phones:- Automatically lights the Red “Call Connected” LED- Transmits a unique location I.D. code or voice announcement- Grade 2 Braille label for the visually impairedNon-volatile digital voice announcer with 28 seconds of voice memoryHandsfree operationMarine grade 316 stainless steel prevents corrosion on the stainless steel modelsLaser etched graphics on stainless steel modelsDials up to 5 emergency numbersE-1600-20-IP, E-1600-22-IP, E-1600-52-IP, and E-1600-TP2IPEWP dial up to 5 nonemergency “INFO” numbersCycles through backup phone numbers on busy or no-answerOptional Enhanced Weather Protection (EWP), EWP products are designed to meetIP66 Ingress Protection Rating, see DOD 859Hangs up on busy signal, time-out or touch tone commandExtended temperature range (-40 F to 140 F)11 different chassis or board only availableAvailable in 42” tower phone model E-1600-BLTIPEWP (DOD 249)Optional LV-1K Line verification Panel (DOD 246)Optional PB-100 Polling System available (DOD 232)Optional SL-2 or BLK-4-EWP strobe light kit available (DOD 242/654)Optional E-1600A-MK-GNP Pedestal Mounting Kit (DOD 227)Optional PB-1 Panic Button Kit (DOD 233)Diagnostics for testing microphone, speaker, and E-1600-BL-IP E-1600-BLP-IP eatures cations ElevatorsParking ramps/lotsEmergency pool phonesATM machinesMedical centersSilent hold-up alarm dialerwith an optional PB-1 PanicButton Kit (DOD 233) Area of refuge locationsLobbiesEntrywaysCampus emergency stationsStadiumsConvention centersPublic access areas* Americans with Disabilities Act of 1992 contains federalregulations regarding elevator telephones (Public Law wer: PoE class 1 ( 4 Watts)Maximum Sound Pressure: 95 dB SPL @ 1mDimensions: See Installation and SpecificationsOperating Temperature: -40 F to 140 F (-40 C to 60 C)Humidity - Standard Products: 5% to 95% non-condensingHumidity - EWP Products: Up to 100%Audio Codecs: G711u, G711a, G722Network Compliance: IEEE 802.3 af PoE, SIP 2.0 RFC3261, 100BASE-TX withauto cross overRegulatory Compliance: CE, FCC Part 15 and Canada ICES-003 Class AConnections: (1) RJ45 10/100 Base-T, (3) gel-filled butt connectors

VoIP SIP System CompatibilityFor compatibility and vendor specific detailed configuration instructions, see the Viking VoIPSIP System Compatibility List, DOD 944. To open and download this PDF file:Scan the QR code below to openand download the Viking VoIPSIP System Compatibility List1. Go to www.vikingelectronics.comand enter 944 in the search box- OR -2. Click Application Note (DOD 944)to open and download the PDFImportant: Exclusion from this list means only that compatibility has not been verified, it does not meanincompatibility. If you have questions, please call Viking Electronics at 715-386-8861.2

Overview of Chassis and Mounting OptionsNote: When European CE compliance is required, mount open board models within a metal enclosure.Model: E-1600-53-IPModel: E-1600-20-IPDescription: 1600-IP board (PCB) only kit.Can be used to convert any analog Viking1600A-Series phone to a VoIP versionHxWxD: 5.0 x 5.0 x 2.25Mounting: Flush mount with included rough-in box (will notfit in a double gang box), or surface mount with a VE-5x5Description: Two button, 14 gauge marine grade 316 stainless steel with #4 brushed finish, T-10 Torx Security ScrewsModel: E-1600-IPHxWxD: 5.25 x 4.0 x 2.0Mounting: Surface mountDescription: 16 gauge steel with texturedred powder paintModel: E-1600-22-IPHxWxD: 5.0 x 5.0 x 2.25Mounting: Flush mount in a standard double gang electricalbox or surface mount with a VE-5x5Description: Two button, 14 gauge marine grade 316 stainless steel with #4 brushed finish, T-10 Torx Security ScrewsModel: E-1600-45-IPHxWxD: 5.25 x 4.0 x 2.0Mounting: Surface mountDescription: 16 gauge steel with texturedyellow powder paintModel: E-1600-30-IPHxWxD: 5.0 x 5.0 x 2.25Mounting: Flush mount with included rough-in box (will notfit in a double gang box), or surface mount with a VE-5x5Description: 14 gauge marine grade 316 stainless steelwith #4 brushed finish, T-10 Torx Security ScrewsModel: E-1600-60-IPModel: E-1600-32-IPHxWxD: 5.25 x 4.0 x 2.0Mounting: Surface mountDescription: 16 gauge steel with texturedblue powder paint and “POLICE” verbiageHxWxD: 5.0 x 5.0 x 2.25Mounting: Flush mount in a standard double gang electricalbox or surface mount with a VE-5x5Description: 14 gauge marine grade 316 stainless steelwith #4 brushed finish, T-10 Torx Security ScrewsModel: E-1600-65-IPModel: E-1600-50-IPHxWxD: 5.25 x 4.0 x 2.0Mounting: Surface mountDescription: 16 gauge steel with texturedblue powder paintDescription: Single button 1600-IP parts kit without chassisModel: E-1600-52-IPDescription: Two button 1600-IP parts kit without chassisModel: E-1600-55-IPModel: E-1600-03-IPHxWxD: 5.0 x 5.0 x 2.0Description: Universal emergency phonekit to install behind elevator panels or whena custom panel is usedHxWxD: 7.22 x 5.36 x 1.55Mounting: Surface mountDescription: 14 gauge marine grade 316 stainless steelwith #4 brushed finishModel: E-1600-02-IPModel: E-1600-TP-IPEWP Model: E-1600-TP2IPEWPHxWxD: 13.0 x 10.5 x 2.0Mounting: Flush mountDescription: 12 gauge marinegrade 316 stainless steel with #4brushed finishHxWxD: 11.75 x 9.5 x 2.0Mounting: Flush mountDescription: Direct physicalreplacement for Talk-A-Phonemodels ETP-400V or VoIP-500HxWxD: 11.75 x 9.5 x 2.0Mounting: Flush mountDescription: Direct physicalreplacement for Talk-A-Phonemodels ETP-400DV or VoIP-500D3Model: E-1600-GT-IPEWPHxWxD: 12.0 x 10.0 x 2.0Mounting: Flush mountDescription: Direct physicalreplacement for GAI-TRONICS RedAlert Model 397-700

Features OverviewRear (PCB) View of E-1600-IP SeriesEmergency PhoneasdesaxtffMAC:18E80FXXXXXXPoE LAN Port 10/100, PoE Class 1( 4 Watts): Connect to your LAN viaRJ45 plug and CAT5 or greatertwisted pair wire.MAC Address Label: The MACaddress is a unique 12 digit numberused by routers to send network trafficto the correct IP address.Yellow Network Status LED: Lightssteady to indicate power and datalink. Blinks to indicate network activity.Green Unit Status LEDViking model LV-1Kshown (not included),see DOD 246- BlackConnect to OptionalStrobe Light, LV-1K, etc. OR RedOptional 2 Amp RelayOutput ContactsBlack(2A@30VDC / 250VAC max)BlackRedRedN.C. (Gray)YellowCOM. (Blue)Yellow- BlackN.O. (Yellow) RedViking model SL-2shown (not included),see DOD 242LEDHelp SwitchInfo Switch (optional)SpeakerMicrophone3 Gel-Filled ButtConnectors (included)Note: The gel-filled (water-tight) butt connectors are designed for insulation displacement on 19-26 gauge wire with amaximum insulation of 0.082 inches. Cut off stripped wire ends before terminating.4

Installation and SpecificationsThe following sections show specifications and installation instructions for the different chassis in the 1600-IP Series.IMPORTANT: Electronic devices are susceptible to lightning and power station electrical surges from both the ACoutlet and the telephone line. It is recommended that a surge protector be installed to protect against such surges.E-1600-IP / E-1600-45-IP / E-1600-60-IP / E-1600-65-IPOptional Enhanced Weather Protection (EWP) Available: EWPproducts are designed to meet IP66 standards and may featurefoam rubber gaskets, sealed connections, gel-filled butt connectors,as well as potted circuit boards with internally sealed, field-adjustabletrim pots and DIP switches for easy onsite programming. For moreinformation on EWP, see DOD 859.Dimensions: 5.25” x 4.0” x 2.0” (133 mm x 102 mm x 51 mm)Shipping Weight: 2.5 lbs (1.13 kg)Material: 0.062” thick (16 gauge) steelFinish: E-1600-IP: Red powder paintE-1600-45-IP: Yellow powder paintE-1600-60-IP: Blue powder paint with “POLICE” verbiageE-1600-65-IP: Blue powder paintConnections: Gel-filled butt connectorsMounting: Surface mount to walls, posts, single gang boxes or 4”x 4” electrical junction boxes or recess mount in elevator phoneboxes. Attach mounting plate in desired location. Attach wires thenfasten cover to mounting plate with set screw.Note: For greater weather resistance, apply a bead of clear siliconcaulking around the top edge and sides of the chassis.Optional Gooseneck Pedestal Mounting Kit: The E-1600A-MKGNP Mounting Kit (DOD 227) allows you to mount the E-1600A, E1600-40A, E-1600-45A, E-1600-60A or E-1600-65A to any VikingGooseneck Pedestal (DOD 424).4.00EMERGENCYPHONE(Bottom View)POLICEon model E-1600-60-IP only3/4" (0.75”)knockout2.00Earth Ground the Green/Yellowwire using the provided wire nut5.25CALLCONNECTEDPUSH FOR1.15EarthGroundRed Call Connected LEDHELPSetScrewPush to Call ButtonVIKING CondensationDrain HoleGrade 2 Braille Label(Front View)3.402.00Model E-1600-45-IPhas "EMERGENCY"vertically down the side.Model E-1600-60-IPhas "POLICE"vertically down the side.(4) .20 dia.mountingholes0.703diameter3.404.963.301.700.15 x 0.31 WireExit Notch(2) .20 x .40slots for singlegang box1.703.82(Mounting Plate)(Side View)5Model E-1600-IPshown withoptional VE-GNPpedestal andE-1600A-MK-GNPmounting kit.

E-1600-SS-IP / E-1600-RD-IP / E-1600-YL-IP / E-1600-BL-IP / E-1600-BLP-IP / E-1600-BK-IPConnections: Gel-filled butt connectorsMounting: Surface mount to walls, posts or single gang electricalboxes. Attach the mounting plate in desired location and connectthe wires. Then, secure the phone to the mounting plate withprovided 8-32 set screws.Optional Enhanced Weather Protection (EWP) Available: EWPproducts are designed to meet IP66 standards and may feature foamrubber gaskets, sealed connections, gel-filled butt connectors, aswell as potted circuit boards with internally sealed, field-adjustabletrim pots and DIP switches for easy onsite programming. For moreinformation on EWP, see DOD 859.Note: For greater weather resistance, apply a bead of clear siliconcaulking around the top edge and sides of the chassis.Dimensions: 5.75” x 3.08” x 1.05” (146 mm x 78 mm x 27 mm)Shipping Weight: 2.5 lbs (1.3 kg)Material / Finish E-1600-SS-IP only: 0.060” thick (16 gauge)marine grade 316 stainless steel with a #4 brushed finishMaterial: 0.060” thick (16 gauge) 304 stainless steelFinish: E-1600-RD-IP: Red fine texture powder paintE-1600-YL-IP: Yellow fine texture powder paintE-1600-BL-IP: Blue fine texture powder paintE-1600-BLP-IP: Blue fine texture powder paint with“POLICE” verbiageE-1600-BK-IP: Black fine texture powder paint3.08BOTTOM VIEWEMERGENCYPHONEPOLICECondensationDrain Holes0.313Radius(model E-1600-BLP-IP only)SpeakerGrade 2 Braille Label5.75PUSH FORHELPSetScrewVIKING Push to Call button with redbacklit Call Connected LEDMicrophoneSIDE VIEW0.313 RadiusCALL CONNECTED WHEN LIT1.05FRONT VIEW2.922.520.20 x 0.43mounting slotUPMOUNTINGPLATEDIMENSIONSMount withthis arrowpointing up3.905.323.280.78 diameterwire exit hole0.63(4) 0.20 diametermounting holes0.30 diametercountersunkmounting hole6SetScrew

E-1600-02-IPDimensions: 13” x 10.5” x 2” (330mm x 267mm x 51mm)Shipping Weight: 7 lbs (3.18 kg)Connections: Gel-filled butt connectorsMaterial: 0.105” (12 gauge) brushed stainless steelMounting: Flush mount in elevator cabs, ATMs, stairwells,hallways, etc.Suggested Hardware: (6) #8 x 3/4 flat head phillips sheetmetal type A screws (not included)Optional Enhanced Weather Protection (EWP) Available:EWP products are designed to meet IP66 standards and mayfeature foam rubber gaskets, sealed connections, gel-filled buttconnectors, as well as potted circuit boards with internally sealed,field-adjustable trim pots and DIP switches for easy onsiteprogramming. For more information on EWP, see DOD 859.Note: When mounting outside to rough or uneven surfaces(brick, stucco, etc.) apply a bead of clear silicone caulkingaround the top edge and sides of faceplate.Note: When European CE compliance is required, mountonto a metal enclosure.10.50.250.2510.03.83.1Earth Ground theGreen/Yellowwire using theprovided wire CTED12.5PUSH FORGrade 2BrailleLabelRed CallConnectedLED4.7HELPEarthGroundVIKING Push ToCall Button2.0(6) 0.188 diametercountersunk holes(Side View)7

E-1600-03-IPDimensions: 7.22” x 5.36” x 1.55” (183mm x 149mm x 39mm)Material: 14 gauge vandal resistant Marine grade 316 brushedstainless steel panelShipping Weight: 3.0 lbs (1.36 kg)Connections: Gel-filled butt connectorsMounting: Surface mount to walls, posts, single gang boxes, doublegang boxes or 4” x 4” electrical junction boxes or recess mount inelevator phone boxes. Attach mounting plate in desired location.Attach wires then fasten cover to mounting plate with set screw.Optional Enhanced Weather Protection (EWP) Available:EWP products are designed to meet IP66 standards and mayfeature foam rubber gaskets, sealed connections, gel-filled buttconnectors, as well as potted circuit boards with internally sealed,field-adjustable trim pots and DIP switches for easy onsiteprogramming. For more information on EWP, see DOD 859.Note: For greater weather resistance, apply a bead of clear siliconcaulking around the top edge and sides of the chassis.(Front View)5.36EMERGENCYPHONELaser Etched GraphicsGrade 2 Braille LabelEarth Ground the Green/Yellowwire using the provided wire nutEarthGroundPUSH FORHELP7.22VIKING Marine grade 316stainless steel faceplateand push button switch(sealed per IP67)CALLCONNECTEDCall Connected LEDPush to Call buttonVIKING (2) 8-32 x .5" setscrews provided(Mounting Plate)(4) .22 diametermounting holes1.69CondensationDrain Hole0.781dia.1.703.403.306.781.55(Bottom View)0.7950.80(4) .187 x .50 slotsfor double gang box1.702.6053.405.00(2) .187 x .50 slotsfor single gang box8

E-1600-20-IPDimensions: Overall: 5.0” x 5.0” x 2.25” (127mm x 127 x 57mm),Plastic Electrical Box: 4.0” x 4.0” x 2.14” (102mm x 102mm x54mm)Optional Enhanced Weather Protection (EWP) Available: EWPproducts are designed to meet IP66 standards and may featurefoam rubber gaskets, sealed connections, gel-filled buttconnectors, as well as potted circuit boards with internally sealed,field-adjustable trim pots and DIP switches for easy onsiteprogramming. For more information on EWP, see DOD 859.Shipping Weight: 2.12 lbs (1.0 kg)Front Panel Material: 14 gauge Marine grade 316 brushedstainless steelNote: When mounting outside to rough or uneven surfaces (brick,stucco, etc.) apply a bead of clear silicone caulking around the topedge / sides of faceplate or VE-5x5.Connections: Gel-filled butt connectorsMounting with Plastic Rough-In Box (included): Flush into walls,mounts to side of wall stud.Mounting with Optional VE-5x5: Surface mount to walls, single gangboxes, double gang boxes, posts, or to a Viking VE-GNP Gooseneckpedestal, see DOD 424.Note: When European CE compliance is required, mount inoptional VE-5X5 metal enclosure.2.1”* Front View ofPlastic Rough-InBox (included)Peel paper liner and adhere gasketto back of panel, centering overmounting holes. Caution: For roughsurfaces (ie: brick, stucco, etc.)additional caulking may be required.4.0"Wall Stud** Wireknock out(4) T-10 Torx stainless steel,flat head, security screwsand drive bit (included)Laser Etched GraphicsPHELINFO(2) Standardflat head drywall (sheetrock) screws(not included) OR Earth Ground theGreen/Yellowwire using theprovided wire nutLCALCTEDNEMarine grade 316 stainlesssteel faceplate and push buttonswitches (sealed per IP67)C ONGrade 2 Braille Label"Help" Push to Call ButtonEarthGroundCall Connected Red LED"Info" Push to Call ButtonCondensation Drain Hole5.22”3.25”(4) 0.38” diameter(for gooseneckpedestal mounting)(2) 0.2 x 0.43 slots for single gang box(4) 0.2 x 0.43 slots for double gang boxCondensationDrain Hole5.14”3.0” 3.3”**(2) 0.74"diameter3.0”2.25”Front View of OptionalVE-5x5 (not included)Rear View of OptionalVE-5x5 (not included)Optional VE-5x5 Surface Mount Box with black satin powder paint finish, notincluded (DOD 424). Optional VE-LIGHT kit can be used to illuminate the faceplatewhen used with a VE-5x5 (DOD 428). WARNING: Do NOT use a wet location box.The optional VE-5x5 SurfaceMount Box (left) is designed to besurface mounted to a single gangbox, double gang box or VE-GNPGooseneck Pedestal. For moreinformation on the VE-5x5 andVE-GNP, see DOD 424.Important: The E-1600-20-IP willNOT mount to a standard doublegang box. If your applicationsrequires a double gang box, seemodel E-1600A-22-IP on page 10.* Note: The black plastic rough-in box (part # 259576) may be purchased separately (Example: Mounting boxes to studs before thewalls are finished for flush installation). Go to www.vikingelectronics.com and click on “Spare Parts” to order these rough-in boxes.** Caution: When warm air comes in contact with cold surfaces, such as outside walls and conduits, it causes condensation. To preventcondensation from accumulating inside the E-1600-20-IP always bring conduit into the bottom of the unit. If this is not possible, drill a 1/4”diameter hole in the bottom of the black plastic box.9

E-1600-22-IPDimensions: 5.0” x 5.0” x 2.25” (127mm x 127 x 57mm)Mounting in a Double Gang Rough-In Box (not included):Flush into walls, mounts to side of wall studs, etc.Shipping Weight: 2.12 lbs (1.0 lbs)Note: For surface mount installations, use model E-1600-20-IPwith VE-5x5 surface mount box.Front Panel Material: 14 gauge marine grade 316 brushedstainless steelNote: When mounting outside to rough or uneven surfaces(brick, stucco, etc.) apply a bead of clear silicone caulkingaround the top edge and sides of faceplate.Connections: Gel-filled butt connectorsInfo Button: Dials up to 5 non-emergency phone numbersNote: When European CE compliance is required, mount asshown, in a metal enclosure.Optional Enhanced Weather Protection (EWP) Available: EWPproducts are designed to meet IP66 standards and may featurefoam rubber gaskets, sealed connections, gel-filled buttconnectors, as well as potted circuit boards with internally sealed,field-adjustable trim pots and DIP switches for easy onsiteprogramming. For more information on EWP, see DOD 859.Peel paper liner and adhere gasket to back of panel,centering over mounting holes. Caution: For roughsurfaces (ie: brick, stucco, etc.) additional caulking maybe required."Old Work" DoubleGang Rough-In Box*(Example: Allied Molded 9312box shown below, not included)*2.25"DeepMin.(4) T-10 Torx stainlesssteel, flat head, securityscrews and drive bit(included)3.65"WideMin.NECONPHEL2.84"Tall Min.INFOCTEDMarine grade 316 stainlesssteel faceplate and pushbutton switches (sealedper IP67)Grade 2 Braille Label"Help" Push to Call Button(4) Optional DryWall Screws(not included)Call Connected Red LEDEarthGroundEarth Groundthe Green/Yellowwire using theprovided wire nut"Info" ButtonLaser Etched Graphics* CAUTION: Excessive wire length and/or using a rough-in box with inadequate depth can apply force to the circuit boardcausing physical damage.Important: When warm air comes in contact with cold surfaces, such as outside walls and conduits, it causes condensation.To prevent condensation from accumulating inside the E-1600-22-IP always bring conduit into the bottom of the unit. If thisis not possible, drill a 1/4” diameter hole in the bottom of the double gang box.10

E-1600-32-IPDimensions: 5.0” x 5.0” x 2.25” (127mm x 127 x 57mm)Mounting in a Double Gang Rough-In Box (not included):Flush into walls, mounts to side of wall studs, etc.Shipping Weight: 2.12 lbs (1.0 kg)Note: For surface mount installations, use Model E-1600-30-IPwith VE-5x5 surface mount box.Front Panel Material: 14 gauge marine grade 316 brushedstainless steelNote: When mounting outside to rough or uneven surfaces(brick, stucco, etc.) apply a bead of clear silicone caulkingaround the top edge and sides of faceplate.Connections: Gel-filled butt connectorsOptional Enhanced Weather Protection (EWP) Available: EWPproducts are designed to meet IP66 standards and may featurefoam rubber gaskets, sealed connections, gel-filled buttconnectors, as well as potted circuit boards with internally sealed,field-adjustable trim pots and DIP switches for easy onsiteprogramming. For more information on EWP, see DOD 859.Note: When European CE compliance is required, mount asshown, in a metal enclosure.Peel paper liner and adhere gasket to back ofpanel, centering over mounting holes. Caution: Forrough surfaces (ie: brick, stucco, etc.) additionalcaulking may be required."Old Work" DoubleGang Rough-In Box*(Example: Allied Molded 9312box shown below, not included)(4) T-10 Torx stainlesssteel, flat head, securityscrews and drive bit(included)*2.25"DeepMin.Call Connected Red LED3.65"WideMin.NE CCONCall2.84"Tall Min.TEDMarine grade 316stainless steel faceplateand push button switches(sealed per IP67)"Help" Push to Call ButtonLaser Etched Graphics(4) OptionalDry WallScrews(not included)EarthGroundEarth Groundthe Green/Yellowwire using theprovided wire nutBL-1 grade 2 blackBraille label includedPUSH FORHELP2.20VIKING 2.40* CAUTION: Excessive wire length and/or using a rough-in box with inadequate depth can apply force to the circuit boardcausing physical damage.Important: When warm air comes in contact with cold surfaces, such as outside walls and conduits, it causes condensation.To prevent condensation from accumulating inside the E-1600-32-IP always bring conduit into the bottom of the unit. If thisis not possible, drill a 1/4” diameter hole in the bottom of the double gang box.11

E-1600-30-IPDimensions: Overall - 5.0” x 5.0” x 2.25” (127mm x 127 x57mm), Plastic Electrical Box - 4.0” x 4.0” x 2.14” (102mm x102mm x 54mm)Mounting with Plastic Rough-In Box (included): Flush intowalls, mounts to side of wall studMounting with Optional VE-5x5: Surface mount to walls, singlegang boxes, double gang boxes, posts, or to a Viking Gooseneckpedestal.Shipping Weight: 2.12 lbs (1.0 kg)Front Panel Material: 14 gauge marine grade 316 brushedstainless steel** Important: Optional Braille “Push for Help” label should beadhered to the faceplate in ADA applications. Clean surface withisopropyl alcohol, peel off backing and press firmly to the frontpanel in location as shown.Connections: Gel-filled butt connectorsOptional Enhanced Weather Protection (EWP) Available: EWPproducts are designed to meet IP66 standards and may featurefoam rubber gaskets, sealed connections, gel-filled butt connectors,as well as potted circuit boards with internally sealed, fieldadjustable trim pots and DIP switches for easy onsite programming.For more information on EWP, see DOD 859.Note: When European CE compliance is required, mount inoptional VE-5X5 metal enclosure.2.1”* Front View ofPlastic Rough-InBox (included)Peel paper liner and adhere gasketto back of panel, centering overmounting holes. Caution: For roughsurfaces (ie: brick, stucco, etc.)additional caulking may be required.4.0"(4) T-10 Torx stainless steel,flat head, security screwsand drive bit (included)Wall Stud** Wireknock outLaser Etched GraphicsTEDNECCON(2) Standardflat head drywall (sheetrock) screws(not included) OR Call Connected Red LEDMarine grade 316 stainlesssteel faceplate and push buttonswitches (sealed per IP67)Earth Ground theGreen/Yellowwire using theprovided wire nutPush to Call ButtonEarthGroundCondensation Drain Hole** Optional Braille Label5.22”3.25”(4) 0.38” diameter(for gooseneckpedestal mounting)(2) 0.2 x 0.43 slots for single gang box(4) 0.2 x 0.43 slots for double gang boxCondensationDrain Hole5.14”3.0” 3.3”***(2) 0.74"diameter3.0”2.25”Front View of OptionalVE-5x5 (not included)Rear View of OptionalVE-5x5 (not included)Optional VE-5x5 Surface Mount Box with black satin powder paint finish, notincluded (DOD 424). Optional VE-LIGHT kit can be used to illuminate the faceplatewhen used with a VE-5x5 (DOD 428). WARNING: Do NOT use a wet location box.The optional VE-5x5 SurfaceMount Box (left) is designed to besurface mounted to a single gangbox, double gang box or VE-GNPGooseneck Pedestal. For moreinformation on the VE-5x5 andVE-GNP, see DOD 424.Important: The E-1600-30-IP willNOT mount to a standard doublegang box. If your applicationsrequires a double gang box, seemodel E-1600A-32-IP on page 11.* Note: The black plastic rough-in box (part # 259576) may be purchased separately (Example: Mounting boxes to studs before thewalls are finished for flush installation). Go to www.vikingelectronics.com and click on “Spare Parts” to order these rough-in boxes.*** Caution: When warm air comes in contact with cold surfaces, such as outside walls and conduits, it causes condensation. To preventcondensation from accumulating inside the E-1600-30-IP always bring conduit into the bottom of the unit. If this is not possible, drill a 1/4”diameter hole in the bottom of the black plastic box.12

E-1600-50-IP / E-1600-52-IPThis is a E-1600-IP Emergency Phone “parts kits” without achassis. It is specifically designed to be used behind customelevator panels or with custom elevator phones. Just like allViking ADA Compliant Emergency Phones, these kitsprovide quick and reliable handsfree communication in theevent of an emergency.Optional Enhanced Weather Protection (EWP) Available:EWP products are designed to meet IP66 standards andmay feature foam rubber gaskets, sealed connections, gelfilled butt connectors, as well as potted circuit boards withinternally sealed, field-adjustable trim pots and DIP switchesfor easy onsite programming. For more information on EWP,see DOD 859.Note: When European CE compliance is required, mountin a metal enclosure.Shipping Weight: 1.0 lb (0.45 kg)Connections: Gel-filled butt connectorsStandard MicMountingBoot(2) 0.10 diametermounting holes.47 .785Mic HoleSpeaker(included).50Speaker Gasket(EWP only)Screen (included)2.602.10EWP e: Mic holes should be nearthe bottom of the boot to allowfor drainage.EWP Mic Mounting Boot: Glueto the back of your panel at anupward angle (shown left) behinda 0.10” - 0.25” diameter hole.1.0(4) 0.335 x 0.177 mountingslots for #4 or #6 studsStandard Mic Mounting Boot: Glueor screw directly behind 0.04” - 0.125”diameter hole in panel.Panel(2) 0.156 diametermounting holes2.10Relay OutputContactsMylar Speaker DimensionsConnect to "INFO" button(E-1600-52-IP only, requires a0.75" diameter mounting hole)Gray (N.C.)Blue (COM)Yellow (N.O.)Red3.50(3.58EWP)RedConnect to "PUSH FOR HELP" or"HELP" button (requires a 0.75"diameter mounting hole)BlackBlackRed (LED anode)EWP versionis connected andencapsulatedBlack (LED cathode)Clear Spacer Red RetainingLensLEDRingRed call connected LED with mounting hardware(requires a 0.250" diameter mounting hole).3.20BL-1 grade 2 blackBraille label includedPUSH FORHELPVIKING 2.40130.63(0.67EWP)1.52.0(2.04 EWP)0.15(0.19EWP)2.63(2.71 EWP)2.200.60(0.80 EWP)maximumSide View

E-1600-53-IPThis is a E-1600-IP board (PCB) only kit. This kit can be used to convert 2008or newer Viking 1600A Series Analog Emergency Phones to a VoIP version. Aspecial connector and microphone assembly is required to convert 2007 andolder Viking 1600A Series Emergency Phones. Contact Viking Technical Supportif attempting to install this kit in these older phones. This kit can also be used toreplace a damaged “IP” board in the field.Shipping Weight: 1.0 lb (0.45 kg)Connections: (1) RJ45 10/100 Base-T, (3) optional gel-filled buttconnectorsNote: When European CE compliance is required, mount in ametal enclosure.3.503.200.15(2) 0.156 diametertype 2 mounting holes2.02.631.50.6331101Connector and Wires fromExisting Standard (non EWP)1600A Series

1600A-Series phone to a VoIP version Model: E-1600-55-IP HxWxD: 5.0 x 5.0 x 2.0 Description: Universal emergency phone kit to install behind elevator panels or when a custom panel is used Model: E-1600-TP-IPEWP HxWxD: 11.75 x 9.5 x 2.0 Mounting: Flush mount Description: Direct physical replacement for Talk-A-Phone models ETP-400V or VoIP-500