1600 W Ste TM1 Ctn Wall 1 - MOD4 Distribution

Transcription

JUNE, 20151600 Wall SystemTM1 Curtain Wall Kawneer Company, Inc., 2014Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.Laws and building and safety codes governing the design and use of glazedentrance, window, and curtain wall products vary widely. Kawneer does not controlthe selection of product configurations, operating hardware, or glazing materials,and assumes no responsibility therefor.EC 97911-0751FEATURESFeatures 1600 Wall SystemTM1 is an outside glazed captured curtain wall 1600 Wall SystemTM1 has a 2-1/2" (63.5) sight line Standard 6" (152.4) or 7-1/2" (190.5) depth systems Standard infill options 1/4" (6.4) and 1" (25.4), other infills available Thermally Broken by means of a continuous 1/4" (6.4) low conductance spacer Concealed fastener joinery creates smooth, monolithic appearance Open-back horizontals and perimeters are available for cost savings Shear block fabrication method Corners and splayed mullions available Offers integrated entrance framing systems Silicone compatible glazing materials for long-lasting seals 1600 Wall SystemTM1 has been small and large missile impact and cycle tested Two color option PermanodicTM anodized finishes in seven choices Painted finishes in standard and custom choicesOptional Features Steel reinforcing available Rain screen and backpans Optional deep profile and bull nose covers available Deep and heavy-weight mullions available Fiberglass pressure plates available Veneer system available Integrates with standard Kawneer windows and GLASSventTM for curtain wall Integrates with VersoleilTM Sunshade Outrigger System and Horizontal or Vertical SingleBlade System Integrates with 1600 PowerShadeTM Profit MakerTM plus die sets available Hurricane impact resistant framing options: 7-1/16" (179.4), 7-13/16" (198.4), 10-1/16" (255.6)& 10-13/16" (274.6)Product Applications Ideal for low to mid-rise applications where high performance is desired It also is the right choice for high span applicationsFor specific product applications,Consult your Kawneer representative.kawneer.comADMD010

Laws and building and safety codes governing the design and use of glazedentrance, window, and curtain wall products vary widely. Kawneer does not controlthe selection of product configurations, operating hardware, or glazing materials,and assumes no responsibility therefor.1600 Wall SystemTM1 Curtain WallBLANK PAGEADMD010kawneer.com Kawneer Company, Inc., 2014Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.2JUNE, 2015EC 97911-075

JUNE, 20151600 Wall SystemTM1 Curtain WallEC 97911-0753INDEXPICTORIAL VIEW. 51" INFILL DETAILS. 61/4" INFILL DETAILS. 7ENTRANCE DETAILS. 8,9CORNERS. 10SPLAYED MULLION OPTIONS. 11GLASSventTM FOR CURTAIN WALL/WINDOWS. 12BACKPAN AND MISCELLANEOUS DETAILS. 13MISCELLANEOUS FRAMING. 14HURRICANE IMPACT RESISTANT DETAILS. 15,16ANCHORING. 17,18WIND LOAD CHARTS. 19-27DEADLOAD CHARTS. 28-30THERMAL CHARTS . 31-43LAWS AND BUILDING AND SAFETY CODES GOVERNING THE DESIGN AND USE OF GLAZED ENTRANCE,WINDOW, AND CURTAIN WALL PRODUCTS VARY WIDELY. KAWNEER DOES NOT CONTROL THESELECTION OF PRODUCT CONFIGURATIONS, OPERATING HARDWARE, OR GLAZING MATERIALS,AND ASSUMES NO RESPONSIBILITY THEREFOR.Metric (SI) conversion figures are included throughout these details for reference. Numbers in parentheses() are millimeters unless otherwise noted. Kawneer Company, Inc., 2014Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.Laws and building and safety codes governing the design and use of glazedentrance, window, and curtain wall products vary widely. Kawneer does not controlthe selection of product configurations, operating hardware, or glazing materials,and assumes no responsibility therefor.Architects - Most extrusion and window types illustrated in this catalog are standard products for Kawneer. These concepts have been expandedand modified to afford you design freedom. Some miscellaneous details are non-standard and are intended to demonstrate how the system can bemodified to expand design flexibility. Please contact your Kawneer representative for further assistance.The following metric (SI ) units are found in these details:m – metercm – centimetermm – millimeters – secondPa – pascalMPa – megapascalKawneer reserves the right to change configurations without prior notice when deemed necessary for productimprovement.kawneer.comADMD010

Laws and building and safety codes governing the design and use of glazedentrance, window, and curtain wall products vary widely. Kawneer does not controlthe selection of product configurations, operating hardware, or glazing materials,and assumes no responsibility therefor.1600 Wall SystemTM1 Curtain WallBLANK PAGEADMD010kawneer.com Kawneer Company, Inc., 2014Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.4JUNE, 2015EC 97911-075

Kawneer Company, Inc., 2014Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.Laws and building and safety codes governing the design and use of glazedentrance, window, and curtain wall products vary widely. Kawneer does not controlthe selection of product configurations, operating hardware, or glazing materials,and assumes no responsibility therefor.JUNE, 2015kawneer.com1600 Wall SystemTM1 Curtain WallEC 97911-075PICTORIAL VIEWADMD0105

9A7134751A88A66A89ADMD010238A49BOPTIONAL STEELREINFORCINGAS REQUIRED56A6kawneer.com Kawneer Company, Inc., 20141" INFILL DETAILSLaws and building and safety codes governing the design and use of glazedentrance, window, and curtain wall products vary widely. Kawneer does not controlthe selection of product configurations, operating hardware, or glazing materials,and assumes no responsibility therefor.1600 Wall SystemTM1 Curtain WallKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.ELEVATION IS NUMBER KEYED TO DETAILS2-1/2"(63.5)99A9B7-1/2" (190.5)26" (152.4)6JUNE, 2015EC 97911-075SCALE 3" 1'-0"11A6" (152.4)7 -1/2" (190.5)2-1/2"(63.5)

Kawneer Company, Inc., 2014Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.Laws and building and safety codes governing the design and use of glazedentrance, window, and curtain wall products vary widely. Kawneer does not controlthe selection of product configurations, operating hardware, or glazing materials,and assumes no responsibility therefor.ELEVATION IS NUMBER KEYED TO 3.5)6 -3/4" (171.5)77A7B5-1/4" (133.4)JUNE, 20151600 Wall SystemTM1 Curtain WallEC 97911-0751/4" INFILL DETAILSSCALE 3" 1'-0"11A21366A41A55A25-1/4" (133.4)6 -3/4" (171.5)737BOPTIONAL STEELREINFORCINGAS REQUIRED45A57

1600 Wall SystemTM1 Curtain Wall8JUNE, 2015ENTRANCE DETAILS (1" INFILL)EC 97911-075SCALE 3" 1'-0"11A35246TRANSOM BARB/H OR O/PC/HBUTT HUNG OROFFSET PIVOT WITHSURFACE CLOSEROR FLOOR CLOSERB/H OR O/PELEVATION IS NUMBER KEYED TO DETAILS1ADOOR JAMB1-15/16"(88.9)TYP.BUTT HUNG OROFFSET PIVOT2Laws and building and safety codes governing the design and use of glazedentrance, window, and curtain wall products vary widely. Kawneer does not controlthe selection of product configurations, operating hardware, or glazing materials,and assumes no responsibility therefor.1TRANSOM BARBUTT HUNG OR OFFSET PIVOTWITH SINGLE ACTINGCONCEALED OVERHEAD CLOSER3CENTER HUNG4TRANSOM BARCENTER HUNGCONCEALED OVERHEADOR FLOOR CLOSERDOOR JAMBBUTT HUNG OROFFSET PIVOT56TRANSOM BARBUTT HUNG OR OFFSET PIVOTWITH LCN CONCEALEDOVER HEAD CLOSEROR SURFACE CLOSERADMD010kawneer.com Kawneer Company, Inc., 2014DOOR JAMBKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.3/4"(19)TYP.

1600 Wall SystemTM1 Curtain WallJUNE, 2015EC 97911-0759ENTRANCE DETAILS (1/4" INFILL)SCALE 3" 1'-0"Laws and building and safety codes governing the design and use of glazedentrance, window, and curtain wall products vary widely. Kawneer does not controlthe selection of product configurations, operating hardware, or glazing materials,and assumes no responsibility therefor.11A324B/H OR O/P1TRANSOM BARC/HBUTT HUNG OROFFSET PIVOT WITHSURFACE CLOSEROR FLOOR CLOSERELEVATION IS NUMBER KEYED TO DETAILSDOOR JAMBBUTT HUNG OROFFSET PIVOTTRANSOM BARBUTT HUNG OR OFFSET PIVOTWITH SINGLE ACTINGCONCEALED OVERHEAD CLOSER3/4"(19.1)TYP.DOOR JAMBCENTER HUNG Kawneer Company, Inc., 2014Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.1-15/16"(88.9)TYP.21A34TRANSOM BARCENTER HUNGCONCEALED OVERHEADOR FLOOR CLOSERkawneer.comADMD010

90 OUTSIDE CORNER90 INSIDE CORNER90 OUTSIDE CORNER135 OUTSIDE CORNER135 OUTSIDE CORNER135 INSIDE CORNERADMD010kawneer.com Kawneer Company, Inc., 2014CORNERSLaws and building and safety codes governing the design and use of glazedentrance, window, and curtain wall products vary widely. Kawneer does not controlthe selection of product configurations, operating hardware, or glazing materials,and assumes no responsibility therefor.1600 Wall SystemTM1 Curtain WallKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.10JUNE, 2015EC 97911-075SCALE 3" 1'-0"NOTE: 1" SYSTEM SHOWN, 1/4" SYSTEM SIMILAR.

Kawneer Company, Inc., 2014Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.Laws and building and safety codes governing the design and use of glazedentrance, window, and curtain wall products vary widely. Kawneer does not controlthe selection of product configurations, operating hardware, or glazing materials,and assumes no responsibility therefor.JUNE, 2015kawneer.com1600 Wall SystemTM1 Curtain WallEC 97911-075SPLAYED MULLION OPTIONSSCALE 3" 1'-0"0 TO 5 0 TO 5 5 TO 15 5 TO 15 INSIDE SPLAYED MULLIONSADMD01015 TO 25 OUTSIDE SPLAYED MULLIONS15 TO 25 11

FOR CURTAIN WALL/WINDOWSGLASSventTM FOR CURTAIN WALLHEADSILLJAMB8225TL THERMAL WINDOWSNOTE: Other vent types can be accommodated. Contact yourKawneer representative for other options.HEADSILLJAMBADMD010kawneer.com Kawneer Company, Inc., 2014GLASSventTMLaws and building and safety codes governing the design and use of glazedentrance, window, and curtain wall products vary widely. Kawneer does not controlthe selection of product configurations, operating hardware, or glazing materials,and assumes no responsibility therefor.1600 Wall SystemTM1 Curtain WallKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.12JUNE, 2015EC 97911-075SCALE 3" 1'-0"

Kawneer Company, Inc., 2014Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.kawneer.com673ELEVATION IS NUMBER KEYED TO DETAILSNOTE: 6" SYSTEM SHOWN, 7-1/2" SYSTEM SIMILAR1JAMB MULLIONAT SPANDREL(With vapor barrier tie-in)3THERMALLY BROKENDOOR ADAPTORFOR INSULCLAD DOORS1/2" (12.7)2D.L.O.13/8" (9.5)2-1/2" (63.5)3/8" (9.5)D.L.O.MULLION LENGTHCONSTRUCTION JOINT1/2" (12.7) MAX (ALLOWS /-1/4" MOVEMENT)5MULLION LENGTHLaws and building and safety codes governing the design and use of glazedentrance, window, and curtain wall products vary widely. Kawneer does not controlthe selection of product configurations, operating hardware, or glazing materials,and assumes no responsibility therefor.JUNE, 20151600 Wall SystemTM1 Curtain WallEC 97911-075BACKPAN AND MISCELLANEOUS DETAILSSCALE 3" 1'-0"44HEAD TRANSOM AT PARAPET FLASHING5EXPANSION JOINT26MULLION AT SPANDRELTYPICAL DEADLOAD ANCHOR37AATM 250 THERMAL DOORTRANSOM – SPANDREL OVER VISIONADMD01013

1600 Wall SystemTM1 Curtain Wall14JUNE, 2015MISCELLANEOUS FRAMINGEC 97911-075SCALE 3" ON 7-1/2"(190.5)6"(152.4)Laws and building and safety codes governing the design and use of glazedentrance, window, and curtain wall products vary widely. Kawneer does not controlthe selection of product configurations, operating hardware, or glazing materials,and assumes no responsibility therefor.Architects – Most extrusion and window types illustrated in this catalog are standard products for Kawneer. These concepts have been expanded andmodified to afford you design freedom. Some miscellaneous details are non-standard and are intended to demonstrate how the system can be modifiedto expand design flexibility. Please contact your Kawneer representative for further assistance.4"(101.6)OPTIONALFIBERGLASSPRESSURE PLATE2-1/2"(63.5)OPTIONAL COVERS4" SIGHT LINE2-1/2"(63.5)DOUBLE MULLIONVENEER SYSTEM069263GYPSUM BOARD TRIM2-1/2"(63.5)DEEP MULLIONSTOOL TRIM OPTIONS:069264 - 2-3/4" (69.9)069265 - 4-1/2" (114.3)069266 - 5" (127.0)069267 - 6-1/8" (155.6)069268 - 6-3/4" (171.4)NOTE:STOOL TRIMS REQUIRE 069271 TRIM CLIP PACKAGEINTERIOR STOOL TRIMADMD010kawneer.com Kawneer Company, Inc., eer reserves the right to change configuration without prior notice when deemednecessary for product OPTIONAL COVERS

3-19/32"(91.3) Kawneer Company, Inc., 2014Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.EC 97911-075SCALE 3" 1'-0"55Akawneer.com7568ELEVATION IS NUMBER KEYED TO DETAILSEXPANSIONHORIZONTALOPTIONAL STEELREINFORCINGAS REQUIREDADMD0102-3/4"(69.9)2-1/2"(63.5)Laws and building and safety codes governing the design and use of glazedentrance, window, and curtain wall products vary widely. Kawneer does not controlthe selection of product configurations, operating hardware, or glazing materials,and assumes no responsibility therefor.JUNE, 20151600 Wall SystemTM1 Curtain Wall31063-19/32"(91.3)15HURRICANE IMPACT RESISTANT DETAILSNOTE: DETAILS SHOWN WITH 9/16" INFILL AND ARE GLAZED FOR FOR LARGE MISSLE IMPACT (LMI).SEE NEXT PAGE FOR OTHER GLAZING OPTIONS.1217-1/16"(179.4)2943475A

1600 Wall SystemTM1 Curtain WallJUNE, 2015EC 97911-075HURRICANE IMPACT RESISTANT DETAILSSCALE 3" 1'-0"NOTE: 350 IR DOORS ARE USED WITH IMPACT FRAMING.DOORS ARE GLAZED WITH 9/16" INFILL.897-1/16"(179.4)DOOR JAMBAT MULLION9/16" INFILLLARGE MISSILE (LMI)DOOR JAMBAT 0" DEEP SYSTEM1-5/16" INFILLLARGE MISSILE (LMI)2-1/2"(63.5)2-1/2"(63.5)1-5/16" INFILLSMALL MISSILE (SMI)2-1/2"(63.5)9/16" INFILL (SMI)SMALL MISSILEIMPACT2-1/2"(63.5)GLAZING OPTIONS7-13/16"(198.4)7-1/16"(179.4)9/16" INFILLSMALL MISSILE (SMI)OVER9/16" INFILLLARGE MISSILE (LMI)1-5/16" INFILLLARGE MISSILE (LMI)ADMD010kawneer.com Kawneer Company, Inc., 201410TRANSOM BAR9/16" INFILLLARGE MISSILE (LMI)Kawneer reserves the right to change configuration without prior notice when deemednecessary for product 3/4"(44.5)1/8"2-1/2"(63.5)OPTIONAL10" DEEP SYSTEM9/16" INFILLLARGE MISSILE (LMI)10-13/16"(274.6)2-1/2"(63.5)Laws and building and safety codes governing the design and use of glazedentrance, window, and curtain wall products vary widely. Kawneer does not controlthe selection of product configurations, operating hardware, or glazing materials,and assumes no responsibility therefor.16

Kawneer Company, Inc., 2014Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.Laws and building and safety codes governing the design and use of glazedentrance, window, and curtain wall products vary widely. Kawneer does not controlthe selection of product configurations, operating hardware, or glazing materials,and assumes no responsibility therefor.JUNE, 2015kawneer.com1600 Wall SystemTM1 Curtain WallEC 97911-075ANCHORINGActual project conditions will determine specific anchor design. Details on this page are for reference only.1" (25.4) MINIMUMANCHORING TO FLOOR SLAB1" (25.4) MINIMUMANCHORING TO SUPPORT STEELADMD01017

1" (25.4) MINIMUMANCHORING TO HORIZONTALSTRUCTURAL STEEL1" (25.4) MINIMUMANCHORING TO VERTICALSTRUCTURAL STEELADMD010kawneer.com Kawneer Company, Inc., 2014ANCHORINGLaws and building and safety codes governing the design and use of glazedentrance, window, and curtain wall products vary widely. Kawneer does not controlthe selection of product configurations, operating hardware, or glazing materials,and assumes no responsibility therefor.1600 Wall SystemTM1 Curtain WallKawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.18JUNE, 2015EC 97911-075Actual project conditions will determine specific anchor design. Details on this page are for reference only.

JUNE, 20151600 Wall SystemTM1 Curtain WallEC 97911-07519WIND LOAD / DEADLOAD CHARTSMullions are designed for deflection limitations in accordance with AAMA TIR-A11 of L/175 up to 13'-6" and L/240 1/4"above 13'-6". These curves are for mullions WITH HORIZONTALS and are based on engineering calculations for stressand deflection. Allowable wind load stress for ALUMINUM 15,152 psi (104MPa), STEEL 30,000 psi (207MPa.). Chartedcurves, in all cases are for the limiting value. Wind load charts contained herein are based upon nominal wind loadutilized in allowable stress design. To convert ultimate wind loads to nominal loads, multiply ultimate wind loads by afactor of 0.6 per ASCE/SEI 7. A 4/3 increase in allowable stress has not been used to develop these curves. For specialsituations not covered by these curves, contact your Kawneer representative for additional information.DEADLOAD CHARTSHorizontal or deadload limitations are based upon 1/8" (3.2), maximum allowable deflection at the center of anintermediate horizontal member. The accompanying charts are calculated for 1" (25.4) thick insulating glass or 1/4" (6.4)thick glass supported on two setting blocks placed at the loading points shown. Kawneer Company, Inc., 2014Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.Laws and building and safety codes governing the design and use of glazedentrance, window, and curtain wall products vary widely. Kawneer does not controlthe selection of product configurations, operating hardware, or glazing materials,and assumes no responsibility therefor.WIND LOAD CHARTSkawneer.comADMD010

1600 Wall SystemTM1 Curtain Wall20JUNE, 2015WIND LOAD CHARTS (1" INFILL)SINGLE SPAN11.52723TWIN SPANA 20 PSF (960)B 30 PSF (1440)C 40 PSF (1920)D 50 PSF (2400)E 60 PSF (2880)METERS.5EC 514413601234567MULLION CENTERS IN FEETI 5.035(209.57 x 104)S 1.993(32.66 x 103)812012SINGLE SPAN145678TWIN SPANMETERSMETERS.53MULLION CENTERS IN 107.524C237226.521D20619E185.5173D9MULLION HEIGHT IN FEET4.514MULLION HEIGHTEQUALEQUAL15METERS56" (152.4)1716B25MULLION HEIGHT18MULLION HEIGHT IN 8METERS21I 6.779(282.16 x 104)S 2.652(43.46 x 103)MULLION CENTERS IN FEET12012345678MULLION CENTERS IN FEETADMD010kawneer.com Kawneer Company, Inc., 2014117.524Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.12MULLION HEIGHT IN FEET15METERS5166" (152.4)17MULLION HEIGHTEQUALEQUAL25MULLION HEIGHT188METERS2028Laws and building and safety codes governing the design and use of glazedentrance, window, and curtain wall products vary widely. Kawneer does not controlthe selection of product configurations, operating hardware, or glazing materials,and assumes no responsibility therefor.2921MULLION HEIGHT IN FEET1.59225130

1600 Wall SystemTM1 Curtain WallJUNE, 2015EC 97911-075WIND LOAD CHARTS (1" INFILL)A 20 PSF (960)B 30 PSF (1440)C 40 PSF (1920)D 50 PSF (2400)E 60 PSF (2880)SINGLE SPANMETERS.52111.52723TWIN C123.5D11E10MULLION HEIGHT IN FEET15METERS5167-1/2" (190.5)17MULLION HEIGHTEQUALEQUAL25MULLION 1620037212345674.51441360I 10.135(421.85 x 104)S 3.027(49.60 x 103)81201234567MULLION CENTERS IN FEETMULLION CENTERS IN FEETSINGLE SPANTWIN 521202868265.54.5B134C12D3.511E10MULLION HEIGHT IN FEETA14MULLION HEIGHTEQUALEQUAL15METERS57-1/2" (190.5)1716D25MULLION HEIGHT18MULLION HEIGHT IN 5162004724.51441365B012345678I 12.736(530.11 x 104)S 3.791(62.12 x 103)MULLION CENTERS IN FEETkawneer.com1201234567MULLION CENTERS IN FEETADMD0108METERS22 Kawneer Company, Inc., 2014Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.2921MULLION HEIGHT IN FEETLaws and building and safety codes governing the design and use of glazedentrance, window, and curtain wall products vary widely. Kawneer does not controlthe selection of product configurations, operating hardware, or glazing materials,and assumes no responsibility therefor.22

1600 Wall SystemTM1 Curtain Wall22JUNE, 2015WIND LOAD CHARTS (1" INFILL)SINGLE SPANMETERS11.5SINGLE SPANA 20 PSF (960)B 30 PSF (1440)C 40 PSF (1920)D 50 PSF (2400)E 60 PSF (2880)162004 W/162300.5EC 97911-075230162004 W/162301METERS.511.523099288.525MULLION HEIGHT723226.521A206B1918MULLION HEIGHT IN 162301Ia 12.736(530.11 x 104)Sa 3.791(62.12 x 103)Is 3.805(158.37 x 104)Ss 1.669(27.35 x 103)Ia 12.736(530.11 x 104)Sa 3.791(62.12 x 103)Is 5.684(236.59 x 104)Ss 2.493(40.85 x 103)5E154.5144131201234567MULLION CENTERS IN FEETMULLION CENTERS IN FEETSINGLE SPANSINGLE SPAN162004 W/162301/302162004 92928288.527826256.521B619C187-1/2" (190.5)7A2220MULLION HEIGHT24MULLION HEIGHT IN FEET7.523826METERSMULLION HEIGHT IN 004W/162301/302/303Ia 12.736(530.11 x 104)Sa 3.791(62.12 x 103)Is 7.893(328.53 x 104)Ss 3.462(56.73 x 103)Ia 12.736(530.11 x 104)Sa 3.791(62.12 x 103)Is 9.347(389.05 x 104)Ss 4.100(67.19 x 103)MULLION CENTERS IN 7METERSMULLION HEIGHT IN LION CENTERS IN FEETADMD010kawneer.com Kawneer Company, Inc., 20142827Laws and building and safety codes governing the design and use of glazedentrance, window, and curtain wall products vary widely. Kawneer does not controlthe selection of product configurations, operating hardware, or glazing materials,and assumes no responsibility therefor.29Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.29

Kawneer Company, Inc., 2014Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.MULLION HEIGHT IN FEETLaws and building and safety codes governing the design and use of glazedentrance, window, and curtain wall products vary widely. Kawneer does not controlthe selection of product configurations, operating hardware, or glazing materials,and assumes no responsibility therefor.SINGLE 1817D16E4566C5.5151347MULLION CENTERS IN FEET810-1/2" (266.7)28MULLION HEIGHT.5METERSJUNE, 20151600 Wall SystemTM1 Curtain WallEC 97911-075WIND LOAD CHARTS (1" INFILL)A 20 PSF (960)B 30 PSF (1440)C 40 PSF (1920)D 50 PSF (2400)E 60 PSF (2880)28.5278247.575144.5162064I 42.441(1766.52 x 104)S 8.816(144.74 x 103)ADMD01023

1600 Wall SystemTM1 Curtain Wall24JUNE, 2015WIND LOAD CHARTS (1/4" INFILL)A 20 PSF (960)B 30 PSF (1440)C 40 PSF (1920)D 50 PSF (2400)E 60 PSF (2880)SINGLE SPANMETERS.511.52723EC 97911-075TWIN SPANMETERS.511.5230922285.5413125-1/4" (133.4)3.511A103B9CD8E7MULLION HEIGHT IN FEET4.514MULLION 5D5E154.514162013272316217.524172.56082517MULLION HEIGHT18MULLION HEIGHT IN FEETA268413I 3.662(152.42 x 104)S 1.662(27.24 x 103)12012345678MULLION CENTERS IN FEETMULLION CENTERS IN FEETSINGLE SPANTWIN 1620141C221520723162.567.52417E7MULLION HEIGHT IN FEET4.514MULLION HEIGHTEQUALEQUAL15METERS5165-1/4" (133.4)178B25MULLION HEIGHT18MULLION HEIGHT IN FEETA261958.527METERS21I 4.5071(87.60 x 104)S 1.968(32.25 x 103)MULLION CENTERS IN FEET41312012345678MULLION CENTERS IN FEETADMD010kawneer.com Kawneer Company, Inc., 201461958.527METERS20Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.6.521Laws and building and safety codes governing the design and use of glazedentrance, window, and curtain wall products vary widely. Kawneer does not controlthe selection of product configurations, operating hardware, or glazing materials,and assumes no responsibility therefor.29

1600 Wall SystemTM1 Curtain WallJUNE, 2015EC 97911-075WIND LOAD CHARTS (1/4" INFILL)SINGLE SPAN.511.52723TWIN SPANA 20 PSF (960)B 30 PSF (1440)C 40 PSF (1920)D 50 PSF (2400)E 60 PSF 34B12C113.5D103MULLION HEIGHT IN FEET4.5A146-3/4" (171.5)15METERS516MULLION HEIGHTEQUALEQUAL2517MULLION HEIGHT182.5720619D185.5E51620151351245674.514I 7.915(329.45 x 104)S 2.635(43.18 x LION CENTERS IN FEETMULLION CENTERS IN FEETSINGLE SPANTWIN SPANMETERS.51METERS21MULLION HEIGHT IN FEETLaws and building and safety codes governing the design and use of glazedentrance, window, and curtain wall products vary widely. Kawneer does not controlthe selection of product configurations, operating hardware, or glazing materials,and assumes no responsibility 276826195.5B134C123.511D103EMULLION HEIGHT IN FEET4.5A14MULLION HEIGHTEQUALEQUAL15METERS56-3/4" (171.5)1716C25MULLION HEIGHT18MULLION HEIGHT IN 62016135I 9.594(399.33 x 104)S 3.163(51.83 x 103)12012345678MULLION CENTERS IN FEETkawneer.com4.514401234567MULLION CENTERS IN FEETADMD0108METERS22 Kawneer Company, Inc., 2014Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.25

1600 Wall SystemTM1 Curtain Wall26JUNE, 2015WIND LOAD CHARTS (1/4" INFILL)SINGLE SPANMETERS11.5SINGLE SPANA 20 PSF (960)B 30 PSF (1440)C 40 PSF (1920)D 50 PSF (2400)E 60 PSF (2880)162016 W/162300.5EC 97911-075230162016 W/162301METERS.511.523099288.525MULLION A20B619185.5C4456751614137.52417C1615MULLION HEIGHT IN FEET7.524METERS8162016W/162300162016W/162301Ia 9.594(399.33 x 104)Sa 3.163(51.83 x 103)Is 3.805(158.37 x 104)Ss 1.669(27.35 x 103)Ia 9.594(399.33 x 104)Sa 3.163(51.83 x 103)Is 5.684(236.59 x 104)Ss 2.493(40.85 x 103)D154.5E1441312012345678MULLION CENTERS IN FEETMULLION CENTERS IN FEETSINGLE SPANSINGLE SPAN162016 W/162301/302162016 2928288.5278266.52120B61918MULLION HEIGHT IN FEET7A6-3/4" (171.5)MULLION HEIGHT24225.5CA257.523826METERSMULLION HEIGHT IN 62301/302/303Ia 9.594(399.33 x 104)Sa 3.163(51.83 x 103)Is 7.893(328.53 x 104)Ss 3.462(56.73 x 103)Ia 9.594(399.33 x 104)Sa 3.163(51.83 x 103)Is 9.347(389.05 x 104)Ss 4.100(67.19 x 103)MULLION CENTERS IN FEETMETERSMULLION HEIGHT IN ION CENTERS IN FEETADMD010kawneer.com Kawneer Company, Inc., 20142827Laws and building and safety codes governing the design and use of glazedentrance, window, and curtain wall products vary widely. Kawneer does not controlthe selection of product configurations, operating hardware, or glazing materials,and assumes no responsibility therefor.29Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.29

Kawneer Company, Inc., 2014Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.MULLION HEIGHT IN FEETLaws and building and safety codes governing the design and use of glazedentrance, window, and curtain wall products vary widely. Kawneer does not controlthe selection of product configurations, operating hardware, or glazing materials,and assumes no responsi

1600 W Ste TM1 Ctn Wall 1 JUNE, 2015 ADMD010 FEATURES For specific product applications, Consult your Kawneer representative. Features 1600 Wall System TM1 is an outside glazed captured curtain wall 1600 Wall System TM1 has a 2-1/2" (63.5) sight line Standard 6" (152.4) or 7-1/2" (190.5) depth systems