Carlon Flex-Plus Blue Electrical Nonmetallic Tubing (ENT . - Carlon Sales

Transcription

Carlon Flex-Plus BlueElectrical NonmetallicTubing (ENT) and Accessories ENT TubingAdapters& CouplingsMud BoxAssembliesStub DownsOutlet andSwitch BoxesGross Automation (877) 268-3700 · www.carlonsales.com · sales@grossautomation.com

Table of ContentsContentsCarlon Flex-Plus Blue Electrical Nonmetallic Tubing (ENT) and AccessoriesFlex-Plus Blue ENT . 3Stub Downs . 4Mud Box Assemblies. 5Mounting Brackets . 6ENT Bridge. 6Transition Adapters . 7Outlet and Switch Boxes - Eccentric Knockouts . 8Outlet Box Divider. 8Quick Connect Adapters & Couplings . 9Schedule 40 Adapters and Couplings . 92 1/2" & 4" Mud Boxes and Covers . 10Quick Connect Outlet and Switch Boxes . 10ENT Box with Adapters . 11ENT Box Extenders . 11Round Covers for Octagon Ceiling Boxes. 11Quick Connect 4" Octagon Ceiling Boxes . 12HOLFORM Concrete Sleeves . 12PVC Conduit Cutters. 13Tape . 13Carlon Cement . 13Concrete Encasement Guidelines . 14Specifications . 14Features . 15Approved Uses . 15Typical Applications . 152w w w. c a r l o n . c o mGross Automation (877) 268-3700 · www.carlonsales.com · sales@grossautomation.com

Flex-Plus Blue ENTFlex-Plus Blue ENTOptions:is a nonmetallic flexible raceway for usein walls, floors, and non-plenum ceilings.It’s lightweight, hand bendable, and freefrom sharp edges, which reducesinstallation time and saves money.E73317 Sizes 1/2" through 2" Colors:Yellow color for communicationcircuits and signaling cableRed color for fire alarm circuitsBlue color for power circuits Packaging: Coils or ReelsSee pages 31–32 for technicalinformation.Standard Stock – Reels1/2"3/4"1"Nom.I.D.Nom.O.D.PullTapeMin. BendRadiusReel Size(F x W)Reel Type(W Wood)ReelLengthReel Wt.(lbs.)Wt. per100 ft. (lbs.)12005AK-001.56.84Empty6"36" x 24"W15004010Yellow1205AKY-001.56.84Empty6"36" x 24"W15004010Red1205AKR-001.56.84Empty6"36" x 24"W15004010Blue12007AA-001.761.05Empty6"36" x 24"W10004014Yellow1207AAY-001.761.05Empty.6"36" x 24"W10004014Red1207AAR-001.761.05Empty6"36" x 24"W10004014Blue12008-7501.001.315Empty6"36" x 24"W7504020ColorPart No.BlueYellow12008Y-7501.001.315Empty6"36" x 24"W7504020Red12008R-7501.001.315Empty6"36" x 48" x 32"W7509019Empty81/4"48" x 32"W7509039Yellow12010Y-7501.5541.90Empty81/4"48" x 32"W75090392"Blue12011-5002.0302.375Empty91/2"48" x 32"W5009032Red12011R-5002.0302.375Empty91/2"48" x 32"W5009032Empty91/2"48" x .0302.375*1-1/4" - 2" available in yellow & red, made to order; consult factory.Standard Stock – Coils1/2"3/4"1"ColorPart No.Nom.I.D.Nom.O.D.PullTapeMin. BendRadiusCoil Length Wt. per(ft.)100 ft. "1002210 ft. LengthsColorPart No.Std. Ctn. Qty.Std. Ctn. Wt. (lbs.)/"/"Blue12005-UPC.56.8410 ft.1.02Blue12007-UPC.761.0510 ft.1.461"Blue12008-0101.001.31510 ft.2.931 23 4Nom. I.D.Nom. O.D.NOTE: The solid blue color of ENT conduit is a registered trademark of Carlon.ENT may show color deterioration in direct sunlight over an extended period of time. It is suggested that all ENT products not be stored outside.Since this product is not intended for use outdoors, it should not be exposed to extended periods of direct sunlight.w w w. c a r l o n . c o mGross Automation (877) 268-3700 · www.carlonsales.com · sales@grossautomation.com3

Accessories - Stub DownsStub DownsVertical Stub DownCarlon Vertical Stub Downs are designed to provide a quick, easy connection to a wood deck or transitionfrom slab-to-slab using Carlon’s “Quick Connect” snap-in design simply snap the ENT in place. The integral snapsprovide a secure mount – preventing the ENT from pulling out while maintaining the ability for easy removal of thefitting once the deck is removed. All in a concrete tight application. The underside of this fitting provides ampleroom to attach a Carlon coupling to the ENT to continue the run. Carlon Vertical Stub Downs are manufactured outof a highly engineered thermoplastic material to provide extra strength and durability, and are available in sizes1/2", 3/4" and 1".Part. No.SizeStd. Ctn. Qty.Std. Ctn. Wt. lbs.A210D1/2"503.8A210E3/4"503.7A210F1"504.8Patent PendingVertical Stub Down Transition AdapterCARLON NONMETALLIC EXCLUSIVE Carlon Vertical Stub Down Transition Adapters like ourVertical Stub Downs, provide a means to transition from ENT to another wire management product where coderequires other wire management means i.e. “area of physical damage” (ref. NEC 352.12C). The integral snapsprovide a secure mount – preventing the ENT from slipping or pulling out, while the deck mount flange has athreaded port allowing connection to other conduit system using a terminal adapter. Carlon Vertical Stub DownTransition Adapters are manufactured out of polycarbonate material to provide extra strength and durability. They’reconcrete tight, and available in sizes 1/2", 3/4" and 1".Part. No.SizeStd. Ctn. Qty.Std. Ctn. Wt. lbs.Female ENT to NPSC (Female)502.3Female ENT to NPSC (Female)502.81" Female ENT to NPSC (Female)503.9A200D1/2"A200E3/4"A200FE8672045 Stub DownCarlon 45 Degree Stub Downs are designed to allow a smooth transition from cross deck ENT runs to verticalapplications. The integral snaps provide a secure mount – preventing the ENT from slipping or pulling out- but alsoallow the stub to easily be removed. The underside of this fitting provides ample room to attach a Carlon coupling tothe ENT to continue the run. Carlon 45 Degree Stub Downs are manufactured out of a highly engineered thermoplasticmaterial to provide extra strength and durability. They’re concrete tight, and available in sizes 1/2", 3/4" and 1".Part. No.SizeStd. Ctn. Qty.Std. Ctn. Wt. lbs.A220D1/2"251.8A220E3/4"252.0A220F1"252.6Patent Pending90 Stub Down Transition AdapterCARLON NONMETALLIC EXCLUSIVE Carlon 90 Degree Stub Downs are designed to allow a smoothtransition from cross deck ENT runs to vertical applications where code requires other wire management means, i.e.“area of physical damage” (ref. NEC 352.12C). The integral snaps provide a secure mount – preventing the ENT fromslipping or pulling out, while the deck mount flange has a threaded port allowing connection to any conduit systemusing a terminal adapter. Carlon 90 Degree Stub Downs are manufactured out of polycarbonate material to provideextra strength and durability. They’re concrete tight, and available in sizes 1/2", 3/4" and 1".Part. No.Std. Ctn. Qty.Std. Ctn. Wt. lbs.A230D1/2"Female ENT to NPSC (Female)252.0A230E3/4"Female ENT to NPSC (Female)252.41" Female ENT to NPSC (Female)253.3A230F4Sizew w w. c a r l o n . c o mGross Automation (877) 268-3700 · www.carlonsales.com · sales@grossautomation.comE86720

Accessories - Mud Box AssembliesMud Box AssembliesE42728E42728Except where noted by tCemesncapdincludeCarlon Mud Box Assemblies are available in five unique styles blank, ceiling ring, one-gang,two-gang and 4 square. All Mud Box Assemblies are manufactured out of polycarbonate material toprovide extra strength and durability, are concrete tight, and have twelve integral connectors two-1",six-3/4", and four-1/2". Using our new ENT Reducers, this product will meet ANY jobsite application.Mud Box Base with Blank CoverSizeStd. Ctn. Qty.Std. Ctn. Wt. lbs.A863BCMud Box w/ Blank Cover2412.3 Part. No.Patent PendingMud Box with Ceiling Ring Threaded brass inserts for fan (#10-32 screws) and fixture (#8-32 screws) mountings Listed for fixture support up to 50 lbs. Listed for ceiling fans up to 35 lbs.Part. No. A863CFA863CFGSizeStd. Ctn. Qty.Std. Ctn. Wt. lbs.Mud Box w/ Ceiling Ring2415.5Mud Box w/ Ceiling Ring & Ground Lug2416.1Patent PendingMud Box with One-Gang RingSizeStd. Ctn. Qty.Std. Ctn. Wt. lbs.A863SMud Box w/ One-Gang Ring2416.8Mud Box w/ One-Gang Ring & Ground Lug2416.2SizeStd. Ctn. Qty.Std. Ctn. Wt. lbs.Mud Box w/ Two-Gang Ring2415.8Mud Box w/ Two-Gang Ring & Ground Lug2416.6 Part. No.A863SGPatent PendingMud Box with Two-Gang RingPart. No. A863DA863DGPatent PendingMud Box with 4 Square Ring 4 Square Ring not for luminaries. Part. No.SizeStd. Ctn. Qty.Std. Ctn. Wt. lbs.A863-4SQMud Box w/ 4 Inch Square Ring2415.2Patent PendingNEWMudBox Assemblies with Mounting FeetCarlon Mud Box Assemblies w/ Mounting Feet are specifically engineered and designed for use in Tunnel Form applications. Themounting feet are located on all four corners and allow the box to attach directly to the wall of the form using pop rivets. Thepop rivets help keep the box in position during the pour and provide a safe, secure, and rust resistant mount.Part. SGFSizeStd. Ctn. Qty.Std. Ctn. Wt. lbs.4-Square Ring2417.15Ceiling Ring2416.61Ceiling Ring and Ground Lug2417.46Double Gang2417.42Double Gang and Ground Lug2417.99Single Gang2417.15Single Gang and Ground Lug2417.44Patent Pendingw w w. c a r l o n . c o mGross Automation (877) 268-3700 · www.carlonsales.com · sales@grossautomation.com5

Accessories - Mounting Brackets and ENT BridgeMounting BracketsBack ViewFront ViewCARLON EXCLUSIVE The Carlon ENT Mounting Bracket is specifically designed for use with CarlonENT Mud Box Assemblies in vertical concrete walls where one- or two-gang boxes are needed. The stainless steelspring-loaded mechanism provides a secure outlet box between concrete forms while the soft steel strap allows forthe outlet box to be secured to rebar. The bracket combination assures a straight box opening and a concrete tightfit. Mud Box not included.Part. No.SizeStd. Ctn. Qty.Std. Ctn. Wt. lbs.A863MBMud Box Mounting Kit1.98Patent PendingENT BridgeCARLON EXCLUSIVE The Carlon ENT Bridge is designed to support long ENT runs in concrete pourapplications. This makes pulling wire/cable a snap. Installation is easy simply mount the ENT bridge, using nailsor screws, to the wood deck mounting and snap the ENT into place. The bridge is designed to hold the conduit inplace while minimizing dips in the conduit over long runs. The Carlon ENT Bridge is manufactured out of a highlyengineered thermoplastic material to provide extra strength and durability, and can accommodate ENT sizes1 2", 3 4", and 1".Part. No.SizeStd. Ctn. Qty.Std. Ctn. Wt. lbs.A293DEFENT Bridge509.0Patent Pending6w w w. c a r l o n . c o mGross Automation (877) 268-3700 · www.carlonsales.com · sales@grossautomation.com

Accessories - AdaptersTransition AdaptersMale ENT to Schedule 40 & 80 PVC ConduitCARLON EXCLUSIVE Carlon Male ENT to Schedule 40 & 80 PVC Conduit Transition Adaptersare designed to connect Schedule 40 conduit to Carlon Flex-Plus Blue ENT boxes and fittings. Simply solventcement the PVC adapter to the Schedule 40 conduit and snap the adapter into the Carlon’s “Quick Connect” snapin connector on the box or fitting. Carlon Male ENT to Schedule 40 & 80 Adapters are concrete tight and availablein sizes 1/2", 3/4" and 1".Part. No.SizeA263D1/2"A263E3/4"A263FENT to1/2"ENT to3/4"Std. Ctn. Qty.Std. Ctn. Wt. lbs.Sch. 40 or Sch. 801002.4Sch. 40 or Sch. 801003.21004.51" ENT to 1" Sch. 40 or Sch. 80E32447Patent PendingENT to EMTCarlon ENT to EMT Transition Adapters are designed to easily transition from Carlon Flex-Plus Blue ENTto EMT using Carlon’s “Quick Connect” snap-in design. The EMT is held securely in place using the small screwprovided. This helps prevent the EMT from slipping/shifting out of the adapter. All ENT to EMT adapters aremanufactured out of polycarbonate material to provide extra strength and durability. They’re concrete tight, andavailable in sizes 1/2", 3/4" and 1".Part. No.Std. Ctn. Qty.Std. Ctn. Wt. lbs.A245D1/2"ENT to 1/2" EMT1003.4A245E3/4"ENT to 3/4" EMT1004.11005.4A245FSize1" ENT to 1" EMTE86720ReducersCARLON EXCLUSIVE Carlon ENT Reducers are designed to provide an easy transition from 1" Carlon ENTto 3/4" ENT or from 3/4" Carlon ENT to 1/2" ENT. They’re concrete tight, and manufactured out of polycarbonatematerial to provide extra strength and durability. Carlon ENT Reducers provide flexibility while on the jobsite byminimizing the need to carry size specific boxes and fittings. Carlon ENT Reducers provide the versatility to convertCarlon fittings and boxes to many different sizes and configurations.Part. No.A273DEA273EFSizeStd. Ctn. Qty.Std. Ctn. Wt. lbs.to 1/2"1003.21" to 3/4"1002.43/4"E86720Patent Pendingw w w. c a r l o n . c o mGross Automation (877) 268-3700 · www.carlonsales.com · sales@grossautomation.com7

Accessories - Outlet and Switch BoxesOutlet and Switch Boxes - Eccentric KnockoutsCarlon ENT Outlet and Switch Boxes with Eccentric Knockouts are designed to allow selective ENTopenings – 1/2", 3/4" and 1" – based on application needs. They provide the largest capacity available in themarket today - 22 cu. in. Single Gang, and 38 cu. in. Double Gang – and can be mounted to wood or steel studs.Carlon ENT Outlet and Switch Boxes with Eccentric Knockouts are manufactured out of a highly engineeredthermoplastic material to provide extra strength and durability, and are available in single gang and double gangstyles. Note: The double gang version is also a 4 square box.Single Gang – 22 cu. in.Part. No.SizeCapacity Cu. in.Std. Ctn. Qty.Std. Ctn. Wt. lbs.A122Single-Gang22256.8Patent PendingCombination Two Gang/Four Square Box – 38 cu. in.Part. No.SizeCapacity Cu. in.Std. Ctn. Qty.Std. Ctn. Wt. lbs.A238Two-Gang38258.9Patent PendingOutlet Box DividerCarlon ENT Outlet Box Divider is specifically designed for applications where a combined high and lowvoltage closed back box is needed such as placement in a fire-rated wall. Just slip the divider into place, to give youthe split box you need. The Carlon ENT Outlet Box Divider is UL Recognized for use with Carlon A238 Box only.8Part. No.SizeStd. Ctn. Qty.Std. Ctn. Wt. lbs.A238DIV–501.87w w w. c a r l o n . c o mGross Automation (877) 268-3700 · www.carlonsales.com · sales@grossautomation.comE42728

Accessories - CouplingsQuick Connect Adapters & Couplings Carlon one piece ENT Quick Connect Couplings, Threaded Adaptersand Snap-In Terminator Adapters are suitable for damp locations.Quick Connect Couplings and Threaded Adapters are concrete-tightwhen used with Carlon ENT. All Schedule 40 fittings are compatible with ENT when using ENTcement.LR92248E86720 Schedule 40 fittings are recommended for use with Carlon 1 1/4" –2" Flex-Plus Blue ENT. Use of ENT Blue Quick-Set Cement is required. See page 13 for details. When One Piece Quick Connect Snap-In Terminator Adapters areinstalled in a concrete application, Carlon’s flat sealing washers mustbe used on the box connection ends.CouplingsPart. No.SizeA240DA240EA240F1/2"Standard CartonQuantityStandard CartonWeight (lbs.)150100502.903.002.30Standard CartonQuantityStandard CartonWeight (lbs.)150100502.552.302.00Standard CartonQuantityStandard CartonWeight (lbs.)150100502.702.902.303/4"1"Threaded AdaptersPart. No.SizeA243DA243EA243F1/2"3/4"1"Snap-In AdaptersPart. No.SizeA253DA253EA253F1/2"3/4"1"Schedule 40 Adapters and CouplingsE32447Standard CouplingsMale Terminal AdaptersAll socket fittings should be attached Using Carlon solvent cement. UsingCarlon fittings with Carlon nonmetallic conduit insures system integrity.For adapting nonmetallicconduits to boxes,threaded fittings, metallicsystems. Male threadson one end, socket endon other.PartNo.Std.Ctn.Size Qty.ABTypicalMin.DMax.ODSocket type forjoining nonmetallicconduit.CSTypicalLStd.Ctn. F1501.3301.3101.01815/8111/161 25/323E943G11/4501.6771.6551.33221/3213/41 15/164E943H11/2251.9181.8941.5662 5/3213/163/421/162.5E943J2502.3932.3692.0002 21/32 15/1615/8163/642 15/642 47/64TypicalCLTypical11/163/415/16111/813/16w w w. c a r l o n . c o mGross Automation (877) 268-3700 · www.carlonsales.com · Ctn.Wt. (lbs.)4.14.43.53.53.95.259

Accessories - Mud Boxes, Outlet & Switch Boxes2 1/2" & 4" Mud Boxes and CoversLR31146E42728Base RingsListed for use with ceiling fans up to35 lbs. and for fixture supportup to 50 lbs.Part.No.SizeA861Without ground lugCA861GCoversPart.No.Size2.5A862D2 1/2" Deep (1/2" KO’s)102.52.0A862E2 1/2" Deep (3/4" KO’s)102.1A864D4" Deep (1/2" KO’s)102.9A864E4" Deep (3/4" KO’s)102.9A864F4" Deep (1" KO’s)103.0Std. Ctn. Std. Ctn.Qty.Wt.10With ground lug10Std. Ctn. Std. Ctn.Qty.Wt.Quick Connect Outlet and Switch Boxes Suitable for masonry walls Meets NEMA OS-2E42728Single Gang – 16 cu. in.Standard CartonQuantityStandard CartonWeight (lbs.)3 x 21/4 x 3 (1/2" KO’s)254.63 x 21/4 x 3 (3/4" KO’s)254.6Standard CartonQuantityStandard CartonWeight (lbs.)Part. No.DescriptionA58381DA58381E4 Inch Square – 20 cu. in.Part. No.DescriptionA52151D4 x 4 x 11/2 (1/2" KO’s)10022.6A52151E4 x 4 x 11/2 (3/4" KO’s)10022.610022.6Standard CartonQuantityStandard CartonWeight (lbs.)257.6A521DE4x4x11/ 2(1/2"&3/4"KO’s)4 Inch Square – 30.3 cu. in.10Part. No.DescriptionA52171D4 x 4 x 23/8 (1/2" KO’s)4 x 23 / 8(3/4"A52171E4xA5217DE4 x 4 x 23/8 (1/2" & 3/4" KO’s)KO’s)257.6257.6w w w. c a r l o n . c o mGross Automation (877) 268-3700 · www.carlonsales.com · sales@grossautomation.com

AccessoriesE42728 Except where noted by ENT Box with Adapters4 Inch Square – 24.75 cu. in. ENT Box with AdaptersPart. No.DescriptionA5329DE4 x 4 x 13/4 (1/2" & 3/4" KO’s)Standard CartonQuantityStandard CartonWeight (lbs.)5014.8Standard CartonQuantityStandard CartonWeight (lbs.)1002.1Box Back Wall Support Part. No.DescriptionA540DSFor use with 1/2" KnockoutENT Box ExtendersE42728Single GangPart. No.RiseCu. in.Standard CartonQuantityStandard CartonWeight 505.1A4131"6.6405A41411/ 4"8.1304.4Part. No.RiseCu. in.Standard CartonQuantityStandard CartonWeight 04.2A4223/4"8.8504.8Two GangRound Covers for Octagon Ceiling BoxesE42728Round Plaster Rings Suitable for fixture supportPart. No.RiseCu. in.Standard CartonQuantityStandard CartonWeight (lbs.)A4711/2"3.21003.3A4723/4"4.01003.7Standard CartonQuantityStandard CartonWeight (lbs.)Round Blank CoversPart. No.E460R-CARA470DRiseCu. in.Blank-352.2Blank with 1/2" KO-1006.2w w w. c a r l o n . c o mGross Automation (877) 268-3700 · www.carlonsales.com · sales@grossautomation.com11

AccessoriesQuick Connect 4" Octagon Ceiling Boxes Carlon ceiling boxes and round plaster rings are produced from a special high heatresistant engineered plastic material developed specifically for fixture support. Listed for fixture support up to 50 lbs. E42728Except wherenoted byCeiling Box – 20.5 cu. in.Part. No.DescriptionA615D4 - 21/8" Deep (1/2" KO’s)&3/4"KO’s)Standard CartonQuantityStandard CartonWeight (lbs.)506.4506.4506.4Ceiling Box with J Mount – 20.5 cu. in.Part. No.DescriptionA615DJ4 - 21/8" Deep (1/2" KO’s)Standard CartonQuantityStandard CartonWeight (lbs.)5018.7Ceiling Box with L Bracket – 20.5 cu. in.Part. No.DescriptionA615DL4 - 21/8" Deep (1/2" KO’s)Standard CartonQuantityStandard CartonWeight (lbs.)506.4Ceiling Box with Adjustable Hanger Bar – 20.5 cu. in.Adjust from 14 1/4" to 23 1/4"Part. No.DescriptionA615DH4 - 21/8" Deep (1/2" KO’s)Standard CartonQuantityStandard CartonWeight (lbs.)2513.6HOLFORM Concrete SleevesHOLFORM nonmetallic concrete sleeve forms are the easy way to form holes in concrete. They installin seconds with nails, screws or staples and are easily removed. Concrete will not adhere to them.HOLFORMS are adjustable to any slab thickness.Min.O.D.ABStd.Ctn.Qty.Std.Ctn.Wt. (lbs.)E92CSH11/213/4203E92CSJ22 13/32256E92CSL33 13/32258E92CSN44 13/32188E92CSP55 13/32158E92CSR66 13/32128Part No. 12w w w. c a r l o n . c o mGross Automation (877) 268-3700 · www.carlonsales.com · sales@grossautomation.com

AccessoriesPVC Conduit CuttersMedium CutterSmall CutterHand held cutter makes fast square, smoothfield cuts on conduit, sizes 1/2" through 11/4".Produces burr-free cut with no shavings.Fits into pocket or pouch.For fast, smooth field cuts of1/2" through 1" Flex-Plus Blue ENT.Part No.CC120BSize8"Std.Ctn. Qty.10TapeLarge CutterPart No.CC125Size9"Std.Ctn. Qty.12For clean cuts of conduit, sizes1/2" through 2".Std.Size Ctn. Qty.17 1/2"1Part No.CC122Prelubricated, woven polyester tape made from low friction, high abrasion resistant yarnsproviding a low coefficient of friction. Tape is printed with sequential footage markings foraccurate measurements.Part. No.SizeTL145051/2"Tensile StrengthReel Lengths1250 lbs.5,000 ft.TL145101/2"1250 lbs.10,000 ft.TL382035/8"1800 lbs.3,000 ft.TL382655/8"1800 lbs.6,500 ft.TL382105/8"1800 lbs.10,000 ft.Other tapes are available. Consult your sales service location for additional information.Carlon Cement(MSDS sheets available at www.carlon.com)*Meets ASTM D2564All-Weather ENT Blue“Quick-Set” SolventCement with brush*PartNo.SizeStd.Ctn. ontemperatureRecommended pipeapplication and sizesSet-up time(Evaporation Rate)Recommended for usewith Flex-Plus Blue ENT(Electrical NonmetallicTubing), Riser-Gard ,P&C Flex , and CarlonPVC fittings.Up through 4" diameter.10 -30 F 4-5 minutes4 to 100 F30 -50 F 3-4 minutes50 -70 F 1-2 minutes70 -90 F 1/2-11/2 minutesLap Shear@ 73 FViscosity at75 asmanufactured2 hrs. 350 psi400-700 cps16 hrs. 800 psi72 hrs. 1,500 psiENT cement required for use with ENTw w w. c a r l o n . c o mGross Automation (877) 268-3700 · www.carlonsales.com · sales@grossautomation.com13

Technical InformationConcrete Encasement Guidelines1. Cut ENT square and cleanly.2. Insert end into fitting, making sure two (2) fullcorrugations are snapped into fitting beyondflexible tabs (2 clicks).3. ENT should be tied to rebar at 2-3 foot intervalsto prevent flotation. Keep ENT straight. Smalldeflections over a long run may accumulatesignificant degrees of bend which will affectconductor installation. Suitable materialsinclude wire, tie wraps, and tape.4. When using UL solvent weld fittings forconcrete tight performance:E. Promptly insert ENTinto fitting whilecement is wet, untilthe stop is reached,and give a quarterturn.F. Do not disturb untiljoint is set.A. Do not use chemical primer or cleaner.B. Apply a light, uniform coat of cementlabeled for use with ENT on the couplingand ENT.C. Do not use a dauber.D. Brush excess cement out of ENT grooves.Specifications1.1 Electrical Nonmetallic Tubing (ENT), is designed to replace EMT, flexible metal conduit or other raceway orcable systems, for installation in accordance with Article 362 of the National Electrical Code, other applicablesections of the Code, and local codes.1.2 Any ENT used shall meet the requirements of UL Standard UL 1653 and shall be listed by UnderwritersLaboratories, Inc., as suitable for its intended purpose.1.3 ENT shall be recognized by a National Evaluation Report for use in 1-hour and 2-hour rated construction.1.4 Penetration of fire rated walls, floors or ceilings shall use classified Through-Penetration Firestop Systemsdescribed in the current Underwriters Laboratories Fire Resistance Directory.1.5 Fittings and outlet boxes shall be designed for use with ENT and listed by Underwriters Laboratories. Allfittings, boxes and accessories shall be from one manufacturer.1.6 Only Carlon ENT Blue cement recommended specifically for use with ENT shall be used.1.7 Unless indicated differently on drawings, ENT systems shall be color coded: BLUE for branch and feeder circuitwiring, YELLOW for communications, and RED for fire alarm and emergency systems.1.8 ENT, fittings, and accessories shall be manufactured by Carlon.14w w w. c a r l o n . c o mGross Automation (877) 268-3700 · www.carlonsales.com · sales@grossautomation.com

Technical InformationFeatures UL recognizes the use of PVC RNC cement type fittings with all sizes of ENT ENT rated for 90 deg C conductors One piece ENT Coupling, Threaded Terminator and RNC Transition Fitting are rated concrete tightwithout tape by UL Recognized for use in 2-hour fire resistive nonload bearing and load bearing wall assemblies Recognized for use in 1-hour fire resistive nonload bearing wall assemblies Recognized for use in a fire resistive ceiling assembly (up to 3 hours) Recognized for Through-Penetration Firestop systems as classified by UL to meet BOCA, SBCCI and ICBO codes. Conductors easily push through the raceway (up to approximately 50 feet)* For use in buildings in accordance with NEC Article 362 Approved for installations of a one and two hour fire rated wall assembly and up to a three hour ratedfloor/ceiling assembly Outside Diameters meet IPS Dimensions Storage-4 F to 158 F Handling-4 F to 104 FApproved Uses: Concrete slab – NEC Article 362 Walls - wood stud, masonry and metal stud – NEC Article 362. Ceilings - permanent or dropped (free air only) – NEC Article 362. Exposed – NEC Article 362 Public Assembly – NEC Section 518.4, in nonfire rated and certain five rated structures Prewired – NEC Article 362 Classified by UL 1479 for Through Penetration Firestop Systems in UL Guide Category XHEZ and currentUL Fire Resistance Directory Three hour rated floor/ceiling assemble Raised Floors – NEC Section 645.5(D)(2) Exposed or concealed in building above three floors when a fire sprinkler system is installed in accordance withNFPA 13 – NEC Section 362.10(2) For use in residential attics up to 3 feet above the bottom of the ceiling joist.Typical Applications: Residential: Low or high rise – multi or single family Commercial: Low or high rise – office, retail, hotel/motel, restaurant, etc. Nursing Homes/Hospitals in nonpatient care areas only Schools, classrooms, dormitories, offices Fire Alarm Systems Recreational vehicles and parks Solar Photovoltaic systems Marinas and boatyards Other uses per the current NECw w w. c a r l o n . c o mGross Automation (877) 268-3700 · www.carlonsales.com · sales@grossautomation.com15

2B43 5M 10/06 SP Lamson & Sessions 2006Gross Automation (877) 268-3700 · www.carlonsales.com · sales@grossautomation.com

from slab-to-slab using Carlon's "Quick Connect" snap-in design simply snap the ENT in place. The integral snaps provide a secure mount - preventing the ENT from pulling out while maintaining the ability for easy removal of the fitting once the deck is removed. All in a concrete tight application. The underside of this fitting .