For the latest prices, please check AutomationDirect.com.DL105ProgrammableLogic Controllers(PLC)Up-to-date price list:www.automationdirect.com/pricelistFREE Technical Support:www.automationdirect.com/supportFREE Videos:www.automationdirect.com/videosFREE Documentation:In this interactive PDF you can: Use bookmarks to navigateby product categorywww.automationdirect.com/documentationFREE CAD drawings:www.automationdirect.com/cad Use bookmarks to save,search, print or e-mail thecatalog section Click on part #s to linkdirectly to our online storefor current pricing, specs,stocking information andmorewww.automationdirect.com/dl105DL105 PLCsmDL1-1

DL105For the latest prices, please check AutomationDirect.com.Micro PLCWhat is it?The DL105 series is a fixed-I/Omicro PLC with 10 inputs and 8outputs. Eight configurations areavailable in combinations of AC,DC and relay I/O, as well as AC orDC powered models.What’s it got? 10 inputs and 8 outputs 2K program memory 384 words data memory 110/220 VAC or 24 VDC powered models Built-in 24 VDC auxiliary power supply for field devices included with AC powered models 91-instruction programming, includes time or event-based drum sequencer, timedinterrupt, immediate I/O, etc. One RS-232C communication portWhat can I do with it? Build an electronic drum sequencer with 18 I/O points and connect an operator interface Drive high-current (up to seven amps) loads with the AC/relay model Use the high-speed I/O modes of a DC input or output model to perform counting orpositioning tasksVisit our Web page at http://www.automationdirect.com/dl105 for more informationmDL1-2DL105 PLCs1-800-633-0405

For the latest prices, please check AutomationDirect.com.CompanyInformationControl SystemsOverviewIt’s not the smallest micro, but it willput a big smile on your face!CLICK PLCDo-MorePLCs OverviewThe DL105 has 18 I/O points, high current capability, and removable I/Oconnectors. These features, plus heavy-duty power supply design and built-insurge suppression on the relay outputs, still make the DL105 one of the mostversatile fixed-I/O units in the market.Do-More H2PLCDo-More T1HPLCAC inputs and high current AC outputsDirectLOGICPLCs OverviewGreat for higher current applications, our AC outputs are rated at 1.6 A perpoint.DirectLOGICDL05/06Seven amp relaysDirectLOGICDL105We used powerful 7A relays and combined them with a design thatsheds heat! The DL105 offers eight relay outputs that can support up toseven amps per point. (You can drive all eight outputs at six amps per point upto 60 C.) Compare this to the 2.5 A of other micro PLCs.DirectLOGICDL205DirectLOGICDL305Removable connectorsDirectLOGICDL405The DL05 was one of the first micro PLCs to offer removable terminal blocks.This feature makes wiring and installation a lot easier and less time ty3000UniversalField I/OSoftwareC-MoreHMIC-More MicroHMIViewMarqIndustrialMarqueesOther HMICommunicationsAppendixBook 1Terms andConditionswww.automationdirect.com/dl105DL105 PLCsmDL1-3

For the latest prices, please check AutomationDirect.com.Features and SpecificationsThe DL105 micro PLCs contain theCPU, power supply and I/O all in thesame housing. If you examine the CPUSpecifications table, you’ll see that weincluded many features found in ourmodular CPUs.Review the specsMake sure these features can satisfy therequirements of your application. Sincethese units are completely self-contained,you cannot expand the system or replacethe CPU as you would in a modular system.System capacitySystem capacity is the ability to accommodate a variety of applications. For laddermemory, most Boolean instructions requireone word. Some other instructions, such astimers, counters, etc., require two or morewords. Our V‑memory words are useful fordata storage, etc.AC-powered unitsF1-130AA10 AC inputs, 8 AC outputs, 1.7 A/pointSystem capacityF1-130ADTotal memory available (words) 2.4KLadder memory (words) 2,048 EEPROMV-memory (words) 384User V 256Non-volatile user V 128Battery backup NoTotal I/O 18Inputs 10Outputs 8I/O expansion No10 AC inputs, 8 DC outputs, 1.0 A/point, two outputs can beused as 7 kHz pulse output, 0.5 A/pointF1-130AR10 AC inputs, 8 relay outputs, 7 A/pointF1-130DA10 DC inputs, 4 inputs are filtered inputs, can also be configured as a single 5 kHz high-speed counter, interrupt input, orpulse catch input8 AC outputs, 1.7 A/pointF1-130DD10 DC inputs, 4 points are filtered inputs, can also be configured as a single 5 kHz high-speed counter, interrupt input, orpulse catch input8 DC outputs, 1.0 A/point, 2 outputs can be used as 7 kHzpulse output, 0.5 A/pointF1-130DR10 DC inputs, 4 inputs are filtered inputs, can also be configured as a single 5 kHz high-speed counter, interrupt input, orpulse catch input8 relay outputs, 7 A/pointDC-powered unitsPerformanceF1-130DD-DThe performance is simply the scan time,which is the amount of time required toread the inputs, solve the RLL program andupdate the outputs.F1-130DR-DInstructions and diagnosticsMake sure the unit offers the instructionsyou need.CommunicationsAll DL105 units offer one RS-232 port,capable of 9,600 baud.DL105 CPU Specifications10 DC inputs, 4 inputs can be used as 5 kHz high-speed counter, interrupt inputs, or pulse catch inputs8 DC outputs, 1.0 A/point, two outputs can be used as 7 kHzpulse output, 0.5 A/point.10 DC inputs, 4 inputs can be used as 5 kHz high-speed counter, interrupt inputs, or pulse catch inputs8 relay outputs, 7 A/pointProgrammingHandheld programmer.D2-HPP 321.00DirectSOFT Programming for WindowsPC-DSOFT6 . 395.00PC-DS100 FreePC-R60-U (upgrade) 249.00Specialty featuresWith the DC input and/or DC outputversions, we also offer several high-speedI/O features.PerformanceContact execution (Boolean) 3.3 µsTypical scan (1K Boolean)1 5-6 msInstructions and diagnosticsRLL ladder style YesRLLPLUS/flowchart style (Stages) Yes/256Run-time editing YesSupports Overrides NoVariable/fixed scan VariableInstructions 91Control relays 256Timers 64Counters 64Immediate I/O YesSubroutines NoFor/next loops NoTimed interrupt . YesInteger math . YesFloating-point math NoPID . NoDrum sequencers YesBit of word NoASCII print . NoReal-time clock/calendar . NoInternal diagnostics YesPassword security Multi-levelSystem and user error log NoCommunicationsBuilt-in ports one, RS-232-CK-sequence (proprietary protocol) YesDirectNET NoMODBUS master/slave NoASCII out NoBaud rate (fixed) 9,600 baudSpecialty featuresFiltered inputs Yes2Interrupt input Yes2High-speed counter . Yes, 5 kHz2Pulse output Yes, 7 kHz2Pulse catch input Yes2Note: Either high-speed input or pulse outputcan be used, but not in the same configuration.1- Our 1K program includes contacts, coils, and scanoverhead. If you compare our products to others,make sure you include their scan overhead.2- Input features are only available on units with DCinputs. Output features are only available on unitswith DC outputs.tDL1-1DL105 PLCs1-800-633-0405

For the latest prices, please check AutomationDirect.com.DL105 Hardware FeaturesCPU status indicatorsOutput terminalblock (removable)RUN ON CPU is in RUN mode .OFF CPU is in PROGRAM modePWR .ON .CPU power good .OFF CPU power failureCPU .ON CPU internal diagnostics has detected an error .OFF . CPU is OKTerminal coversOutput LEDs6-pin femaleconnectorMode controlThe DL105 units do not have modeswitches like many of our modularCPUs. You can set the unit (using specialV-memory locations) so that it will powerup in RUN mode.Communications portProtocol K-sequence slaveDevices .Can connect with HPP, DirectSOFT, DV-1000, .C-More PanelsSpecs .6P6C RJ12 connector RS-232-C, 9,600 baud, .Odd parity, .Fixed station address (1), 8 data bits (one start, .one stop bit), Asynchronous, half-duplex, DTEAuxiliary 24VDC supply(AC powered units only)Input terminal block(removable)Input LEDsCPU status LEDsRJ12 Connector Port 1 PinoutPin .Signal1 0V2 5V3 RS-232 Data in4 RS-232 Data out5 5V6 0VFixed EEPROM memoryThe DL105 units offer built-in EEPROMmemory.NOTE: Terminals accept 16-24 AWG. For 16 AWG, usetype TFFN or Type MTW. Other types of 16 AWG maybe acceptable, but it really depends on the thicknessof the wire insulation.www.automationdirect.com/dl105DL105 PLCstDL1-2

For the latest prices, please check AutomationDirect.com.Dimensions and InstallationIt is important to understand the installation requirements for your DL105 system.This will help ensure that the DL105 products operate within their environmentaland electrical limits.InstallationPlan for safetyThis catalog should never be used as areplacement for the user manual. The usermanual, D1-USER-M, contains importantsafety information that must be followed.The system installation should comply withall appropriate electrical codes and standards.Unit dimensions andmounting orientationUse the following diagrams to make surethe DL105 system can be installed in yourapplication. DL105 units must be mountedhorizontally to ensure proper airflow forcooling purposes. It is important to checkthese dimensions against the conditions required for your application. Forexample, we recommend that you leave2” depth for ease of access and cableclearance; however, your distance may begreater or less. Also, check the installationguidelines for the recommended cabinetclearances.Temperature probe2"50mmminPower source2"50mmmin2"50mmminPanel ground terminalBus barPanelStar washersGround braidcopper lugsEarthgroundPanel or singlePoint groundNote: There is a minimum of 2” (50mm) clearance required between the panel door or any devices mounted inthe panel door and the nearest DL105 component.Dimensions and mountingEnvironmental SpecificationsStorageTemperature-4ºF to 158ºF (-20ºC to 70ºC)AmbientOperatingTemperature32ºF to 131ºF (0º to tanceNoiseImmunity30% to 95% relative humidity (noncondensing)AtmosphereNo corrosive gasestDL1-3MIL STD 810C, Method 514.2MIL STD810, Method 516.2NEMA(ICS3-304)DL105 PLCsUnits: )1-800-633-0405

For the latest prices, please check AutomationDirect.com.Power Supply and Type of I/OPower supply optionsThis product family offers units thatoperate on 110/220 VAC and 12/24VDC. Choosing the power supply is probably the most important considerationwhen specifying a DL105 system, sincenot all I/O combinations are offered witheach power supply option. The table tothe right provides the I/O choices andpower supply specifications for each typeunit.Choosing the I/OThe DL105 product family offers severaldifferent combinations of I/O points.Once you have chosen the power supplyoption, you need to choose the unit thatoffers the type of I/O points needed inyour application.Fixed I/OAll DL105 Micro PLCs have “fixed”I/O that is updated on every scan. Thismeans that all units have 10 inputs and8 outputs, regardless of the actual type ofpoints on the units (DC in/Relay out, DCin/DC out, etc.) The DL105 micro PLC isnon-expandable, so you cannot add I/Opoints. If you are concerned about futuresystem expansion, check our DL06 (36base I/O expandable to 100 total I/O),or the DL205 micro-modular productfamily. The DL205 also offers a wide arrayof features and flexible I/O arrangementswith several different base sizes.Power Supply OptionsSpecificationAC Powered Units24 VDC Powered UnitsPart NumbersF1-130AA, F1-130ARF1-130AD, F1-130DAF1-130DD, F1-130DRF1-DVNET-AR, F1-DEVNET-DDF1-DVNET-DRF1-130DD-DF1-130DR-DVoltage Withstand (dielectric)one minute @ 1,500 VAC between primary, secondary and fieldgroundInsulation Resistance 10 Mq @ 500 VDCExternal Power Requirement85-132 VAC (110 nominal)170-264 VAC (220 nominal)100-264 VDC (125 nominal)10-30 VDC(12 to 24 VDC)with 10 percent rippleAuxiliary 24 VDC Output500 mA max.Not availableMaximum Inrush Current12 A8AMaximum Power30 VA max.1 A (approx. 10 W)Addresses automaticallyassignedThe DL105 uses automatic addressing,so for the vast majority of applications,there is no setup required. We use octaladdressing for many of our products,which means there are no 8s or 9s.The first eight input points use addressesX0-X7, and the last two input points useX10 and X11. If you plan on using thehigh-speed counting features, there issome very minimal setup required inspecial V-memory locations.AC-powered unitsPart No.I/O MixF1-130AA . 10 Ac in 8 AC outF1-130AD .10 AC in .8 DC outF1-130AR .10 AC in .8 relay outF1-130DA . 10 DC in 8 AC outF1-130DD .10 DC in .8 DC outF1-130DR 10 DC in .8 relay outDC-powered unitsPart No.I/O MixF1-130DD-D 10 DC in .8 DC outF1-130DR-D .10 DC in . 8 relay outAC supplyOutput addressesIndicates group percommon24 VDC auxiliary supply(AC powered units only)www.automationdirect.com/dl105Input addressesDL105 PLCstDL1-4

For the latest prices, please check AutomationDirect.com.DL105 I/O SpecificationsF1-130AAWiring diagramand specificationsOutput point wiring 239.00Power requirementsVoltage range .94-240 VAC (30 VA) 100-240 VDC (30 W)AC input specificationsNumber of input points 10Number of commons .3(isolated)Input voltage range .80-132 VAC 90-150 VDCInput current 6 mA @ 132 VAC .6.8 mA @ 150 VDCON current/voltage level . 4 mA / 80 VAC . 4 mA / 90 VDCOFF current/voltage level 2 mA / 45 VAC . 2 mA / 60 VDCOFF to ON response 8 msON to OFF response 15 msFuses NoneAC output specificationsNumber of output points .8Number of commons .4 (isolated)Output circuitry .TriacOutput voltage range 20-140 VAC 47-63 HzPeak voltage 400 VACON voltage drop 1.3 VAC at 2 AMaximum current 1.7 A/point (subject to derating)Maximum leakage current 1 mA at 400 VACMaximum inrush current 30 A for 10 ms 15 A for 100 msMinimum load 10 mAOFF to ON response 8.33 ms @ 60 Hz 10 ms @ 50 HzOn to OFF response .8.33 ms @ 60 Hz 10 ms @ 50 HzFuses .None (external recommended)Input point wiringEquivalent input circuitEquivalent output circuitAuxiliary 24 VDC OutputVoltage range 21.6 - 26.4 VDCOutput .500 mA max., isolatedRipple .less than 200 mV p - ptDL1-5DL105 PLCsDerating chart for AC inputsDerating chart for AC outputs1-800-633-0405

For the latest prices, please check AutomationDirect.com.DL105 I/O SpecificationsF1-130AD 239.00Wiring diagramand specificationsOutput point wiringPower requirementsVoltage range .94-240 VAC (30 VA) 100-240 VDC (30 W)AC input specificationsNumber of input points 10Number of commons 3 (isolated)Input voltage range .80-132 VAC 90-150 VDCInput current 6 mA @ 132 VAC 6.8 mA @ 150 VDCON current/voltage level . 4 mA / 80 VAC . 4 mA / 90 VDCOFF current/voltage level . 2 mA / 45 VAC 2 mA / 60 VDCOFF to ON response 8 msON to OFF response 15 msFuses NoneInput point wiringDC output specificationsNumber of output points .8 (sinking)Number of commons 3 (internally connected)Output circuitry MOSFETOutput voltage range 5-30 VDCPeak voltage .60 VDCON voltage drop .0.45 VDC @ 0.5 AMaximum current 0.5 A/point (Y0-Y1) 1.0 A/point (Y2-Y7)Maximum leakage current 15 µA at 30 VDCMaximum inrush current 1.5 A for 10 ms (Y0-Y1) 3 A for 10 ms (Y2-Y7)Minimum load .NoneOFF to ON response Y0-Y1: 10 µs .Y2-Y7: 3.5 µsON to OFF response Y0-Y1: 70 µs .Y2-Y7: 110 µsExternal DC power required . 10-30 VDC .@ 30 mA load currentFuses .None (external recommended)Equivalent input circuitEquivalent output circuitTo other circuits in bank V VOutputCommonAuxiliary 24 VDC OutputVoltage range .21.6 - 26.4 VDCOutput 500 mA max., isolatedRipple less than 200 mV p - pwww.automationdirect.com/dl105Derating chart for AC inputsDerating chart for DC outputsDL105 PLCstDL1-6

For the latest prices, please check AutomationDirect.com.DL105 I/O SpecificationsF1-130AR 210.00Wiring diagramand specificationsOutput point wiringPower requirementsVoltage range .94-240 VAC (30 VA) 100-240 VDC (30 W)AC input specificationsNumber of input points .10Number of commons .3 (isolated)Input voltage range .80-132 VAC 90-150 VDCInput current 6 mA @ 132 VAC .6.8 mA @ 150 VDCON current/voltage level . 4 mA / 80 VAC . 4 mA / 90 VDCOFF current/voltage level 2 mA / 45 VAC . 2 mA / 60 VDCOFF to ON response 8 msON to OFF response . 15 msFuses .NoneRelay output specificationsNumber of output points .8Number of commons .4 (isolated).Output circuitry RelayOutput voltage range 12-250 VAC .12-30 VDCMaximum voltage .265 VAC, 150 VDCMaximum current .7 A/point (see derating)Maximum inrush current 12 AMinimum load 10 mAMinimum OFF resistance .100 Mq @ 500 VDCOFF to ON response .15 msON to OFF response .5 msFuses None (external recommended)Input point wiringEquivalent input circuitEquivalent output circuitAuxiliary 24 VDC OutputVoltage range 21.6 - 26.4 VDCOutput .500 mA max., isolatedRipple .less than 200 mV p - pTypical Relay Life (Operations)at Room TemperatureVoltage and Type of LoadLoad Current50 mA5A7A24 VDC Resistive10M600K300K24 VDC Solenoid—150K75K110 VAC Resistive—600K300K110 VAC Solenoid—500K200K220 VAC Resistive—300K150K220 VAC Solenoid—250K100KtDL1-7DL105 PLCsDerating chart for AC inputsDerating chart for Relay outputs1-800-633-0405

For the latest prices, please check AutomationDirect.com.DL105 I/O SpecificationsOutput point wiringF1-130DA 239.00Wiring diagramand specificationsPower requirementsVoltage range .94-240 VAC (30 VA) .100-240 VDC (30 W)DC input specificationsNumber of input points 10 (sink/source)Number of commons .3 (isolated)Input voltage range (X0–X3) 10-26.4 VDC .(X4-X11) 10-26.4 VDC or 21.6–26.4 VACInput impedance 2.8 Kq @ 12 VDC. .2.8 Kq @ 24 VDCON current/voltage level . 3 mA / 9 VDCOFF current/voltage level 0.5 mA / 2 VDC.Response .X0-X3 X4-X11OFF to ON .50 µs 2-8 msON to OFF .50 µs 2-8 msFuses .NoneInput point wiringAC output specificationsNumber of output points .8.Number of commons .4 (isolated).Output circuitry .TriacOutput voltage range 20-140 VAC 47-63 HzPeak voltage 400 VACON voltage drop .1.3 VAC @ 2 AMaximum current .1.7 A/point .(subject to derating)Maximum leakage current .1 mA at 400 VACMaximum inrush current .30 A for 10 ms .15 A for 100 msMinimum load 10 mAOFF to ON response .Y0-Y7: 8.33 ms @ 60 Hz .Y2-Y7: 10 ms @ 50 HzON to OFF response Y0-Y7: 8.33 ms @ 60 Hz .Y2-Y7: 10 ms @ 50 HzFuses .None (external recommended)Equivalent circuithigh-speed inputs (X0-X3)Equivalent circuitstandard inputs (X4-X11)Auxiliary 24 VDC OutputVoltage range .21.6 - 26.4 VDCOutput .500 mA max., isolatedRipple .less than 200 mV p - pDerating chart for DC inputsDerating chart for AC outputsEquivalent output circuitwww.automationdirect.com/dl105DL105 PLCstDL1-8

For the latest prices, please check AutomationDirect.com.DL105 I/O SpecificationsF1-130DDOutput point wiring 239.00Wiring diagramand specificationsPower requirementsVoltage range .94-240 VAC (30 VA) 100-240 VDC (30 W)DC input specificationsNumber of input points 10 (sink/source)Number of commons .3 (isolated)Input voltage range .(X0–X3) 10-26.4 VDC .(X4-X11) 10-26.4 VDC or 21.6–26.4 VACInput impedance 2.8 Kq @ 12-24 VDCON current/voltage level 3 mA / 9 VDCOFF current/voltage level 0.5 mA / 2 VDCOFF to ON response .X0-X3: 50 µs .X4-X11: 2-8 msON to OFF response .X0-X3: 50 µs .X4-X11: 2-8 msFuses .NoneInput point wiringDC output specificationNumber of output points .8 (sinking)Number of commons 3 (internally connected)Output circuitry MOSFETOutput voltage range 5-30 VDCPeak voltage .60 VDCON voltage drop 0.4 VDC @ 0.5 AMaximum current .0.5 A /point (Y0-Y1) .1.0 A /point (Y2-Y7)Maximum leakage current 15 µA at 30 VDCMaximum inrush current .Y0-Y1: 1.5 A for 10 ms .Y2-Y7: 3 A for 10 msMinimum load .NoneOFF to ON response Y0-Y1: 10 µs Y2-Y7: 3.5 µsON to OFF response .Y0-Y1: 70 µs .Y2-Y7: 110 µsExternal DC power required .10-30 VDC, .@ 30 mA load currentFuses .None (external recommended)Derating chart for DC inputsEquivalent circuithigh-speed inputs (X0-X3)Equivalent circuitstandard inputs (X4-X11)Derating chart for DC outputsEquivalent output circuitTo other circuits in bank V VOutputCommontDL1-9DL105 PLCs1-800-633-0405

For the latest prices, please check AutomationDirect.com.DL105 I/O SpecificationsF1-130DR 199.00Output point wiringWiring diagramand specificationsPower requirementsVoltage range .94-240 VAC (30 VA) .100-240 VDC (30 W)DC input specificationsNumber of input points 10 (sink/source)Number of commons .3 (isolated)Input voltage range .(X0–X3):10-26.4 VDC .(X4-X11):10-26.4 VDC or 21.6–26.4 VACInput impedance 2.8 Kq @ 12-24 VDCON current/voltage level 3 mA / 9 VDCOFF current/voltage level 0.5 mA / 2 VDCOFF to ON response .X0-X3: 50 µs .X4-X11: 2-8 msON to OFF response .X0-X3: 50 µs .X4-X11: 2-8 msFuses .NoneRelay output specificationsNumber of output points .8Number of commons .4 (isolated)Output circuitry RelayOutput voltage range 12-250 VAC .12-30 VDCMaximum voltage .265 VAC, 150 VDCMaximum current .7 A/point (see derating)Maximum inrush current .12 AMinimum load 10 mAMinimum OFF resistance .100 Mq @ 500 VDCOFF to ON response .15 msON to OFF response .5 msFuses .None (external recommended)Input point wiringEquivalent circuithigh-speed inputs (X0-X3)Auxiliary 24 VDC OutputVoltage range .21.6 - 26.4 VDCOutput .500 mA max., isolatedRipple .less than 200 mV p - pEquivalent circuitstandard inputs (X4-X11)Typical Relay Life (Operations)at Room TemperatureVoltage and Typeof LoadLoad Current50 mA5A7A24 VDC Resistive10M600K24 VDC Solenoid—150K75K110 VAC Resistive—600K300K110 VAC Solenoid—500K200K220 VAC Resistive—300K150K220 VAC Solenoid—250K100KDerating chart for DC inputs300KEquivalent output circuitDerating chart for relay outputswww.automationdirect.com/dl105DL105 PLCstDL1-10

For the latest prices, please check AutomationDirect.com.DL105 I/O SpecificationsF1-130DD-DOutput point wiring 239.00Wiring diagramand specificationsPower requirementsVoltage range .10-30 VDC .10 W max.DC input specificationsNumber of input points .10 (sink/source)Number of commons .3 (isolated)Input voltage range (X0–X3): 10-26.4 VDC .(X4-X11): 10-26.4 VDC or 21.6–26.4 VACInput impedance 2.8 Kq @ 12-24 VDCON current/voltage level 3 mA / 9 VDCOFF current/voltage level 0.5 mA / 2 VDCOFF to ON response .X0-X3: 50 µs .X4-X11: 2-8 msON to OFF response .X0-X3: 50 µs .X4-X11: 2-8 msFuses .NoneDC output specificationsNumber of output points .8 (sinking)Number of commons 3 (internally connected).Output circuitry MOSFETOutput voltage range .5-30 VDCPeak voltage .60 VDCON voltage drop .0.4 VDC @ 0.5 AMaximum current Y0-Y1: 0.5 A/point Y2-Y7: 1.0 A/pointMaximum leakage current .15 µA at 30 VDCMaximum inrush current Y0-Y1: 1.5 A for 10 ms Y2-Y7: 3 A for 10 msMinimum load .NoneOFF to ON response .Y0-Y1: 10 µs.Y2-Y7: 3.5 µs .ON to OFF response Y0-Y1: 70 µs .Y2-Y7: 110 µsFuses .None (external recommended)Derating chart for DC inputsNote: Same supply can be used to powerboth input and output circuits becauseall circuits are isolated from the internallogic.Input point wiringEquivalent circuithigh-speed inputs (X0-X3)Equivalent circuitstandard inputs (X4-X11)Derating chart for DC outputsEquivalent output circuitTo other circuits in bank V VOutputCommontDL1-11DL105 PLCs1-800-633-0405

For the latest prices, please check AutomationDirect.com.DL105 I/O SpecificationsF1-130DR-D 209.00Output point wiringWiring diagramand specificationsDC power supply specificationsVoltage range . 10-30 VDC .10 W max.DC input specificationsNumber of input points .10 (sink/source)Number of commons 3 (isolated)Input voltage range . X0–X3: 10-26.4 VDC . X4-X11: 10-26.4 VDC or 21.6–26.4 VACInput impedance 2.8 Kq @ 12-24 VDCON current/voltage level 3 mA / 9 VDCOFF current/voltage level 0.5 mA / 2 VDCOFF to ON response . X0-X3: 50 µs X4-X11: 2-8 msON to OFF response X0-X3: 50 µs X4-X11: 2-8 msFuses . NoneInput point wiringRelay output specificationsNumber of output points .8Number of commons 4 (isolated).Output circuitry RelayOutput voltage range 12-250 VAC .2-30 VDCMaximum voltage .265 VAC, 150 VDCMaximum current .7 A/point (See derating)Maximum inrush current .12 AMinimum load .10 mAMinimum OFF resistance .100 Mq @ 500 VDCOFF to ON response .15 msON to OFF response 5 msFuses .None (external recommended)Note: Same supply can be used topower both input and output circuitsbecause all circuits are isolated fromthe internal logic.Equivalent circuithigh-speed inputs (X0-X3)Equivalent circuitstandard inputs (X4-X11)Typical Relay Life (Operations)at Room TemperatureVoltage and Type of LoadLoad Current50 mA 5 A7A24 VDC Resistive10M600K24 VDC Solenoid—150K75K110 VAC Resistive—600K300K110 VAC Solenoid—500K200K220 VAC Resistive—300K150K220 VAC Solenoid—250K100KDerating chart for DC inputs300KEquivalent output circuitDerating chart for relay outputswww.automationdirect.com/dl105DL105 PLCstDL1-12

For the latest prices, please check AutomationDirect.com.Four-Point SimulatorF1-04SIM 20.00Wiring diagramand specificationsFor AC powered units, there are no extra wiring connections.Power is obtained directly from the 24 VDC auxiliary supply.Power input wiringOutput point wiringThe F1-04SIM is a simple 4-point simulator that can be used with DC inputversions of the DL105 micro PLCs. It usesinput points X0-X3 and is great for testingpurposes.Note: you cannot use this simulator with units thathave AC discrete input points.The simulator is a single circuit boardthat simply slides

Programmable Logic Controllers (PLC) In this interactive PDF you can: Use bookmarks to navigate by product category Use bookmarks to save, search, print or e-mail the. catalog section Click on part #s to link directly to our online store. for current pricing, specs, stocking informa