Airfield Cable & Accessory Catalogue

Transcription

Airfield Cable & Accessory CatalogueNORTH EUROPE1

Linking the futureAs the worldwide leader in the cable industry,Prysmian Group believes in the effective, efficientand sustainable supply of energy and informationas a primary driver in the development ofcommunities.With this in mind, we provide major globalorganisations in many industries with best-in-classcable solutions, based on state-of-the-arttechnology.Through two renowned commercial brands Prysmian and Draka - based in almost 50 countries,we‘re constantly close to our customers, enablingthem to further develop the world‘s energy andtelecoms infrastructures and achieve sustainableand profitable growth.2For our energy business, we design, produce,distribute and install cables and systems for thetransmission and distribution of power at low,medium, high and extra-high voltage.For telecoms, the Group is a leading manufacturerof all types of copper and fibre cables, systems andaccessories for voice, video and data transmission.Drawing on over 130 years‘ experience andcontinuously investing in R&D, we applyexcellence, understanding and integrity toeverything we do, meeting and exceeding theneeds of our customers across all continents while at the same time shaping the evolutionof our industry.

Linking global expertise to thewheels of industryOn every continent, in applications that rangefrom air and rail transport infrastructure to heavyduty industries such as mining, tunnel drilling anddefence, Prysmian’s specialist cable solutions sitat the heart of significant international projects;supporting the work of major customers, withhigh-performing, durable and safe technology.As the world leader in cabling, we draw on globalexpertise and local presence to work in closeproximity with our customers, delivering productsand service platforms, built on easy contact,customized solutions and effective supply chains,meeting their specialized requirements, to helpthem drive the wheels of industry and achievesustainable growth and profitability. As theworldwide leader in the cable industry, PrysmianGroup believes in the effective, efficient andsustainable supply of energy and information as aprimary driver in the development of communities.3

Airfield lighting cablesWith multiple aircraft takeoffs and landings everyminute, lighting systems play a vital part in ensuring the safety of pilots, crew, passengers and cargoalike. Prysmian’s cables and accessories ensure thecontinuous operation of these lighting systems,across airport runways, taxiways, buildings andtowers and other obstacles. Including connectorsand terminations for medium-voltage and transformer circuits, Prysmian Group airport cablesensure airport safety worldwide.Prysmian Group offers a comprehensive, cuttingedge and continually evolving airfield lightingcable product portfolio that caters for today’sever-increasing and diverse market demands.Anticipating changing trends and requirements,and working in constant proximity with ourcustomers, we’re positioned to provide constantprogress in keeping the wheels of industry turningaround the world.Ground power supply cablesPrysmian 400 Hz ground power supply cables arespecially designed for the power supply of aircrafts,computer systems and radar stations - andcomprise both static cables in buildings as well asflexible connections between aircrafts, passengerbridges, hangers and buildings.This is based on our long history and unparalleledknow-how and experience with flexible cablematerials for demanding handling and environmental applications, for niche industries rangingfrom mining and crane to wind turbines, rollingstock and even subsea cables.The 400 Hz gound power supply cables provide thebest design with the maximum number of optionsand provides great verstility for the aircraft oftoday and for the future aircraft requirements.All of our products are produced with dimensionand weight reduction in mind and we adapt to suitthe needs of each customer. Our excellence inquality and on-time delivery is recognized andappreciated by al lour customers, to whom wedelivery worldwide.We cater for a broad range of requirements, withcables types to reflet the applications in which theyare employed. For standard range cable types weprovide resistance to severe mechanical, electricaland chemical, temperature and radioactiveconstraints.4

Emergency stop systemsPrysmian Group emergency stop sytem calledPressLine is a unique system that offers continuous emergency stop protection around complexindustrial hazards. The system is used in many applications throughout the world. It has proven particularly successful for conveyor system in AirportBaggage Control. The actuating device is patentedpressure sensitive cable that can follow any routeup to 10 km. Activations is by pressing, beding orpulling the cable at any point along its length. ThePressLine control unit monitors the pressuresensitive cable and employs rigorously tested solidstate technology.The control unit continuously monitors the cableand confirms system functionality. If an activationstate is detected in the cable, the control unitinteracts with machinery controls to switch offplant or activate alarms.With origins streaching back over 100 years,Prysmian has developed an enviable reputation forproduct quality and innovative design. PrysmianCompoments manufacturers and supplies toaccredited Business Management System BS ENISO09001, BS EN ISO14001 and is certified forOHSAS18001.5

Airfield Cable & Accessory6

IndexCables for any applicationpage 8Explanation of symbolspage 11Airfield cable data sheetspage 12Transport and storage of cable drumspage 62Important physical characteristicspage 63Our responsibilitiespage 64Our references worldwidepage 667

Airfield Cable & AccessoryCables for any applicationCables forfield transformerCables foraircraft groundpowerCables fortemporary powerdistribution8Cables for airfieldprimary lightingcircuits

As the leading worldwide supplier, Prysmian Group offers an extensiverange of cabling solutions for different airport applications.Typical cable applications for airports include:Cables for airfieldsecondary lightingcircuitsPrimary Airfield Lighting Circuits LV screened cablesMV screened cables for dry or wet conditions MV FAA approved connectors and jointsSecondary Airfield Lighting Circuits LV flexible and flame retardant rubber cables LV FAA approved connectorsField Transformer FAA approved isolated 50 Hz and 60 Hz transformers Field transformers with or without earthing protectionTemporary Power Distribution LV flexible and durable rubber cablesAircraft Ground Power 400 Hz ground power cables for static or mobile application 1 6 core single sheath aviation cable or triplex design 400 Hz cable connecting assembliesEmergency Stop SystemsCables foremergencystop systems PRESSLINE - pressure sensitive cable system9

Airfield Cable & Accessory10

Explanation of symbols90 lowConductor temperatureMax. conductor temperature C in continuousoperation.Fire resistantFire resistant acc. to EN/IEC 60331-1 & 2.Flexible installationDue to IEC 60228 class 5 multi-standedconductor.UV resistantFilling and or outer sheath suitable foroutdoor application.Smoke densitySmoke propagation acc. to EN/IEC 61034.EMCFulfills EMC-directive with 100% densescreen with low coupling impedance.Halogen freeHalogen free acc. to EN/IEC 60754-1 andEN/IEC 50267-1.Impact resistantAgainst shocks.AcidityCorrosivity acc. to EN/IEC 60754-2.Pull resistantHigh tensile stress required to createcable failure.Fire retardantFlame propagation acc. to EN/IEC 60332-1.Bundled and vertical acc. to EN/IEC 60332-3.Weather proofScreened or armouredWith either copper, aluminum or steel wire,foil and tape.Watertight or proofAxial and radial water blocking viawater swellable tape or yarn.Oil resistantAcc. to DIN EN 60811-404MUD resistantResistance to chemicals in drilling mudacc. to NEK TS 606:201611

Index of data sheets1PRIMARY AIRFIELD LIGHTING CIRCUITS1.1Low voltage cablesIEC 60502-11.21.312PFSP 1 kV15IEC TS 62100EFSP 3 kV16IEC TS 62100LKCE 3 kV17IEC TS 62100PFSP 6 kV18IEC TS 62100PFSP EMC 5 kV19IEC TS 62100FLYCY 5 kV20DIN VDE 0271 & IEC 60502-2FLYCY 6 kV21IEC TS 62100FL2YCY 5 kV22FAA L-824FAA L-824 Type B 5 kV23FAA L-824FAA L-824 Type C 5 kV24MAKMAK CERTIFIED CABLE - 5 kV25Slip-on connector for unscreened cables - style 3 & 10INTEGRO FAA L-823 CONNECTOR KIT 5 kV27Slip-on connector for screened cables - style 3 & 10INTEGRO FAA L-823 CONNECTOR KIT 5 kV28Cast resin jointPRYSMIAN CAST RESIN JOINT 6 kV29Taped jointPRYSMIAN TAPED JOINT 6 kV30Medium voltage cablesConnectors & Joints2SECONDARY AIRFIELD LIGHTING CIRCUITS2.1Low voltage cables2.2PAGEPAGEEN 50525-2-21H07RN-F 450/750 V32EN 50525-2-21TARMO H07BN4-F 450/750 V33EN 50525-2-21ATON 450/750 V34FAA L-824FL2X2Y 0,6/1 kV35MAK certifiedMAK CERTIFIED 450/750 V36Factory moulded connector - style 6FAA L-823 CONNECTOR 1 kV37Factory moulded connector - style 1, 7 & 8FAA L-823 CONNECTOR 1 kV38Slip-on connector - style 5 & 12INTEGRO FAA L-823 CONNECTOR KIT 600 V39Slip-on connector - style 4 & 11INTEGRO FAA L-823 CONNECTOR KIT 600 V40Connectors

3FIELD TRANSFORMERS3.1IsolatedFAA L-830 seriesINTEGRO ISOLATED TRANSFORMER 60 Hz42FAA L-831 seriesINTEGRO ISOLATED TRANSFORMER 50 Hz43Earthed seriesINTEGRO ISOLATED TRANSFORMER 50 Hz & 60 Hz444TEMPORARY POWER DISTRIBUTION4.1Low voltage cablesPAGEPUR sheatedQWPK 450/750 V47EPR sheatedH07RN-F 450/750 V485400 Hz AIRCRAFT GROUND POWER5.1Supply cables5.2PAGEPAGEMobile applicationRU CL5 MUD 0,6/1 kV51Static application400 Hz PRYFLEX AV8R 1 kV52Mobile application400 Hz PRYFLEX AV8R TRIPLEX 1 kV53Mobile application400 Hz PRYFLEX AV8R 1 kV54Mobile application400 Hz SINGLE SHEATED AVIATION CABLE 1 kV56400 Hz GROUND POWER SUPPLY CABLE ASSEMBLIES57Cable assemblyMoulded cable assembly6EMERGENCY STOP SYSTEMS6.1System solutionPressure sensitive cable systemPAGEPRESSLINE59Many more cable types and tailor-made cables are available for your individual application.13

14

PrimaryairfieldlightingLOW VOLTAGE1.PFSP 1 kVALUMINIUM SCREEN & PVC SHEATHApplicationSpecial cable for airfield lightning applications.Suitable for direct installation in the groundwithout extra protection outdoors. Fulfills therequirements of main aviation organizations.Technical dataRated voltage: 0,6/1 kVTemperature rangeMax conductor temperature: Max. conductor temperature: 70 CStandard & ApprovalStandard: Cenelec EC HD 603-3J IEC 60502-1Approval: NEMKOConstructionConductor: Round Solid copper Acc. to IEC 60228 class 1.Insulation: PVC BlackInner sheath: Extruded compound BlackScreen: Aluminium tape Concentrically appliedGrounding: Copper wireOuter sheath: PVC Black70 Material propertyFlame retardant: Acc. to EN 60332-1Content is subject to changes acc. to current product development and or any changes to terdiametermmCableweightkg/kmPrysmianEANno.1 x 6/6ER11190702152412023715

1. PrimaryairfieldlightingMEDIUM VOLTAGEEFSP 3 kVALUMINIUM SCREEN & PVC SHEATHApplicationSpecial cable for airfield lightning applications.Suitable for direct installation in the groundwithout extra protection outdoors. Fulfills therequirements of main aviation organizations.Technical dataRated voltage: 1,7/3 kVTemperature rangeMax conductor temperature: 70 CStandard IEC 60502-170 ConstructionConductor: Round Stranded copper wires Acc. to IEC 60228 class 2.Insulation: PolyetylenInner sheath: Extruded compoundScreen: Aluminium tape Concentrically appliedGrounding wire: CopperOuter sheath: PVC BlackMaterial propertyFlame retardant: Acc. to EN 60332-1Content is subject to changes acc. to current product development and or any changes to OuterdiametermmCableweightkg/kmPrysmianEANno.1 x 6/6ER142607021525051004

PrimaryairfieldlightingMEDIUM VOLTAGE1.LKCE 3 kVCOPPER SCREENED & PE SHEATHApplicationSpecial cable for airfield lightning applications.Suitable for direct installation in the groundwithout extra protection outdoors. Fulfills therequirements of main aviation organizations.Technical dataRated voltage: 1,8/3 kVTest voltage: 10,5 kV AC, 5 min.Temperature rangeMax conductor temperature: 70 CMin. installation temperature: -15 CStandard IEC TS 62100ConstructionConductor: Round and annealed Stranded copper wires Acc. to IEC 60228 class 2.Insulation: Extruded polyethylene (PE) Thickness nom. 3,0 mmScreen: Copper wires Concentrically applied Area nom. 6 mm2Outer sheath: Extruded polyethylene (PE) Type ST 3 Thickness nom. 1,4 mm Weather resistant Black70 Material property Halogen free: IEC 60754-1 Acidity: IEC 60754-2Content is subject to changes acc. to current product development and or any changes to terdiametermmCableweightkg/km1 x 6/6FR14220PrysmianEANno.17

1. PrimaryairfieldlightingMEDIUM VOLTAGEPFSP 6 kVCOPPER SCREEN & PVC SHEATHApplicationSpecial cable for airfield lightning applications.Suitable for direct installation in the groundwithout extra protection outdoors. Cablemeets Norwegian climate requirements.Technical dataRated voltage: 3,6/6 kVTemperature rangeMax conductor temperature: 70 CStandard IEC TS 6210070 ConstructionConductor: Round Stranded copper wires Acc. to IEC 60228 class 2.Insulation: PVC Thickness 4 mm WhiteInner sheath: Extruded compoundScreen: Copper wires Concentrically applied Counter helix of copper tapeOuter sheath: PVC BlackMaterial propertyFlame retardant: Acc. to EN 60332-1Content is subject to changes acc. to current product development and or any changes to OuterdiametermmCableweightkg/kmPrysmianEANno.1 x 6/6FR163507021524119156

PrimaryairfieldlightingMEDIUM VOLTAGE1.PFSP EMC 5 kVCOPPER SCREEN & PVC SHEATHApplicationConstructionSpecial cable for airfield lightning applications.Suitable for direct installation in the groundwithout extra protection outdoors. Copperscreen provides 100% coverage with lowcoupling impedance that fulfills the EMCdirective when properly installed. Fulfills therequirements of main aviationConductor:Technical dataRated voltage: 5 kVBending radius: Installation: 20 x D Fixed: 15 x DPulling force: Stranded copper wires Acc. to IEC 60228 class 2.Insulation: PVC compound, 4 mm WhiteScreen: Copper foil with overlap - 0,05 mm Counter helix of copper wires 6 mm2 thick screenOuter sheath:Max. 50 N/mm2Temperature rangeMax conductor temperature: 70 CMin. insallation temperature: -40 C PVC Black70 Material propertyFlame retardant: Acc. to IEC 60332-1Standard & ApprovalStandard: IEC TS 62100Approval: HAR NEMKOContent is subject to changes acc. to current product development and or any changes to 1 x 6/6416335702152505105919

1. PrimaryairfieldlightingMEDIUM VOLTAGEFLYCY 5 kVCOPPER SCREEN & PVC SHEATHApplicationConstructionSpecial cable for airfield lightning applications.Suitable for fixed installation outdoors, inpipes or directly in the ground without extraprotection. Fulfills the requirements of mainaviation organizations.Conductor: Stranded and annealed Acc. to IEC 60228 class 2.Insulation: PVC compound, 4 mmScreen: Annealed copper wires 2,5 or 6,0 mm2 Concentrically appliedTechnical dataRated voltage: 5 kVBending radius: During installation: min. 15 x D Fixed: min. 10 x DPulling force: Max. 50 N/mm270 Temperature range Max. conductor temperature: 70 C Short circuit temperature: 160 C Lowest temp. at installation: -10 COuter sheath: PVC compound - 1,4 mm Black or redMaterial propertyFlame retardant: Acc. to IEC 60332-1Standard IEC TS 62100Content is subject to changes acc. to current product development and or any changes to OuterdiametermmCableweightkg/kmStandarddeliverym1 x 6/2,5FR15,43101000 - K91 x 6/6,0FR16,03351000 - K9PrysmianEANno.

PrimaryairfieldlightingMEDIUM VOLTAGE1.FLYCY 6 kVCOPPER SCREEN & PVC SHEATHApplicationConstructionSpecial cable for airfield lightning applications. The cable has excellent electrical andmechanical properties. The low weight andflexibility of the cable make it easy to lay andinstall. Suitable for fixed installation outdoors,in pipes or directly in the ground without extraprotection.Conductor: Stranded round copper wires Acc. to IEC 60228 class 2. RM Cross-section 6 mm2 Diameter nominal 2,7 mmInsulation: PVC compound Thickness nominal 3 mm Diameter over insulation 8,7 mm WhiteScreen: Copper wires Cross-section 2,5 mm2 Concentrically applied Counter helix of copper tape , fixedTechnical dataRated voltage: 3/6 kVBending radius: Minimum 10 x DPulling force: Max. 50 N/mm2Temperature range Max. conductor temperature: 70 C Short circuit temperature: 160 C Lowest temp. at installation: -10 COuter sheath: PVC compound - 1,4 mm Thickness nominal 1,8 mm BlackStandard DIN VDE 0271 IEC 60502-2Material propertyFlame retardant: 70 Acc. to IEC 60332-1Content is subject to changes acc. to current product development and or any changes to terdiameternom. mmCableweightkg/kmDC resistance at Cmax. Ω/km1 x 6/2,5RM13,12573,08PrysmianEANno.21

1. PrimaryairfieldlightingMEDIUM VOLTAGEFL2YCY 5 kVCOPPER SCREEN & PVC SHEATHApplicationConstructionSpecial cable for airfield lightning applications.Suitable for fixed installation outdoors, inpipes or directly in the ground without extraprotection. Fulfills the requirements of mainaviation organizations.Conductor: Stranded and annealed copper Acc. to IEC 60228 class 2.Insulation: Polyethylen - 3,4 mmScreen: Annealed copper wires Concentrically applied Counter helix of copper wiresTechnical dataRated voltage: 5 kVBending radius: During installation: min. 15 x D Fixed: min. 10 x DPulling force: Max. 50 N/mm270 Temperature range Max. conductor temperature: 70 C Short circuit temperature: 160 C Lowest temp. at installation: -10 CSeperator: Plastic tapeOuter sheath: PVC compound - 1,4 mm Lead free Black or redMaterial propertyFlame retardant: Acc. to IEC 60332-1Standard IEC TS 62100Content is subject to changes acc. to current product development and or any changes to OuterdiametermmCableweightkg/kmStandarddeliverym1 x 6/2,5FR142301000 - K10PrysmianEANno.

PrimaryairfieldlightingMEDIUM VOLTAGE1.FAA L-824 TYPE B - 5 kVFLEXIBLE EPR INSULATED CABLEApplicationConstructionFlexible single conductor 5000 volt powercables suitable for airport lighting circuits perFAA L-824 Type B. Installation in conduit,duct, aerial and direct burial applications.Rated for use at 90 C in dry conditions. Thesheat also offers additional protection fromdeicing fluids.Conductor: Stranded copper wires Acc. to IEC 60228 class 5. AWG type class C - softly drawn acc.to ASTM B3 & B8Insulation: EPR rubber compound Acc. to ICEA S-96-659 / NEMA WC71 Black or whiteOuter sheath CPE version: CPE - chorinated polyethylene compound Acc. to ICEA S-96-659 / NEMA WC71 Thickness 2,29 mm Black or whiteOuter sheath NEO version: NEO - neopren Thickness 0,76 mm BlackOuter sheath PVC version: CPE - chorinated polyethylene compound Acc. to ICEA S-96-659 / NEMA WC71 BlackTechnical data Rated voltage: 5 kV Tensile strength: max 5 daN Bending radius: fixed 10 x D Bending radius: during installation 20 x DTemperature range Max. conductor temperature: 90 C Short circuit temperature: 200 C Lowest temp. at installation: -25 CRating & Approval FAA L-824, AC N 150 150/5345 Type B(AWG type listed in AC N 150/5345-53Appendix 3.)90 Material propertyFlame retardant: (NEO version) Acc. to IEC 60332-1Content is subject to changes acc. to current product development and or any changes to onthicknessnom. mmOuter sheaththicknessnom. mmOuterdiamatermmCableweightkg/km1 x6 mm2Neoprene2,30,769,71408 AWGPVC2,30,7610,71806 AWGPVC2,30,7611,72384 AWGPVC2,30,7612,83268 AWGCPE2,30,7610,71746 AWGCPE2,30,7611,72344 AWGCPE2,30,7612,8322PrysmianEANno.23

1. PrimaryairfieldlightingMEDIUM VOLTAGEFAA L-824 TYPE C - 5 kVXLPE INSULATED CABLEApplicationConstructionSingle conductor 5000 volt screened andnon-screened power cables suitable for underground installation for use as airport lightingcircuits per FAA L-824 Type c.Conductor: Stranded copper Acc. to IEC 60228 class 2. AWG type - soft drawn bare copper acc.to ASTM B3 and B8Conductor screen: Extruded semi-conductive compoundInsulation: Cross-linked polyethylene (XLPE) Thickness 2,29 mm Off-whiteWrapping: Semi-conductive tapeScreen: Braid of tinned copper wires (CBS) Copper tape screen (CTS) Brass tape screen (BTS) Copper wires (CWS)Outer sheath:Suitable for use in conduit, duct, aerial anddirect burial installations up to 5000 voltsin 90 C wet or dry in conduit. Copper screenprovides protection against EMI.Technical data Rated voltage: 5 kV Tensile strength: max 5 daN Bending radius: fixed 10 x D Bending radius: during installation 20 x D90 Temperature range Max. conductor temperature: 90 C Short circuit temperature: 250 C Lowest temp. at installation: -25 CStandard FAA L-824, AC N 150/5345 Type C AWG type listed in AC N 150/5345-53Appendix 3) Polyethylene (PE)Cross-linked polyethylene (XLPE)Polyvinyl chloride (PVC)Thickness 1,14BlackContent is subject to changes acc. to current product development and or any changes to ialInsulationthicknessnom. mmOuterdiamatermmCableweightkg/km1 x6 mm2PECopper tape2,311,21601 x6 mm2XLPECopper tape2,311,21601 x6 mmPVCCopper tape2,412,62101 x6 mm2PEBrass tape2,412,61851 x6 mm2PVCBrass tape2,412,62101 x6 mm22PECopper wires2,413,02001 x6 mm2PVCCopper wires2,413,02301 x6 mmPECopper braid2,413,02101 x6 mm2PVCCopper braid2,413,02408 AWG--2,89,531376 AWG--2,810,41924 AWG--2,811,72762PrysmianEANno.

PrimaryairfieldlightingMEDIUM VOLTAGE1.MAK CERTIFIED CABLE - 5 kVFOR RUSSIAN TERRITORYApplicationConstructionSingle conductor 5000 volt power cablessuitable for underground installation for useas airport lighting circuits in military airports.Cables are suitable for use in wet or dry environments in conduit, duct, aerial and directburial installations. Installation in pipes is recommended to protect against rodents. Copperscreen provides protection against EMI.Conductor: Annealed copper wires Compacted Stranded acc. to IEC 60228 class 2.Conductor screen: Extruded semi-conductive compoundTechnical data Rated voltage: 5 kV Tensile strength: max 36 daN Bending radius final: 160 mm Bending radius installation: 320 mmTemperature range Max. conductor temperature: 90 C Short circuit temperature: 250 C Lowest temp. in operations: -60 CInsulation: XLPE cross-linked compound 2,29 mm Natural colourWrapping: Semi-conductive TapeScreen version CTS : Annealed copper foil 0,0635 mm Overlapping90 Screen version CWS : Tinned copper wire 0,25 mm BraidedStandard Extended FAA L-824 AC N 150/5345-7DType C MAKOuter sheath: PE, nom. thickness 1,14 mmBlacklowMaterial property Halogen free: IEC 60754-1 Smoke density: EN 60134 Acidity: IEC 60754-2Content is subject to changes acc. to current product development and or any changes to creenmaterialInsulationthicknessnom. mmOutercable diamaterapprox. mmCableweightapprox. kg/km1 x6PECopper tape2,311,11601 x6PECopper wire2,312,0200PrysmianEANno.25

26

PrimaryairfieldlightingSLIP-ON SEPARABLE CONNECTOR1.INTEGRO CONNECTOR KIT - 5 kVFAA L-823, STYLE 3 & 10 FOR UNSCREENED CABLESApplicationIntegro Primary Connector Kit is used toinstall isolation transformers into seriescircuits, and to make serviceable spliceconnections or test points in L-824 AirportLighting Cable on primary power circuits.Integro Primary Connector Kit is molded inthermoplastic rubber for superior dielectricstrength, and to ensure watertight connections in the field. Each molded kit housing isfilled with insulating silicone to fill voids.Extended Strain and bend relief preventsthe back end of connector from opening andallowing water to enter.Integrally molded O-rings (3 of them) sweepdebris from the cable jacket and grab holdto provide added sealing thereby completelyeliminating water entry to the connection.Technical data Rated voltage: 5 kV Continious voltage rating: max. 25 AStandard & Directive Watertight FAA L-823 - style 3 & 10 Certefid by Intertek Testing Labs FAA Advisory Circular 150/5345-26ConstructionDesign: Pre-fabricated MouldedConnector housing: Thermoplastic rubber WatertightInsulation: Silicone Fill voids inside housingKit components - style 3: Male pin and housing Paper wipe for cleaning lnstructionsKit components - style 10: Female receptacle and housing Paper wipe for cleaning lnstructionsCable rangeCable diameter: From 6 to 8 AWGCable type: Single-core cables Without metallic screen XLPE, PVC or PE outer sheathContent is subject to changes acc. to current product development and or any changes to standards.Integro Connector KitL-823 style 3 & 10part no.CabletypeOuter sheathdiametermin. inchesOuter sheathdiametermax.inches11174-01 (Standard kit)8 AWG0,320,4311174-04 (Standard kit)6 AWG0,320,4311174-05 (Standard kit)8 AWG0,410,58511174-06 (Standard kit)6 AWG0,410,58511805-01 (Complete kit)8 AWG0,300,33511805-05 (Complete kit)8 AWG0,380,33511805-04 (Complete kit)6 AWG0,300,33511805-02 (Complete kit)6 AWG0,380,33527

1. PrimaryairfieldlightingSLIP-ON SEPARABLE CONNECTORINTEGRO CONNECTOR KIT - 5 kVFAA L-823, STYLE 3 & 10 FOR SCREENED CABLESApplicationIntegro Primary Connector Kit is used toinstall isolation transformers into seriescircuits, and to make serviceable spliceconnections or test points in L-824 AirportLighting Cable on primary power circuits.The connector housing is molded in thermoplastic rubber and filled with silicone for superior dielectric strength and watertightness.Technical data Rated voltage: 5 kV Continious voltage rating: max. 25 AStandard & Directive Watertight FAA L-823 - style 3 & 10 Certefid by Intertek Testing Labs FAA Advisory Circular 150/5345-26ConstructionDesign: Pre-fabricated Moulded housingConnector housing: Thermoplastic rubber Roll-over flap on front of connector WatertightInsulation: Silicone Fill voids inside housingGrounding wire (2 versions): Insulated grounding wire Copper grounding wireKit components - style 3: Male pin and housing Paper wipe for cleaning InstructionsKit components - style 10: Female receptacle and housing Grounded bot paper wipe InstructionsCable rangeCable diameter: From 6 to 8 AWGCable type: Single-core cables With metallic screen XLPE, PVC or PE outer sheathContent is subject to changes acc. to current product development and or any changes to standards.28Integro Connector KitL-823 style 3 & 10 part no.With insulated grounding wireIntegro Connector KitL-823 style 3 & 10 part no.With copper grounding wireCabletypeOuter sheathdiametermin. inchesOuter sheathdiametermax.inches11869-0111847-018 AWG0,375 - 0,450,3 - 0,411869-0211847-028 AWG0,450 - 0,5250,3 - 0,411869-0311847-038 AWG0,525 - 0,60,38 - 0,511869-0411847-048 AWG0,6 - 0,6750,38 - 0,511869-0511847-056 AWG0,6 - 0,6750,38 - 0,5

PrimaryairfieldlightingCAST RESIN JOINT1.CAST RESIN JOINT - 6 kVWATERTIGHT & TOOL FREEApplicationPre-fabricated and watertight joint for airfieldlighting circuits. For on-site assembly andpouring resin for connecting to the primary ofthe isolating transformer.Suitable for single core cables with coppertape or wire screen. Applicable for indoorand outdoor installation either vertical orhorizontal positioned in concrete manhole ordirectly buried in the ground. Connector canbe energized immediately after plug-in andpolymersation of resin. Supplied as a kit withall necessary components.Technical dataVoltage: Rated voltage: 6 kV Continious voltage rating: max. 25 ATemperature range Max. operations temperature: 65 C Lowest operations temperature: -55 C Installation: From 5 C to 40 C Storage from 5 C to 40 CStandard & Directive Watertight acc. to AD7 ISO 9001 version 2 008 - EN 29 001 REACH conformity Product code: CFRAP51142 CTJMa-1C-J3ConstructionDesign: Pre-fabricated Tool free installation Copper ferruleCasing: Double layer Transparent thermoplastic material Snapped or fastned by slidersInsulation: EPR tape and synthetic resin (epoxy) Wrapped Polymerisation of resin at 5 C to 40 CSealing: Self-amalgamating tape or puttyKit components: Supplied as a kit For a single core joint Copper ferrule Epoxy resin All components required for installationRangeCable diameter: Up to 1 x 6 mm2 Max. outer diameter 22 mmCable type: Single-core copper cables XLPE insulation Copper tape screen XLPE, PVC or EPDM outer sheath65 Content is subject to changes acc. to current product development and or any changes to standards.Connector mShippingvolumeapprox. m3CFRAP 51142 CTJMa-1C-J31,7325520,00529

1. PrimaryairfieldlightingTAPED JOINTTAPED JOINT - 6 kVHEATSHRINKABLE OUTER PROTECTIONApplicationPre-fabricated and watertight taped joint forairfield lighting circuit connection to theprimary of the isolating transformer.Suitable for single core cables with coppertape screen. Applicable for indoor and outdoorinstallation either in a vertical or horizontalpositioned or in a concrete manhole. Jointcan be energized immediately after plug-in.Supplied as a kit with all necessarycomponents.Technical dataVoltage: Rated voltage: 6 kV Continious voltage rating: max. 25 ACable diameter: Up to 1 x 6 mm2 Max. outer diameter 22 mmCable type: Single-core copper cables XLPE insulation Copper tape

Airfield lighting cables Ground power supply cables Prysmian 400 Hz ground power supply cables are specially designed for the power supply of aircrafts, computer systems and radar stations - and comprise both static cables in buildings as well as flexible connections bet