OWNER'S MANUAL 1 For All Programmable Digital Thermostat

Transcription

OWNER'S MANUALP/N P474-10501 For AllProgrammableDigital ThermostatTOTALINEI2:0072Mo74COOLAUTO70HEATDual Setpoint5 2 Day Programmable4 Time periodsVery Easy to ProgramLarge, Easy To Read DisplayThermoglow BacklightNo Batteries RequiredAuto ChangeoverNo Batteries RequiredLocking KeypadMeets California Title 24 ResidentialUse with most Air Conditioning & Heating Systems including: 1 or 2 StageElectric Cooling & Gas Heating, Heat Pump, Electric or Hydronic Heat.TOTALINEReplacement Components DivisionCarrier Corporation 04/01

Table Of ContentsFRONT PANELDISPLAYQUICK START Set the clock and goBASIC OPERATIONPROGRAMMING 4 Time PeriodsADVANCED SETUPABOUT ADVANCED OPERATIONWARRANTY23568121621CAUTIONFollow Installation Instructions before proceeding.SET THERMOSTAT TO MODE “OFF” PRIOR TOCHANGING SETTINGS IN SETUP OR RESTORINGFACTORY DEFAULTS.Replacement Components DivisionCarrier Corporation 04/01P/N P474-1050Page 1

Front PanelTOTALINEI2:0072Mo174COOLAUTO70HEAT32451Liquid Crystal Display2Up/Down Buttons3Mode Button4Fan Button5Heat or Cool Indicatorwith ThermoglowHeat Red, Cool GreenPage 2

Display52I2:00AmPmNightSetup68888 88SuMoTuWeThFrSaCOOL41AUTO3Locked8ONOFFProgram OnHEAT57Morning DayEveningFan On141Mode IndicatorsSelects the operation mode of the equipment.HEAT - indicates the heat mode.COOL - indicates the air conditioning mode.AUTO - indicates the system will automaticallychangeover between heat and cool modesas the temperature varies.OFF - indicates the entire system is turned off.PROGRAM ON - indicates the stored programis enabled to run. Page 6.2Clock with Day of the WeekIndicates the current time and day. This clock isalso used to program the timer periods. Page 5.3Room Temperature DisplayIndicates the current room temperature.4Desired Set TemperatureIndicates desired room temperature(s). Page 7.Page 3

Display5Morning, Day, Evening & Night IndicationIndicates the program time period.Page 8-11.6Setup IndicationIndicates the thermostat is in the programmingmode. Page 12.7Fan Operation IndicationFan On - indicates constant, continuous fanoperation.When Fan On is not lit - indicates the fan willonly operate when necessary to heat orto cool. Page 7.8Locked IndicationLocked appears after the right combination ofbuttons are pressed, rendering the buttonsinoperative. Page 18.Page 4

Quick Start Set the Clock and GoPress the Mode button.While holding the Mode,press the Fan buttonfor 2 seconds to enter Setupscreens.MODEFANI2:00During Setup & Programming:Pressing the Mode buttonselects different flashing items.(Represented in dark black)Pressing the Up and Downbuttons will modify the flashingselection.IPressSuMoTuWeThFrSa2To adjust theclock or Day useMODEbuttons.Press both Mode andFan buttons asabove to return tonormal operation.MODEFANThe thermostat is preprogrammed from thefactory to operate 1 or 2 Stage equipment* withoutthe need for further programming. To optimize theinstallation of this thermostat follow the instructionsin the Advanced Setup section.* The thermostat is not preprogrammed from thefactory to operate electric heat or heat pump systems.To control these systems, follow the steps in theAdvanced Setup section, pages 12 & 13.Page 5

Basic OperationSelect ModeI2:00The HEAT setting indicates thetemperature the room has toreach before the furnace willturn on to heat the room.70 69The COOL setting indicates thetemperature the room has toreach before the air conditionerwill turn on to cool the room.70SuI2:00SuMODE72MODEI2:007270 69SuAUTO will automatically selectheat or cool based on roomtemperature demand.I2:0073MODE70 70SuProgram On will activate thestored timer operation.(Morning, Day, Evening, Night)DayI2:0070MODESuOFF indicates both heatingand air conditioningsystems are turned off.Page 6OFF

Basic OperationSelect Desired TemperatureI2:0070PmMo72In any mode, adjust thedesired Set TemperaturewithCOOLAUTO69HEATbuttons.Pressing the up/down buttons in Auto mode will adjust both the heat and coolset temperatures simultaneously.Pressing the up/down buttons in Heat or Cool modes will adjust only theheat or cool set temperature.FanOperationI2:0070MoFan OnPmPressFAN72COOLFan On indicates constant fan operation.This feature is active even if the thermostatis set to Off.AUTO69HEATPage 7

ProgrammingMODE4 Time periodsPress the Mode button. While holding the Mode,press the Up button for 2 seconds to entertime period programming.MoTuWeThFrSelect the Day of the Week.MoTuWeThFr or SaSu.(Weekday or Weekend schedule)PressMODE7:30AmMoTuWeThFrAdjust the start time forMorning.PressMorningMODE7:30AmMoTuWeThFrAdjust the cooling setpointfor Morning.74COOL(35 - 99 )PressMorningMODE7:30AmMoTuWeThFrAdjust the heating setpointfor Morning.(35 - 99 )74COOL72HEATMorningContinuedPage 8PressMODE

Programming4 Time PeriodsI0:30AmMoTuWeThFrAdjust the start time forDay.PressDayMODEI0:30AmMoTuWeThFrAdjust the cooling setpointfor Day.75COOL(35 - 99)PressDayMODEI0:30AmMoTuWeThFrAdjust the heating setpointfor Day.75COOL(35 - 99)73HEATDay5:30Adjust the start time MoTuWeThFrAdjust the cooling setpointfor Evening.75MODECOOL(35 - 99)PressEveningMODEContinuedPage 9

Programming4 Time Periods5:3075PmMoTuWeThFrCOOLAdjust the heating setpointfor Evening.(35 - 99)73HEATEveningI I:30PressMODENightPmMoTuWeThFrAdjust the start timefor Night.PressMODEI I:30NightPmMoTuWeThFr78COOLAdjust the cooling setpointfor Night.(35 - 99)PressI I:30NightPmMoTuWeThFrAdjust the heating setpointfor Night.(35 - 99)78MODECOOL70HEATPressMODEContinuedPage 10

Programming4 Time PeriodsSuSaSelect the Day of the Week.MoTuWeThFr or SaSu.(Weekday or Weekend schedule)PressMODEContinue Time Period Programming Morning throughNight as done in previous steps starting on page 8for the Weekend schedule.To Exit ProgrammingMODEPress the Mode button. While holding the Mode,press the Up button for 2 seconds to exittime period programming.Page 11

Advanced SetupPress the Mode button.While holding the Mode,press the Fan buttonfor 5 seconds to enter Setupscreens.MODEFANI2:00NOTE: Each step # is located atthe top right corner of thedisplay for easy reference.AmSetupIAdjust the time of dayclock.PressTip: To change hours quickly, press andhold the Fan button in and pressthe up or down buttons.MODEMoSetup2Select the day of theweek.PressMODEOnHpSetupSelect residential Heat Pump,ON or OFF.Off3OFFPressMODEContinuedPage 12

Advanced SetupBSelect the reversingvalve polarity forHeat Pump, O or B.(Step 4 only appears ifheat pump is on in step 3)OSelect Electric Heat Onor Off. (Step 5 onlyappears if heat pump isoff in step 3)Setup4Setup50Eh2281fAdjust the minimumdifference betweencooling & heatingsetpoints.(0 - 6 )OFFPressSetup6Setup788Adjust the deadbandfrom 1 - 6 tinuedPage 13

Advanced SetupSelect the cycles perhour limit.d cycles per hourlimit defeated.d1 d defeat 5 min.Compressor lockout.(d, d1, 2 - 6)6Setup8CyPressMODEOnLISetupSelect the display backlight always On, or Offafter 8 seconds.Off9ONPressMODECFFSetupSelect thermostatoperation in degreesFahrenheit or Centigrade.I0MODEFANPress the Mode button.While holding the Mode, press the Fanbutton for 2 seconds to leave the Setupscreens. If no buttons are pressed, thedisplay will leave the setup screens after30 seconds.Page 14

Advanced SetupAdvanced Setup TableStep #12345678910DescriptionTime of day clock setDay of the weekHeat PumpReversing Valve polarityElectric HeatDeadband or Temperature swingForced minimum difference heat/coolCycles per hourThermoglow backlightFahrenheit or CentigradePage 15RangeFactory Default24 hourSun - SatOff / OnO/BOff / On1-60-6d, d1, 2 - 6Off / OnF/C12:00 AmMondayOffOOff226OnF

About Advanced Features & Operation2 STAGE OPERATION - The 2nd Stage of heat or cool isturned on when (1) the 1st Stage has been on for aminimum of two minutes, and (2) the temperature spreadfrom the setpoint is equal to or greater than: the setpointplus the deadband, plus 2 degrees.CoolingHeating2 degrees2nd Stageturn on1st Stageturn onDeadBandHeatSetpointDeadBandCoolSetpoint2 degrees1st Stageturn on2nd Stageturn onMINIMUM HEAT/COOL SETPOINT DIFFERENCE - The Heatand Cool setpoints will not be allowed to come any closerto each other than the value set in Advanced Setup step# 7, on page 13. This minimum difference is enforcedduring Auto changeover and Program On operation.Page 16

About Advanced Features & OperationEMERGENCY HEAT - Is a feature available to Heat Pumpinstallations. To turn on Emergency Heat press in theFan button. While holding the Fan button pressthe Up button for 2 seconds. The Cool setpoint displaywill read ‘EH’.I2:0073SuPress forEmergency Heateh74FanDuring Emergency Heat the thermostat will turnon the fan and the 2nd stage of heat, when there is ademand for heat, locking out the 1st stage compressor.Exiting Emergency Heat is the same as entering. DuringEmergency Heat only OFF and HEAT are available.ELECTRIC HEAT - Selecting Electric Heat on, page 13,step 5, will cause the thermostat to turn on the fanimmediately any time there is a heat demand. Since allgas furnaces control the fan, this feature should be offunless the heater is only electric.Page 17

About Advanced Features & OperationKEYPAD LOCK - To prevent unauthorized use of the thermostat,the front panel buttons may be disabled. To disable, or‘lock’ the keypad, press and hold in the Mode button.While holding the Mode button in, press the Up and Downbuttons in together. The Locked icon will appear on thedisplay.AmI2:0070SuPress all 3 forKeypad LockoutMODENight85COOLLockedProgramOnHEAT55To unlock the buttons, again press and hold the Modebutton. While holding the Mode button in, press the Upand Down buttons in together. The Locked icon willdisappear from the display.Page 18

About Advanced Features & OperationDUAL SETPOINT BEHAVIOR - The adjustable setpoint rangeis: 35 - 99 degrees in Fahrenheit and 7 - 35 degrees inCentigrade. When in the modes Heat or Cool, thisadjustable range is unhampered.When adjusting any Auto mode, including programmingOccupied and Unoccupied periods, the 1050 will notallow the Heat setpoint to get closer to the Cool setpointthan the value programmed as the minimum difference instep 7, page 13.When entering the Auto mode from Cool, the Heat andCool setpoints will remain spread apart by the amountthat they were adjusted, prior to entering Auto.For example: If the Cool setpoint was set to 80 whilein the Cool mode and the Heat setpoint was adjusted to70 while in the Heat mode, upon entering the Auto modethe Heat and Cool setpoints would be 80 and 70. Bothsetpoints would then move up and down together, (in thisexample spread by 10 degrees), by pressing the up ordown buttons.To move the Heat and Cool setpoints closer together,enter the Cool or Heat mode by pressing the Mode button,then adjust the setpoint(s) closer together. Heat is limitedto how close it can come to Cool by step 7, page 13.Page 19

About Advanced Features & OperationAbout Advanced Features & OperationFACTORY DEFAULTS - If, for any reason it is desirable toreturn all stored settings back to the factory defaultsettings, press the Mode button. While holding the Modebutton in, press the Down button for 2 sec. All icons willappear. Press and hold in the Fan button until Fdappears. This resets all factory settings. To calibrateroom temperature, press the Mode button once more.At this point use the Up and Down buttons to calibrateroom temperature, if needed. Press the Mode button toreturn to normal operation. NOTE CAUTION ON PAGE 1.Page 20

WarrantyOne-Year Warranty - This Product is warranted to be free from defects in material andworkmanship. If it appears within one year from the date of original installation, whether or notactual use begins on that date, that the product does not meet this warranty, a new orremanufactured part, at the manufacturer’s sole option, to replace any defective part will beprovided without charge for the part itself; PROVIDED the defective part is returned to thedistributor through a qualified servicing dealer.THIS WARRANTY DOES NOT INCLUDE LABOR OR OTHER COSTS incurred for diagnosing,repairing, removing, installing, shipping, servicing or handling of either defective parts orreplacement parts. Such costs may be covered by a separate warranty provided by the installer.THIS WARRANTY APPLIES ONLY TO PRODUCTS IN THEIR ORIGINAL INSTALLATIONLOCATION AND BECOMES VOID UPON REINSTALLATION.LIMITATIONS OF WARRANTIES – ALL IMPLIED WARRANTIES (INCLUDING IMPLIEDWARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY) AREHEREBY LIMITED IN DURATION TOT THE PERIOD FOR WHICH THE LIMITED WARRANTYIS GIVEN. SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIEDWARRANTY LASTS, SO THE ABOVE MAY NOT APPLY TO YOU. THE EXPRESSEDWARRANTIES MADE IN THIS WARRANTY ARE EXCLUSIVE AND MANY NOT BE ALTERED,ENLARGED, OR CHANGED BY ANY DISTRIBUTOR, DEALER, OR OTHER PERSONWHATSOEVER.ALL WORK UNDER THE TERMS OF THIS WARRANTY SHALL BE PERFORMED DURINGNORMAL WORKING HOURS. AL REPLACEMENT PARTS, WHETHER NEW ORREMANUFACTURED, ASSUME AS THEIR WARRANTY PERIOD ONLY THE REMAININGTIME PERIOD OF THIS WARRANTY.THE MANUFACTURER WILL NOT BE RESPONSIBLE FOR:1. Normal maintenance as outlined in the installation and servicing instructions or ownersmanual including filter cleaning and/or replacement and lubrication.2. Damage or repairs required as a consequence of faulty installation, misapplication, abuse,improper servicing, unauthorized alteration or improper operation.3. Failure to start due to voltage conditions, blown fuses, open circuit breakers or otherdamages due to the inadequacy or interruption of electrical service.4. Damage as a result of floods, winds, fires, lightning, accidents, corrosive environments orother conditions beyond the control of the Manufacturer.5. Parts not supplied or designated by the Manufacturer, or damages resulting from their use.6. Manufacturer products installed outside the continental U.S.A., Alaska, Hawaii, andCanada.7. Electricity or fuel costs or increases in electricity or fuel costs from any reason whatsoeverincluding additional or unusual use of supplemental electric heat.8. ANY SPECIAL INDIRECT OR CONSEQUENTIAL PROPERTY OR COMMERCIALDAMAGE OF ANY NATURE WHATSOEVER. Some states do not allow the exclusion ofincidental or consequential damages, so the above may not apply to you.This warranty gives you specific legal rights, and you may also have other rights which may varyform state to state.P/N 88-334Page 21Form: OG-P474-05Catalog: 53P4-744

Use with most Air Conditioning & Heating Systems including: 1 or 2 Stage Electric Cooling & Gas Heating, Heat Pump, Electric or Hydronic Heat. Meets California Title 24 Residential TOTALINE Replacement Components Division Carrier Corporation 04/01 72 74 70 C OL HEAT AUTO Mo I2:00 TOTALINEFile Size: 313KB