Ventilation TestingRotating Vane AnemometerAlnor Model RVA801AIRFLOW Model LCA301Operation and Service Manual

Copyright TSI Incorporated / 2007-2012 / All rights reserved.AddressTSI Incorporated / 500 Cardigan Road / Shoreview, MN 55126 / USAFax No.(651) 490-3824LIMITATION OF WARRANTY AND LIABILITY (effective June 2011)(For country-specific terms and conditions outside of the USA, please visitwww.tsi.com.)Seller warrants the goods sold hereunder, under normal use and service asdescribed in the operator's manual, shall be free from defects inworkmanship and material for 24 months, or if less, the length of timespecified in the operator's manual, from the date of shipment to thecustomer. This warranty period is inclusive of any statutory warranty. Thislimited warranty is subject to the following exclusions and exceptions:a. Hot-wire or hot-film sensors used with research anemometers, andcertain other components when indicated in specifications, are warrantedfor 90 days from the date of shipment;b. Pumps are warranted for hours of operation as set forth in product oroperator’s manuals;c. Parts repaired or replaced as a result of repair services are warranted tobe free from defects in workmanship and material, under normal use, for90 days from the date of shipment;d. Seller does not provide any warranty on finished goods manufactured byothers or on any fuses, batteries or other consumable materials. Only theoriginal manufacturer's warranty applies;e. Unless specifically authorized in a separate writing by Seller, Sellermakes no warranty with respect to, and shall have no liability inconnection with, goods which are incorporated into other products orequipment, or which are modified by any person other than Seller.The foregoing is IN LIEU OF all other warranties and is subject to theLIMITATIONS stated herein. NO OTHER EXPRESS OR IMPLIEDWARRANTY OF FITNESS FOR PARTICULAR PURPOSE ORMERCHANTABILITY IS MADE. WITH RESPECT TO SELLER’S BREACHOF THE IMPLIED WARRANTY AGAINST INFRINGEMENT, SAIDWARRANTY IS LIMITED TO CLAIMS OF DIRECT INFRINGEMENT ANDEXCLUDES CLAIMS OF CONTRIBUTORY OR INDUCEDINFRINGEMENTS. BUYER’S EXCLUSIVE REMEDY SHALL BE THERETURN OF THE PURCHASE PRICE DISCOUNTED FORREASONABLE WEAR AND TEAR OR AT SELLER’S OPTIONREPLACEMENT OF THE GOODS WITH NON-INFRINGING GOODS.TO THE EXTENT PERMITTED BY LAW, THE EXCLUSIVE REMEDY OFTHE USER OR BUYER, AND THE LIMIT OF SELLER'S LIABILITY FORANY AND ALL LOSSES, INJURIES, OR DAMAGES CONCERNING THEiii

GOODS (INCLUDING CLAIMS BASED ON CONTRACT, NEGLIGENCE,TORT, STRICT LIABILITY OR OTHERWISE) SHALL BE THE RETURN OFGOODS TO SELLER AND THE REFUND OF THE PURCHASE PRICE,OR, AT THE OPTION OF SELLER, THE REPAIR OR REPLACEMENT OFTHE GOODS. IN THE CASE OF SOFTWARE, SELLER WILL REPAIR ORREPLACE DEFECTIVE SOFTWARE OR IF UNABLE TO DO SO, WILLREFUND THE PURCHASE PRICE OF THE SOFTWARE. IN NO EVENTSHALL SELLER BE LIABLE FOR LOST PROFITS OR ANY SPECIAL,CONSEQUENTIAL OR INCIDENTAL DAMAGES. SELLER SHALL NOT BERESPONSIBLE FOR INSTALLATION, DISMANTLING ORREINSTALLATION COSTS OR CHARGES. No Action, regardless of form,may be brought against Seller more than 12 months after a cause of actionhas accrued. The goods returned under warranty to Seller's factory shall beat Buyer's risk of loss, and will be returned, if at all, at Seller's risk of loss.Buyer and all users are deemed to have accepted this LIMITATION OFWARRANTY AND LIABILITY, which contains the complete and exclusivelimited warranty of Seller. This LIMITATION OF WARRANTY ANDLIABILITY may not be amended, modified or its terms waived, except bywriting signed by an Officer of Seller.Service PolicyKnowing that inoperative or defective instruments are as detrimental toTSI as they are to our customers, our service policy is designed to giveprompt attention to any problems. If any malfunction is discovered,please contact your nearest sales office or representative, or callCustomer Service department at 44 (0) 149 4 459200 (UK), (800) 8742811 (USA), or (1) 651-490-2811 (International).iv

SECTION 1General DescriptionThe RVA801/LCA301 is intended formeasurement of air velocity and volume flow atreturn grilles, fume hoods, kitchen exhausts, etc.It features a 180-degree rotating head whichfunctions satisfactorily in the 0o and 180opositions. This allows the LCD display to beviewed from the front of the instrument while thehead is oriented with the flow direction.In addition, the instrument measures thetemperature of the air flow.SECTION 2SafetyObserve common sense safety precautionswhen using the RVA801/LCA301. Exercise careto ensure that the instrument does not interferewith any moving equipment or electrical wiring.This instrument is not designed for gas mixturesother than air. Use with explosive and/or otherdangerous gas mixtures is not recommendedand is at the user’s own risk.-5-

SECTION 3About the RVA801/LCA301Installing the BatteryThe RVA801/LCA301 requires a 9-volt battery.The battery is not installed when the instrumentis shipped. Remove the battery cover bypressing on the two lines and sliding downwards.Connect the battery to the flying lead, insert thebattery into the instrument and replace thebattery cover.LCD displayThe instrument will display the velocity, volumeor temperature reading as selected.Auto Shut OffThe RVA801/LCA301 has an auto shut offfeature to help preserve battery life. If no keysare pressed for 3 minutes (5 minutes intemperature mode), the instrument willautomatically turn itself off. This function cannotbe disabled by the user.-6-

SECTION 4Detailed OperationPress the ON\OFF key to turn theRVA801/LCA301 on and off. When theinstrument is turned on, it will power up in themode last used.Mode keyOn/ Off keyEnglish/Metric Unit SelectionRVA801/LCA301 instruments can display Metricor Imperial units. To select metric or imperialunits, press the Mode key while turning on the-7-

unit. Then press the trigger to select the unittype and press the Mode key again to save yoursetting.Measuring Air VelocitySelect velocity using the MODE key if required.In order to take a velocity reading, hold therotating vane in the airstream noting the flowdirection arrow on the instrument head. Keep thevane in the airstream for about five secondsbefore pressing the trigger key to take a reading.This enables the vane anemometer to reachsteady speed and the average reading will bemore accurate.To take a single reading, press the trigger keymomentarily. The instrument will display themeasured value.Press and hold the trigger key to take a sweep,or time-averaged, reading. The sweep readingwill update approximately every second. Releasethe trigger key to stop the sweep measurementand display the average value.Measuring Air VolumeThe operation for air volume measuring is thesame as air velocity. To calculate air volume, theair velocity and area (duct, grille size or Air Conedata) are required. The RVA801/LCA301rotating vane anemometer allows the user to-8-

enter the area into the instrument and get directvolume flow readings.To measure air volume, determine the crosssectional area of the duct or grille for which thevolume flow rate is required. If working in metricunits, calculations must be in m2. If working inImperial units, calculations must be in ft2. Switchthe instrument to “Area ” mode and observe thearea figure displayed from the memory. If thenew area required is larger than the onedisplayed press the trigger to increase thedisplayed area to the calculated figure. If thearea is less than the figure displayed push theMode Button to change to “Area -” mode andpress the trigger to reduce the displayed area tothe calculated figure. When the correct area hasbeen displayed use the Mode key to select therequired “Vol” mode.Note: If the area is entered incorrectly, thevolume flow rate reading will also be incorrect.The last area value will be retained in thememory even when the instrument isswitched off.Low Battery IndicationWhen the "BAT" icon appears, theRVA801/LCA301 has about 60 minutes ofbattery life remaining. If the battery is notreplaced, measurement accuracy will decrease.-9-

Serial Number DisplayThe instrument’s serial number can be verifiedby holding both the trigger and mode key whenswitching the unit on.SECTION 5Care, Maintenance and ServicePlease return the Product Registration Cardimmediately. This allows us to send servicereminders, special offers, and importantinformation about your product. Remove batteries from instrument if notused for an extended period of time. Do not bend or touch blades; accuracy willbe affected. Do not immerse in liquids. Do not drop the instrument. Use carrying case for storage, transport,and protection from dust. Use a clean damp cloth to wipe theinstrument case. Do not wipe the blades.Service Return ProcessReturn the RVA801/LCA301 for service in casethe instrument was dropped, blades were-10-

deformed, or liquid spilled on the instrument,particularly the blades.Before sending your instrument for calibration orrepair, obtain a Return Material Authorization(RMA) number by visiting our website athttp://rma.tsi.com or contacting customerservice. When obtaining an RMA number, youwill also learn the cost of service or calibrationand receive shipping instructions.Appendix AVolume Flow Rate MeasurementsUsing Air ConesIf Air Cones are used to measure the volumeflow rate, the area entered in the instrumentneeds to be related to the 100 mm vanediameter.The correct value to be entered can be found inthe Air Cone manual that comes with the cones(see side pocket of the carrying case).-11-

The following sticker can be found on the latest AirCone offerings:-12-

-13-

(This page intentionally left blank)-14-

MODEL RVA801/LCA301SPECIFICATIONS(subject to change without notice)Measurement RangeVelocity50 to 6000 fpmTemperature 32 to 140 FVolumetric1-9999000 cfmFlow Rate0.25 to 30 m/s0 to 60 C1 - 999999 l/s31 - 999999 m /h30.01 – 3000 m /s22Area Input0.043 - 900 ft0.00399 - 90 mActual range is a function of velocity and area input.Display ResolutionVelocity1 fpm0.01 m/sTemperature 1 F0.1 CAccuracyVelocity 1% reading 4 1% readingfpm 0.02 m/sTemperature 2 F 1 C14 to 140 F-10 to 60 CStorageTemperature32 to 140 F0 to 60 COperatingTemperaturePower Source 9-volt batteryApproximately 40 hours continuousBattery LifeuseDimensions11 in. 4.5 in. 280 mm 112(LWD)2.6 in.mm 65 mm10 oz.275 gWeight(excluding battery)

TSI Incorporated500 Cardigan RoadShoreview, MN 55126 USAToll Free: (800) 874-2811Tel: (651) 490-2811Fax: (651) 490-3824E-mail: customerservice@alnor.comWeb: www.alnor.comTSI Instruments Ltd.Stirling RoadCressex Business ParkHigh WycombeBucksHP12 3ST United KingdomTel: 44 (0) 149 4 459200Fax: 44 (0) 149 4 459700E-mail: info@airflowinstruments.co.ukWeb: www.airflowinstruments.co.ukFranceTel: 33 491 95 21 90Germany Tel: 49 241 523030E-mail: tsifrance@tsi.comE-mail: tsigmbh@tsi.comWebsite: www.tsiinc.frWebsite: www.tsiinc.deQuality Assured to ISO 9001:2008Part No. AFL9021485 Rev. BCopyright 2012 by TSI Incorporated