PQM (Power Quality Meter)IntroductionFeaturesThe power quality meter HC 6030 is an ideal device to power monitoring in power quality when continuous monitoring to apower system is required.HC 6030Metering of distribution feeders, transformers,generators, capacitor bands and motors The HC 6030 provides metering for current, voltage, real andreactive power, power energy, power factor, frequency energyMedium and low voltage systemsCommercial, industrial, utility Flexible control for demand load shedding, power factor, demand and 8 TOU channels with tariff to power energy. 24programmable setpoints and 3 assignable output relays al-etc. Power quality analysis.low control functions to be added for specific applications.This includes basic alarm on over / under current or voltage,A / W / Var / VA demand 8 digital inputs / pulse input totalizing unbalance, demand based load shedding, and capacitor powerfactor correction control.3 controlled relay outputs 3 analog process inputs More complex control is possible using the 8 switch inputs which also can be used for status such as breaker open /closed, or pulse counter to flow information or demand syn- 4 isolated analog outputs to a transducer function 2 pulse outputs based on KWH, KVarH, KVAH or AHchronized trigger and etc.8 channels for time of use to power energy Load sheddingThe provided measurement to main of AC power and auxil- iary of 3 analog process inputs, 8 digital inputs, the HC 6030may be used as a data gathering device for a plant automa- Power factor control Event logMinimum / maximum logger Data trend loggertion system that integrates process, instrument and electrical requirements. All monitored values are available via twoWaveform capture / harmonic analysis through 31rd Triggered trace memory ( Fault recording ) Ports : RS232 front, RS485 rear ModBus RTU protocol metering digital communication ports RS485 and RS232 running theModBus protocol. If analog values are required for directinterface to a PLC, and of the monitored values can be outputto one of 4 isolated analog outputs and 2 pulse outputs. Process variables can be measured using 3 analog inputs. Otherplant personnel can connect a front panel RS232 communication port to a PC for simultaneous access of information.The quality of the power system is important with increasinguse of electronic loads such as switching power or variablefrequency drives. With the HC 6030 auxiliary input / output,any phase current / voltage can be displayed and the harmonic content calculated. By knowing the harmonicdistribution, action can be taken to prevent overheatedtransformer, motors, capacitors, neutral wires and nuisancebreaker trips. Redistribution of system loading can also bedetermined. Waveform and chart recorder printouts availablefrom the HC 6030 assist in problem diagnosis.1

PQM (Power Quality Meter)MeteringzEach voltage and current is sampled 64 times per cycle forzHC 6030Issue control commandsLoad all setpoints from a filez Change individual setpoints0.2% accuracy true RMS measured values.z A1, A2, A3, A0, AEThe standard version the HC 6030 comes complete with azVa, Vb, Vc, Vab, Vbc, Vca, VPE, VLEz W, Var, VA, total & individualfront RS232 port. The RS232 port can be used for datacollection, printing reports or problem analysis without dis-Hz & phase rotation sequencez True PF crest & K factorturbing the main communication interface to rear RS485 port.zUpgxpansionUpgrr ade to futurfuturee eexpansionWH, VarH, VAH, AHz Demand : A, W, Var, VAzFlash memory is used for firmware storage within the HC6030. This allows future product upgrades to be loaded viaA keyboard and 3 illuminated VFD module each with 9 character display are used for field programming, setup monitor-the serial port.Initially the HC 6030 meters can be used as stand-alone units.ing values and status.Open architecture allows connection to other ModBus compatible system for over all process monitoring and control.Setpoints to AlarmsAlarmsOptionAny of the assignable output relays may be used to triggerand alarm for specific applications.ConditionOver currentApplicationMotors / transformersUnder currentNeutral currentPumps / compressorsLeakage / unbalanceCurrent unbalanceOver voltageMotorsEquipment protectionUnder voltagePhase sequenceMotors / load transferPumps / equipmentOver frequencyUnder frequencyGeneratorsLoad sheddingPower factorSwitch inputCapacitor banksProcess control8 status input : 8 status inputs with internal DC28V powered,can be configured to 8 status inputs (break condition) or to7 counter inputs and one demand synchronized input.4 analog output : 4 isolated analog outputs can be used toreplace 4 or more analog transducers.Output signals can be selected from any of the measuredparameters.z 3 analog inputs : 3 analog inputs for process variables(such as temperature. Water level or flow rate etc.) Can bemonitored and used for control.z2 energy pulse outputs: 2 energy pulse outputs of WH andVarH can be used to energy management or used to re-place energy transducer.z 24 setpoints with 3 relay control outputCommunicationsIntegrate process, instrumentation and electrical requirementsControlin a plant automation system by connecting HC 6030 meterstogether to a DCS or SCADA system. A PC running the HC 60303 output relays / 8 switch inputs / measured parameters fromthe standard HC 6030 can be combined with setpoints andcan change system setpoints, monitor values, status andalarms. Continuous monitoring minimizes process downtimeinput / outputs for control applications. With the controloption, 3 output relays and 8 switch inputs are added alongby immediately identifying potential problems due to faultsor changes from growth.with programmable setpoints. Output relays can also be controlled via the communication port or assigned to differentsetpoints for user programming to accommodate manysituations. Possibilities include:RS485 ModBus 1,200 19,200 bpsz RTU SCADA system componentzMeasure actual valuesz Read statusz2

PQM (Power Quality Meter)zHC 6030 PC prproo g r amUnder current alarm for pumpsOver / under voltage for generatorsz Unbalance alarm for rotating machineszThe PQM PC program is a Windows based program for theHC 6030. It can be used to enter setpoints, read meteredvalues, monitor status and evaluate power quality. All dataDual level power factor for capacitor bank switchingz Under frequency / demand output for load shedding rezcontinuously gathered by the HC 6030 can be transferred toa third party software program for display, control or analy-sulting in power cost savingsz KWH, KVarH and KVAH pulse output for PLC interfacezsis via the communications interface.Once all setpoints have been entered they can be downloadedFault recorder for 3 voltages and 3 currentsinto any HC 6030 or stored in a file with a tag name for laterreference.Po w er analysisanalysisData logger (trending): trending is useful as a troubleshooting aid when a problem is detected. Measured values can beScreens are available for monitoring all measured values suchas current, voltage or power. Status of alarms and controlselected and plotted with a programmable sampling rate tosuit the time interval of interest. The generated chart re-settings can also be displayed.Voltage and current wave shape can give important informa-corder screen can be printed or exported to other programsfor report writing.tion about what is happening on a system. For example, nonlinear loads such as computers or variable speed drives mayHarmonic analysis: non linear loads such as variable speeddrives, computers and electronic ballasts can cause harmon-introduce distortion that indicates filtering is required.Harmonic analysis may reveal excessive harmonic contentics which may lead to problems such as nuisance breakertripping, telephone interference, transformer, capacitor orrequiring a dreaded transformer or larger neutral wire. Earlywarning of these problems can prevent equipment damagemotor overheating. For fault diagnosis such as detecting undersized neutral wiring, need for a harmonic rated transformer,or nuisance breaker tripping.or effectiveness of harmonic filters, details of the harmonicspectrum are useful and available with the power analysisoption.z Waveform capture : voltage and current waveforms can becaptured and displayed on a PC using the HC 6030 PCprogram supplied with the HC 6030 or using third partysoftware. Distorted peaks or notches from SCR switchingprovide clues for taking corrective action.zHC 6030Event logger : alarms, setpoint triggers, input and outputevents can be stored in a 200 event record and time / datestamped by the internal clock. This is use full for diagnosing problems and system activity. Minimum and maximumvalues are also continuously up dated and time stamped.z Trace memory : the HC 6030 can be configured to record16 to 64 cycle of data length on all voltage and currentinput based on setpoint activation to under voltage, overvoltage, over current or switch input state change and etc.3

PQM (Power Quality Meter)HC 6030Model & Ordering NumberModel : HC 6030Ordering :HC 6030 - A - 5.0A - H - 3 - NVersionOptionN : No optionCurrent Input1.0AA : DC Analog output x 4B : Pulse output x 25.0AC : Relay control output x 3Alarm setpoint x 24PowerH : AC 80-260V, DC 80-330VD : Status input x 8E : DC Analog input x 3L : DC 20-60VF : Trigger to memory trace logCommunication Port3 : RS-485 RS-232Y : Special OrderingSpecificationMeasured power parameterMeasuredpowparameterameterssParam.VP x 3VL x 3Ax4WattsVarsVAPFWHVarHHzPhaseRotationAccuracy Phase1 Phase2 Phase3 Phase00.15% fsVP1VP2VP30.15% fsVL1VL2VL30.15% fsA1A2A3A00.25% fsW1W2W30.25% fsVar1 Var2 Var30.25% fsVA1VA2VA30.25% fsPF1PF2PF30.8% rd1% rd0.03% rdTotalVPEVLEWVarVAPFWHVarH4

PQM (Power Quality Meter)z All measured display scaled to primary readoutz Controloutput (CO )z 3 relay outputs of dry contact / form Ccontact material / gold plate silver alloyz Normal operation250Vac / 30Vdc, 10A resistive250Vac / PF 0.4, 6A inductive30Vdc / t 7ms, 6A inductivez Interrupting capacity300Vac, 10A250Vdc, resistive 0.32A maximum, t 7ms125Vdc, resistive 0.5A maximum, t 7msz Analog input ( AI )z Accuracy, 0.5% fsz 3 differential analog inputs / process variablesz Standard input 4-20mA / 0-20mAz Common mode voltage E100V maximumz Option input 0-10V / 0-5V / 0-1V / 1-5V / 2-10Vz Analog output ( AO )z Accuracy, 0.5% fsz 4 isolated analog outputsz Standard output 4-20mAdc / load O 500Ωz ConfigurableMeasured parametersInput range, unipolar / bipolarz Pulse output ( PO )z 2 pulse outputs photo-isolatedz ConfigurableParameter , WH / VarH / VAH / AHUnit, E1WH / E1QH / 1VAH / 0.01AHz Pulse width / 50% duty cyclez StabilityTemperature range (-10 to 50 C) , max. 100 ppm/ Cz Display 5 digits to V / A / W / Var / VA / PFz Display 8 digits to WH / VarHz Notez VP1 / VP2 / VP3 / VPE, phase to neutral voltagez VL1 / VL2 / VL3 / VLE, line to line voltagez A1 / A2 / A3 / AE/ A0, phase currentz VPE / VLE / AE, 3 phase averagedz A0, neutral currentz PF1 / PF2 / PF3, coincident to conversion elementz WH / VarH accuracy vs limited input rangeVoltage P 50VCurrent P 10% of ratingPF P 0.5Main AC power inputz Phase and wiresz 3 phase 4 wires wye 3VTsz 3 phase 4 wires wye 2VTsz 3 phase 3 wiresz Single phase 3 wiresz Single phase 2 wiresz Rangez Voltage : 10 600Vz Current : suitable for CT secondary rating (optional)Maximum 7.5A for 5A ratingMaximum 1.2A for 1A ratingz Power maximum 6500 ( W / Var / VA )z Frequency : 40 70Hzz Triggered trace memory / fault recording rangeV O 600VA O 8 x ratedz Burdenz Voltage 0.2VA at 600V / phase 0.02VA at 120V / phasez Current 0.1VA at ratingz Overload capabilityz Current ( 5A )2 x rated continuous10 x rated 30 seconds25 x rated 2 seconds50 x rated 1 secondsz Voltage750V continuous1000V 10 seconds1200V 3 secondsA uxiliar y monitoringz Digital input ( DI )z 8 status input / internal powered of DC 24Vz Input / dry contactz ConfigurableSwitch statusPulse input ( pulse width minimum P 250 ms )synchronized trigger of demandHC 6030DisplayVFD / 0.28" / green color; 3 rows, 9 alphanumerics eachCommunication por tCommunicaunicationDual communication ports RS485 and RS232Modbus RTU protocolRTCMaximum deviation 5 seconds in 24 hoursTime for year / month / day / hour / minute / secAlarm setpoints loAlarmlogg gerz 24 setpointsOver, under, unbalance, status change, reversed phasesequence functionCircuital set-valueDead bandTime delay5

PQM (Power Quality Meter)HC 6030z DI, input presetData memorDatamemoryyDI1 - DI8 configurableSwitch statusPulse inputSynchronized trigger to demandz Analog output ( AO1 - AO4 )z Analog input ( AI1 - AI3 )z Preset pulse output, WH / QHPreset LED indicator, WH / QH / AH / VAHz 24 alarm setpoints with trigger parameter, dead band,time delay and operation to controlled relay outputz 3 assigned control relay outputz Reset to maximum / minimum logz Trend logz Triggered trace memoryz Time base correctionz Time of use with tariff to power energy ( 8 channels ) 1M bitsCell backup 400000 hours continuous at power OFFData loggerz Waveform capture logSample rate 64 / Hz, length 2 cycleParameter / 3 voltages and 3 currentsz Trend logger20 parameters with time-stamped VP1, VP2, VP3, VPE, VL1,VL2, VL3,VLE, A1, A2, A3, A0, AE, W, Var, VA, PF, FQ, Vubl,AublSample rate 15 / 30 / 60 minute per sampleLength 960 datas / parameterLength 10 days / 15 minutes, 40 days / 60 minutesz Event logger200 events with time-stampedStatus change of switch inputActivation of setpoints / alarmsOperation of controlled relay outputFailure in communication to comportFailure in self testProgramming accessTrace memory triggeredPower ON / OFFz Control output3 assignable relay outputsz Maximum / minimum logger20 parameters with time-stamped VP1, VP2, VP3, VPE,VL1, VL2, VL3, VLE, A1, A2, A3, A0, AE, W, Var, VA, PF,FQ, Vubl, Aublz Triggered trace memory / fault recordingz Recorded 6 parameters of three phase voltages &cu

PQM (Power Quality Meter) HC 6030 Metering Each voltage and current is sampled 64 times per cycle for 0.2% accuracy true RMS measured values. zA1, A2, A3, A0, A E zVa, Vb, Vc, Vab, Vbc, Vca, V PE, VLE zW, Var, VA, total & individual zHz & phase rotation sequence zTrue PF crest & K factor zWH, VarH, VAH, AH zDemand : A, W, Var, VA A keyboard and 3 illuminated VFD module each with 9 char-