With Installation Instructions For The Installer . - Paloma Water Heaters

Transcription

Use & Care ManualWith Installation Instructions for the InstallerDirect Vent GasTankless Water Heater!Warning: This water heater is not suitablefor use in manufactured (mobile) homes!The purpose of this manual is twofold: one, to provide the installer withthe basic directions and recommendations for the proper installationand adjustment of the water heater; and two, to the owner–operator,to explain the features, operation, safety precautions, maintenance andtroubleshooting of the water heater. This manual also includes a partslist.It is very important that all persons who are expected to install, operateor adjust this water heater read the instructions carefully so they mayunderstand how to perform these operations. If you don’t understandthese instructions or any terms within it, seek professional advice.Any questions regarding the operation, maintenance, service or warrantyof this water heater should be directed to the seller from whom it waspurchased. If additional information is required, refer to the section onIf You Need Service.Do not destroy this manual. Please read carefully and keep in a safeplace for future reference.!!!Recognize this symbol as an indication of Important SafetyInformation!!California Proposition 65 Warning: This product containschemicals known to the State of California to cause cancer, birthdefects or other reproductive harm.WARNING: If the information in these instructions is not followed exactly,a fire or explosion may result, causing property damage, personal injury or death.FOR YOUR SAFETY!— Do not store or use gasoline or otherflammable vapors or liquids or othercombustible materials in the vicinity ofthis or any other appliance. To do so mayresult in an explosion or fire.— WHAT TO DO IF YOU SMELL GASDo not try to light any appliance.Do not touch any electrical switch; do notuse any phone in your building.Immediately call your gas supplierfrom a neighbor’s phone. Follow thegas supplier’s instructions.If you cannot reach your gas supplier, callthe fire department.Do not return to your home until authorizedby the gas supplier or fire department.— Improper installation, adjustment,alteration, service or maintenance can causeproperty damage, personal injury or death.Refer to this manual. Installation and servicemust be performed by a qualified installer,service agency or the gas supplier.DESIGNModelsPH2-20R DVSN (Natural Gas); PH2-20R DVSP (L.P. Gas)PH2-25R DVSN (Natural Gas); PH2-25R DVSP (L.P. Gas)PH2-28R DVSN (Natural Gas); PH2-28R DVSP (L.P. Gas)31-93681-00CERTIFIEDRCERTIFIED AP15421 (11/09)

Safety InformationFOR YOUR RECORDSSafety Precautions . . . . . . . 3–6Write the model and serial numbers here:LP Gas Models . . . . . . . . . . . 5#Installation Instructions#Location . . . . . . . . . . . . . . . . . .7You can find them on a label on the appliance.Inspect Shipment . . . . . . . . . . .8Staple sales slip or cancelled check here.Venting . . . . . . . . . . . . . . . 9-14Proof of the original purchase date is needed to obtain serviceunder the warranty.Water Connections . . . . 15, 16Relief Valve . . . . . . . . . . . . . .17Gas Supply . . . . . . . . . . . . . . 18High Altitude . . . . . . . . . . . . .18Remote Control . . . . . . . 19, 20Electrical Connection . . . . . .21Typical Installation . . . . . . . .22Pipe Insulation . . . . . . . . . . . .23Installation Checklist . . . . . . .24READ THIS MANUALInside you will find many helpful hints on how to use andmaintain your water heater properly. A little preventive careon your part can save you time and money over the life of yourwater heater.You’ll find many answers to common problems inthe Troubleshooting Guide. If you review the chart ofTroubleshooting Tips first, you may not need to call for service.Operating InstructionsLighting Instructions . . . . . . 25Water Temperature . . . . 26, 27Care and CleaningMaintenance . . . . . . . . . . . . . 28READ THE SAFETY INFORMATIONYour safety and the safety of others are very important. Thereare many important safety messages in this manual and on yourappliance. Always read and obey all safety messages.Housekeeping . . . . . . . . 28, 29Vent Inspection . . . . . . . . . . .29!Burner Inspection . . . . . . . . 29Extended Shut-Down . . . . . .29Draining . . . . . . . . . . . . . . . . 30Freeze Protection . . . . . . . . . .30Troubleshooting TipsBefore You CallFor Service . . . . . . . . . . . 31, 32Customer ServiceParts List. . . . . . . . . . . . . . . . 33If You Need Service . . . . . . .36This is the safety alert symbol. Recognize this symbolas an indication of Important Safety Information!This symbol alerts you to potential hazards that cankill or hurt you and others.All safety messages will follow the safety alert symbol andeither the word “DANGER”, “WARNING”, “CAUTION”or “NOTICE”.These words mean:!DANGERAn imminently hazardous situationthat will result in death or seriousinjury.!WARNINGA potentially hazardous situation thatcould result in death or serious injuryand/or damage to property.!CAUTIONA potentially hazardous situation thatmay result in minor or moderateinjury.Qualified Installers Only!Maximum TemperatureAdjustment . . . . . . . . . . . . . . 34Minumum TemperatureAdjustment . . . . . . . . . . . . . . 35High Altitude Adjustment . . .352Notice:Attention is called to observe aspecified procedure or maintaina specific condition.

IMPORTANT SAFETY INFORMATION.READ ALL INSTRUCTIONS BEFORE USING.Be sure to read and understand the entire Use and Care Manual before attempting to install or operate thiswater heater. It may save you time and money. Pay particular attention to the Safety Instructions. Failure tofollow these warnings could result in serious bodily injury or death. Should you have problems understandingthe instructions in this manual, or have any questions, STOP, and get help from a qualified service technician,or the local gas utility.DANGER!INSTALL AND PROPERLY VENT THE WATER HEATER Failure to install and properly vent the water heater to the outdoors as outlined in theVenting Section of the Installation Instructions in this manual can result in unsafe operationof the water heater. To avoid the risk of fire, explosion or asphyxiation from carbonmonoxide, never operate this water heater unless it is properly vented and has an adequateair supply for proper operation.Be sure to inspect the vent terminal, the air intake, and the concentric vent system on thewater heater for proper installation at initial start-up; and at least annually thereafter. Referto the Care and Cleaning section of this manual for more information regarding concentricvent system inspection.WARNING!Gasoline, as well as other flammable materials and liquids (which include, but are notlimited to adhesives, solvents, paint thinners etc.), and the vapors they produce areextremely dangerous. DO NOT handle, use or store gasoline or other flammable orcombustible materials anywhere near or in the vicinity of a water heater or any otherappliance. Be sure to read and follow the labels on the water heater, as well as the warningsprinted in this manual. Failure to do so can result in property damage, bodily injury ordeath.DANGERFLAMMABLESFlammable VaporsVapors from flammableliquids will explode andcatch fire causing death orsevere burns.Do not use or store flammableproducts such as gasoline,solvents or adhesives in thesame room or area near thewater heater.Keep flammable products:1. far away from heater,2. in approved containers,3. tightly closed and4. out of children's reach.Installation:Do not install water heaterwhere flammable products willbe stored or used unless themain burner flame is at leastWater heater has a mainburner flame.The main burner flame:1. which can come onat any time and2. will ignite flammablevapors.Vapors:1. cannot be seen,2. are heavier than air,3. go a long way on thefloor and4. can be carried fromother rooms to themain burner flame byair currents.18" above the floor. This willreduce, but not eliminate, therisk of vapors being ignitedby the main burner flame.Read and follow water heater warnings and instructions. Ifowners manual is missing, contact the retailer or manufacturer.3

IMPORTANT SAFETY INFORMATIONREAD ALL INSTRUCTIONS BEFORE USING.! DANGER!WATER TEMPERATURE SETTINGSafety and energy conservation are factors to be considered when selecting the watertemperature setting of a water heater’s remote control. Water temperatures above125 F (52 C) can cause severe burns or death from scalding. Be sure to read and followthe warnings outlined on the label pictured below.Time/Temperature Relationship in Scalds!DANGERWater Temperature120 F (49 C)125 F (52 C)130 F (54 C)135 F (57 C)140 F (60 C)145 F (63 C)150 F (66 C)155 F (68 C)HOTTime To Produce a Serious BurnMore than 5 minutes11/2 to 2 minutesAbout 30 secondsAbout 10 secondsLess than 5 secondsLess than 3 secondsAbout 11/2 secondsAbout 1 secondTable courtesy of Shriners Burn InstituteBURNThe chart shown above may be used as a guide indetermining the proper water temperature for your home.!Water temperature over 125 Fcan cause severe burnsinstantly or death from scalds.Children, disabled and elderly areat highest risk of being scalded.See instruction manual beforesetting temperature at waterheater.Feel water before bathing orshowering.Temperature limiting valves areavailable, see manual.DANGER: Households with small children, disabledor elderly persons may require a 120 F (49 C) or lowertemperature setting to prevent contact with “HOT” water.Maximum water temperature occurs while burner is on.To find water temperature being delivered, turn on a hotwater faucet and place a thermometer in the water streamand read the thermometer. (See page 26 & 27 for moredetails.)The temperature of the water at the outlet of the waterheater can be regulated by setting the temperature onRemote Control. The remote control was set at 100 F(38 C) before it was shipped from the factory.The diagram to the bottom left illustrates the RemoteControl and how to adjust the water temperature.Notice:Displayshows F only.PRIORITY FPOWERON/OFFHigher (Hotter)Lower (Cooler)85 100 102 104 106 108 110 112 114 116 118 120* 125 130 140 F2938 39 40 41 42 43 44 46 47 48 49* 52 54 60 C* Temperatures 85 F(29 C) and up to 140 F (60 C) can beachieved with the Main (UMC-117) remote control. See page34 & 35 for minimum and maximum temperature adjustment.4Notice: The factory setting allows operating temperaturesbetween 100 F (38 C) and 120 F (49 C). Temperaturesof 85 F (29 C) and up to 140 F (60 C) can be achievedwith the MAIN (UMC-117) remote control. Temperaturesof 85 F (29 C) can be achieved with the Bath (USC-117or USC2-117) remote control. Only qualified servicepersonnel should perform this adjustment. Only factoryauthorized remote control(s) should be used.Notice: When this water heater is supplying generalpurpose hot water requirements for use by individuals,a thermostatically controlled mixing valve for reducingpoint of use water temperature is recommended to reducethe risk of scald injury. Contact a licensed plumber or thelocal plumbing authority for further information.

DANGER!NATURAL GAS AND LIQUEFIED PETROLEUM MODELSBoth LP and natural gas have an odorant added to aid in detecting a gas leak. Somepeople may not physically be able to smell or recognize this odorant. If you are unsure orunfamiliar with the smell of LP or natural gas, ask the gas supplier. Other conditions, such as“odorant fade”, which causes the odorant to diminish in intensity, can also hide or camouflagea gas leak.Notice: If a gas leak is present or suspected:Water heaters utilizing LP gas are differentfrom natural gas models. A natural gasDo not attempt to find the cause yourself.water heater will not function safely on LPDo not try to light any appliance.gas and vice versa.No attempt should ever be made toconvert the water heater from natural gasto LP gas. To avoid possible equipmentdamage, personal injury or fire, do notconnect the water heater to a fuel type notin accordance with the unit data plate;propane for propane units and natural gasfor natural gas units. These units are notcertified for any other fuel type.LP appliances should not be installed belowgrade (for example, in a basement) if suchinstallation is prohibited by federal, stateand/or local laws, rules, regulations orcustoms.Do not touch any electrical switch.Do not use any phone in your building.Leave the building immediately and makesure your family and pets leave also.Leave the doors open for ventilation andcontact the gas supplier, a qualified serviceagency or the fire department.Stay away from the building until theservice call has been made, the leak iscorrected and a qualified agency hasdetermined the area to be safe.Propane or LP gas must be used with greatcaution. It is heavier than air and willcollect first in lower areas, making it hardto detect at nose level.Before attempting to light the water heater,make sure to look and smell for gas leaks.Use a soapy solution to check all gas fittingsand connections. Bubbling at a connectionindicates a leak that must be corrected.When smelling to detect a gas leak, be sureto sniff near the floor also.Gas detectors are recommended in LPand natural gas applications and theirinstallation should be in accordancewith the detector manufacturer’srecommendations and/or local laws,rules, regulations or customs.It is recommended that more than onemethod, such as soapy solution, gasdetectors, etc., be used to detect leaksin gas applications.5

IMPORTANT SAFETY INFORMATIONREAD ALL INSTRUCTIONS BEFORE USING.!WARNING!For your safety, the information in this manual must be followed to minimize the riskof fire or explosion, electric shock, or to prevent property damage, personal injury orloss of life.FOR INSTALLATIONS IN THE STATE OF CALIFORNIACalifornia Law requires that water heaters must be braced, anchored or strapped to resistfalling or horizontal displacement due to earthquake motions. For water heaters up to 52gallon capacity, a brochure with generic earthquake bracing instructions can be obtained from:Office of the State Architect, 1102 Q Street, Suite 5100, Sacramento, CA 95814 or you may call916-445-8100 or ask a water heater dealer.However, applicable local codes shall govern installation. For residential water heatersof a capacity greater than 52 gallons or tankless-style, consult the local building jurisdictioncode for acceptable bracing procedures.SAFETY PRECAUTIONSHave the installer show you the location of the gas shut-off valve and how to shut it offif necessary. Turn off the manual shut-off valve if the water heater has been subjectedto overheating, fire, flood, physical damage or if the gas supply fails to shut off.Read this manual entirely before installingor operating the water heater.Use this appliance only for its intendedpurpose as described in this Use and CareManual.Do not attempt to repair or replace anypart of your water heater unless it isspecifically recommended in this manual.All other servicing should be referred to aqualified technician.Be sure your appliance is properly installedin accordance with local codes and theprovided installation instructions.READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY.SAVE THESE INSTRUCTIONS6

Installing the water heater :This water heater must be installed in accordance with these instructions, local codes, utility companyrequirements and/or in the absence of local codes, use the latest edition of the American National Standard/National Fuel Gas Code. A copy can be purchased from either the American Gas Association, 400 NorthCapitol Street Northwest, Washington, DC 20001 as ANSI standard Z223.1 or National Fire ProtectionAssociation, 1 Batterymarch Park, Quincy, MA 02269 as NFPA 54. In Canada, the latest edition of the CSAB149.1 Natural Gas and Propane Installation, and the Canadian Electrical Code, CSA C22.1 Part 1, in theabsence of local codes.Location of Water HeaterThe water heater should not be located inan area where leakage of the heat exchangeror connections will result in damage to thearea adjacent to it or to lower floors of thestructure.When such areas cannot be avoided, it isrecommended that a suitable catch pan,adequately drained to a safe location beinstalled under the water heater.! WARNING:Combustible constructionrefers to adjacent wallsand ceilings and should notbe confused withcombustible or flammableproducts and materials.Combustible and/orflammable products andmaterials should never bestored in the vicinity of thisor any gas appliance.Minimum Clearance fromCombustible andNon-CombustibleConstruction.0” (Zero)(0 cm)0” (Zero)(0 cm)1/2” (min)(1.3 cm)1/2” (min)(1.3 cm)12” (min)(30 cm)(24” (61cm) minimum isrecommended for service)Top 12" (30 cm)Bottom 12" (30 cm)Front 12" (30 cm)Back 0"*Side 1/2" (1.3 cm)Concentric Vent 0"* (with support bracket)A gas fired water heater or any other applianceshould not be installed in a space where liquidswhich give off flammable vapors areto be used or stored. Such liquids includegasoline, LP gas (butane or propane), paintor adhesives and their thinners, solventsor removers.Because of natural air movement in a room orother enclosed space, flammable vapors can becarried some distance from where their liquidsare being used or stored. The open flame ofthe water heater’s main burner can ignite thesevapors causing an explosion or fire whichmay result in severe burns, death or propertydamage.The water heater must be located so it is notsubject to physical damage, for example, bymoving vehicles, area flooding, freezing, etc.If the water heater is installed in a garage, itshould be installed so that the direct ignitionsystem and main burner are no less than 18inches (45 cm) above the garage floor.Raising the gas fired water heater will reduceBUT NOT eliminate the possibility of lightingthe vapor of any flammable liquids which maybe improperly stored or accidentally spilled.The water heater should be installed asclose as practical to the vent terminationto minimize vent length and the number ofelbows required for venting.The water heater should be installed withthe proper venting materials and terminationsuitable for Category III venting or Rheemapproved venting.A fire stop plate should be installed at everypenetration of a floor or ceiling if the vent isnot running in a fire rated shaft.Failure to install and properly vent the waterheater to the outdoors as outlinedin the Venting Section of this manualcan result in unsafe operation.Long hot water lines should be insulated toconserve water and energy.The water heater and water lines shouldbe protected from exposure to freezingtemperatures.Do not install the water heater inbathrooms, bedrooms, any occupied roomsnormally kept closed, or in outdoor areas.Do not install water heater where subjectto vibrations.Do not install the water heater inRecreational Vehicles, Mobile Homes,Boats and other Watercrafts.Do not install the water heater near ventsfor heating or cooling. A minimum of 4 feet(1.2 m) should be maintained.Minimum water heater clearance fromcombustible and non-combustibleconstruction is 1/2” (1.3 cm) sides, 0” rear(with support bracket); 12” (30 cm) fromthe bottom; 12” (30 cm) from the front ofthe water heater; and 12” (30 cm) fromthe top (24” [61 cm] from front and top isrecommended for servicing purposes).Maintain a minimum clearance of0” (0 cm) around the concentric ventpipe to combustible or non-combustibleconstruction, unless otherwise specifiedby vent manufacturer or installed in anenclosed space. If the clearances stated onthe Instruction/Warning Label, located onthe front panel of the heater differ, installthe water heater accordingto the clearances stated on the label.7

Installing the water heater:NOTICE: The water heatershould not be installed nearan air supply containinghalogenated hydrocarbonsand/or other corrosives.Corrosive AtmospheresThe air in beauty shops, dry cleaningestablishments, photo processing labs,and storage areas for liquid and powderedbleaches or swimming pool chemicalsoften contains such halogenatedhydrocarbons and/or corrosives.An air supply containing halogenatedhydrocarbons may be safe to breathe,but when it passes through a gas flame,corrosive elements are released thatwill shorten the life of any gas burningappliance.Propellants from common spray cansor gas leaks from A/C and refrigerationequipment are highly corrosive afterpassing through a flame.The water heater warranty is voided whenfailure of the heater is due to operation ina corrosive atmosphere.Inspect ShipmentInspect the water heater for possible damage. Check the markings on the rating plate ofthe water heater to be certain the type of gas supplied corresponds to the water heaterrequirements. Verify all included parts are present (see below).PRIORITYWood Screw x 5pcs. FPOWERON/OFFDrain TubingRemote ControlAssembly KitWasher x 4 pcs.Use & Care ManualWith Installation Instructions for the InstallerResidential GasTankless Water HeatersWarning: This water heater is not suitable foruse in manufactured (mobile) homes!The purpose of this manual is twofold: one, to provide the installer withthe basic directions and recommendations for the proper installation andadjustment of the water heater; and two, to the owner–operator, toexplain the features, operation, safety precautions, maintenance andtroubleshooting of the water heater. This manual also includes a partslist.It is imperative that all persons who are expected to install, operate oradjust this water heater read the instructions carefully so they mayunderstand how to perform these operations. If you don’t understandthese instructions or any terms within it, seek professional advice.Any questions regarding the operation, maintenance, service orwarranty of this water heater should be directed to the seller from whomit was purchased. If additional information is required, refer to thesection on How to Obtain Service Assistance.Do not destroy this manual. Please read carefully and keep in a safeplace for future reference.!!Recognize this symbol as an indication of Important SafetyInformation!!California Proposition 65 Warning: This product containschemicals known to the State of California to cause cancer, birthdefects or other reproductive harm.WARNING: If the information in these instructions is not followed exactly,a fire or explosion may result causing property damage, personal injury or death.! FOR YOUR SAFETY!— Do not store or use gasoline or otherflammable vapors or liquids or othercombustible materials in the vicinity of this orany other appliance. To do so may result in anexplosion or fire.— WHAT TO DO IF YOU SMELL GASl Do not try to light any appliance.l Do not touch any electrical switch; do notuse any phone in your building.l Immediately call your gas supplier from aneighbor’s phone. Follow the gassupplier’s instructions.l If you cannot reach your gas supplier, callthe fire department.l Do not return to your home until authorizedby the gas supplier or fire department.— Improper installation, adjustment,alteration, service or maintenance can causeproperty damage, personal injury, or death .Refer to this manual. Installation and servicemust be performed by a qualified installer,service agency or the gas supplier.DESIGNPrinted in USARemote Control Cable8Manual ApplianceGas Shut-off ValveCERTIFIEDTankless Unit Use & Care Manual

The water heater must be installed with a 3”/5” diameter UL approved Category III Concentric StainlessSteel appliance concentric vent pipe or Rheem approved concentric vent pipe.DANGER: Failure toinstall the appliance ventadapter and properly vent thewater heater to the outdoorsas outlined in the Ventingsection of this manual willresult in unsafe operation ofthe water heater, causing death,serious injury, explosion,or fire. To avoid the riskof fire, explosion, orasphyxiation from carbonmonoxide, NEVER operate thewater heater unless it isproperly vented and hasadequate air supply for properoperation as outlined in theVenting section of this manual.WARNING: Use only 3”/5”UL approved Category IIIConcentric Stainless Steel ventmaterial or Rheem approvedconcentric vent material. Noother vent material ispermitted.WARNING: Followconcentric ventmanufacturer’s installationinstructions and theirrecommended clearances tocombustibles.VentingThe installation of venting must complywith national codes, local codes and thevent manufacturer’s instructions.The water heater must be vented to theoutdoors as described in these instructions.DO NOT connect this water heater to achimney. It must be vented separately fromall other appliances.All concentric vent components (adapters,pipe, elbows, terminals, etc.) should beRheem approved Stainless Steel VentingMaterial(e.g. AL29-4C).The specified vent termination must be used.(Refer to pages 13 and 14 for an example ofthe concentric vent.)Use the screws provided to connectthe concentric vent pipe with the antidisconnection joint.The unit can be vented either horizontallyor vertically.Concentric vent pipe runs must beadequately supported along both horizontaland vertical runs.The maximum recommended unsupportedspan should be no more than five (5) feet(1.5 m). Support isolation hanging bandsshould be used. DO NOT use wire. (Seediagram)Notes on pre-existing vent:If the water heater is being installed as areplacement for an existing water heater, athorough inspection of the existing ventingand air intake system must be performedprior to any installation work. Verify that thecorrect materials, vent lengths and terminallocations as detailed in this Use and CareManual have been met. Carefully inspect theentire venting and air intake system for anysigns of cracks or fractures, particularly atthe joints between elbows or other fittingsand the straight runs of vent pipe. Check thesystem for signs of sagging or other stressesin the joints as a result of misalignment ofany components in the system. If any ofthese conditions are found, they must becorrected in accordance with the ventinginstructions in this manual before completingthe installation and putting the water heaterinto service.See the back page of this manualfor additional requirements for theCommonwealth of Massachusetts.NO!YES!Venting LengthsNumber of90 elbows(bends)MaximumLength ofStraight Pipe139’(12.0 m)237' 6"(11.5 m)336"(11.0 m)434' 6"(10.5 m)533'(10.0 m)631'6"(9.5 m)MAXIMUM VENT LENGTH:The system will not operate if there isexcessive restriction (pressure drop) in theventing system. A maximum 39’(12.0 m) ofvent pipe may be used provided there is onlyone 90 elbow in the system. If additionalelbows are required: two elbows can be usedwith 37’ 6"(11.5 m), three elbows can be usedwith 36’ (11.0 m) or four elbows can be usedwith 34’ 6" (10.5 m) of vent pipe. (See table)A 94 elbow is equivalent to 1’6” (.5 m) ofstraight pipe. A 45 elbow is equivalent to9” (.25 m) of straight pipe.installing the drain tube to the condensationtrap. For horizontal installation with lessthan 10’ (3.1m), a 94 elbow is required.MINIMUM VENT LENGTH: The ventingmay be as short as 12” (30cm), in additionto installation of one 94 elbow and onevent termination to the outdoors through aside wall (Total equivalent vent length: 30”(76cm)).Notice: Make sure that the seam of the innervent pipe in horizontal runs is toward the topof the installation (see diagram).The vent termination does not countin equivalent to pipe calculation whendetermining total vent lengths.The vent should be installed with a slightdownward slope of 1/4” per foot ofhorizontal run toward the vent terminal (seediagram). This ensures that any condensateformed during operation of the unit isevacuated from the appliance and to preventrain from entering the appliance.An upward slope toward the vent terminal isnot acceptable for horizontal venting withoutVent Seam9

Installing the water heater:Venting Through Closed Spaces1/4" per footdownward slopeWall Plates94 ElbowFireStopVent Pipe12” (min)(30 cm)Follow local codes and vent manufacturer’s installation instructions.For maintenance and inspection purposes two (2) inspection accesspanels large enough to allow access for venting inspection may berequired. One (1) of these access panels should be close to where theconcentric vent pipe enters the ceiling. The other access panel shouldbe near the vent termination.CeilingBoardInspectionAccess Panel #1(optional)InspectionAccessPanel #2(optional)Appliance Vent AdapterMetal Fab Inc., standard concentric vent pipecan be installed into the water heater collarwithout an appliance vent adapter. However,other Rheem approved vent manufacturer pipecannot be installed without a UL approvedCategory III Stainless Steel applianceconcentric vent adapter.Notice: To install the appliance vent adapter,please follow the appliance vent adaptermanufacturer’s instructions.Draining the CondensateCAUTION: Condensateis known to be acidic; referto local, state (provincial)or federal codes for properhandling and dischargemethods.CAUTION: Condensatemust drain away from thewater heater and shouldnot be allowed to enter thewater heater.WARNING: Failure toprovide a vent condensatedrain close to the appliancecould allow acidic flue gascondensate to enter intoappliance flueways, causingpremature failure of thewater heater.WARNING: If thecondensate collector is notused, the drain fitting mustbe capped to preventexhaust gases andcondensate from enteringthe building. The cap issupplied on the waterheater.10Provision should be made to collect anddispose of condensate from venting systems.When a water heater is vented horizontally,the vent pipe can have a DOWNWARD orUPWARD slope towards the termination. If anUPWARD slope is used, always attach a drainhose to the drain fitting and plumb the hose toa sanitary sewer drain.See Examples A and B on pages 13 and 14for DOWNWARD and UPWARD slope forhorizontally vented water heaters.When a water heater is vented ver

water heater will not function safely on LP gas and vice versa. No attempt should ever be made to convert the water heater from natural gas to LP gas. To avoid possible equipment damage, personal injury or fire, do not connect the water heater to a fuel type not in accordance with the unit data plate; propane for propane units and natural gas