Tranquility Compact (TC) SeriesSubmittal DataModels TCH/V006 - 060 60Hz - HFC-410A*LC405*LC405Rev.: January 22, 2021ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer ServiceDepartment at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merelyClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.

Table of ContentsTC Compact Packaged SeriesUnit FeaturesSelection ProcedureTC Series NomenclaturePerformance Data – ASHRAE/AHRI/ISO 13256-1Performance Data – Selection NotesPerformance Data – TC H/V 006 (PSC Blower)Performance Data – TC H/V 006 (ECM Blower)Performance Data – TC H/V 009 (PSC Blower)Performance Data – TC H/V 009 (ECM Blower)Performance Data – TC H/V 012 (PSC Blower)Performance Data – TC H/V 012 (ECM Blower)Performance Data – TC H/V 015 (PSC Blower)Performance Data – TC H/V 015 (ECM Blower)Performance Data – TC H/V 018 (PSC Blower)Performance Data – TC H/V 018 (ECM Blower)Performance Data – TC H/V 024 (PSC Blower)Performance Data – TC H/V 024 (ECM Blower)Performance Data – TC H/V 030 (PSC Blower)Performance Data – TC H/V 030 (ECM Blower)Performance Data – TC H/V 036 (PSC Blower)Performance Data – TC H/V 036 (ECM Blower)Performance Data – TC H/V 041 (PSC Blower)Performance Data – TC H/V 042 (PSC Blower)Performance Data – TC H/V 042 (ECM Blower)Performance Data – TC H/V 048 (PSC Blower)Performance Data – TC H/V 048 (ECM Blower)Performance Data – TC H/V 060 (PSC Blower)Performance Data – TC H/V 060 (ECM Blower)Performance Correction Tables for UnitsAntifreeze Correction TableBlower Performance Data – TC006Blower Performance Data – TC009Blower Performance Data – TC012Blower Performance Data – TC015Blower Performance Data – TC018Blower Performance Data – 3031323334363738394041Document page number is shown next to part number (e.g. LC405 - 3 page 3). Since not all pages are typically used inthe submittals process, the page number in the lower right corner can still be used (page of ).ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer ServiceDepartment at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merelyClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.LC405 - 2Page of

Table of ContentsTC Compact Packaged SeriesBlower Performance Data – TC030Blower Performance Data – TC036Blower Performance Data – TC041Blower Performance Data – TC042Blower Performance Data – TC048Blower Performance Data – TC060Waterside Economizer DataAirside PDWaterside Economizer Correction TablesConstant Volume ECM ControlPhysical DataTC - Horizontal – Dimensional DataTCH - with Waterside Economizer - Dimensional DataTC - Horizontal Service AccessTC - Vertical Upflow – Dimensional DataTCV - with Waterside Economizer - Dimensional DataTC - Vertical Service AccessCorner Weights for TCH Series UnitsElectrical Data – Standard UnitElectrical Data – High Static BlowerElectrical Data – Constant Torque ECMElectrical Data – Constant Volume ECMTC Series Wiring Diagram MatrixDIP Setting TableEngineering SpecificationsPerformance SheetRevision 97070728284ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer ServiceDepartment at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merelyClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.LC405 - 3Page of

Unit FeaturesTHE Tranquility 16 COMPACT(TC) SERIESUNIT FEATURESThe award winning Tranquility 16 Series raises thebar for water-source heat pump efficiencies, featuresand application flexibility. Not only does the Tranquility16 exceed ASHRAE 90.1 efficiencies, but it also usesEarthPure HFC-410A zero ozone depletion refrigerant,making it an extremely environmentally-friendly option.Tranquility 16 is eligible for LEED (Leadership in Energyand Environmental Design) points because of the “green”technology design. With one of the smallest cabinets in theindustry, the Tranquility 16 will easily fit into tight spaces.Designed to be backward compatible with thousands ofolder water-source heat pumps, the Tranquility 16 CompactSeries heat pump is packed full of the innovation you havecome to expect from the experts at ClimateMaster.Available in sizes from 1/2 ton (1.76 kW) through 5 tons(17.6 kW) with multiple cabinet options (vertical upflow andhorizontal) the Tranquility 16 offers a wide range of units formost any application.ClimateMaster’s exclusive double isolation compressormounting system makes the Tranquility 16 one of thequietest units on the market. Compressors are mountedon specially engineered sound-tested EPDM grommetsto a heavy gauge mounting plate, which is further isolatedfrom the cabinet base with rubber grommets for maximizedvibration/sound attenuation. The easy access control boxand large access panels make installing and maintaining theunit easier than other water-source heat pumps currently inproduction, proving that a small unit can be easy to service.Options such as tin-plated air coil, DDC controls, and highefficiency pleated MERV rated air filters allow customizeddesign solutions. Optional high static fan motor expands theoperating range and helps overcome some of the challengesassociated with ductwork for retrofit installations. ECMconstant CFM or constant torque motors for all sizes. Acupro-nickel water-coil and sound absorbing UltraQuietpackage are options that make a great unit even better.Optional factory installed Waterside Economizer (WSE)uses cool loop water for “free” cooling. WSE option meetsIECC section C403.3.1 and is a requirement in many states. Sizes 006 (1/2 ton, 1.76 kW) through 060 (5 tons, 17.6kW) EarthPure HFC-410A refrigerant Exceeds ASHRAE 90.1 efficiencies Galvanized steel construction Epoxy powder painted galvanized steel drain pan Sound absorbing glass fiber insulation Unique double isolation compressor mounting viavibration isolating rubber grommets for quiet operation Insulated divider and separate compressor/air handlercompartments Copeland scroll compressors (rotary for size 018 andbelow) TXV metering device Microprocessor controls standard (optional DXM2 and/orDDC controls) Field convertible discharge air arrangement for horizontalunits PSC three-speed fan motor Internally trapped condensate drain line (vertical unitsonly) Unit Performance Sentinel performance monitoringsystem Eight Safeties Standard Extended range (20 to 120 F, -6.7 to 48.9 C) capableAVAILABLE OPTIONS High static blowers LonWorks, BACnet, Modbus and Johnson N2compatibility options for DDC controls Cupro-nickel water-coil Sound absorbing UltraQuiet package Constant CFM ECM variable speed communicating motor Constant torque ECM 4 or 5 speed TAP motor Waterside Economizer (WSE) Stainless steel condensate drain pan Electrical service disconnectThe Tranquility 16 (TC) Series Water-Source Heat Pumpsare designed to meet the challenges of today’s HVACdemands with one of the most innovative products availableon the market.ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer ServiceDepartment at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merelyClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.LC405 - 4Page of

Selection ProcedureReference CalculationsHeatingCoolingLWT EWT -HEGPM x 500LWT EWT LAT EAT HCCFM x1.08LAT (DB) EAT (DB) -HRGPM x 500LC TC - SCSCCFM x1.08S/T SCTCLegend and Glossary of AbbreviationsBTUH BTU (British Thermal Unit) per hourMBTUH 1,000 BTU per hourTC total cooling capacity, BTUHSC sensible cooling capacity, BTUHS/T sensible to total cooling ratioLC latent cooling capacity, BTUHHC air heating capacity, BTUHCFM airflow, cubic feet/minuteESP external static pressure (inches w.g.)EAT entering air temperatureLAT leaving air temperature, FDB dry bulb temperature ( F)WB wet bulb temperature ( F)EWT entering water temperatureLWT leaving water temperature, FTD or delta T temperature TMWVWSEVFD water flow in U.S. gallons/minute waterside pressure drop (psi & ft. of hd.) total heat of extraction, BTUH total heat of rejection, BTUH total power unit input, kilowatts energy efficient ratio BTUH output/Watt input coefficient of performance BTUH output/BTUH input male pipe thread female pipe thread hot water generator (desuperheater) capacity, Mbtuh electronic commutated constant volume fan motor electronic commutated constant torque fan motor motorized water valve waterside economizer variable frequency driveConversion Table - to convert inch-pound (English) to S-I (Metric)Air FlowWater FlowEst Static PressureWater Pressure DropAirflow (L/s) CFM x 0.472Water Flow (L/s) gpm x 0.0631ESP (Pa) ESP (in of wg) x 249PD (kPa) PD (ft of hd) x 2.99ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer ServiceDepartment at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merelyClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.LC405 - 5Page of

Selection ProcedureStep 1 Determine the actual heating and cooling loads at thedesired dry bulb and wet bulb conditions.Step 1 Load Determination:Step 2 Obtain the following design parameters: Entering watertemperature, water flow rate in GPM, air flow in CFM,water flow pressure drop and design wet and dry bulbtemperatures. Air flow CFM should be between 300 and450 CFM per ton. Unit water pressure drop should bekept as close as possible to each other to make waterbalancing easier. Go to the appropriate tables and findthe proper indicated water flow and water temperature.Step 3 Select a unit based on total and sensible coolingconditions. Select a unit which is closest to, but no largerthan, the actual cooling load.Step 4 Enter tables at the design water flow and waterAssume we have determined that the appropriate cooling loadat the desired dry bulb 80 F and wet bulb 65 F conditions is asfollows:Total Cooling.23,700 BTUHSensible Cooling.16,500 BTUHEntering Air Temp.80 F Dry Bulb / 65 F Wet BulbStep 2 Design Conditions:Similarly, we have also obtained the following design parameters:Entering Water Temp.90 FWater Flow (Based upon 10 F rise in temp.).6.0 GPMtemperature. Read the total and sensible coolingcapacities (Note: interpolation is permissible,extrapolation is not).Air Flow.800 CFMSteps 3, 4 & 5 HP Selection:Step 5 Read the heating capacity. If it exceeds the designcriteria it is acceptable. It is quite normal for WaterSource Heat Pumps to be selected on cooling capacityonly since the heating output is usually greater than thecooling capacity.Step 6 Determine the correction factors associated withthe variable factors of dry bulb, wet bulb and airflow.Corrected Total Cooling tabulated totalcooling x wet bulb correction x air flow correctionCorrected Sensible Cooling tabulated sensible coolingx dry bulb correction x air flow correction.After making our preliminary selection (TC024), we enter thetables at design water flow and water temperature and read TotalCooling, Sens. Cooling and Heat of Rej. capacities:Total Cooling.23,400 BTUHSensible Cooling.17,500 BTUHHeat of Rejection.30,200 BTUHSteps 6 & 7 Entering Air and Airflow Corrections:Next, we determine our correction factors.TableEnt AirAir FlowCorrectedCorrected Total Cooling 23,400 x 0.9681 x 1.0050 22,767Step 7 Compare the corrected capacities to the loadrequirements. Normally if the capacities are within 10%of the loads, the equipment

14.11.2017 · Electrical Data – Constant Volume ECM 69 TC Series Wiring Diagram Matrix 70 DIP Setting Table 70 Engineering Specifications 72 Performance Sheet 82 Revision History 84 Table of Contents TC Compact Packaged Series. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without