GE LED Signage Lighting Tetra Stick — Installation Guide .

Transcription

Tetra StickInstallation Guide Fluorescent Box Sign Retrofit24VoltLED Lighting System(GETSAABBCCC71D1)**keyAABBCCCDPM PowerMax or PH PowerMax High OutputSS Single Sided or DS Double Sided018 18’’; 024 24’’; 030 30’’; 036 36’’; 042 42’’; 048 48’’; 060 60’’; 064 64’’; 072 72’’; 084 84’’; 096 96’’; 108 108’’; 117 117’’; 120 120’’A 3’ Whip Length or B 6’ Whip LengthBEFORE YOU BEGINRead these instructions completely and carefully.WARNING/AVERTISSEMENTRISK OF ELECTRIC SHOCK Turn power off before inspection, installation or removal. Properly ground Tetra power supply enclosure.RISK OF FIRE Use only UL certified wire for input/output connections.Minimum size 18 AWG (0.82mm2). Follow all NEC and local codes. Not to be submerged or used in a marine environment.RISQUES DE DÉCHARGES ÉLECTRIQUES Coupez l’alimentation avant l’inspection, l’installation ou le déplacement. Assurez-vous de correctement mettre à terre l’alimentation électrique Tetra .RISQUES D’INCENDIE N’utilisez que des fils approuvés par UL pour les entrées/sorties de connexion.Taille minimum 18 AWG (0.82mm2). Respectez tous les codes NEC et codes locaux. Ne pas submerger ou installer dans un environnement marin.CAUTION/ATTENTIONRISK OF INJURY While performing installations described, gloves, safetyglasses or goggles should be worn.RISQUE DE BLESSURE Lors de l’exécution des installations décrites, des gants, des lunettes desécurité ou des lunettes de protection doivent être portées.Save These InstructionsThis device complies with part 15 of the FCC Rules. Operationis subject to the following two conditions: (1) This device maynot cause harmful interference, and (2) this device mustaccept any interference received, including interference thatmay cause undesired operation.Use only in the manner intended by the manufacturer.If you have any questions, contact the manufacturer.Prepare Electrical WiringNote: This equipment has been tested and found to complywith the limits for a Class A digital device, pursuant to part15 of the FCC Rules. These limits are designed to providereasonable protection against harmful interference when theequipment is operated in a commercial environment. Thisequipment generates, uses, and can radiate radio frequencyenergy and, if not installed and used in accordance with theinstruction manual, may cause harmful interference to radiocommunications. Operation of this equipment in a residentialarea is likely to cause harmful interference in which case theuser will be required to correct the interference at his ownexpense.Electrical Requirements Limited to use in dry and damp locations. The grounding and bonding of the LED Driver shall be done inaccordance with National Electric Code (NEC) Article 600. Follow all National Electric Codes (NEC) and local codes. These products are only suitable for connection to a circuitfrom a Class 2 power source. These products have not beenevaluated for use when connected to a power source thatdoes not comply with Class 2 voltage and energy limitedsupplies.This Class [A] RFLD complies with the Canadian standardICES-005. Ce DEFR de la classe [A] est conforme à la NMB-005du Canada.1

Components1 UL certified 18 AWG (0.82 mm2) supply wire2 UL certified 22-14 AWG (0.33-2.08 mm2) wire connectors or22-18 AWG (0.33-0.82 mm2) inline/IDC connectors124536TC Measure PointInstallation345633125 LFL-LED Sockets LineFit Light Sockets (optional)Tetra 24 Volt Power SupplyGE Tetra StickElectrical grade RTV silicone. Examples below: Momentive RTV 6700 Series Silicone Rubber Adhesive Sealant Momentive White Blanc RTV 162 Silicone Rubber AdhesiveSealant-Electrical Grade Dow Corning 3140 - Non-Corrosive Flowable (clear) Dow Corning 3145 - Non-Corrosive Nonflowable (clear or gray) Dow Corning RTV 748 Non-Corrosive Sealant-WhitePrior to installation, survey the site for information regarding power and accessibility inside and outside the building. Ensure that thebranch circuit supplying the existing transformer or ballast will be within the voltage ratings of the new LED power supply, and havea current rating not exceeding 20A, or that permitted by applicable local, state, or country electrical codes (whichever is less).If removal of the existing lighting equipment (see Step 2) eliminates the disconnect switch, as required by applicable local, state, orcountry electrical codes; a new disconnect switch must be installed.If required, the disconnect switch shall be installed by qualified personnel, in accordance with applicable local, state, and countryelectrical codes.Make sure the removal of lighting equipment does not compromise the integrity of the sign body (i.e. water intrusion). Fill in all holes0.5 in. (13 mm) or smaller with the appropriate amount of rated caulk or sealant. For holes greater than 0.5 in. (13 mm), use analuminum or zinc coated steel patch with rivets and sealant.Old Fluorescent tubeRemove oldcomponentsF48T12HOor F48T8HOTetra Stick1Turn off power and remove panelfrom fluorescent box sign.LEDs facefront of sign42Remove old fluorescent tubes, ballastand wiring. DO NOT remove existingfluorescent lamp holders. Inspectexisting sockets and replace asneeded. De-energize the lamp holders.NOTE: Follow all federal and localregulations when disposing ofneon tubing, fluorescent tubes,transformers and ballasts.Read the product labels to determineTetra Stick length required to spanwidth of sign based on table in theSpecifications section (pages 4-5).See Note about supportExisting socket shouldbe push-in doublecontact lamp holderOrient Tetra Stick so LEDs are facingfront of sign.3GETSAABBCCC71-6-15Push Tetra Stick into existingfluorescent lamp holders.26Continue installing Tetra Stick fixtures.NOTE: For horizontal installationsgreater than 6ft in length, the TetraStick(s) should be centrally supported.

Electrical ConnectionsSingle Tetra Stick InstallationRed ( )Black or blue (-)Black (-)Red ( )Power Supply1To Tetra SticksPower supplyConnect the red wire ( ) of the Tetra Stick to the red wire ( ) of the power supply. Connect the black wire (-) of the Tetra Stick to theblack or blue wire (-) of the power supply. Seal all connections that could be exposed to water with electrical grade RTV siliconeMutiple Tetra Stick InstallationRed ( ) 3Power supply2Add up total number of Tetra Sticks to determine theappropriate number of 24VDC Class 2 Tetra LED driversto use based on the Specifications Charts for Tetra Stickchosen (see pages 4-5).AC lineBlack (-)Red ( ) 1Black or blue (-)To Tetra SticksConnect the red wire ( ) of the Tetra Stick to the red wire ( )of the power supply. Connect the black wire (-) of theTetra Stick to the black or blue wire (-) of the power supply.GEPS24-180Connect Tetra Stick using twist-on wire connectors or in-line (IDC) connectors. Join black wires together and red wires together.Seal all connections that could be exposed to water with electrical grade RTV silicone.NOTE: Make sure not to exceed LED driver power limits (see Step 1). Drawing above is for reference only; your lighting layout may differ.NOTE: All drivers except GEPS24-180U must be enclosed or provided with a GEPSJB60 LED driver extended enclosure.NOTE: Refer to Power Supply Installation Guide for AC driver installation.3

Specifications – Single Sided PowerMAXWattsper StickSticks per80WPowerSupplySticks per100WPowerSupplyTotal (per Bank)Total (per Bank)15.911.7384786(43)141(47)GETSPMSS01871A1 / 71A1 / 3071A1 / 3671A1 / 4271A1 / 4871A1 / 6071A1 / 6471A1 / 271A1 / 71A1 / 1A1 / 871A1 / 771A1 / 071A1 / ticks per180WPower SupplySticks per300WPower SupplyPart Number(A-3 foot whip / B-6 foot whip)Specifications – Double Sided PowerMAXWattsper StickSticks per80WPowerSupplySticks per100WPowerSupplyTotal (per Bank)Total (per Bank)15.913.40192442(21)72(24)GETSPMDS01871A1 / 02471A1 / 03071A1 / 3671A1 / 271A1 / 71A1 / 71A1 / 71A1 / 71A1 / 1A1 / cks per180W PowerSupplySticks per300WPower SupplyPart Number(A-3 foot whip / B-6 foot whip)9693.9120.20348(4)12(4)GETSPMDS09671A1 / 871A1 / 71A1 / 71A1 / GETSPMDS12071B14

Specifications – Single Sided PowerMAX HOWattsper StickSticks per80WPowerSupplySticks per100WPowerSupplyTotal (per Bank)Total (per Bank)15.912.40263358(29)99(33)GETSPHSS01871A1 / 02471A1 / 03071A1 / 03671A1 / 04271A1 / 4871A1 / 1A1 / 1A1 / 71A1 / 71A1 / 71A1 / cks per180WPower SupplySticks per300WPower SupplyPart Number(A-3 foot whip / B-6 foot whip)108105.9115.604510(5)15(5)GETSPHSS10871A1 / 771A1 / 071A1 / GETSPHSS12071B1Specifications – Double Sided PowerMAX HOWattsper StickSticks per80WPowerSupplySticks per100WPowerSupplySticks per180WPower SupplySticks per300WPower SupplyTotal (per Bank)Total (per Bank)15.914.8131630(15)48(16)GETSPHDS01871A1 / 471A1 / 071A1 / A1 / 1A1 / 1A1 / A1 / A1 / A1 / A1 / 1 / t Number(A-3 foot whip / B-6 foot whip)108105.9131.2224(2)9(3)GETSPHDS10871A1 / 1A1 / 1A1 / GETSPHDS12071B15

Power Supply SpecificationsWattagePower SupplyLong DescriptionGEPS24D-80UPower Supply (24VDC / 96W), Input Voltage: 108-305VAC;Damp Rated; Self-Contained, Remote or Raceway;1 Output Bank; Class 2GEPS24W-80Power Supply (24VDC/180W), Input Voltage: 90-305VAC;Damp Rated; Self-Contained, Remote or Raceway;2 Output Banks of 90W each; Class wer Supply (24VDC / 96W), Input Voltage: 108-305VAC;Damp Rated; Self-Contained, Remote or Raceway;1 Output Bank; Class 2180WGEPS24-180UPower Supply (24VDC/96W), Input Voltage: 108-305VAC;Damp Rated; 1 Output Bank; Class 2300WGEPS24-300U-GL0-10V Dimming Power Supply (24VDC/80W), Input Voltage: 90-305VAC;Damp Rated; Self-Contained, Remote or Raceway;1 Output Bank; Class 280WTroubleshootingSymptomSolutionRow of fixtures does not lightSign does not lightIndividual fixture does not light Check wire connections to power supply to ensure red stripe-to-red and white-to-black connections.Check row-to-row polarity connections.Check input and output voltage and check power supply input/output connections.Check polarity connections.Remove fixture and replace with another working fixture.This product is intended solely for the use of non-residential signage lighting and is not intended for use in any other applications.Conforms to the following standards:IIIAll trademarks are the property of their respective owners. Information provided is subject tochange without notice. All values are design or typical values when measured under laboratoryconditions. Current, powered by GE is a business of the General Electric Company. 2018 GE.www.currentbyge.comSIGN220 (Rev 10/03/18)

33125 LFL-LED Sockets LineFit Light Sockets (optional) Tetra 24 Volt Power Supply GE Tetra Stick Electrical grade RTV silicone. Examples below: Momentive RTV 6700 Series Silicone Rubber Adhesive Sealant Momentive White Blanc RTV 162 Silicone Rubber Adhesive Sealant-Electrical Grade Dow Corning 3140 - Non-Corrosive Flowable (clear) Dow Corning 3145 - Non-Corrosive .