PM02 01 0033 ASC Flex EN 2020-09-02 V2 - Schmidtdental

Transcription

MPSMULTI PLATFORM SYSTEMSThe new flexibility Titanium base ASC Flex

Titanium base ASC Flex –guarantees maximum flexibilityThe titanium base for angled screwchannels has been especially developedfor demanding prosthetic cases. Forunfavorably positioned implants oresthetically demanding cases, it is nowpossible to move the screw channelin an oral direction, or to customizethe chimney in four different lengthsdepending on the patient's needs.2

Titanium base ASC Flex – CompatibilityManufacturerImplant systemcompatible withBEGO Implant SystemsSemados * SC/SCX/RS/RSX/RIBS-SeriesSemados * S/RIBS-SeriesTapered InternalR-SeriesTapered Internal PlusR-SeriesTapered Tissue LevelR-SeriesCertain *H-SeriesExternal HexI-SeriesBredent MedicalSKY *B-SeriesCamlogCamlog *C-SeriesConelog antium IIDT-SeriesANKYLOS * C/XY-SeriesBioHorizonsBIOMET 3i DentiumDENTSPLY SIRONA ASTRA TECH OsseoSpeed EVEV-SeriesASTRA TECH OsseoSpeed * TXS-SeriesXiVE * ST-SeriesHiOssen Implant *ET SystemOT-SeriesMedentika ProconeC-SeriesMedentis MedicalICXCX-SeriesMISSEVEN Internal HexR-SeriesNobel BiocareBrånemark System *K-SeriesNobelActive *F-SeriesNobelReplace * ConicalF-SeriesNobelReplace * TaperedE-SeriesOSSTEM ImplantsTS SystemOT-SeriesStraumannBone LevelL-SeriesTissue LevelN-SeriesA ImplantOT-Series T-Plus Implant TechST ImplantZimmer DentalOT-SeriesTapered Screw-Vent **is a registered trademark of an independent third party R-Series3

Titanium base ASC Flex –The original fromMedentika One designMedentika PIONEERTITANIUM BASE4

Latest generationASC Flex1st generation2nd generationThe pioneer:The evolution:The state-of-the-art:The first titanium baseon the market fromMedentika two different chimney heights angled screw channel 4 possible chimney heights optimized bonding interface optimized, slimmer emergenceprofile adapted emergence profilecompatible with all major implant systems5

Titanium baseASC Flex6.5 mm5.5 mm4.5 mm3.5 mmVARIABLECHIMNEY HEIGHTWhile the chimney height of 6.5 mmalso supports high restorations, it canbe shortened in individual cases to5.5/4.5/3.5 mm, reducing the verticaldistance for perfect adaptation to theclinical situation.OPTIMIZEDEMERGENCE PROFILEThe optimized emergence profilesupports and protects the softtissue.6Digital libraries are available forthe following manufacturers*:

SCREW CHANNELThe titanium base can be usedwith either the angled or thestraight screw channel.Thanks to the high chimneyheight, the titanium base offersvery good support for the restoration.INTERNALROTATION LOCKThe internal rotation lock receives allthe material strength of the restoration, effectively avoiding predetermined breaking points. At the sametime it secures the precise positioning of the hybrid abutment crownduring bonding.BIO-PLATFORM DESIGNSlightly tapered platform to hold thefixing material, thereby reducing thebonding gap in the transitional areato the gingiva.* to some extent this depends on the availability of the updates of the specificmanufacturer.7

NEWTitanium base ASC FlexPlatform switch and GH 2.5 mmGINGIVAL HEIGHTthe additional gingival height is 2.5 mm2.5 mmOPTIMIZED EMERGENCE PROFILEPLATFORM SWITCHING DESIGNThe optimized, even slimmer emergence profile witha gingival height of 2.5 mm supports and protects thesoft tissue. Available for conical implant-abutmentconnectionsThe platform switch design for the Camlog * andProcone implant-abutment connection is used tosupport the hard and soft tissues.With conical implant systems, the platform switcheffect is produced by the design of the implantabutment connection.* is a registered trademark of an independent third party8Digital libraries are available forthe following manufacturers**:

Titanium base ASC Flexrotating for bridgesROTATINGWithout indexing in the implantabutment connectionNEWNow also for multi-unit bridge restorations inesthetically demanding situations.The screw channel can be located in the non-estheticarea. But the rotating titanium base ASC Flex can alsobe used for a bridge restoration with a straight screwchannel.** to some extent this depends on the availability of the updates of the specific manufacturer.9

Angled screwchannelThe Ball-Torx placement instrumentallows angulation of up to 25 .25 MAXThe maximum achievable angulation essentially depends on therespective implant bond and the abutment screw.The angled screw channel means that the opening can be movedto areas that are less relevant in esthetic and functional respects.Accessibility can also be increased in cases where space is limiteddue to antagonists.Varying angulationsCompatibilitySeriesChimneyImplant connectionAngulation ofheight ofof titanium basetitanium basetitanium baseBredent Medical / SKY *B-SeriesNP3.5-6.5 mm20 Camlog / Camlog *C-SeriesD 3.3 - D 4.33.5-6.5 mm24 D 5.03.5-6.5 mm18 D 3.3 - D 4.33.5-6.5 mm24 D 5.03.5-6.5 mm18 Medentika / ProconeDentium / SuperLine,Implantium / Implantium IIDT-Series D 3.6-7.0 mm3.5-65 mm20 Nobel Biocare / NobelActive * /NobelReplace * ConicalF-SeriesRP 4.3/5.03.5-6.5 mm20 Straumann / Tissue LevelN-SeriesNNC 3.53.5-6.5 mm20 Angulations of up to 25 are possible with all other series and implant connections.10

Ball-Torx placementinstrumentAll titanium bases ASC Flex are screwed in withthe Ball-Torx placement instrument (M 03-8,M 10-8 or 6-13-06), guaranteeing reliable forcetransfer.NEWContra-angledhandpieceM 03-8Manual and ratchetM 10-8Contra-angledhandpiece6-13-0611

Alignment of thescrew channelAs a rule, the screw channel is alwaysangled in the direction of thescanbody flat (SF).With implant systems that only allow four or fewer positioning options betweenabutment and implant, a second titanium base variant that is angled over the cornerof the scanbody (SC) is available. This ensures greater flexibility in aligning the screwchannel in the desired direction.Overview of the second variantCamlogCamlog *compatible withC-SeriesMedentika ProconeCamlogConelog *compatible withD-SeriesNobel BiocareNobelReplace * Taperedcompatible withE-SeriesStraumannBone Levelcompatible withL-SeriesStraumannSoft Tissue Levelcompatible withN-SeriesIn this case, the opening of the titanium base (angulation of the screwchannel) points towards the corner of the scanbody (SC).12*is a registered trademark of an independent third party

SELECTION VIA THE SCANBODY:With implant systems that only allow four or fewer positioning options between abutment andimplant, a second titanium base variant that is angled over the corner of the scanbody (SC) isavailable. This ensures greater flexibility in aligning the screw channel in the desired direction.Example:Type SF (Scanbody Flat):Titanium base C 1600-1-SF / screw channel angled over the flat of the scanbody.Type SC (Scanbody Corner):Titanium base C 1600-1-SC / screw channel angled over the right corner of the scanbody.Type SFType SCSELECTION VIA THE IMPLANT CONNECTION:An alternative to the alignment of the angled screw channel via the scanbody is alignment viathe type1/type2 implant connection.Example:Type 1: over the flat of the implant connectionType 2: over the corner/cam of the implant connectionType 1Type 213

Positioning in the CAD softwareSituation:The scanbody was positioned and scanned with the flat side facing the lips. This would be the side that thesoftware would use for the screw channel.Situation:The scanbody was positioned and scanned with the flat side facing the lips. This would be the side that thesoftware would use for the screw channel.Situation:The scanbody was positioned and scanned with the flat side facing the lips. This would be the side that thesoftware would use for the screw channel.14

You can also find detailed videos on our website:www.medentika.comWorkaround:Since the 2020 version of the Dental System wasintroduced, it is now possible to rotate the titaniumbase on its own axis, dispensing with the need for anew scan.Workaround:Since the Plovdiv version was introduced, it is nowpossible to rotate the titanium base on its own axis,dispensing with the need for a new scan.Workaround:Since the 13.2 version was introduced, it is nowpossible to rotate the titanium base on its own axis,dispensing with the need for a new scan.New side for the screw channel angulation:Thanks to the rotation, the side can be redefined forthe screw channel. The rotation option depends onthe respective implant connection.New side for the screw channel angulation:Thanks to the rotation, the side can be redefined forthe screw channel. The rotation option depends onthe respective implant connection.New side for the screw channel angulation:Thanks to the rotation, the side can be redefined forthe screw channel. The rotation option depends onthe respective implant connection.15

16

ASC Flex modeling capsThe ASC Flex modeling cap sets aredesigned to aid the conventional dentalworkflow.They facilitate simple and fast modeling ofrestorations on ASC Flex titanium bases,taking into account the desired chimneyheight and screw channel.The ASC Flex modeling cap sets aredesigned for use with various platformsof the ASC Flex titanium bases.17

ASC Flex modeling caps –Product properties20 MINIMUM WALL THICKNESSThe minimum wall thickness of 0.6 mm,in the area of the titanium base chimney,guarantees the required stability and issuitable for popular press-on ceramicmaterials.0,6 mm18

FRICTION-FITThe modeling cap is secured on thetitanium base in a slight friction-fit bythree lugs. This facilitates handlingduring modeling.PREFABRICATED SHOULDERThe shoulder of the modeling cap,which is designed for simple andprecise modeling, ensures a perfecttransition to the titanium base.19

ASC Flex modeling caps –Product propertiesIDENTIFICATIONSafe and unambiguous allocation by marking with1 chimney height2 article number12VARIANTSTwo basic variants of the modeling cap are available:straight and angled at 20 20

The overall height of the modeling cap is 15 mm, leavingspace for a screw channel that is long enough even for highrestorations. The modeling cap can be adapted individually tothe required prosthetic situation by trimming or grinding.15 mmCHIMNEY HEIGHTThe ASC Flex modeling caps are supplied as a set.The set includes all 4 chimney heights:3.5 / 4.5 / 5.5 / 6.5 mm.Straight and angled sets are available.MATERIALThe ASC Flex modeling cap is made of a plastic that leavesno residue when burnt.21

ASC Flex modeling caps –Available setsSTRAIGHT SETstraight screw channel infour chimney heights3.54.55.56.5(chimney height)ANGLED SETangled screw channel 20 infour chimney heights3.54.55.56.5(chimney height)Available sets:Each modeling cap set consists of 4 modeling caps in 4 differentchimney heights.The set is available in 2 variants: straight or angled 20 .For the allocation and article number of the set matching therelevant ASC Flex titanium base, please see the correspondingASC Flex titanium base product group.22

Medentika Titanium base ASC FlexProduct overview23

B-SeriesBredent Medical SKY *Titanium base ASC Flex angled screw channel Titanium Grade 5 CF incl. abutment screw Type SF Screw channel angled overthe flat of the scanbody Type Recommended torque: 25 NcmType 1Type SFImplant connectionNPChimney height3,5-6,5Gingiva height0,35 mmArticle No. Type 1/SFB 1600-1-SFAbutment screwB 62Please note:To screw in the titanium base ASC Flex you need the Placement instrument Ball-TorxM 03-8, M 10-8 or 6-13-06. To select the desired direction of the angled screw channel,please consider the Instruction for use.Modelling cap set burn-out plastic Scope of Delivery: four chimneyheightsModelling capset straightModelling capset angled6-09-016-09-02as of Dec.Titanium base ASC Flexrotating angled screw channel Titanium Grade 5 CF incl. abutment screw Recommended torque: 25 NcmImplant connectionNPChimney height3,5-6,5Gingiva height0,35 mmArticle No.B 1800Abutment screwB 62Please note:To screw in the titanium base ASC Flex you need the Placement instrument Ball-Torx M03-8, M 10-8 or 6-13-06.Modelling cap set burn-out plastic Scope of Delivery: four chimneyheightsModelling capset straightModelling capset angled24*is a registered trademark of an independent third party6-09-016-09-02

BS-SeriesBEGO Implant Systems Semados * S/SC/SCX/RS/RSX/RITitanium base ASC Flex angled screw channel Titanium Grade 5 CF incl. abutment screw Type SF Screw channel angled overthe flat of the scanbody Type Recommended torque: 30 NcmType 1Type SFImplant connectionD 3,25/3,75-PSD 4,1-PSD 4,5-PSD 5,5-PSChimney height3,5-6,53,5-6,53,5-6,53,5-6,5Gingiva height0,6 mm0,45 mm0,15 mm0,3 mmArticle No. Type 1/SFBS 1600-1-SFBS 1610-1-SFBS 1620-1-SFBS 1630-1-SFAbutment screwBS 61BS 61BS 61BS 61Please note:To screw in the titanium base ASC Flex you need the Placement instrument Ball-TorxM 03-8, M 10-8 or 6-13-06. To select the desired direction of the angled screw channel,please consider the Instruction for use.Modelling cap set burn-out plastic Scope of Delivery: four chimneyheightsModelling capset straightModelling capset 09-106-09-38as of Dec.Titanium base ASC Flexrotating angled screw channel Titanium Grade 5 CF incl. abutment screw Recommended torque: 30 NcmImplant connectionD 3,25/3,75-PSD 4,1-PSD 4,5-PSD 5,5-PSChimney height3,5-6,53,5-6,53,5-6,53,5-6,5Gingiva height0,6 mm0,45 mm0,15 mm0,3 mmArticle No.BS 1800BS 1810BS 1820BS 1830Abutment screwBS 61BS 61BS 61BS 61Please note:To screw in the titanium base ASC Flex you need the Placement instrument Ball-Torx M03-8, M 10-8 or 6-13-06.Modelling cap set burn-out plastic Scope of Delivery: four chimneyheightsModelling capset straightModelling capset angled*is a registered trademark of an independent third 9-106-09-3825

C-SeriesCamlog * Camlog *Medentika ProconeTitanium base ASC Flex angled screw channel Titanium Grade 5 CF incl. abutment screw Type SC Screw channel angled overthe right corner of the scanbody Type SF Screw channel angled overthe flat of the scanbody Type Recommended torque: 20 NcmType 1Type SCType 2Type SFImplant connectionD 3,3D 3,8D 4,3D 5,0Chimney height3,5-6,53,5-6,53,5-6,53,5-6,5Gingiva height0,35 mm0,35 mm0,35 mm0,35 mmArticle No. Type 1/SCC 1600-1-SCC 1610-1-SCC 1620-1-SCC 1630-1-SCArticle No. Type 2/SFC 1600-2-SFC 1610-2-SFC 1620-2-SFC 1630-2-SFAbutment screwC 67C 67C 67C 68Please note:To screw in the titanium base ASC Flex you need the Placement instrument Ball-TorxM 03-8, M 10-8 or 6-13-06. To select the desired direction of the angled screw channel,please consider the Instruction for use.Modelling cap set burn-out plastic Scope of Delivery: four chimneyheightsModelling capset straightModelling capset 09-086-09-32NEWTitanium base ASC FlexPlatform switch angled screw channel Titanium Grade 5 CF incl. abutment screw Type SC Screw channel angled overthe right corner of the scanbody Type SF Screw channel angled overthe flat of the scanbody Type Recommended torque: 20 NcmType 1Type SCType 2Type SFImplant connectionD 3,8D 4,3D 5,0Chimney height3,5-6,53,5-6,53,5-6,5Gingiva height1,0 mm1,0 mm1,0 mmArticle No. Type 1/SCC 1610P-1-SCC 1620P-1-SCC 1630P-1-SCArticle No. Type 2/SFC 1610P-2-SFC 1620P-2-SFC 1630P-2-SFAbutment screwC 67C 67C 68Please note:To screw in the titanium base ASC Flex you need the Placement instrument Ball-TorxM 03-8, M 10-8 or 6-13-06. To select the desired direction of the angled screw channel,please consider the Instruction for use.Modelling cap set burn-out plastic Scope of Delivery: four chimneyheightsModelling capset straightModelling capset angled26*is a registered trademark of an independent third party6-09-016-09-016-09-276-09-026-09-026-09-28

C-SeriesCamlog * Camlog *Medentika ProconeNEWTitanium base ASC Flexrotating angled screw channel Titanium Grade 5 CF incl. abutment screw Recommended torque: 20 NcmImplant connectionD 3,3D 3,8D 4,3D 5,0Chimney height3,5-6,53,5-6,53,5-6,53,5-6,5Gingiva height0,35 mm0,35 mm0,35 mm0,35 mmArticle No.C 1800C 1810C 1820C 1830Abutment screwC 67C 67C 67C 68Please note:To screw in the titanium base ASC Flex you need the Placement instrument Ball-Torx M03-8, M 10-8 or 6-13-06.Modelling cap set burn-out plastic Scope of Delivery: four chimneyheightsModelling capset straightModelling capset angled*is a registered trademark of an independent third 9-086-09-3227

CX-SeriesMedentis Medical ICXTitanium base ASC FlexNEW angled screw channel Titanium Grade 5 CF incl. abutment screw Type SF Screw channel angled overthe flat of the scanbody Type Recommended torque: 30 NcmType 1Type SFImplant connectionD 3,75-4,8D 3,75-4,8Chimney height3,5-6,53,5-6,5Gingiva height1,1 mm2,5 mmArticle No. Type 1/SFCX 1600-1-SFCX 1700-1-SFAbutment screwCX 61CX 61Please note:To screw in the titanium base ASC Flex you need the Placement instrument Ball-TorxM 03-8, M 10-8 or 6-13-06. To select the desired direction of the angled screw channel,please consider the Instruction for use.Modelling cap set burn-out plastic Scope of Delivery: four chimneyheightsModelling capset straightModelling capset angled6-09-096-09-096-09-106-09-10as of Dec.Titanium base ASC Flexrotating angled screw channel Titanium Grade 5 CF incl. abutment screw Recommended torque: 30 NcmImplant connectionD 3,75-4,8Chimney height3,5-6,5Gingiva height1,1 mmArticle No.CX 1800Abutment screwCX 61Please note:To screw in the titanium base ASC Flex you need the Placement instrument Ball-Torx M03-8, M 10-8 or 6-13-06.Modelling cap set burn-out plastic Scope of Delivery: four chimneyheightsModelling capset straightModelling capset angled286-09-096-09-10

D-SeriesCamlog Conelog *Titanium base ASC FlexNEWas of Dec.as of Dec. angled screw channel Titanium Grade 5 CF incl. abutment screw Type SC Screw channel angled overthe right corner of the scanbody Type SF Screw channel angled overthe flat of the scanbody Type Recommended torque: 20 NcmType 1Type SCType 2Type SFImplant connectionD 3,3D 3,3D 3,8/4,3D 3,8/4,3Chimney height3,5-6,53,5-6,53,5-6,53,5-6,5Gingiva height1,0 mm2,5 mm1,0 mm2,5 mmArticle No. Type 1/SCD 1600-1-SCD 1700-1-SCD 1610-1-SCD 1710-1-SCArticle No. Type 2/SFD 1600-2-SFD 1700-2-SFD 1610-2-SFD 1710-2-SFAbutment screwD 62D 63D 62D 63Please note:To screw in the titanium base ASC Flex you need the Placement instrument Ball-TorxM 03-8, M 10-8 or 6-13-06. To select the desired direction of the angled screw channel,please consider the Instruction for use.Modelling cap set burn-out plastic Scope of Delivery: four chimneyheightsModelling capset straightModelling capset 09-026-09-02as of Dec.Titanium base ASC Flexrotating angled screw channel Titanium Grade 5 CF incl. abutment screw Recommended torque: 20 NcmImplant connectionD 3,3D 3,8/4,3Chimney height3,5-6,53,5-6,5Gingiva height1,0 mm1,0 mmArticle No.D 1800D 1810Abutment screwD 62D 62Please note:To screw in the titanium base ASC Flex you need the Placement instrument Ball-Torx M03-8, M 10-8 or 6-13-06.Modelling cap set burn-out plastic Scope of Delivery: four chimneyheightsModelling capset straightModelling capset angled*is a registered trademark of an independent third party6-09-016-09-016-09-026-09-0229

DT-SeriesDentium SuperLine, Implantium, Implantium IITitanium base ASC Flexas of Dec. angled screw channel Titanium Grade 5 CF incl. abutment screw Type SF Screw channel angled overthe flat of the scanbody Type Recommended torque: 25 NcmType 1Type SFImplant connectionD 3,6-7,0D 3,6-7,0Chimney height3,5-6,53,5-6,5Gingiva height1,0 mm2,5 mmArticle No. Type 1/SFDT 1600-1-SFDT 1700-1-SFAbutment screwDT 61DT 61Please note:To screw in the titanium base ASC Flex you need the Placement instrument Ball-TorxM 03-8, M 10-8 or 6-13-06. To select the desired direction of the angled screw channel,please consider the Instruction for use.Modelling cap set burn-out plastic Scope of Delivery: four chimneyheightsModelling capset straightModelling capset angled6-09-116-09-116-09-126-09-12as of Dec.Titanium base ASC Flexrotating angled screw channel Titanium Grade 5 CF incl. abutment screw Recommended torque: 25 NcmImplant connectionD 3,6-7,0Chimney height3,5-6,5Gingiva height1,0 mmArticle No.DT 1800Abutment screwDT 61Please note:To screw in the titanium base ASC Flex you need the Placement instrument Ball-Torx M03-8, M 10-8 or 6-13-06.Modelling cap set burn-out plastic Scope of Delivery: four chimneyheightsModelling capset straightModelling capset angled306-09-116-09-12

E-SeriesNobel Biocare NobelReplace * TaperedTitanium base ASC Flex angled screw channel Titanium Grade 5 CF incl. abutment screw Type SF Screw channel angled overthe flat of the scanbody Type Type SC Screw channel angled overthe right corner of the scanbody Recommended torque: 35 NcmType 1Type SFType 2Type SCImplant connectionNP 3,5RP 4,3WP 5,0Chimney height3,5-6,53,5-6,53,5-6,5Gingiva height0,35 mm0,35 mm0,35 mmArticle No. Type 1/SFE 1600-1-SFE 1610-1-SFE 1620-1-SFArticle No. Type 2/SCE 1600-2-SCE 1610-2-SCE 1620-2-SCAbutment screwE 68E 69E 69Please note:To screw in the titanium base ASC Flex you need the Placement instrument Ball-TorxM 03-8, M 10-8 or 6-13-06. To select the desired direction of the angled screw channel,please consider the Instruction for use.Modelling cap set burn-out plastic Scope of Delivery: four chimneyheightsModelling capset straightModelling capset angled6-09-016-09-276-09-336-09-026-09-286-09-34as of Dec.Titanium base ASC Flexrotating angled screw channel Titanium Grade 5 CF incl. abutment screw Recommended torque: 35 NcmImplant connectionNP 3,5RP 4,3WP 5,0Chimney height3,5-6,53,5-6,53,5-6,5Gingiva height0,35 mm0,35 mm0,35 mmArticle No.E 1800E 1810E 1820Abutment screwE 68E 69E 69Please note:To screw in the titanium base ASC Flex you need the Placement instrument Ball-Torx M03-8, M 10-8 or 6-13-06.Modelling cap set burn-out plastic Scope of Delivery: four chimneyheightsModelling capset straightModelling capset angled*is a registered trademark of an independent third party6-09-016-09-276-09-336-09-026-09-286-09-3431

EV-SeriesDENTSPLY SIRONA ASTRA TECH OsseoSpeed * EVTitanium base ASC FlexNEWNEW angled screw channel Titanium Grade 5 CF incl. abutment screw Type SF Screw channel angled overthe flat of the scanbody Type Recommended torque: 25 NcmType 2Type SFImplant connectionD 3,0D 3,0D 3,6D 3,6Chimney height3,5-6,53,5-6,53,5-6,53,5-6,5Gingiva height1,15 mm2,5 mm1,15 mm2,5 mmArticle No. Type 2/SFEV 1600-2-SFEV 1700-2-SFEV 1610-2-SFEV 1710-2-SFAbutment screwEV 70EV 600EV 67EV 601Please note:To screw in the titanium base ASC Flex you need the Placement instrument Ball-TorxM 03-8, M 10-8 or 6-13-06. To select the desired direction of the angled screw channel,please consider the Instruction for use.Modelling cap set burn-out plastic Scope of Delivery: four chimneyheightsModelling capset straightModelling capset 09-046-09-04Titanium base ASC FlexNEWNEW angled screw channel Titanium Grade 5 CF incl. abutment screw Type SF Screw channel angled overthe flat of the scanbody Type Recommended torque: 25 NcmType 2Type SFImplant connectionD 4,2D 4,2D 4,8D 4,8Chimney height3,5-6,53,5-6,53,5-6,53,5-6,5Gingiva height1,15 mm2,5 mm1,15 mm2,5 mmArticle No. Type 2/SFEV 1620-2-SFEV 1720-2-SFEV 1630-2-SFEV 1730-2-SFAbutment screwEV 68EV 68EV 69EV 69Please note:To screw in the titanium base ASC Flex you need the Placement instrument Ball-TorxM 03-8, M 10-8 or 6-13-06. To select the desired direction of the angled screw channel,please consider the Instruction for use.Modelling cap set burn-out plastic Scope of Delivery: four chimneyheightsModelling capset straightModelling capset angled32*is a registered trademark of an independent third 9-306-09-30

EV-SeriesDENTSPLY SIRONA ASTRA TECH OsseoSpeed * EVTitanium base ASC FlexNEW angled screw channel Titanium Grade 5 CF incl. abutment screw Type SF Screw channel angled overthe flat of the scanbody Type Recommended torque: 25 NcmType 2Type SFImplant connectionD 5,4D 5,4Chimney height3,5-6,53,5-6,5Gingiva height1,15 mm2,5 mmArticle No. Type 2/SFEV 1640-2-SFEV 1740-2-SFAbutment screwEV 69EV 69Please note:To screw in the titanium base ASC Flex you need the Placement instrument Ball-TorxM 03-8, M 10-8 or 6-13-06. To select the desired direction of the angled screw channel,please consider the Instruction for use.Modelling cap set burn-out plastic Scope of Delivery: four chimneyheightsModelling capset straightModelling capset angled6-09-356-09-356-09-366-09-36NEWTitanium base ASC Flexrotating angled screw channel Titanium Grade 5 CF incl. abutment screw Recommended torque: 25 NcmImplant connectionD 3,0D 3,6D 4,2D 4,8D 5,4Chimney height3,5-6,53,5-6,53,5-6,53,5-6,53,5-6,5Gingiva height1,15 mm1,15 mm1,15 mm1,15 mm1,15 mmArticle No.EV 1800EV 1810EV 1820EV 1830EV 1840Abutment screwEV 70EV 67EV 68EV 69EV 69Please note:To screw in the titanium base ASC Flex you need the Placement instrument Ball-TorxM 03-8, M 10-8 or 6-13-06. To select the desired direction of the angled screw channel,please consider the Instruction for use.Modelling cap set burn-out plastic Scope of Delivery: four chimneyheightsModelling capset straightModelling capset angled*is a registered trademark of an independent third 9-046-09-146-09-306-09-3633

F-SeriesNobel Biocare NobelActive * NobelReplace *ConicalTitanium base ASC FlexNEWNEW angled screw channel Titanium Grade 5 CF incl. abutment screw Type SF Screw channel angled overthe flat of the scanbody Type Recommended torque:15 Ncm: D 3,035 Ncm: NP 3,5Type 1Type SFImplant connectionD 3,0D 3,0NP 3,5NP 3,5Chimney height3,5-6,53,5-6,53,5-6,53,5-6,5Gingiva height1,0 mm2,5 mm1,0 mm2,5 mmArticle No. Type 1/SFF 1620-1-SFF 1720-1-SFF 1600-1-SFF 1700-1-SFAbutment screwF 69F 602F 67F 67Please note:To screw in the titanium base ASC Flex you need the Placement instrument Ball-TorxM 03-8, M 10-8 or 6-13-06. To select the desired direction of the angled screw channel,please consider the Instruction for use.Modelling cap set burn-out plastic Scope of Delivery: four chimneyheightsModelling capset straightModelling capset 09-026-09-02Titanium base ASC FlexNEW angled screw channel Titanium Grade 5 CF incl. abutment screw Type SF Screw channel angled overthe flat of the scanbody Type Recommended torque:35 Ncm: RP 4,3/5,0Type 1Type SFImplant connectionRP 4,3/5,0RP 4,3/5,0Chimney height3,5-6,53,5-6,5Gingiva height1,0 mm2,5 mmArticle No. Type 1/SFF 1610-1-SFF 1710-1-SFAbutment screwF 68F 68Please note:To screw in the titanium base ASC Flex you need the Placement instrument Ball-TorxM 03-8, M 10-8 or 6-13-06. To select the desired direction of the angled screw channel,please consider the Instruction for use.Modelling cap set burn-out plastic Scope of Delivery: four chimneyheightsModelling capset straightModelling capset angled34*is a registered trademark of an independent third party6-09-116-09-116-09-126-09-12

F-SeriesNobel Biocare NobelActive * NobelReplace *Conicalas of Dec.Titanium base ASC Flexrotating angled screw channel Titanium Grade 5 CF incl. abutment screw Recommended torque:15 Ncm: D 3,035 Ncm: NP 3,535 Ncm: RP 4,3/5,0Implant connectionD 3,0NP 3,5RP 4,3/5,0Chimney height3,5-6,53,5-6,53,5-6,5Gingiva height1,0 mm1,0 mm1,0 mmArticle No. Type 1/SFF 1820F 1800F 1810Abutment screwF 69F 67F 68Bitte beachten:Zum Eindrehen der Titanbasis ASC Flex benötigen Sie das Eindrehinstrument Kugel-Torx M 03-8, M 10-8 oder 6-13-06.Modelling cap set burn-out plastic Scope of Delivery: four chimneyheightsModelling capset straightModelling capset angled*is a registered trademark of an independent third party6-09-016-09-016-09-116-09-026-09-026-09-1235

H-SeriesBIOMET 3i Certain *Titanium base ASC Flex angled screw channel Titanium Grade 5 CF incl. abutment screw Type SF Screw channel angled overthe flat of the scanbody Type Recommended torque: 20 NcmType 1Type SFImplant connectionD 3,4D 4,1D 5,0Chimney height3,5-6,53,5-6,53,5-6,5Gingiva height0,35 mm0,35 mm0,35 mmArticle No. Type 1/SFH 1600-1-SFH 1610-1-SFH 1620-1-SFAbutment screwH 63H 63H 63Please note:To screw in the titanium base ASC Flex you need the Placement instrument Ball-TorxM 03-8, M 10-8 or 6-13-06. To select the desired direction of the angled screw channel,please consider the Instruction for use.Modelling cap set burn-out plastic Scope of Delivery: four chimneyheightsModelling capset straightModelling capset angled6-09-016-09-116-09-196-09-026-09-126-09-20as of Dec.Titanium base ASC Flexrotating angled screw channel Titanium Grade 5 CF incl. abutment screw Recommended torque: 20 NcmImplant connectionD 3,4D 4,1D 5,0Chimney height3,5-6,53,5-6,53,5-6,5Gingiva height0,35 mm0,35 mm0,35 mmArticle No.H 1800H 1810H 1820Abutment screwH 63H 63H 63Please note:To screw in the titanium base ASC Flex you need the Placement instrument Ball-Torx M03-8, M 10-8 or 6-13-06.Modelling cap set burn-out plastic Scope of Delivery: four chimneyheightsModelling capset straightModelling capset angled36*is a registered trademark of an independent third party6-09-016-09-116-09-196-09-026-09-126-09-20

I-SeriesBIOMET 3i External HexTitanium base ASC Flex angled screw channel Titanium Grade 5 CF incl. abutment screw Type SF Screw channel angled overthe flat of the scanbody Type Recommended torque: 35 NcmType 1Type SFImplant connectionD 3,4D 4,1D 5,0Chimney height4,5-6,54,5-6,54,5-6,5Gingiva height0,5 mm0,5 mm0,5 mmArticle No. Type 1/SFI 1600-1-SFI 1610-1-SFI 1620-1-SFAbutment scre

Camlog Camlog * C-Series Conelog . OSSTEM Implants TS System OT-Series Straumann Bone Level L-Series Tissue Level N-Series T-Plus Implant Tech A Implant OT-Series ST Implant OT-Series Zimmer Dental Tapered Screw-Vent * R-Series . 4 Titanium base ASC Flex - The original from Medentika Medentika PIONEER TITANIUM BASE One design. 5 compatible with all major implant systems The .