CheckMate Inline Check Valve - Water Environment Federation

Transcription

CheckMate Inline Check ValveRe d Valve Co mpanyCheckMate Check ValveRe d Valve Co mpany1

CheckMate Inline Check ValveClosedOpeningRe d Valve Co mpanySystem Challenges CSO communities are looking for a long termapproach to prevent overflows Municipalitiesface system and financial challenges in reachingtheir goal(s). System challenges in the collection system:– Inflow and infiltration reduces capacity– Connections residential/commercial growth– Undersized Pipes frequent CSO eventsRe d Valve Co mpany2

CheckMate Cost SavingsRemoved from Project 110K/site saved indesign, excavation andlabor x 3 sites. Totalsavings 300,000.00 Re d Valve Co mpanyInfluent and Effluent PipeInstallations in ManholeRe d Valve Co mpany3

CheckMate SizesRe d Valve Co mpanyCheckMate Inline Check ValveBucketRe d Valve Co mpany4

CheckMate ManufacturingRe d Valve Co mpanyCheckMate In-House Flow TestingRe d Valve Co mpany5

CheckMate In-House Flow TestingRe d Valve Co mpany6”, 12”, 24” CheckMate IndependentFlow Testing at Utah State UniversityRe d Valve Co mpany6

In-House Backpressure TestingRe d Valve Co mpanyCheckMate Installation OptionsRe d Valve Co mpany7

Upstream Clamp - 18” KingsCounty Park SeattleRe d Valve Co mpanyDownstream Clamp - Clear CreekMall, TXRe d Valve Co mpany8

Downstream ClampRe d Valve Co mpany(10) 42” CheckMates (Pumped Application)Hidalgo & Cameron County Irrigation Dist. #9, TXRe d Valve Co mpany9

(2) 60” CheckMate Valves - AustraliaRe d Valve Co mpany72” CheckMate-Float, Sink, PullFlorida DOTRe d Valve Co mpany10

Installation Procedure – Lubricate O.D.Re d Valve Co mpanyInstallation Procedure - LowerRe d Valve Co mpany11

Installation Procedure - InsertRe d Valve Co mpanyInstallation Procedure – Clamp & PinRe d Valve Co mpany12

Installation Procedure – Clamp & PinRe d Valve Co mpanyLouisville, KYRe d Valve Co mpany13

Installation ProcedureDoDon’t DoRe d Valve Co mpanyOpening of a Large CheckmateRe d Valve Co mpany14

Rubber Adhesive Strip to Field Fitfor Snug FitRe d Valve Co mpanyTandem CheckMateRe d Valve Co mpany15

Arch Pipe CheckMate Check ValveRe d Valve Co mpanyElliptical CheckMate Check ValveRe d Valve Co mpany16

Flanged UpstreamRe d Valve Co mpanyCheckMate Installation OptionsRe d Valve Co mpany17

CheckMate Thimble InsertRe d Valve Co mpanyThimble Insert-World Trade CenterRe d Valve Co mpany18

World Trade CenterRe d Valve Co mpanyWorld Trade CenterRe d Valve Co mpany19

World Trade CenterRe d Valve Co mpanyRe d ValveCo mpany600 North Bell Ave.Carnegie, PA 15106P: (412) 279-0044F: (412) 279-7878www.redvalve.comwww.tideflex.comRe d Valve Co mpany20

CheckMate Inline Check Valve Closed Opening System Challenges CSO communities are looking for a long term approach to prevent overflows Municipalities face system and financial challenges in reaching their goal(s). System challenges in the collection system: