Sample Tube Consumables And Instruments Catalogue

Transcription

Sample Tube Consumablesand Instruments Cataloguebrookslifesciences.com

INTRODUCTION8. FluidX Sterilisation ServicesFluidX Sterilisation Services.65Contents. 1Guide to FluidX Next-Generation Tubes . 2Glossary of Terms . 2FluidX Sample StorageConsumables and Devices. 4Anatomy of a Tube. 81. FluidX Sample Storage Tube RangeTube Range.14Introduction to FluidX External ThreadNext-Generation Jacket Tri-Coded Tubes.16Introduction to FluidX Internal ThreadNext-Generation Jacket Tri-Coded Tubes. 17CONSUMABLES2. FluidX Next-Generation JacketTri-Coded Sample Storage Tubes0.26ml external thread.210.5ml external thread.221.0ml external thread.231.5ml external thread.241.9ml external thread.253.8ml external thread.267.6ml external thread. 273. FluidX JacketTri-Coded Sample Storage Tubes1.8ml internal thread.315.0ml external thread.32Tissue tubes.33Glass tubes . 352.0ml external thread.364.0ml external thread.366.0ml external thread.364. FluidX Next-GenerationDual-Coded Sample Storage Tubes0.3ml internal thread.400.7ml internal thread.410.9ml internal thread.420.5ml external thread.430.9ml external thread.445. FluidX 2D-Coded Sample Storage Tubes9. Recommended Temperature Range forFluidX Sample Storage TubesRecommended Temperature Range forFluidX Sample Storage Tubes.69How Safe Are Your Samples?: Leachables,Working Volume and Pressure Testing. 70INSTRUMENTS10. FluidX Barcode Reading SystemsOrbit single tube barcode reader. 73Scope single tube readers.75Impression whole rack scanner. 78Perception whole rack 1D/2D readers.80HD reader.82HD AcoustiX reader.83HD LF reader.84Intellicode Decoding software.8511. FluidX Capping and Sealing SystemsAperio semi-automated systems for screw caps.89IntelliXcap capper/decapper.91X-CAP semi-automated septum sealer for 96-format.93XDC-96 for 96-format septum capping/De-capping.94X-Peel microplate desealer.96A4S Automatic Roll Heat Sealer. 9712. FluidX Sample Tube Management SystemsXTP1 Manual tube picker. 101IntelliXmark. 102Rack Thawing Station. 104FrostX2. 105Tube Auditor. 106FreezerPro .107Automated Sample Storage. 108CONTAINERS/TRANSPORT13. Biocision Key ProductsCryoPod Carrier. 113CoolCell containers. 114CoolCell XL. 115CoolCell FTS. 116Cell cryopreservation accessories.117Vial grippers.117TruCool hinged cryoboxes.1170.2ml external thread.481.8ml internal thread.491.8ml external thread.506. FluidX Non-Coded Sample Storage TubesFluidX Non-Coded Tubes.537. FluidX Capping and Sealing OptionsFluidX Screw caps. 57FluidX TPE septum caps.59FluidX SBS cap carriers.61www.brookslifesciences.com1

A Guide to our FluidXNext-Generation TubesAs we expand our range of FluidX Next-Generation tubes, weare introducing a new naming convention standard. This willinclude updating the product names and descriptions of ourexisting range and our new product introductions.Jacket Tri-codedEach tube features a permanent 2D-code laser etched inhigh-contrast on the tube base, a permanent 1D (linearbarcode) and Human-Readable Number laser etched in highcontrast on the tube side.The original jacket tube is manufactured using a two-piecemanufacturing process which requires additional assembly.All three codes are identical and auditing processesguarantee all three codes match. Our standard 2D option isblack on white.Glossary of Terms2D Datamatrix codeUnique pattern of squares, dots, hexagons and othergeometric shapes printed on the base of a tube1D-code / Linear barcodeUnique barcode represented by parallel lines of differentwidths and spacings printed on the side of a tube, SBS rackor CryoBox. Our standard code is code 128.Code 128 isable to encode alpha-numeric data2D-coded2D-code on tube baseDual-coded2D-code and Human-Readable Number on tube baseNext-Generation Jacket Tri-codedTri-codedEach tube features a permanent 2D-code laser etched inhigh-contrast on the tube base, a permanent 1D (linearbarcode) and Human-Readable Number laser etched in highcontrast on the tube side.The Next-Generation jacket tube is manufactured using anadvanced manufacturing process which results in a onepiece jacket tube. All three codes are identical and auditingprocesses guarantee all three codes match. All three codesare identical and auditing processes guarantee all threecodes match. Our standard 2D option is black on white.2D-code on tube base, 1D (linear barcode) and HumanReadable Number on tube sideNext-Generation 2D-coded JacketOur Next-Generation jacket tubes are also available witha 2D-code laser etched on the base only. Allowing usersto add additional information or second identifier in highcontract to the tube side. Our standard 2D option is black onwhite.Dual-coded tubesEach tube features a permanent 2D-code and HumanReadable Number laser etched in high-contrast on the tubebase.The Next-Generation Dual-coded tube is manufactured usingan advanced manufacturing technique used to integrate 2resin colors into the same tube for high resolution coding.Both codes are identical and auditing processes guaranteeboth codes match.Our standard 2D option is white on black.Jacket tubeStandard tube with a fixed black cover to facilitate rapid coderecognition and readingNext-Generation tubeNext-Generation manufacturing technique used to integrate2 resin colors into the same tube for high resolution coding.External ThreadThread is on the outside of the tube so there is no lossin working volume when a cap is added, saving valuablefreezer space. FluidX external thread caps feature a doublestart thread. The thread is fully engaged after a maximumrotation of 180o, making the cap easier to use especially inautomated environments.Internal ThreadThread is on the inside of the tube. Next-Generationmanufacturing process means our co-molded tubesNon-coded tubesSimply come as they are2www.brookslifesciences.com

IntroductionALL ABOUT THE SAMPLE!As a global leader in innovative sample management solutions Brooks Life Sciences is all about the sample.Working across a wide range of industries Brooks Life Sciences offers unparalleled knowledge and experience of 2D-codedsample storage tubes, readers and sample management systems. As part of the team that developed the original 2D-codedsample tubes in 1999, we have been at the global forefront of developing sample storage consumables and instruments for nearly20 years and we continue our philosophy of innovation to this day.In addition to the innovation behind our products, we are committed to providing the highest levels of customer service, supportand quality. Our Technical Support Team provides expert assistance, making sure our products give the reliable and optimalperformance you expect.We believe that a quality sample is the cornerstone in the generation of reliable, reproducible and quantifiable data - which is whyBrooks Life Sciences is all about the sample.www.brookslifesciences.com3

FluidX Sample Storage Consumables and DevicesFluidX tubes are available in a range of formats, including racked, loose, bulk, cappedand uncapped. Our robust code management system ensures each and every code ispermanently affixed, unique and never duplicated. Tubes are suitable for applicationsranging from 121 C to -196 C.All FluidX tubes are developed with broad compatibility in mind, performing withoutcompromise in conjunction with automated code reading, capping and samplemanagement systems from FluidX and all other industry-recognized manufacturers.KEY FEATURESOur coding systems are designedto deliver the highest levels ofsample security and labelingflexibility. We offer tubes with achoice of code, either 2D-code,1D (linear barcode) or HumanReadable Number (HRN). Our Tri-coded tubes have all threeoptions whilst our Dual-coded tubes, can have a 2D-codeand Human Readable Number on the tube base or side.A robust code management system ensures each andevery code is unique and never duplicated, preventing anypossibility of misidentification involving your samples.Every tube is quality checked toensure they meet our exactingstandards for readability.Excellent Sealing: Tubeswork equally well with eitherTPE septum or screw caps. Adouble start thread engages ina maximum rotation of 180 , facilitating automation.Ideal for Cold Storage: Temperature range from -196 C(with screw cap) to 121 C. All our polypropylene tubes aresuitable for cryogenic storage, but not for submersion inliquid phase nitrogen.All FluidX polypropylene sample storage tubes sealedwith a screw cap are suitable for use in cryogenic storageconditions.Superior Datamatrix code quality:FluidX sample storage tubes are easy to read even in harshconditions or when damaged. Our 2D-codes adhere fully tothe ECC200 standard. All codes are generated using thelatest and most sophisticated error correction methods andhigh quality, permanent laser etching provides sharp detail.Automation Friendly:Screw capped tubes are compatible with our range ofcappers and decappers, includung our IntelliXcap range.Available in 24, 48, and 96 format to automatically removeand re-cap a complete rack of tubes. The TwistLock featureprevents the tubes rotating in the rack during capping andde-capping.4Integration friendlywww.brookslifesciences.com

CHOICE OF CODING OPTIONSNext-Generation Jacket Tri-coded:Each tube features a permanent 2D-code laser etched inhigh-contrast on the tube base, a permanent 1D (linearbarcode) and Human-Readable Number laser etched in highcontrast on the tube side.The Next-Generation jacket tube is manufactured using anadvanced manufacturing process which results in a onepiece jacket tube. All three codes are identical and auditingprocesses guarantee all three codes match. Our standard2D option is black on white.Jacket Tri-coded:Each tube features a permanent 2D-code laser etched inhigh-contrast on the tube base, a permanent 1D (linearbarcode) and Human-Readable Number laser etched in highcontrast on the tube side.The original jacket tube is manufactured using a two-piecemanufacturing process which requires additional assembly.All three codes are identical and auditing processesguarantee all three codes match. Our standard 2D option isblack on white.Non-coded - simply come as they are.2D Datamatrix code – unique pattern of squares, dots,hexagons and other geometric shapes printed on the base ofa tube.1D-coded / Linear barcode - unique barcoderepresented by parallel lines of different widths and spacingsprinted on the side of a tube, SBS rack or CryoBox. Ourstandard code is code 128. Code 128 is able to encodealpha-numeric data2D-coded – 2D-code on tube base.Dual-coded – 2D-code and Human-Readable Number ontube base or side.Tri-coded – 2D-code on tube base, 1D (linear barcode) andHuman-Readable Number on tube side.Jacket tube – standard tube with a fixed black cover tofacilitate rapid code recognition and reading.Next-Generation – Next-Generation manufacturingtechnique used to integrate 2 resin colors into the same tubefor high resolution coding.Next-Generation Dual-coded:Each tube features a permanent 2D-code and HumanReadable Number laser etched in high-contrast on the tubebase or side.The Next-Generation Dual-coded tube is manufactured usingan advanced manufacturing technique used to integrate 2resin colors into the same tube for high resolution coding.Both codes are identical and auditing processes guaranteeboth codes match.Our standard 2D option is white on black.SBS Storage Rack OptionsFluidX tubes are compatible with industry standard SBSsized racks in either: 24, 48, 96, 240 or 384 format.Dependent upon tube type, the following rack options areavailable.Dual-Coded(white on black)www.brookslifesciences.com2D-Coded(black on white)5

TwistLock:prevents tubes rotating withinthe rack to enable automatedcapping and de-capping of screwcaps. TwistLock is provided asstandard with the option availableto remove.TwistLockLidLock:racks fitted with a LidLock latchare designed to withstand a 1mdrop for added sample security.LidLockTubeLock:tubes can be lockedinto the rack toprevent falling out,even when there is nolid present. Tubes canbe placed in eitherlocked or unlockedpositions. TubeLockis used in manualworkflows and isactivated by applyingpressure to the tubetop, clicking the tubeinto place. Rackedtubes can be orderedeither pre-locked ornon-locked.TubeLockAutomatic Rack Orientation:racks can be supplied witha unique 2D-code identifierwhich can be read at the sametime as the tube 2D-code.This provides automatic rackorientation and more securesample tracking.Direct Laser Etching:a cutout window on the racksides allow the linear barcode to be read more easily; linearbarcodes can be laser etched directly onto racks.6www.brookslifesciences.com

Cryo RacksIn addition to industry standard SBS racks, a range of tubeand application specific cryo racks are available. Each cryorack incorporates: Open bottom for 2D-code decoding on FluidX PerceptionHD LF reader Direct laser etched 1D linear barcode and 2D rack ID onbase of rack.9x9 Cryo Storage RacksMM 136.2mm x 136.2mm polycarbonate cryo rack option forcryogenic sample storageMM Holds 81 tubes in 9 x 9 array9 x 9 rack10x10 Cryo Storage RacksMM 136.2mm x 136.2mm polycarbonate cryo rack option forcryogenic sample storageMM Holds 100 tubes in 10 x 10 array14 x 14 Cryo Storage RacksMM 136.2mm x 136.2mm polycarbonate cryobox rack optionfor cryogenic sample storageMM Holds 196 tubes in 14 x 14 arrayWARNINGDo not store any FluidX tubes in liquid phasenitrogenIngress of nitrogen into the tube can occurcausing the tube to rupture when taken out ofstorageMay cause injury and loss of tube contents.10 x 10 rack14 x 14 rackwww.brookslifesciences.com7

Anatomy of a FluidX Tube (Internal Cap)FluidX 96-format, Internal Thread, Next-Generation Dual-coded tubes have a range of features that are only possible withadvanced manufacturing techniques. Next-Generation co-molded caps offer a far superior seal over traditional O-ring caps, whichcan 'pop' when a sample is frozen or the cap is overtightened.Internal Threaded Cap: Automation friendly Co-molding prevents o-ring ‘popping’ Our most secure internal threaded capHigh Quality Virgin Polypropylene: No detectable leachables or extractables Manufactured in ISO Class 8 clean-roomenvironment Endotoxin, DNase/RNase, heavy metals &animal freeClear Window: Allows visual inspection Optional space to print direct due to highquality manufacturing2D-coded: 2D-code and Human-Readable Number(HRN) on tube base Enables whole rack or single tube reading High contrast enabling reliable reading Permanent laser etching8www.brookslifesciences.com

Anatomy of a FluidX Tube (External Cap)The FluidX External Thread Next-Generation Jacket Tri-coded tube offers our most secure seal. This highly secure design alsooffers significant benefits over internal thread caps including, a higher working volume.External Threaded Cap: Automation friendly Our most secure cap Enables greater working volume Designed to prevent over tighteningHigh Quality Virgin Polypropylene: No detectable leachables or extractables Manufactured in ISO Class 8 clean-roomenvironment Endotoxin, DNase/RNase, heavy metals &animal freeSide Coding: Linear Barcode Human-Readable Number Permanent laser etchingClear Window: Allows visual inspection Optional space to print direct due to highquality manufacturing2D-coded: Enables whole rack or single tube reading High contrast enabling reliable reading Permanent laser etchingwww.brookslifesciences.com9

Anatomy of a FluidX Tube Next-GenerationDual-Coded TubeExternal Threaded Cap: Automation friendly Our most secure cap Enables greater working volume Designed to prevent over tighteningHigh Quality Virgin Polypropylene: No detectable leachables or extractables Manufactured in ISO Class 8 clean-roomenvironment Endotoxin, DNase/RNase, heavy metals &animal freeClear Window: Allows visual inspection Optional space to print direct due to highquality manufacturingDual-Coded: 2D-code and Human-Readable Number(HRN) on tube base Enables whole rack or single tube reading High contrast enabling reliable reading Permanent laser etching10www.brookslifesciences.com

1FluidX Sample Storage Tube Rangewww.brookslifesciences.com

48-format, 1.9mlExtern

All three codes are identical and auditing processes guarantee all three codes match. Our standard 2D option is black on white. Next-Generation Jacket Tri-coded Each tube features a permanent 2D-code laser etched in high-contrast on the tube base, a permanent 1D (linear