PanelSystemsHunterDouglas Panel Systems forSun Control offer excellent design,functionality and comfort withmultifunctional louvre systems.Panel Systems can be installed in aprojected or parallel orientation tothe façade or designed in relation tothe angle of the sun.

Panel SystemsIn line with styleDESIGN FLEXIBILITYHunterDouglas Panel Systems within the Sun Louvreproduct range, give architects the freedom to choose theright system to meet aesthetic, performance and comfortcriteria.Create an elegant, light appearance with gently curved/segmented edges with aluminium rollformed panels 84R,70S and 132S. Almost all HunterDouglas Panel Systemscan be mounted on the same substructure and projectedhorizontally, vertically or sloped.DURABILITYThe high quality components, used to manufacturethe Panel Systems, deliver high performance and lowmaintenance: products built to last.EASY INSTALLATIONPanel Systems are easy and quick to install with very fewtools required. All systems can be installed using the sameextruded aluminium substructure.Steel wall brackets fitted to the façade ensure the carrierprofiles with brackets or stringers are easily fixed in place.Panels are snapped into place on the brackets or stringerswithout tools.

All Panel Systems (84R, 70S/132S) are aluminiumsingle skin panels with a range of support structures.Horizontal and vertical projections come in a varietyof panels and modulations to meet the projectspecification and design.CONTENTLIGHT, HEAT & ENERGYBecause great looks are not enough, Hunter Douglashas developed computer simulation and calculationtools to ensure optimal shading performance.Considering location, building orientation, pre-definedbuilding requirements and local weather data, ourproject support team can analyse and custom-optimisethe Sun Control system for each project.Page84R270S/132S4Substructure6Design Options8Impressions9Material specifications10Light, Heat & Energy11Designed to work for youTM')68-*-)(&632 )Production byHunter DouglasCeiling Center

84RCHORIZONTAL SYSTEMwith modular carrierASYSTEM DESCRIPTIONThe HunterDouglas 84R Panel Systemis a classic system ideal for straight,curved or sloped façade applicationsand has an elegant and light appearancewith smooth rounded edges.INSTALLATIONHunterDouglas 84R Panel System iseasy and quick to install with a minimumof tools required. When the steel wallbrackets* are fitted to the façade, thecarrier profiles with (pre-fixed) bracketsand spacers or stringers slide over thewall brackets and are easily fixed with abolt-through connection. The C-shapedpanels (in full length) are clipped on tothe brackets.A wide range of carrier profiles withfixed or variable modulation is availableto ensure that optimal shading anglesand openness are achieved for eachapplication. 84R Panel Systems can alsobe used as ventilated façades.8416DA panel spanB cantilever spanC carrier spanD moduleBOTHER SUPPORT STRUCTURES:Modular system &rectangular hollow sectionCarrier profile & stringerVERTICAL SYSTEMwith modular carrierThe 84R Panel System can be installedin 5 ways:Stringer & rectangular hollowsection (in combination withwasher sets)1621234563Horizontal84R Panel (Alu)Sloped wall bracket*carrier profilespacerpanel bracketpanelend cap16Vertical844Combination584R Panel (Alu) 67CurvedSide view* The steel wall brackets are usuallydesigned and manufactured by theinstallers and are not a standardisedpart of the system2OTHER SUPPORT STRUCTURES:Modular system &rectangularhollow sectionHunterDouglas Sun Control - Panel SystemsModular system &direct fixing clipCarrier profile &stringerStringer & rectangularhollow section (incombination withwasher sets)

84RCARRIER SYSTEMSA variety of carrier systems is availableallowing the optimal solution for eachapplication:- the fixed SL-2/3/4/5 stringers- the self supporting extrudedSLR-40/60/60V/100 and the directmount SLR-10 with different modulesby using different spacers andbrackets.Each solution has its own modulationand shading angle.SHADING ANGLES - HorizontalModular systemFixed systemXXModular systemx7489114Spacer486388aStringerSL-2*SL-4*67 57 45 Fixed systemx7486a66 67 * to be mounted on top of a rectangular hollow sectionSee page 6 - 7 for a complete overviewof stringers and carrier systems suitablefor 84R.MATERIALThe 84R panels are roll formed from0.6 mm thick pre-painted (Luxacote system) stove enameled aluminiumstrip of corrosion resistant alloyEN-AW-3005.The stringers are roll formed pre-paintedprofiles. The SLR-carrier system,brackets and spacers are aluminiumextruded profiles.SHADING ANGLES - VerticalModular systemFixed systemXXModular systemx7186111Spacer486388aStringerSL-3SL-4SL-58 23 41 Fixed systemx698674a0 21 23 SHADING ANGLES - AngledThe shading angle of a sun control system mounted under an angle is different to ahorizontal projected system. For each individual mounting angle the shading anglecan be calculated by our project support team (also for combined systems).MAXIMUM SPANSPanel SpanThe panel span in relation to the windload (pressure or suction), can becalculated from the graph on the right.Note: Calculating the value of the localwind load is the responsibility of theinstaller who must take into account theregulations laid down by local authorities.For corners, roof edges or special designs,wind pressure/suction shall be determinedwith due consideration of the relevantlocal country’s Standard Code of BuildingPractice.suction panel on 3 or more carrierssuction panel on 2 carrierspressure panel on 3 or more carrierspressure panel on 2 carriers3000Wind load [N/m2]There are two graphs per wind loadtype based on the application:- If a multi-span panel system isrequired, consult the ‘3 carriers ormore’ graph.- When using 2 carriers, consult the‘2 carriers’ graph.Panel span nel span [m]For other carrier tables using our stringers or the modular carrier system, pleaseconsult the Hunter Douglas sales office. For snowloads consult your localbuilding regulations.HunterDouglas Sun Control - Panel Systems3

SYSTEM DESCRIPTIONThe HunterDouglas 70S and 132SPanel System consist of sturdyZ-shaped panels. The panels provide acrisp, pleasing aesthetic design.CHORIZONTAL SYSTEMwith modular carrierA(Only for 70S)INSTALLATIONHunterDouglas 70S and 132S PanelSystems are quick and easy to installwith a minimum of tools required. Whenthe steel wall brackets* are fitted to thefaçade, the carrier profiles with (prefixed) brackets and spacers slide overthe wall bracket and are easily fixed witha bolt-through connection. The Z-shapedpanels (in full length) are clipped ontothe brackets.OTHER SUPPORT STRUCTURES:A wide range of stylish carrier profileswith sliding brackets are available toensure that optimal shading anglesand openness are achieved for eachapplication.70S and 132S Panel Systems can alsobe used as ventilated façades.Modular system &rectangular hollow section (Only for 70S)DBVERTICAL SYSTEMwith modular carrierThe 70S and 132S Panel System can beinstalled in 3 ways:6A panel spanB cantilever spanC carrier spanD module41.57070S/132S70S Panel (Alu)13261 wall bracket*2 carrier profile3 spacer4 panel bracket5 panel6 end THER SUPPORT STRUCTURES:* The steel wall brackets are usuallydesigned and manufactured by theinstallers and are not a standardisedpart of the system4Modular system &rectangular hollow sectionHunterDouglas Sun Control - Panel Systems70S Panel (Alu)Modular system &direct fixing clip132S Panel (Alu)

70S/132S CARRIER SYSTEMSA variety of carrier systems is availableallowing the optimal solution for eachapplication:- the self supporting extrudedSLR-40/60/60V/100 and the directmount SLR-10 with different modulesdue to different spacers and brackets.Each solution has its own modulationand shading angle.See page 6 - 7 for a complete overviewof carrier systems suitable for 70S and132S.SHADING ANGLES - HorizontalX70SSpacer48 mm63 mm88 mmax759011567 57 44 SHADING ANGLES - VerticalMATERIALThe 70S and 132S panels are rollformed from 0.6 mm pre-painted(Luxacote system) stove enamelledaluminium strip of corrosion resistantalloy EN-AW-3005.The SLR-carrier system, brackets andspacers are aluminium extruded profiles.XX70S132SSpacer48 mm63 mm88 mmax7085110Spacer88 mm126 mm*1176 mm*20 20 43 ax1321702200 22 42 * 1 126 mm (2 x 63 mm) - * 2 176 mm (2 x 88 mm)SHADING ANGLES - AngledThe shading angle of a sun control system mounted under an angle is different to ahorizontal projected system. For each individual mounting angle the shading anglecan be calculated by our project support team (also for combined systems).MAXIMUM SPANSPanel SpanThe panel span in relation to the windload (pressure or suction), can becalculated from the graph to the right.Note: Calculating the value of the localwind load is the responsibility of theinstaller who must take into account theregulations laid down by local authorities.For corners, roof edges or special designs,wind pressure/suction shall be determinedwith due consideration of the relevantlocal country’s Standard Code of BuildingPractice.70S Panel on 2 or 3 carriers70S Panel on 4 or more carriers132S Panel on 2 or 3 carriers132S Panel on 4 or more carriers3000Wind load [N/m2]There are two graphs per wind loadtype based on the application:- If a multi-span panel system isrequired, consult the ‘4 carriers ormore’ graph.- When using 2 or 3 carriers, consult the‘2 or 3 carriers’ graph. Panel span 70S el span [m]For other carrier tables using our modular carrier system, please consultthe Hunter Douglas sales office. For snowloads consult your local buildingregulations.HunterDouglas Sun Control - Panel Systems5

86 mm66 mmSubstructureDESCRIPTIONFor the 84R, 70S and 132S PanelSystems there is a variety of (self suppor ting) extruded carriers available.The 84R Panel System also hasstringers available (see page 7).SELF SUPPORTING CARRIERS:To apply the SLR-self supportingcarriers, only a wall bracket* is required.Carriers can be fixed directly on thewall-bracket, except the SLR-10.SLR-10 is fixed directly on the façadewith the direct fixing clip (verticalinstallation) or on a rectangular hollowsection (horizontal installation).The extruded aluminium profiles of theSLR-system are available in:- natural anodised finish- mill finish to be powder coated /anodised in any colourEach panel system is designed with itsown specific brackets and spacers thateasily slide into the SLR-carriers(See page 7)HORIZONTAL SYSTEMSLR-10SLR-4066 mm19 mm- to be used on a support structure- for 84R and 70SSLR-60- to be used directly on wall bracket(40 x 10 mm)- for 84R and 70SSLR-10086 mm- to be used directly on wall bracket(60 x 10 mm)- for 84R and 70S128 mm- to be used directly on wall bracket(100 x 10 mm)- for 84R and 70SVERTICAL SYSTEMSLR-10SLR-60V19 mm86 mm86 mmThe SLR-carriers can be closed with aspecific end cap (excluding the SLR-10).- to be used on a support structure- for 84R, 70S and 132S19 mm- to be used directly on wall bracket(with thickness 10 mm)- for 84R, 70S and 132SGENERAL PRODUCTS128 mmWall Bracket- direct fixing clip for the SLR-10End Cap- a vailable for the SLR-40, 60, 60V and 100128 mm* The steel wall brackets are usuallydesigned and manufactured by theinstallers and are not a standardised part of the system6HunterDouglas Sun Control - Panel Systems

Specific carriers / ComponentsDESCRIPTIONThe self supporting carriers and panelsystem have specific brackets andspacers.84R SYSTEMFixed stringers are available to createmore flexibility and can be mounted on:- SLR-system- Rectangular hollow section(in combina tion with washer sets)COMPONENTS FOR THE SLR-SYSTEM48 mmHorizontal Bracket (65º)(natural anodised)SL-2 (65º)Vertical Bracket (45º)(natural anodised)SL-4 (45º)SL-3 (66º)Stringers for horizontal applications(pre-painted)63 mm88 mmSpacers(natural anodised)SL-4 (45º)SL-5 (25º)Stringers for vertical applications(pre-painted)70S SYSTEM48 mmHorizontal Bracket (65º)(natural anodised)Vertical Bracket (65º)(natural anodised)63 mm88 mmSpacers(natural anodised)132S SYSTEM48 mmVertical Bracket (65º)(natural anodised)63 mm88 mmSpacers(natural anodised)HunterDouglas Sun Control - Panel Systems7

ARCHITECTURAL PRODUCTSSun-Louvres Type 84R SL-2Design OptionsCORNER SOLUTIONSFor each of the HunterDouglas PanelSystems we offer solutions for everycorner. As standard we have thefollowing solutions per system.System84R70S132SAx*x*xBx*x*xCxxxDxxx* These corners are easy to create withour standard corner bracketsARCHITECTURAL PRODUCTSSun-Louvres Type 84R SL-2A: F ragmented Cut(Panels have to be cut on site)CORNER SOLUTION-3 TOP VIEWC: Straight CutSCALE. 1:20.CORNER SOLUTION-1 TOP VIEWB: Mitre Cut(Panels have to be cut on site)SCALE. 1:20.D: Open CornerCORNER BRACKET84R and 70S panels in combinationwith the Hunter Douglas SLR systemcome with a standard adjustable cornerbracket. With the corner bracket you caneasily install panels in every possiblecorner.CORNER SOLUTIONAngleαbOutside8From45 180 InsideTill180 270 Installation of the 84R panel with the adjustable corner bracket(also standard available for 70S)(Panels have to be cut on site)HunterDouglas Sun Control - Panel Systems

ImpressionsProject : Police OfficeLocation : Dongen, the NetherlandsProduct : 84R with corner solutionProject : ComairLocation : Kempton Park, South AfricaProduct : 70S with corner solutionHunterDouglas Sun Control - Panel Systems9

Material specificationsROLL FORMED 84R, 70S AND132S PANELSThe panels are roll formed from0.6 mm thick pre-painted (Luxacote system) stove enameled aluminium strip(according to EN 1396). The stripis made from a corrosion resistant alloyEN AW-3005 or equivalent.LUXACOTE (ONLY FOR THE ROLL FORMED PANELS)Luxacote is an exclusive Hunter Douglas innovationthat enhances the durabi

VERTICAL SYSTEM with modular carrier 84 16 84 16 * The steel wall brackets are usually designed and manufactured by the installers and are not a standardised part of the system Horizontal Sloped Vertical Curved 67 Side view Combination Modular system & rectangular hollow section Carrier profile & stringer Stringer & rectangular hollow section (in combination with washer sets) Modular system .