TITAN SKY - Swegon

Transcription

TITAN SKYTITAN SKYFull inverter chiller and reversibleheat pump with natural refrigerant30 200 kW

TITAN SKYT H EN A T U R A LC H O I C ETHE MOST SUSTAINABLE COMMERCIALAIR SOURCE CHILLER & HEAT PUMPInverter compressorNatural refrigerant (R290)Lowest TEWI (Total Equivalent Warming Impact)Unbeatable use of Primary energy thanks to Inverter technology No Ozone Layer impact & Nearly Zero Global warming potential Optimized LowRefrigerant Charge design Meets the highest seasonal efficiency standard(European Ecodesign Erp) Eurovent certificationHEAT PUMP30-200 kW Max Hot water: 63 C Min Tair: -20 C SCOP: up to 4.12CHILLER30-200 kW Min Cold water: -15 C Max Tair: 52 C SEER: up to 4.60Natural refrigerantInverter technologyAdvanced control

CLIMATECHANGEFIGHTEUROPEAN CLIMATE STRATEGYIS GOING TO BE UPDATED ANDREINFORCEDTARGETHOW?Reduction of 55% GreenhouseGas emission by 2030F-gas regulation RegulationRenewable Energy DirectiveIncreased renewable energy(above 32%) by 2030European Performance ofBuildings Directive (EPBD)Net-zero Greenhouse GasEmission by 2050Ecodesign ERP DirectiveKeep temperature increasebelow 1.5 CR290 HC3H₈HREFRIGERANTC3H₈N AT U R A LBecome a climate neutraleconomyHCCHHCHHTEWI % compared to R410A baselineSMART CHOICE No carbon tax Pushed by incentivation schemes Future-proof natural solution. On going HFCphase-outGlobal warming potential 54BHSwedenelectricity carbon intensityB 0,008 kgCO2 / kWh200 kW reversible HP unitsEN14825 Average climate conditionLow temperature heating system,fan coil cooling systemTitan Sky207228233244UKHCPlant cooling / Heating loadEfficiencyElectricity consumptionCO2 emission intensityEuropean electricity carbon intensityis dropping, so natural heat pumpsbecome day by day more sustainable86and will contribute to91126Europedecarbonization145167and climate neutralityITALYPORTUGALAV . HIAGREECEAv. European 00100200300400500600700800Electricity emission intensity [gCO2e/kWh]2019 data, Source Heq.]Titan Sky is the heat pump with thelowest carbon footprintin the market100% Long run reciprocating compressor with invertertechnology Implementation of the highest safety standard3H₈2Direct emissions Indirect emissionsHRELIABLE CHOICEHHTEWI [tons COLeakage rate per yearService life (years)Leftover refrigerant after disposalGlobal Warming Potential HNearly zero Global Warming Potential (GWP 3)Natural fluidNatural non toxic refrigerantNo Ozone Layer impact-40% gas charge compare to R410A2088HT O TA L E Q U I V A L E N T W A R M I N G I M PA C THSUSTAINABLE CHOICE TEWI891900H

CAPACITYRANGETITAN SKY Hi R0 SINGLE CIRCUITTITAN SKY Hi R0 DOUBLE CIRCUITTITAN SKY Hi HP R0 SINGLE CIRCUITTITAN SKY Hi HP R0 DOUBLE CIRCUIT30 105 kW on 7 sizes105 200 kW on 5 sizes30 100 kW on 5 sizeskW2030405060708090110 200 kW on 4 sizes100110120130140150160170Chiller and reversible heat pump withreciprocating full inverter compressors optimized for R290180190200EN14511 / EN14825HEAT PUMPOUTSTANDING DESIGNLeaving water T 63 CINDEPENDENTDEFROSTMANAGEMENTTitan Sky Hi HP R0at -7 C outside air T ideal for heating and25 domestic hot waterproduction20151070LWT [ C] Total aeraulic separation Higher supplying stability Reduced plant water volumeR290 heat pumps market65605-10-15-2045505550 Cat -20 C outside air T suitable in anyclimate condition555045-30AIR TEMPERATURE ( C)CHILLERFOR ANYAPPLICATIONSPLENTY OF ROOMfor hydronics circuits and recovery exchangers below the coils-20AIR TEMPERATURE ( C)20 CC H I L L E D WAT E R P RO D U C T I O N40Leaving water T LWT [ C]0-5IT cooling(server rooms,datacenter)18 CComfort(fancoils, chilled beams,radian floor)7 CProcess(food and wine,plastic andchemical industry )-15 C-10010

Monitoring, performance reports, full management.Blue Box control platform allows a total access to the machine from any device, in complete autonomy.Integratedweb serverSET POINToperating set pointMODEunit mode (heating, cooling)UNITvisual status of unit (circuits,compressors.)GRAPHSreal time diagrams of mainvariables (temperatures, pressure.)INPUT/OUTPUTMULTILOGICstatus of inputs / outputs(digital and analogic)management of multiple unitsLOGSdownload and analyze unit data historyBLUEYECONNECTREMOTE ACCESS TO UNITSAVE MONEYFAST SERVICEBLUEYECLOUDCLOUD RECORDING DATAPOINTSPREDICTIVE MAINTENANCECUSTOMER REPORTINGANALYSISBLUETHINK solution to manage several units,components and devices and build anoptimized System.FLOWZERINVERTER-DRIVEN PUMPS CONTROLMANAGEMENT FOR DIFFERENT SYSTEMLAYOUTSCONSTANT FLOW Simpler site’s settings to achieve a real constant flowCONSTANT HEAD PRESSURE The right pressure to the users in any conditionVARIABLE FLOW Full control of one unique hydraulic loop Primary / Secondary Loop, the right solution for anylayoutUP TO-55% savingsin the energy consumption of the pumps comparedto a traditional fixed flow system Advanced algorithms to maximize system total efficiency Less Opex thanks to lower energy consumption Flexible management of multi units, variable water flowand external devices (drycoolers, cooling towers, boilers,.) Real time energy consumption to obtain advanced structured data analysis Modular design to perfectly suit any project requirementsin terms of application, size and complexity

Swegon Operations S.r.l. Via Valletta, 5 - 30010 Cantarana di Cona (VE) Italy www.swegon.com

Full inverter chiller and reversible heat pump with natural refrigerant 30 200 kW TITAN SKY . Reduced plant water volume EN14511 / EN14825 Titan Sky Hi HP R0 R290 heat pumps market CHILLED WATER PRODUCTION. . Modular design to perfectly suit any project requirements in terms of application, size and complexity .