Q-Implant - Trinon

Transcription

Q-Implant

Back to the rootsThe q-implant-conceptThe threadQ-Implant System was developed foreasy and efficient use in dental practice.Designed to provide simplicity and clarity,we have created a system that removesmany of the disadvantages of earlier implant systems. This single-phase enossalimplant is made of titanium and there areno complex components.Its self-cutting thread achieves a highprimary stability which allows the immediate placement of a temporary crown.The transgingival healing makes a secondoperation unnecessary and the sandblasted surface reduces the time taken forosseointegration. These features, togetherwith the mirror-finished implant head, aidwound healing and reduce post-operativeinfections.Q-Implants are constructed with a selfcutting thread. Gentle bone-managementand atraumatical insertion is possible byusing minimal force.Even in the spongious bone of the upperjaw you reach a high primary stability.To reach this goal, we attached maximumimportance in the development of aprogressive designed thread with axialmilling cuts, reducing stress and straineffects.This spreads jaw pressure equally to thebone. The axial cuts also avoid rotation.Bone shavings can be harvested andre-used during osteogenisis.The Implant headq-powerpoints a gap free one piecetitanium implant atraumatic one-phase concept immediate temporisation andimmediate loading possibilities reduced treatment time for bothpatient and dentist easy to follow treatmentsequence clearly arranged titaniuminstrumentsThe top of the implant was designed witha 7 cone. It can be individually grindedand can therefore be treated like a naturaltooth. To avoid rotation, 4 symmetricalaxial slots were placed on top.They also guide the wrench you use toscrew in the implant. This gives you thepossibility to supply the implant with atemporal suprastructure. Before impression,the slots should be blocked out withcomposite. Using a dental dam, you mayeven grind the top during or right aftersurgery. Easy mucosa- and gum- management is possible due to the mirror-finish.Your patient leaves your office with anaesthetic and functional solution on theday of surgery.The surfaceFor maximum osseointegration the surface was etched and blasted with aluminiumoxide.

Q-ImplantQ-Implant surgery steps1Mucosal surgery:Using a TRINON scalpel, the mucosa is opened by a crestal cut. A fold of skin is thenbuilt to uncover the osseous structures. Alternatively a gum punch can be used.2Initial indentation of the bone:Use a rotating drill to create an indentation on the surface of the bone. Alternativelyuse a trocar drill to punch the mucosa if flapless surgery technique is applied.3Pilot drill:Considering both of optimal prosthetic and enossal position of the implant, the rightdirection of the pilot drill is chosen.4Shaping drill:The shaping drill is performed with the selected diameter and length.5Insertion:Taken from the sterile cover the implant is gently inserted into the prepared bonecavern with the insertion wrench. It may be helpful to use the handwheel or thehandwrench. By its self-cutting design the implant gains maximum primary stability.6Suture:After reaching the implants final position, the mucosa is stitched up tightly. This is notnecessary if a gum punch was used.7The suprastructure:A temporal suprastructure is recommended during the healing phase by means ofusing a MultiCap or a Silicone Cap. The final prosthetic suprastructure follows.OR

Prosthetics Procedure1After accomplished woundhealing and without inflammation in mucosal area, theprosthetical process can start. In case the implants head are grinded the prostheticalforming is settled with conventional methods. Normally the slots in the head getblocked out with composite and the standard dental impression is executed.The laboratory model and the dental transformation are the same as providing agrinded tooth.2If the implants head are not grinded the use of MultiCap is recommended. Thismultifunctional cap is shifted onto the implants head and the impression made withan impression spoon.3The laboratory implants (3QLab / 4QLab / 5QLab) are now inserted into the Muticap which are sticking in the impression material for casting the model. Finally the technicallaboratory work can be performed in usual manners.4The choice of a thermoplastic synthetic material gives the dental technician the possibility to use the MultiCap as a burn-out basis for a variety of dental applications.MultiCap has a uniform material strength due to its conical shape and constant thickness. Several laboratory steps are considerably shortened by using these prefabricatedmoulds. MultiCap burns out completely at 850 c (1562 F) without residues, whichallows the use of a wide variety of alloys. Weight In gold approx. 0,8 g (12,35 gr.),which allows for no waste!5After the processing of the model all prosthetic possibilities are available. (e.g. ceramicsfull bridge)

Q-ImplantThe Q-BoxThe Q-Box was designed for clarity andsimplicity. It can be easily stacked into anautoclave and its sturdy construction ensures stability even following many sterilisation procedures. Every system componenthas its own unmistakeable place making iteasy for the operating assistant to locatethe correct component quickly and effi-PilotdrillShapingdrillDrill strumentsciently. The titanium bowl can be used forblending bone augmentation material aswell as the temporary storage of operatinginstruments.Insertion leGum punchIWQS3 mm3QPUNCH4 mmQBOXC2incl. rotating HWQ11x1xDHQ14QPUNCH1x1xQ-Tomwith the Q-Tom set the implantologistreceives a bone-spreading and bonecondensing equipment completing theQ-Implant product range. These osteotomesmade of titanium convince through theirdelicate design, maximum biocompatibilityand elegant handling. The angulation ofthe convex working-ends support the usein frontal as well as in molar region.The Q-Tom set includes seven osteotomesbeginning with a diameter of 1,8 mm.Complete setOsteotom Q-TomNo. 1 – No. 7QTOMCThe diameter rises by 0,2 mm perinstrument to the maximum diameterof 3 mm.Through the minimal spreading of only0,2 mm the operative effort and at thesame time the risk of bone fractures in thespongious region is lowered.The excellent visibility of the lasermarking(length 8, 10, 12, and 14 mm) gives maximum safety for insertion depth.OsteotomQ-Tom No. 1OsteotomQ-Tom No. 2OsteotomQ-Tom No. 3OsteotomQ-Tom No. 4OsteotomQ-Tom No. 5OsteotomQ-Tom No. 6OsteotomQ-Tom No. 7(Bone Spreader)(Bone Spreader)(Bone Spreader)(Bone Spreader)(Bone Spreader)(Bone Spreader)(Bone Spreader)1,8 mm2,0 mm2,2 mm2,4 mm2,6 mm2,8 mm3,0 mmQTOM1QTOM2QTOM3QTOM4QTOM5QTOM6QTOM7

In every case Q-Implant The Q-Implant product range suits all indications.Such as single tooth treatment and bridges, increasement of pillars in reduced set ofteeth and in edentulous jaws.It might be loaded immediately after tooth extraction and serves perfectly for immediatesuprastructure, because of the high primary stability that is achieved by its very specificthread design.Q-Implant, the implant system of the present and future !Q - I m p l a n t GIPa popular and effectiveone-phase conceptan innovative one-phase conceptideal for immediate temporisationappropriate for strongly atrophiedbut wide lower and upper jawand immediate loadingideal for immediate temporisationTwo different neck heights;Standard (4 mm)and Short (2 mm)and immediate loadingin diameter 2,5; 3,5; 3,9; 4,5 and5,6 mmand length 8, 10, 12 or 14 mmavailableneck height 0,6 mmin diameter 6,3 and 7,0 mmand length 4, 5, 6, 7 mm available

Q-ImplantQ3 - I m p l a n t Q K - I m p l a n t Q2 - I m p l a n t one-phase implant withballpoint-headtwo-phase implant withinner conetwo-phase implant with externalhexagonexcellent to be incorporated inexisting overdenturesuniversal in use, fits allindicationssuitable for immediate and delayedloading and temporisationuniversal in use, fits allindicationssuitable for immediate and delayedloading and temporisationin diameter 3,5 mm and 4,5 mmcompatible to manyother systemscompatible to manyother systemsand length 8, 10, 12 or 14 mmavailablein diameter 4,0 and 5,6 mmin diameter 3,5; 3,75 and 4,5 mmand length 8, 10, 12 or 14 mmavailableand length 8, 10, 12 or 14 mmavailableor its implant supportednew creation

SurgeryImplantsStandard4 mmShortQ-Implant 2,5StandardShort2 mm2,5 mm 4,5 mm3,9 mm3,5 mm5,6 mm4,5 mm3,9 mm5,6 mmArt. No.Art. No.Art. No.Art. No.Art. No.Art. No.Art. No.Art. No.Art. No.8 QS145QS085QS105QS125QS1410 mmQ-Implant3,5 mmlength12 mm14 mmGIP-Implant6,3 mmLengthArt. No.Art. No.4 5 mmGIP-Implant6 mm7 mmCone5 mm7 7,0 mmneck0,6 mmQ3 Implant with matrixthread2,3 mm 4,5 mmlengthArt. No.Art. No.Art. No.8 Q31045Q31245Q31410 mmQ3 - I m p l a n t3,5 mm12 mm14 mm2,4 mm ballHEX3 mmQK Implant with cover screwlength8 mm10 mmQ K- I m p l a n t 12 mm14 mm4,0 mmArt. No.5,6 mmArt. tformOCTAGONthread4,8 mm4 mmQ2 Implant with cover screwHEX2,7 mmlength8 mm10 mmQ2 - I m p l a n t 12 mm14 mm3,5 mmArt. No.3,75 mmArt. N0.4,5 mmArt. 20845Q21045Q21245Q214platform4,0 mmthread3,75 mm

InstrumentsPilotdrillShaping drillfor implantsPDQ12,5 mmfor implants3,5 mmSDQ253,9 mmSDQ34,5 mmSDQ4Insertion wrenchDrill for cortical boneSDQ395,6 mm3,5 mmSDHQ33,9 mm4,5 mm5,6 mmSDHQ39SDHQ4SDHQ5SDQ5Insertion hole drillInsertion hole drill for cortical boneshortlongIWQSIWQLQ5108L 4mm5mm6mm7mmQ5104 Q5105 Q5106 Q5107Q5104K5mm6mm7mmQ5105KQ5106KQ5107KShaping drillDrill for cortical bonefor implantsfor implantsInsertion wrench3,5 mm4,5 mm3,5 mm4,5 mmshortlongSDQ3SDQ4SDHQ3SDHQ4Q3123Q3124Shaping drill4,0 mmPDQ1L 4mmQ4101Drill for cortical bone5,6 mmQ4102Insertion wrench5,6 mmQ4103Shaping drill3,75 mmQ21014,5 mmQ2102shortlongQ2123Q2124

Mechanical insertion wrenchHand wheelDriver handleGum punch3 mm4 mm5 mm3QPUNCH4QPUNCH5QPUNCHIKQ3Mechanical Insertion wrenchGum punchQ31203 mm4 mm3QPUNCH4QPUNCHScrewdriverMechanical insertion wrenchHWQ1DHQ1short20 mmshortQ2113 (0,9 mm)Q2114 (1,25 mm)Q2120long30 mmmediumQ2113L (0,9 mm)Q2114L (1,25 mm)Q2121Handpiece for screwdriverlongQ2122Q2112

Q-ImplantLaboratory analogTransfer capMulticap *Silicone CapEasy TemporaryCapwhite caps for dentist impressionfits all systems2,5 mm3,5 mm3,9 mm4,5 mm5,6 mm25QLAB3QLAB39QLAB4QLAB5QLABQCAPQCAPSno SlotslotQ5001 – SQ5002 – MQ5003 – Lblue caps for dental technician onlyAcrylic cap4 mm - 10,5 mmTemporary Prothesis madein 5 minutes.Please ask for detailedinformation.CAP6CAP5no SlotSlotTransfer cap for Q3-Implants**Laboratory analoguefor Q3-Implants**Q3210Q3310Matrix for tandardO-Ringblack,hardO-Ringblue,very softQ3320Q3321Q3322Q3323Cover screwGingivaformer2 mm4 mmQ4003Q4004GingivaformersmallQ40015 mm

Q3-Implant two-phase implant with external hexagon universal in use, fits all indications suitable for immediate and delayed loading and temporisation compatible to many other systems in diameter 3,5; 3,75 and 4,5 mm and length 8, 10, 12 or 14 mm available Q2-Implant Q-Implant two-phase implant with inner cone indications