Get R2GATE! Dominate Digital Dentistry! - Implant Solutions

Transcription

“Diagnosis & Treatment Planning”are the most important.Get R2GATE!Dominate digital dentistry!312

R2GATE: Digital Dentistry316R2GATE369R2GATE Surgical KIT411MegaGen Digital SolutionR2GATETM– 313

314

R2GATETMTurning imagination into realitySINCE 2012316What is R2GATE318Ⅰ. Digital EYEⅡ. One-DAY Implant321R2GATE GUIDE317TMTM325Ⅰ. Advantage of R2GATE GUIDEⅡ. R2GATE Guided Surgery332R2 Digital Center322339Ⅰ. Various R2GATE ServicesⅡ. R2GATE Order ProcessⅢ. R2 Digital Center NetworkⅣ. R2GATE Business Opportunity352R2GATE Lite357Clinical Case333334336TMR2GATETM– 315

What is R2GATEWhat is R2GATE R2GATE is an innovative implant diagnostic software that analyses the oral conditionand it shows the best option for implant treatment.CBCT (Dicom)CBCT is the most efficient method for implant diagnosis. Through CBCT, you caneasily identify the shape of the bone and other skeletal structures. But it has an original distortion and not accurate enough for complete treatment planning by itself.Digital EYE (Bone)After intuitively checking the shape and density of bone via Digital Eye, you canobtain strong initial stability by customizing the drilling sequence.The software also provides a guideline for whether immediate loading is possible or not.STL (Soft tissue &teeth)R2GATE merges the STL (3D scanning of model or impression) with the CBCT fileto overcome the CBCT’s limitations such as Metal Scattering and distortion.STL intuitively shows the gingiva and neighboring teeth.Top-Down TreatmentplanningThe purpose of implant treatment is to recover lost and functionless teeth.With R2GATE, you can select the ideal position of an implant by checking the crowndesign, and occlusion with neighboring and antagonist teeth.The most innovative andintuitive diagnosis softwarefor Dental implant planningin the world.316

What is R2GATE » Ⅰ. Digital EYEⅠ. Digital EYETMDoes your CBCT show you right information?Black and White?It’s only 5%Regular black and white CBCT analyzes the data in 256-level of shades. We canonly detect 16 levels with naked eyes. R2GATE’s Digital EYE regenerates 256shades into color to deliver much more detailed, intuitive bone condition.It standardizes the brightness level that various CT equipment has and providesobjective HOUNS FIELD UNIT.It significantly differs from the color that other CT data provides. Based on thisinformation, you can decide implant position and size and its drilling sequence forthe initial stability of the implant.4%AIRRe-arrange of DICOM filesfor standardization.14%16%26%40%Hard(Bone or teeth)Medium(bone)Soft(tissue or bone)Windowing function standardizes the brightness level that different CT equipmenthas and provides objective HOUNSFIELD UNIT.It significantly differs from the color that other CT data provides.Based on this information, you can decide implant position and size and the drillingsequence for the initial stability of the implant.[BEFORE Windowing]Air[AFTER Windowing]Water-1000-500Lung0Fat 500Soft tissue 1000Bone[HOUNS-FIELD UNIT of Medical CT]R2GATETM– 317

What is R2GATE » Ⅱ. ONE-DAY IMPLANTⅡ. ONE-DAY IMPLANTTMGet your implant and prosthetics in one day!Digital EYEProvides the predictable indications for Immediate loading.According to the bone density and R2GATE treatment planning, patients can havecustomized abutments before the surgery, and it can be placed right after the implant surgery.Place a Fixture asit is plannedCompletely connect the Handpiece carrier into a fixture, and drill it down as it isplanned using your R2GATE GuideTMa. Depth of a fixture align the upper line of Handpiece Carrier with Guide Window as [Image 1]b. Matching internal hex of a fixture fill the window with the green part of a carrier body as [Image 2][Image 1]Prosthetics can bemanufactured assingle, bridge, orscrew-retained typeaccording to yourpreferences.CementationtypeScrew retainedtypeOver-Denturetype318 - Customized Abutment- PMMA Temporary- Ti-Base- PMMA CAD/CAMProvisional restoration.- Stock abutment- Customized abutment- 3D Printed Denture[Image 2]

What is R2GATE » Ⅱ. ONE-DAY IMPLANTR2GATE isalready tried andtrusted world wide.TMJapan, China, Taiwan, USA, UAE, Romania, Italy, Netherland, Australia,Germany, UK, Russia, Ukraina, TurkeyDoctors are using R2GATE through out 15 countries.30,561cases2013 2017Delivered toworld wide84,25625,173ImplantsProsthesisR2GATETM– 319

What is R2GATE » Ⅱ. ONE-DAY IMPLANTR2GATE LiteTMMeet the most innovativeimplant diagnostic software program inthe most innovative way!320

R2GATE GUIDE » Ⅰ. Advantage of R2GATE GUIDER2GATE GUIDE Ⅰ. Advantage of R2GATE GUIDEExperience the most innovative implant guide surgery!Virtual planning becomes a reality.R2GATE GUIDE doesn'tneed a metal sleeve orspoons.It has the internal-structurefor drill stopper and hexcontroller. R2GATE Guidesurgery is more convenient and precise.Precise R2GATE Guideusing 3D Printer.R2GATE guides are designed directly based on your diagnosis and are printed by3D Printer.The unique structures of R2 Guide(for drill stopper, implant position, and hex control)are printed as one-body for improved precision and convenience.R2GATETM– 321

R2GATE GUIDE » Ⅰ. Advantage of R2GATE GUIDEⅠ. Advantage of R2GATE GUIDEASTRA TECHR2GATETM integrated withMajor implant systems.NobelBiocareOSSTEMBIOMET 3iDENTIUMZIMMERDIOStraumannNEOBiotechR2GATE Surgical Kitsare available!Full Kit and Universal Kit are available.The full kit consists of a complete set of drills and system-specific implant carriers.The Universal kit consists of drills from initial to 2.8 drills for any implant systems.The implant carrier and disposable drills may be added as your option.R2GATE Full Surgical KIT322 R2GATE Universal KIT

R2GATE GUIDE » Ⅰ. Advantage of R2GATE GUIDE Simple and Practical R2GATE UNIVERSAL KITFlexible kit for all implant systemsSimple and practicalUniversal KitR2GATE Universal Kit includes essential guide drills andtools that can be used for various implant systems. Finaldrills and other necessary tools can be added for yourpreferred implant system.Add optional Tools for yourpreferred implant systemYou can add optional tools like implant carrier, tap drill,cortical bone drill and more for your preference. Refer toMegaGen Implant Catalogue for more information.We provide a newDisposable final drill for each surgery.Along with with R2GATE Guide, we provide a disposablefinal drill for ideal initial stability based on the patient'sbone density. Now, safer surgery can be done with ourdisposable final drill.* permanent drill are available under your order.R2GATETM– 323

R2GATE GUIDE » Ⅰ. Advantage of R2GATE GUIDEMust haveAccessory kitR2GATE Narrow Guide kit for Mini SystemAre you planning to use for a Mini implant? Are you worried about thesurgery because of narrow surgical space? Narrow Guide Kit withø3.5mm drill core is designed to overcome narrow surgical spacessuch as anterior mandibular, narrow distance between adjacent teethor adjacent implants.R2GATE Anchor kit For the fixation of fully edentulous guidR2GATE Anchor Kit is used to fix fully edentulous R2GATE Guide in themouth.Anchor Pin:R2GATE Anchor kitPut R2GATE Guide and Putty Bite together and put it into patient’s mouth.Let the patient bite firmly. Then, insert an anchor pin into the pin holes on theguide and fix them using a driver. If bone density is dense, Slightly drilling topenetrate cortical bone area with 2.0 x 13.0mm drill will be helpful for betterfixation.Anchor Screw:For fully edentulous guide, placing fixtures and connecting anchor screw in atriangular form is highly recommended for better fixation as the image below.When regular fixture and wide fixture are needed to place in edentulous case,there will be 2 set of R2GATE guides for regular fixture and wide fixture placement. Anchor screw will provide same position of fixation for both of R2GATEGuides.324

R2GATE GUIDE » Ⅱ. R2GATE Guided SurgeryⅡ. R2GATE Guided Surgery1. Preparations for R2GATE Guide Surgery.1Package checkTMProsthetics typeCheck what are contained in the deliverypackage received from R2GATE DesignCenter.ZA : Zirconia customized abutmentPR : Provisional restorationsPatient’s nameR2GATE Guide typeR : Regular core R2GATE Guide W : Wide core R2GATE Guide Patient’s name2Received two R2GATE Guide ?Do you plan to place a wide diameter fixture ?One is for regular diameter of drills and anotheris for wide diameter of drills & fixture insertion.RWAll diameter of general drillhole(core) and guide part of drillsare 5.0mm. So from 3.5 to 4.5diameter fixture can be placedthrough general drill hole. But Inorder to insert wide diaeter fixture(over the 5.0mm), drill hole(core)should be made for wide diameterdrilling and fixture insertion.Drilling sequence:Up to 4.3mm diameter of drilling,use the regular hole R2GATEGuide (marked “R”). Then thatchange to wide hole R2GATEGuide and continue to drill withbigger diameter drills.3Sterilization for R2GATE Guide and prosthesesPut the R2GATE Guide and all prostheticsinto a bowl (jar) with an antiseptics(ex. Chlorhexidine Gluconate) for 30 minutes beforesurgery.R2GATETM– 325

R2GATE GUIDE » Ⅱ. R2GATE Guided Surgery Types and retention of R2GATE Guide 1. Tooth - supported type1 4 implantsCusp StopDrilling CoreCusp StopThe residual teeth are stillremained around the implantation site. TheMain retention of R2GATE Guide comesfrom the remaining teeth. So, with the largernumber of remaining teeth, retention will behigher and more stable. The damage andporosity of the remaining teeth on the modelare not acceptable for the design of R2GATEGuide and its adaptation. Cusp Stop : To check the accuracy of R2GATE Guide , Designermakes a few number of “Cusp stopper” on the cusp of the mesio-distalneighbor teeth. When R2GATEGuide is seated, check its fitnessof contact between cusp and hole.There should not be a gap.[Minimum size of model] Even it’s tooth support type R2GATEGuide , 3/4 arch model is required for design and accurateretention.2. Dual - supported typeCusp StopDrilling CoreAnchorHoleStrut barFree-end caseMost of the free-endcase, R2GATE Guide gets the retentionfrom a remaining tooth and residual ridge.All anatomical forms of teeth, alveolar ridge,vestibule should be represented clearly on themodel. Anchor Hole : The anchor holecan be designed for additionalretention. The location will bedecided during diagnosis andconfirmed by user. 2.0 drillingmight be required to insert anchorpin into the hard bone. (Maxillaryanterior, Mandibulary regions).3. Fully tissue - supported typeDrilling CoreAnchorHoleFully edentulous case In the fullyedentulous case, R2GATE Guide gets thesupport from the residual ridge and gets theretention from anchor pins. All anatomicalstructure (palatal, vestibulare) should be represented clearly on the model. Putty bite : Right initial positioningof R2GATE Guide , putty bite willbe provided. Combine putty bite andR2GATE Guide first than put it in thepatient mouth together. Let the patientbite it strong and insert the anchor pininto each hole.The distortion of the model is an important factor of the error on diagnosisand R2GATE Guide . Please understand checking point of R2GATEGuide fabrication, and try to make accurate impression and model.326

R2GATE GUIDE » Ⅱ. R2GATE Guided Surgery2. Adaptation of R2GATE Guide before surgeryTMThis procedure is essential to check the accuracy of R2GATE Guide .1Tooth & tissue supportedtypeTo check the accuracy ofR2GATE Guide , our designer makes a few number of “Cusp stoppers” on the cupsof the neighboring teeth. When R2GATE Guide is seated, check its fitness betweencusp and R2GATE Guide hole. There should not be any gaps.Check the “Cusp stop” of R2GATE Guide Cusp StopCusp Stop2Fully tissue supported typePutty bite and Anchor pinFor an edentulous case, R2GATE Guide is seatedusing the putty bite and fixed with anchor pins specially designed for R2GATE Guide positioning.1. The connected R2GATE Guide and the seating jig are delivered into the mouth togetherand seated.2. Patient should bite with maximum occlusal force on the R2GATE Guide and seating jig.3. Tighten the anchor pin using a hand driver.4. 2.0mm drilling will be required in advance if the drilling point have a thick cortical bone.R2GATETM– 327

R2GATE GUIDE » Ⅱ. R2GATE Guided Surgery3. Basic principles of drilling with R2GATE GuideTMNo spoons, No sleevesOur guided drill design does not need spoons or sleevesAll of our drilling components from initial drill to implant carrier are designed as guide and drilling part.You do not need any additional sleeves or spoons, to shorter the surgery time.12345Narrow Crest Drillfor narrow or steep alveolar ridge.If a regular drill is used on narrow or steep alveolar ridgecases, a drill may slip and the drilling path will be made inthe wrong direction. In this case, use a narrow crest drill firstand flatten the drilling area to prevent slipping.How to use the Narrow Crest Drill.a. Counter-clockwise: Engage the blade onto the ridge byrotating a drill with less than 100 RPMb. Clockwise: Drill with 400 600 RPMc. Start a drilling sequence with initial drilld. You can collect bone by separating the drill body after drillinga328 bcd

R2GATE GUIDE » Ⅱ. R2GATE Guided Surgery1 & 2 DrillingstndThe 2nd drill also works as a profiler drill which removes excess bones above the fixture platform for abetter has connection of prosthetics. If bone densityis dense or high resistance during drilling, stop 2nddrilling protocol and repeat 2nd drilling protocol rightbefore fixture placement.322.25Ø2.5Initial Drill2nd DrillØ4.6Crucial Step: Basic drillingNarrow Ø2.0 diameter drilling is very important tocomplete the coronal path of the drill. Especially whenthe guide core is short due to thick gingiva, gradualdrilling to secure the depth of a fixture is essential forsuccessful surgery.Eg) When placing a 11.5mm length fixtureNarrow drill initial Drill 2nd drill 2.0x7 2.0x8.5 2.0x10 2.0x11.5 2.5x11.5 2.8x11.5 Final drill Cortical bone ow drilling in a Drill CoreBefore drilling, you have to check the guide part of dirll tobe inserted into the drill core of guide compeletely. whendrill is in right postion, start drilling with recommendedRPM [300 500 RPM]Slow UP & DOWN MotionDrilling must be done in the order of increasing the depthof osteotomy and then widening the diameter accordingto the suggested drilling protocol. Keep repeating up anddown motion slowly until the drill stopper touches thestopper position on the guide.XO OR2GATETM– 329

R2GATE GUIDE » Ⅱ. R2GATE Guided SurgeryDeliver Fixture as plannedMake sure to connect Handpiece Carrier onto afixture and deliver it through the R2GATE Guide asplanned.a. Fixture depth controlAlign the upper line of the Handpiece Carrier with theGuide Window as [Image 1]b. Hex position controlAlign the green part of Handpiece Carrier as [Image 2][Image 1][Image 2]to make hex position in buccal direction.We provide a general standard for immediate loading [ISQ & ITV]If you use AnyRidge System, the recommended ITV (Initial Torque Value) and ISQ (Implant StabilityQuotient) for immediate loading are ITV 45Ncm/ISQ 75 or above. These values are only for theAnyRidge system and cannot be applied to other systems.Full arch restoration: Cross arch sprinting6065Multiple restoration: Splinting70Single restoration75ISQBonefractureLoose ofconical boneengagementApplicable to AnyRidge System onlyInitial Torque valueITV10330 2530354045 80

R2GATE GUIDE » Ⅱ. R2GATE Guided Surgery4. Recommended condition for ONE-DAY IMPLANT& immediate loadingAccording to our own clinical experiences & data, we strongly recommend tocheck two values : Insertion Torque & ISQ value.1Insertion Torque value :more than 45NcmAvailable on our R2GATE Universal Kit.2ISQ value:more than 75 ISQ valueR2GATE Digital CenterTo have stable ISQ value, we recommend to use MEG-TORQto fasten a smartpeg with 5 Ncm torque force consistently.rpm5R2GATETM– 331

R2 Digital Center » Ⅰ. Various R2GATE ServicesThe R2 Digital Centers are close to youThe most important thing iswhom you work with!332

R2 Digital Center » Ⅰ. Various R2GATE ServicesR2 Digital CenterⅠ. Various R2GATE ServicesWe provide various R2GATE Services. Enjoy them conveniently.R2GATE Planning ServiceTMOptimal Implantpositioning basis on theTOP-Down concept.R2GATE allows you to do Prostheticdriven Treatment Planning for optimalpositioning of the implant. It providesan eidetic view of all elements that youneed for implant practice as CBCT,STL, and Prosthetic design beforesurgeryR2GATE Guided ServiceTMRealize the Tx.planningperfectly.The surgical guide will be made usingstate of the art 3D printing technologywith the result of Tx.planning. R2 Guidecompletes your daily implant practicewithout uncertainty.R2GATETMONE-DAY IMPLANT service. Under certain conditions, variousprostheses may be delivered on thesame day as surgery. Recover function& aesthetics immediately!R2GATETM– 333

R2 Digital Center » Ⅱ. R2GATE Order processⅡ. R2GATE Order processTMOrderImplant Planning12CBCTCASTCBCT TakingModel ScanModel fabrication.Digital wax-upSend it to R2 Center.Implant planningSend planning file back to ClinicCaution!Ask R2 Tray to localR2 Digital Center before placingan orderIf a patient is partially edentulous or if there are multiple teeth withmetal fillings or restorations, R2 Tray must be used. R2 tray mustbe sent to R2 Digital Center along with study models and biteregistration.334

R2 Digital Center » Ⅱ. R2GATE Order processSimple order process : R2GATE Service is very simple,fast and cost effective.We have world-wide R2 Digital Center network. Please contact to nearest Digital Centeror MegaGen distributors at applicable countries.User ConfirmationManufacturing34Delivery5Download project file to R2GATE LiteR2 Guide DesignPackagingOpen project file.3D Printing & trimmingDeliveryModification or confirmationCAD/CAMYour confirmation is themost important to shortenthe delivery time.Diagnostic information sent to R2GATE lite can be confirmed.Corrected and approved data are savedas project files and transferred to the R2 Digital CenterR2GATE Lite is the essential option for you.R2GATETM– 335

R2 Digital Center » Ⅲ. R2 Digital Center NetworkⅢ. R2 Digital Center NetworkPlease find the nearest R2 Digital Center from your country.R2 Digital Center HQMegaGEN Co.,Ltd, SOUTH KOREA45, Secheon-ro 7-gil, Dasa-eup,Dalseong-gun, Daegu, Republic of KoreaTEL : 82-70-4352-1120FAX : 82-70-7469-1120E-MAIL : r2gate@gmail.comR2 Russia CenterDENTAL GURU, RUSSIABld 43/2, Pokrovka Str. Moscow,105062, RussiaTEL : 7-92-6526-2697E-MAIL : sedov135@gmail.comR2 Germany centerMegagen F.D. AGGermany, JengenZiegeleistrasse 18, 86860 JengenGermanyTel : 49(151)173-665-97E-mail : thomas.halm@imegagen.deR2 Japan CenterJOHNNY'S CORPORATIONAssorti Honmachi Bld. 8F, 2-3-4 Honmachi, Chuo-ku, Osaka-shi, Osaka541-0053 JapanTel: 81 6 6710 9188E-MAIL : factory@johnny-s.comR2 Turkey CenterSOLIDENTAL LTD.TURKEYISTANBUL Mecidiyeköy BüyükderCad. No:99 D:7TEL : 90-21-2211-3932R2 UAE CenterAl Najah Technology LabUAE, AbuDhabi-Hamdar str. Office 303Tel.: 009 7150 977 0009Fax: 009 712 6266 356E-mail: info@alnajah-idl.net336

R2 Digital Center » Ⅲ. R2 Digital Center NetworkR2 Romania CenterSC DDX EUROPA SRLROMANIAStr Ion Voinescu, nr 12,, Postal Code31096 Sector 3, Bucuresti ,RomaniaTEL : 4-0784-709-496E-MAIL : office@r2eucenter.comR2 Australia CenterMegaGEN AustraliaAustraliaUnit 1, 233 Greenhill road Dulwich SA5065, AdelaideTEL : 61 8 8331 2257E-MAIL : ausmegagen@gmail.comR2 Canada CenterChrysalis Dental LabCanada, British Columbia406-4603 Kingsway Burnaby,BC V5H 4M4Tel : 1(604)439-8885E-mail : drkwon@biteinstitute.comR2 USA Center(NJ)R2 Digital LaboratoryUSA, NJ185 Bridge Plaza North Suite 2,Fort Lee NJ 07024Tel.: 1 (877)668-9151E-mail: proskang@gmail.comweb: www.r2digitallab.comR2 USA Center(CA)Universal orthodonticUSA, CA11917 Front ST, NorwalkCA 09650Tel : 1(562)484-0700E-mail : paulkim@usortho.comR2 Benelux centerMegagen Benelux, NetherlandsNetherlands, OisterwijkLaarakkerweg 8, 5061JRTel : 31-88-84-84-100E-mail : r2gate@megage.nlR2 Iran CenterSaba dentIRAN, TehranTel : 98-91-2022-6286E-mail : kazem@gmail.comR2 Estonia CenterProimplant OÜEstonia, TallinnTüri 10c, Tallinn, Estonia 11313Tel : 372-526-9113E-mail : kait@proimplant.eeR2 Kyrgyzstan CenterUnlim TradeKyrgyzstan, Bishkek720005, Abay street 48/2Tel : 996-555-880066E-mail : maggotmax@mail.ruR2 Ukraine CenterDent LineUkraine, NikolaevGusev Vladimir karpeka 2/1, 157 app,Nikolaevskaya oblastTel : 380-509-677-953E-mail : v888ww@gmail.comR2 UK centerMegagen UKUnited Kingdom, Bedfordshire110 butterfield, Great marlings,Luton, Bedfordshire LU2 8DLTel : 44 (0) 1582-439-771E-mail : dima.corduneanu@megagen.co.ukR2GATETM– 337

R2 Digital Center » Ⅳ. R2GATE Business OpportunityR2 BusinessOpportunityAnyone can become a R2 Digital Center!R2 Digital Center provides High-end digital solution.338

R2 Digital Center » Ⅳ. R2GATE Business OpportunityⅣ. R2GATE Business OpportunityJoin the R2 Digital Center!Become a leader in digital dentistry.R2GATETMis already tried andtrusted world wide!R2GATE is an innovativeimplant diagnostic softwarethat analyses the oral condition and it shows best option for implant treatment.2013 2017R2GATETMOptimal Implantpositioning basis on theTOP-Down concept.R2GATE allows you to doProsthetic driven Treatment planning for optimalpositioning of the implant. Itprovides an eidetic view of allelements that you need forimplant practice as CBCT,STL and Prosthetic designbefore surgeryR2GATETMR2GATETMRealize the Tx.planningperfectly.ONE-DAY IMPLANTservice.The surgical guide will bemade using state of the art3D printing technology withthe result of Tx.planning.R2 Guide completes yourdaily implant practice withoutuncertainty.Under certain conditions,various prostheses may bedelivered on the same dayfor surgery. Recover function& aesthetics immediately!38,061casesDelivered toworld wide84,256Implants25,173ProsthesisR2GATETM– 339

R2 Digital Center » Ⅳ. R2GATE Business Opportunity“Our goal is to gather2,500 R2 Digital Center in the World!”R2 Digital Centers will be expanded worldwide from the United States and Europe to the MiddleEast and across Asia.All dentists anywhere in the world will be able to conduct guided surgery using our R2 Serviceregardless of their implant system.Our primary strategy is to make multiple labs in every country use our digital services so that we candominate the broad and unlimited global Guided Surgery market.We believe that expanding our digital service will increase the name value of the R2GATE &MegaGen brand and of course the number of implant users.North AmericaSouth America340 EUROPEAfricaRussia / CISMiddle EastEast AsiaSouth Asia

R2 Digital Center » Ⅳ. R2GATE Business OpportunityR2GATEproves itself with clinical casesTM38,061 cases/84,256 implantsVisit our website www.r2gate.com and go toFacebook or Youtube for various clinical videos.R2GATETM– 341

R2 Digital Center » Ⅳ. R2GATE Business OpportunityMinimal equipment requirementsfor R2 Digital Center?R2GATE PCFor smooth operating,Hight-End PC (window only)it is essential.OSOperating SystemCPUCentral Processing UnitGPUGraphic Processing UnitResolutionDisplay ResoltionMemoryInstralled MemoryIntel Core( ) i7-6700 CPU @ 4.00GHz or aboveGeForce GTX 960 aboveGraphic memory 2G above1920 x 1080Hight resolution Monitor (1680 x 1050 minimum)8 GB aboveDisk500 GB aboveNetworkLAN or WifiInstalled Driveenabled networking342 Microsoft Windows 10 ProOS: Microsoft Windows 7 64bit above (Latest updated)

R2 Digital Center » Ⅳ. R2GATE Business OpportunityModel ScannerAny Model (Desktop) scanner that extractsSTL files are suitable.The 3shape scanner is also suitable, but itrequires additional converting software thatconverts DCM to STL file.DCM file can be converted to STL through EXOCAD.3D PrinterAny 3D Printers can be used except FDM printer.Minimum Building size should be over 100 x 70mm.To use your printer you have to test it with our design file first.Our Meg Printer II is made for R2GATE guides and temporary crownsIf you consider to purchase a new printer, please put it on your check list.Meg Printer IIMilling MachineYou can use your CAD/CAM machines.Five axis machine is highly recommended for ONE-DAY IMPLANT prostheses.MegaGEN launched these cost effective CAM/CAM milling machines as well.Please put our equipment on your check list if you are considering to purchase a New CAD/CAM Machine. Dual Jig Holder Auto support cutting 3 Pre-milled abutment loadingTiGEN AbutmentZIRCONIAPMMAR2GATETM– 343

R2 Digital Center » Ⅳ. R2GATE Business OpportunitySTEPSubscriptionProcedureSTEP1Sign upSTEP24EducationSTEP3ApprovalPaymentPlease refer to PAGE 521, R2 Digital center application form / Terms and conditions344

R2 Digital Center » Ⅳ. R2GATE Business OpportunityR2 Digital CenterActivation Fee 5,000 USDWe will provide the R2GATE solutions to R2 Digital Centerwith the minimum integration fee.Intensive EducationWe will provide full education to the candidate from planning to design and manufacturing process forR2 Guide business.R2GATE softwareR2 Digital Center can download it from our website and use it without limitation of copies.On-line order systemThe R2 Digital Center can access our "online order system" and integrate it with their own business.It provides all CS solutions through SMS, E-mail service to all customers to track their order process.R2 Digital Center system integrationR2 Surgical Kit [Select prefer system]R2 Guide Trimming Tool setOSSTEMStraumannNobel BiocareBIOMET 3iASTRA TECH5days/ 4nights (Starts every Monday) programContinuing education if necessaryR2 Standard surgical Kit1setR2GATETM– 345

R2 Digital Center » Ⅳ. R2GATE Business OpportunityIntensive Training for R2 Digital CenterAfter education, each member of R2 Digital Center will be able to do merging process& R2GATE GUIDE design by themselves.You can attend our continuing education course every time to update skills andknow-how.Day1TrainingIntroductionIntroduction to R2GATE andPreparation for R2GATE Part Ipreparation for workPreparation for R2GATE Part II(Theory / Practice)R2GATE Program Basic2R2GATE S/W Practice IR2GATE S/W Practice IIR2GATE Intensive III3346 DetailsWeb order systemR2 Guide design IHow to use R2GATE Softwarecase-based practiceTip & knowhow for Tx.planningR2 Guide design and practiceR2 Guide Design IIR2 Guide design practice4R2 Guide Printing3D printing practice and post-R2 Post-processingprocessing.5Work Flow ReviewTraining & workflow reviewQ&AHourResult·Understand the basic principles of R2GATE.8h· Understanding CBCT data and How to Scanthe model for R2GATE.·Basic operation of R2GATE S/W8h· Mastery through practical case progressionexercise.8h8h4h·R2GATE case practice·R2 Guide design and practice.·R2 Guide design for full arch case·Finishing & Trimming of R2 Guide·Overall process review·Q&A

R2 Digital Center » Ⅳ. R2GATE Business OpportunityR2GATETM– 347

R2 Digital Center » Ⅳ. R2GATE Business OpportunityCase fee only!Maximize Your profit!Just share a tiny portion of your income from a Client.After education, your team will be able to do merging process & R2GUIDE design by themselves.But if you require specialist's service, our specialists will help you with minimum points.CBCT & ModelInitial Tx.Planning12Precise matchingDiaginosis1P1P/per caseR2 Digital Center ,Welcome promotion!Double points1 1 50%Launching Event !Purchase 500 point and get 500 points more! ( 2017. 12. 31)R2GATE PointR2GATE Lite License 10.0 (KRW 10,000) 300Instantly activatedafter payment.Launching Event !purchase 500 point andget 1000!( 2017. 12. 31)·R2GATE STL Extraction.·Available for matching and designservice. 100Activation Code.1 license for 1 copy.Special promotionuntil 2017.R2 Digital CenterBilling PolicyR2 Digital Center can purchase the“Point” through on-line mall www.r2gate.com.There will be attempting promotion regularly.·R2GATE Lite activation code.·Automatically upgrade.·Submit the code after installation.www.r2gate.com348 /per case

R2 Digital Center » Ⅳ. R2GATE Business Opportunity4Pper case (regardless of the number of implants)STL Extraction (Automatic deduction of point)Confirmation3D printingDeliverySTL Extraction345Guide design1P/per implant① MEGAGEN shall charge each R2 Digital Center a fee for using the R2GATE program on a pay-per-use basis.The pay-per-use fee shall be “4 Points” per case (regardless of the number of implants)② The fee shall be paid in prepaid points (“Points”) and each R2 Digital Center may use desired services afterpurchasing the points based on the desired number of cases or services.③ Points shall be automatically deducted from the user’s account based on the service usage detailsof R2 DIGITAL CENTER.④ The table below represents the description of services and discount points provided to each R2 Digital Center.HQ ServiceDeductible pointsTiming of deductionRemarksCase fee4 pointsUpon STL extractionAutomatically deductedMerging services1 pointsUpon provision of project fileAutomatically deductedGuide design services1 point (Per implant)Upon provision of guide design file (STL)Automatically deductedR2GATETM– 349

R2 Digital Center » Ⅳ. R2GATE Business OpportunitySupport for R2 Digital CenterYou can access it in 24 hoursOn-line order systemThe R2 Digital center can access our "online order system" and integrate it with their own business.It provides all CS solutions as SMS and E-mail service to all customers tracking their order process.On-line marketThe R2 Digital center can access our membership on-line market and purchase everything theyneeded for R2 Guide business with cost-effective price.R2 Digital Center ,Welcome promotion!Double points1 1 50%Launching Event !Purchase 500 point a

MegaGen Implant Catalogue for more information. Full Kit and Universal Kit are available. The full kit consists of a complete set of drills and system-specific implant carriers. The Universal kit consists of drills from initial to 2.8 drills for any implant systems. The implant carrier and disposable drills may be added as your option.