BDBDOUBLE INLETCENTRIFUGAL FANwith Backward Wheels

BDB SeriesDOUBLE INLET CENTRIFUGAL FAN with Backward WheelsKruger Ventilation Industries Asia Co.,L td certifies that theseries shown herein is licensed to bear the AMCASeal. The ratings shown are based on tests andprocedures performed in accordance with AMCAPublication 211 and AMCA Publication 311 and complywith the requirements of the AMCA Certified RatingsProgram.

BDB SeriesDouble Inlet Centrifugal Fans – Backward wheelsThe BDB series is DIDW centrifugal fans with high efficiency non-overloading backward curved impellers.The fans are suitable for supply or exhaust applications in commercial, process and industrial HVAC systems.Sizes of this series are in accordance with AMCA standard 99-0098-76 R20.Type / Operating LimitEach fan type has its maximum operating speed and power due to its mechanical design.The operating limit of different fan types of BDB series is set according to the requirement of class I, II andIII limit as defined in AMCA standard 99-2408-69.The BDB series is available in type S, C, T, X or Z.Model 315 to 710Type S-CIModel 800 to 1400Type TIIIModel 1600 to 2000Type XIIIIIIIIIIIIIType ZType SThis type is supplied with mounting feet and can be mounted in three different orientations.The construction is mainly for OEM application which is subject to testing and approval.Fan Size : 315 to 710Volume : 1900 to 50000 m3/hTotal Pressure : up to 2000 PaType CThis type has frames fitted on both sides of the fan, providing better strength and rigidity.It allows mounting in four different orientations.Fan Size : 315 to 710Volume : 1900 to 50000 m3/hTotal Pressure : up to 2000 PaType TThis type has a welded frame, giving increased stiffness and rigidity required for higheroperating performance.Fan Size : 315 to 1400Volume : 1900 to 190 000 m3/hTotal Pressure : up to 2500 PaType X/ZThe structure is similar to type T but utilizes enhanced bearings to support higher dynamicload necessary for the increased performance.Fan Size : 315 to 2000Volume : 1900 to 680 000 m3/hTotal Pressure : up to 4500 PaType Z is non-standard, for more information, please consult your nearest Kruger Office fordetails.

BDB Twin FanBDB series is also available in twin fan version, with two double inlet fans mounted on the same shaft.To select twin fans, use the curves of single fan with the following factors:VolumeAbsorbed PowerSpeedNoisex2x 2.15x 1.05 3 dBThis series is available in type S2, C2 or T2Performance of Twin fans is not AMCA licensed.Type S2Type C2Size: 315 to 500Vol.: 5000 to 50000m3/hSize: 315 to 500Vol.: 5000 to 50000m3/hType T2Size: 355 to 630Vol.: 10000 to 80000m3/hTECHNICAL SPECIFICATIONWheelThe wheel of BDB series is made of cold rolled sheet steel backward curvedblades with polyester powder coating finish.HousingFor all sizes except 1250 and above, the housing is manufactured ingalvanized sheet steel with the housing fixed to the side plates in "pittsburglock" form system.Housings for 1250 and 2000 are manufactured in mild steel finished withpolyester powder coating finish.Fully welded steel plate housings with painted finish are available for all sizeupon request.FrameThe frame is manufactured with galvanized angular bars for type "C". Fortype "T" and "X", they are manufactured with sections of steel with polyesterpowder coating finish.ShaftShafts are manufactured from C45 carbon steel using an automatic processfor positioning and cutting of the keyways. All dimensional tolerances of theshaft are fully checked to ensure a precise fit. All shafts are then coated withan anti-corrosion varnish after assembly.

BearingsBearings used are either deep groove ball bearing with an adaptorsleeve or spherical roller bearings sealed at both sides for different dutyapplication and are classified as below:Fan TypeMounted in a rubber housingSBearing DutySMeg.TCMedium DutyModel: BDB 450CMMounted on cast iron supports with grease pointMedium DutyCMTMTXXMedium DutyExtra HeavyXMXXMedium DutyExtra HeavyFan Bearing Duty (L, M, X)Fan Type (S, C, T, X, Z)Fan Size(315, 355, 400 1400)Except TX, XX, UX extra heavy duty bearings, all bearingsare lubricated for life and maintenance-free. If re-lubricationis necessary, it is recommended to use a lithium base greasesuitable for all temperatures within the operational limits.Balancing QualityAll wheels are statically and dynamically balanced toISO1940 and AMCA 204 – G2.5 standard.All fans after assembly are trim-balanced to ISO1940 andAMCA 204 - G2.5 standard.Clean room application fans with balancing grade of G1.0are available upon request.ACCESSORIESCasing DrainThis option is available when fans are exposed to theatmosphere or operating in high humidity condition.P3Outlet FlangesOutlet flanges are available upon request.P4Inspection DoorsThe inspection door can be supplied upon request. It canbe supplied in one of the three positions (P3, P4 & P5).GuardsP5Inlet guards, discharge guards and non-drive end shaftguards are available on request.

Fan Rotation and DischargeThe rotation and discharge of the fan is in accordance with AMCA standard 99-2406-83.The direction of rotation is determined from the drive side of the fan:CW - clockwise rotationCW90CW180CCW - counter-clockwise rotationCW270CW360CCW90CCW180CCW270CCW360Motor PositionThe position of the motor for belt drive centrifugal fan is inaccordance with AMCA standard 99-2407-66.WLocation of motor is determined by facing the drive side of fan anddesignated by letters W, X, Y, or Z.ZXY100Motor Selection60The power curves shown on eachperformance graph represent the absorbedpower at the shaft of the fan measured in kW.403020To determine the power of the motor to beinstalled, a correction factor should be appliedto compensate for transmission losses.151082 Pole64 & 6 PoleFor conversion to horsepower (HP), usemultiplying factor 60.750.310.451.50.2Correction Factor, % motor power output80Motor power output (kW)Inlet Vane ControlThe inlet vane control enables energy saving that varies according to the vane controlmethods compared to traditional volume control methods.Fig.1 shows the volume reduction corresponding to the vane position.- with vane fully open (Pos 90 )the volume will be 3% less than the catalogue performance.- with vane fully closed (Pos 0 )the volume will be reduced by 75%.Performance of Inlet vane control is not AMCA licensed.

IVC orientation and accessoriesThe standard orientation and lever position for the IVC is indicated inFig.2. When ordering a complete fan with IVC and accessories, pleasespecify as follow:Fan orientation e.g. CCW270lever position e.g. Pos. 45oExample : Fan Model – CCW270/P45Fig. 1Orientation90IVC LevelPosition180270360225 315 45 135 315 45 135 225 Fig. 2 - IVC Orientation and Level PositionDynamic PressureBoth dynamic pressure and outlet air velocity values shown on each graph are calculated base on the full discharge area, i.e.ducted outlet condition.With free outlet condition the velocity pressure is higher. To determine this new value multiply the velocity pressure ofthe ducted outlet obtained from the fan curve by the following correction factor “K”.K 1.67Fan performance calculated with this correction factor is not licensed by AMCA.PerformanceThe performance data shown on each graph is derived from tests conducted in accordance to AMCA Standard 210 –Fig 12 – installation type B (free inlet and ducted outlet condition).Ratings refer to the standard air density with the total pressure as a function of the air volume, using logarithmic scale.It is essential that the same installation type and test standards are used at all times when comparing fan performance.NoiseThe noise levels shown on each graph refer to the "A-weighted" sound power values and the data on the inlet sidehas been measured in accordance with AMCA Standard 300 diag. 2 - configuration "B". The noise levels of fans aredetermined as follow :Sound power level - ("A" scale): Lw (A) as catalogueOctave band spectrum: Lw Lw(A) Lw rel. dB [refer to Kruger for more details]Sound pressure level:a)free field Lw(A) - (20log10d) -11b)room conditions Lw(A) - (20log10d) -8where d distance from fan (m)

PerformanceThe performance data shown on each diagram is derived from testsconducted in accordance to AMCA Standard 210- Fig 12- Installation typeB (free inlet and duct outlet condition).Ratings refer to standard air density with the total pressure as a functionof the air volume, using logarithmic scale.It is essential that the same installation type and test standards are usedat all time when comparing fan performance.According to AMCA 205, BDB series can be classify as FEG 85 90 basedon fan peak efficiency. The following is the explanation of FEGclassification:1.2.3.4.5.6.7.8.Fan size is the impeller diameter in mm.The fan peak efficiency shall be calculated from the fan (total)pressure.If this method is used for a direct driven fan, the fan efficiency is theimpeller efficiency.The FEG label for a given fan size is assigned when the fan peakefficiency is equal to or lower than the efficiency at the grade upperlimit, and higher than the efficiency at the grade upper limit of thenext lower grade for the fan size.For any fan sizes larger than 1016 mm, the values of the grade upperlimits are the same as for a size of 1016 mm.No labels are considered for the fans with the fan peak totalefficiency below FEG 50.The values of efficiencies are calculated for fan sizes in the preferredR40 Series.Not all available fan sizes are shown.Fan Efficiency Grades (FEG) for Fans without Drives (SI) – AMCA 205

Example of SelectionAir VolumeQ 14760 m3/hOutlet VelocityV 10.07 m/sDynamic PressurePd 62 PaTotal PressurePt 1515 PaFan SpeedN 1900 rpmAbsorbed PowerW 8 kWTotal Efficiencyη 78 %Sound Power LevelLw(A) 90.3 dB(A)

BDB 315-400 ‘S’Gh3LEMDCh2Mh1AØd-g6uxsJKFB 06506355290546586726110302462359303011x16All Dimensions in mm.BDB 450-710 ‘S’Gh3LEMDCh2Mh1AØd-g6FuxsJKFB 5013x18All Dimensions in mm.

BDB 315-400 ‘C’ModelBDB 450-710 ‘C’Model

BDB 315-400 ‘T’BLGE MDC RMFAØd-g6 uxsF P JKH 061254658677293385353513x18All Dimensions in mm.BDB 450-1000 ‘T’BLGE MDCF RMuxs FAF1Ød-g6 FPFF1 JKH 101302 2800146812548621006 1006405171540118010561106 1388141747555517x22900164814089711130 1130455189604131911801230 1566168897606017X22100018101540 1066 1266 1266500200656145013161366 1724179909607017x22All Dimensions in mm.28

BDB 1120-1400 ‘T’BLGE NDC FRM AØd-g6F uxsF P FJKH dModelABCDEFGHJKLMNPRTLTMuxs11202033 1725 1200 1422 14222907481630 1482 1548 180019359959-7517x2212502285 1930 1353 1524 15243008301831 1599 1674 197522081999-8017x2214002568 2170 1515 1794 17943109632057 1869 1944 22602278911313-8017x22All Dimensions in mm.

BDB 315-400 ‘XM’BLG E MDC RMFAØd-g6 uxsF P JKHModelABCDEFGHJKLMPR 8All Dimensions in mm.BDB 450-1000 ‘XM’BLGE MDCF RMuxs FAF1Ød-g6 FPF1F JKHModelABCDEFF1GHJKLMPR 1540118010561106 1911801230 16602158977017X22100018101540 106612661266500200656145013161366 1845239.59098017x22All Dimensions in mm.30

WheelOperational Limits - "BDB"

Centrifugal Fan Ordering InformationFan Details Fan typeDIDW Impeller typeForward CurvedBackward CurvedOthers : (Please State) Model & size e.g. FSA 560 CModel : (If known) Drive type - belt, direct,coupling (if differ from standard)BeltDirectCouplingOthers : (Please State) Arrangement (1 & 3 for bare shaft fan; 4, 8 & 12 forcomplete with drive system)Bare fanComplete with drive system Rotation & Discharge e.g. CCW 270CW90180CCW270360WXYZ Motor position (refer to diagram) e.g. W Air Flow RateSISWQ :L/Sm3/hm3/mincfm Pressure (static & total)SP :TP :inWGPammH2O Fan RPM (if specified)Max. :Min. : Noise leveldBdBALw :Lp : at Distance : mfree fieldroom conditioncorner / wall Ambient temperatureTemp. Air density, if differ from standardDensity : kg/m3Altitude : m: CMotor Details44m3/sFittings Detail PowerkW :HP : No. of Poles /RPM2P4P6P8POthers :(pls state RPM) Voltage220V380V400V Phase1φ3φ AccessoriesInspection doorDrain plugFlexible ductInlet vane controlVibration Isolators:RubberFloor-mount415V440VOthers :SpringCeiling-hangSilencers :With podWithout podInletOutletBoth inlet & outletCounter-flanges :FlatL-typeInletOutlet Frequecy50 Hz60 Hz Frame sizeIEC :NEMA :Others : Make, if specifiedBrand :Mfr. :Country :U-typeSpecial Features OtherRequirementsPaintingPowder coatingHot-dipped resistant, temp. CSmoke Spill,Max. temp. C for Hr

KRUGERGROUP(VENTILATION) THAILAND (Regional HQ) AUSTRALIAKRUGER VENTILATION INDUSTRIES ASIA CO. LTD.S&P-KRUGER AUSTRALIA PTY LTD30/159 Moo 1, Sinsakorn Industrial Estate,Chetsadawithi Road, Khok Kham Mueng, Samuthsakorn 74000, ThailandTel. 662 1054298 - Fax 662 0248256-9Website: www.krugerfan.com2 Cunningham St, Moorebank N.S.W. 2170Tel. 61 2-98227747Fax. 61 2-98227757Email: info@sandpkruger.com.au CHINA (BEIJING) CHINA (GUANGZHOU)BEIJING KRUGER VENTILATION CO. LTDGUANGZHOU KRUGER VENTILATION CO. LTDLevel 7, A Block, Rising International Building, 29 JingHai San Road, BDA,Beijing, P.R.China 100176Tel. 86 10-67881366 - Fax 86 10-67880566Email: krugertj@krugertj.comNo. 9 Huahui Road, Huashan, Huadu,Guangzhou, P.R. China 510880Tel. 86 20-66356635 - Fax 86 20-86786001/86786500Email: gzkruger@krugergz.com CHINA (SHANGHAI) CHINA (TIANJIN)SHANGHAI KRUGER VENTILATION CO. LTDTIANJIN KRUGER VENTILATION CO. LTD CHINA (WUHAN) DUBAIWUHAN KRUGER VENTILATION CO. LTDKRUGER VENTILATION INDUSTRIES, GULF BRANCHNo. 500 Yuanguo Road, Anting, Jiading,Shanghai 201814 P.R. ChinaTel. 86 21-69573266 - Fax 86 21-69573296Email: shkruger@krugerchina.comNo.168 Anyuan Road, Jingjin Science and Technology ParkWuqing District, Tianjin, ChinaTel. 86 22-22143480/3481 - Fax 86 22-22143482Email: krugertj@krugertj.comNo. 805, Huian Ave, Dongxihu District, Wuhan, Hubei, P.R. China 430000Tel. 86 27- 83248840/83060522/83097505Fax 86 27- 83261886Email: whkruger@krugerwh.comJebel Ali Free Zone Area (JAFZA) P.O. Box No. 262949, Dubai, UAETel. 971 4 8819188/8832017Fax. 971 4 8832018Email: johncs@krugerasia.com HONG KONG INDIAKRUGER VENTILATION (HONG KONG) LIMITEDKRUGER VENTILATION INDUSTRIES (INDIA) PVT LTDFlat C, 9/F, Yeung Yiu Chung (No.8) Industrial Building,20 Wang Hoi Road, Kowloon Bay, Kowloon, Hong KongTel. 852 22469182 - Fax 852 22469187Email: info@kruger.com.hkKruger Centre, Mumbai-Nasik Highway,Kalamgaon, Shahapur, Thane 421601, Maharashtra, IndiaTel. 91 9960558899/9975577211 - Fax 91 2527 240075Email: sales@krugerindia.com INDIA (NORTH) INDONESIAKRUGER VENTILATION INDUSTRIES (NORTH INDIA) PVT LTDP.T. KRUGER VENTILATION INDONESIA KOREA MALAYSIANEOMATE CO. LTDKRUVENT INDUSTRIES (M) SDN BHD MYANMAR PHILIPPINESKRUGER VENTILATION (MYANMAR) CO.LTDKRUGER M&E INDUSTRIES CORPORATIONPlot No. - 191, Sector - 59, Ballabgarh, Faridabad - 121 004, Haryana, IndiaTel. 91-9958991660/9717449696Fax. 91-1294135820Email: sales.kni@krugerindia.com2-1010, Ace High Tech City B/D, 775 Gyeongin-ro,Yeongdeungpo-gu, Seoul, Korea. Postal Code 07299Tel. 82-2-2679-2052 - Fax. 82-2-2679-2174Email: y7890@neomate.co.krJL. Teuku Umar No.20,Karawaci - Tangerang 15115, IndonesiaTel. 62 21-5512288/5513557 - Fax 62 21-5513502Email: mktg@krugerindo.co.idLot 850, Jalan Subang 7, Taman Perindustrian Subang,47500, Subang Jaya, Selangor D.E.Tel. 603 80743399 - Fax 603 80743388Email: mktg@kruger.com.myRoom No. F21, Thiri Yadanar Whole Sale Market, (Htawunbe)Toe Chae Ward, North Okkalapa Township, Yangon.Tel. 959 763141081/2/3Email: htoon@krugermm.comFAPI Compound, E. Rodriguez Ave.Tunasan, Muntinlupa City 1773, PhilippinesTel. 63 2-8622892/4/6/7, 5534059 - Fax 63 2-8622891Email: mktg@krugerph.net SINGAPORE TAIPEIKRUGER ENGINEERING PTE LTDKRUGER VENTILATION (TAIWAN) CO. LTDNo. 10 Buroh Street #06-06, West Connect Building,Singapore 627564Tel. 65 68631191 - Fax 65 68631151Email: mktg@krugerasia.comNo. 157, Ping-an Rd, Hengfeng Village,Dayuan Shiang Taoyuan County 337, TaiwanTel. 886 3-3859119 - Fax 886 3-3859118Email: sales@krugertwn.com.tw THAILAND VIETNAMKRUGER VENTILATION IND. (THAILAND) CO. LTDKRUGER VENTILATION INDUSTRIES (VIETNAM) CO. LTD30/105 Moo 1, Sinsakorn Industrial Estate,Chetsadawithi Road, Khok Kham Mueng, Samuthsakorn 74000, ThailandTel. 662 1050399 - Fax 662 1050370-2Email: mktg@kruger.co.thLot A7. 2-4, C2 Road, Thanh Thanh Cong IZ,Trang Bang Dist. Tay Ninh Province, VietnamTel. 84-276 3585200/01/02 - Fax 84-276 3585199Email: mktg@krugervn.comThe company is always improving and developing its products, therefore the company reserves the right of making changes to the illustrated products.Certified dimension can be provided upon request.Edition 5Ð ·² »¼ ·² Ö¿²«¿ § îðïè

Kruger Ventilation Industries Asia Co., Ltd30/159 Moo 1, Sinsakorn Industrial EstateChetsadawithi Road, Khok Kham Mueng,Samuthsakorn 74000, ThailandTel. 662 1054298 - Fax. 662 0248256-9Website:www.krugerfan.comCNo. - CAT008 .E4January 2018

BDB Series Double Inlet Centrifugal Fans - Backward wheels The BDB series is DIDW centrifugal fans with high efficiency non-overloading backward curved impellers. The fans are suitable for supply or exhaust applications in commercial, process and industrial HVAC systems. Sizes of this series are in accordance with AMCA standard 99-0098-76 R20.