Restek GC AccessoriesGC Inlet Maintenance:Restek’s Quick-Reference Guide Help ensure quality data by selecting the right GC inlet supplies. Prevent unwanted downtime with a preventative GC inletmaintenance program. Easily order the GC inlet supplies you need foryour specific instrument.www.restek.com/GCacc

GC Inlet Maintenance:Restek’s Quick-Reference GuideLiners, septa, inlet seals. when compared to your analytical column, your instrument, or a customerlost due to missed deadlines or inaccurate data, these small consumables carry an almost nonexistentprice. And yet, the impact they can have on your analysis—not to mention your livelihood—is huge:breakdown of active compounds, loss in response, and other performance issues. In extreme cases,improperly selected or poorly maintained inlet supplies can mean the difference between detectingyour compounds or not.With Restek’s guidance and our comprehensive line of high-quality GC inlet supplies, performingproper GC inlet maintenance to help maximize your lab’s uptime and ensure accurate, reproducibledata is as easy as replacing a liner (and a few other items).2www.restek.com/GCacc

Selecting the Right GC Inlet SuppliesUsing the wrong liner or septa can have just as negative an impact on your data as a fouled inlet. So, even ifyou are a seasoned GC veteran, it pays to take the time to be sure that you are using the right GC inlet supplies before worrying about how or when to perform GC inlet maintenance.Inlet LinersIn gas chromatography, the inlet is the first part of the instrument that your sample comes in contact with. Using the right liner will aid insample vaporization; promote efficient, loss-free analyte transfer; and protect your column from contamination—so choosing the correctGC inlet liner is critical for ensuring accurate and precise data. Liners differ in geometric configuration/design, volume, base material,deactivation, and packing. But, choosing the right liner can be greatly simplified by looking at the type of injection. Variations in sampleand method may necessitate a different liner, but the following are great initial selections for any analysis. Split injection:- Topaz Precision split liner with wool. Splitless injection:- Topaz single taper liner with wool. Direct injection:- For semivolatiles or compounds that could be affected by a tailing solvent peak: Topaz Uniliner liner with the holedrilled near the bottom.- For aqueous injections or compounds that elute away from the solvent peak: Topaz Uniliner liner with the holedrilled near the top. Gas samples via sample loop injection:- Topaz straight liner with a 1.0 mm ID. PTV injection:- Instrument-specific Topaz liner with a small inner diameter and at least one baffle or dimple.For more information about liner selection,visit www.restek.com/liner-choicewww.restek.com/GCacc3

SeptaChoosing the right septum for your inlet is even easier. Restek offers severaloptions that are designed to avoid septum bleed and coring, which can damageyour column and your data: For temperatures up to 350 C*:- Thermolite Plus Septa For temperatures up to 400 C*:- Premium Non-Stick BTO Septa When coring is an issue (can create unwanted activity):- Thermolite Plus or Premium Non-Stick BTO Septa withCenterGuide dimple- Merlin Microseal SeptaFor more information choosing the right septum for youranalysis, as well as a handy size chart and septum choice guidelines,visit www.restek.com/septum-choice*For 17 mm inlets, the maximum temperature for Thermolite Plus septa is 300 Cand the maximum temperature for BTO septa is 330 C. For all injectors, minimumrecommended operating temperature for BTO septa is 250 C.Inlet SealsChoosing the right inlet seal is more a matter of convenience and preference than data integrity.As a general rule, however, especially for sensitive or splitless analyses, you want to avoid bare stainless steel and, instead, use highlyinert gold-plated seals to reduce breakdown and adsorption of active compounds.Restek offers several models of gold-plated inlet seals with washerless installation, including the customer favorite Dual Vespel Ringinlet seal. Its patented design features two soft Vespel rings—embedded in both the top and bottom surfaces—to help ensure alow-torque, leak-tight seal, even after repeated temperature cycles.4www.restek.com/GCacc

Preventative GC Inlet MaintenanceOnly after you have confirmed that you are using the right GC inlet supplies is it time to think about GC inlet maintenance. Evenwithin a single industry like environmental testing—let alone across separate industries such as petrochemical, food safety, andclinical diagnostics—there are simply too many variables in samples, injection techniques, instruments, detectors, etc., to be able torecommend a single general schedule to all analysts for replacing all liners, septa, and inlet seals. Your GC inlet maintenance schedulecould be twice a day if you are running particularly dirty samples, or once a year if you are using headspace GC. You need to determineyour preventative maintenance (PM) schedule on an analysis-by-analysis basis.When establishing a PM schedule specific to an analysis, the key term is “preventative.” You are trying to prevent unwanted downtimeby replacing your inlet supplies before you have a problem. This way, you can plan for the downtime and choose a time that is notdisruptive to your lab. You can also avoid lengthy troubleshooting sessions and missed deadlines.Simply keep track of how long it generally takes after maintenance to begin seeing data problems commonly associated with theinlet, and then schedule your PM for that analysis and instrument to occur before data problems tend to arise.Common data problems that can alert you to the need for GC inlet maintenance are: Loss of signal / loss of response Inlet activity Inlet discrimination Inlet leaks (e.g., seals around septa, O-rings, ferrules, etc.) Extraneous signal Contamination- O-ring bleed- Septum particles in the liner- Matrix buildup in the liner (off-gassing) Inlet activity- Analyte breakdown creating new compounds (extra peaks) Distorted signal / deteriorating peak shape (e.g., peak tailing) Inlet activity Inlet leaks (e.g., seals around septa, O-rings, ferrules, etc.)Once you’ve set your preventative maintenance schedule, you will also want to plan ahead for the components you will be replacing andorder your GC inlet supplies in advance. Restek’s chromatography experts recommend replacing septa, liners, O-rings, and inlet sealsat the same time when you perform GC inlet maintenance. After all, you could unknowingly have issues with multiple components,and the cost of each of these items is minimal compared to having to take your instrument offline more often than you needed.Which One to Choose.Do you need additional assistance with selecting the right GC inletsupplies or with GC inlet maintenance? Contact Restek TechnicalService (support@restek.com) or your local Restek representative.www.restek.com/GCacc5

Peak PerformanceEnsured by ProperGC Inlet Supplies,Maintained ProperlyChoosing the right GC inlet supplies—Restek Topaz liners,septa, inlet seals—and implementing a rigorous and timelypreventative GC inlet maintenance schedule can help ensureoptimum performance, maximum reproducibility, and minimizeddowntime for your lab.The inlet supplies you need to get started are right here, and you can alsofind them at www.restek.com/GCaccInlet Supplies for Agilent GCsTopaz Inlet Liners for Agilent GCsCOLUMN INSTALLS THIS ENDSplit Liners for Agilent GCsSplitless Liners for Agilent GCsSplit/Splitless Liners for Agilent GCsDescriptionID x OD x Length1 mm Split1.0 mm x 6.3 mm x 78.5 mm4 mm Straight w/Wool4.0 mm x 6.3 mm x 78.5 mm2 mm Precision Liner w/Wool2.0 mm x 6.3 mm x 78.5 mm4 mm Precision Liner w/Wool4.0 mm x 6.3 mm x 78.5 mm4 mm Cyclo4.0 mm x 6.3 mm x 78.5 mmwww.restek.com/GCacc19251-60540, 5190-2294 (ea.), 5183-4691, 5190-3164(5-pk.), 5183-4692 k.234685-pk.233055-pk.23312DescriptionID x OD x LengthSimilar to Agilent Part #qty.cat.#2 mm Splitless2.0 mm x 6.5 mm x 78.5 mm5181-8818 (ea.), 5183-4703 (5-pk.), 5183-4704 (25-pk.)5-pk.233132 mm Splitless w/Wool2.0 mm x 6.5 mm x 78.5 mm5-pk.233142 mm Single Taper2.0 mm x 6.5 mm x 78.5 mm5-pk.233152 mm Single Taper w/Wool2.0 mm x 6.5 mm x 78.5 mm5-pk.233164 mm Straight4.0 mm x 6.3 mm x 78.5 mm210-3003 (ea.), 210-3003-05 (5-pk.)5-pk.233014 mm Straight w/Wool4.0 mm x 6.3 mm x 78.5 mm19251-60540, 5190-2294 (ea.), 5183-4691, 5190-3164(5-pk.), 5183-4692 (25-pk.)5-pk.233004 mm Single Taper4.0 mm x 6.5 mm x 78.5 mm5181-3316 (ea.), 5183-4695 (5-pk.), 5183-4696 (25-pk.)5-pk.233024 mm Single Taper w/Wool4.0 mm x 6.5 mm x 78.5 mm5062-3587, 5190-2293 (ea.), 5183-4693, 5190-3163(5-pk.), 5183-4694 (25-pk.)5-pk.233034 mm Double Taper4.0 mm x 6.5 mm x 78.5 mm5181-3315 (ea.), 5183-4705 (5-pk.), 5183-4706 (25-pk.)5-pk.233084 mm Cyclo Double Taper4.0 mm x 6.5 mm x 78.5 mm5-pk.23310DescriptionID x OD x LengthSimilar to Agilent Part #qty.cat.#4 mm Straight w/Wool4.0 mm x 6.3 mm x 78.5 mm19251-60540, 5190-2294 (ea.), 5183-4691, 5190-3164(5-pk.), 5183-4692 (25-pk.)5-pk.23300Low Pressure Drop Precision Liner w/Wool4.0 mm x 6.3 mm x 78.5 mm5-pk.233095-pk.23467Low Pressure Drop Liner w/Wool6Similar to Agilent Part #4.0 mm x 6.3 mm x 78.5 mm5183-4647, 5183-4711, 5190-2295 (ea.), 5183-4701,5183-4712, 5190-3165 (5-pk.), 5183-4713 (25-pk.)

CIS4 and PTV Liners for Agilent GCsCOLUMN INSTALLS THIS ENDCIS4/TDU Liners for Agilent GCsAnalytical Controls TPI Inlet Liners forAgilent GCsSPME Liners for Agilent GCsDirect Injection Liners for Agilent GCs(for 0.25/0.32/0.53 mm ID Columns)DescriptionID x OD x LengthOn Column PTV1.7 mm x 3.0 mm x 71 mmSingle Baffle PTV2.0 mm x 3.0 mm x 71 mmSingle Baffle PTV w/WoolSimilar to Agilent Part #qty.cat.#5-pk.234305183-203610-pk.234312.0 mm x 3.0 mm x 71 mm5183-203810-pk.23432Baffled PTV1.5 mm x 3.0 mm x 71 mm5183-203710-pk.23433DescriptionID x OD x LengthSimilar to Gerstel Part #qty.cat.#Single Baffle CIS4/TDU2.0 mm x 3.0 mm x 78 mm013775-010-0010-pk.23283Single Baffle CIS4/TDU w/Wool2.0 mm x 3.0 mm x 78 mm012742-010-0010-pk.23284Baffled CIS4/TDU2.0 mm x 3.0 mm x 78 mm012436-010-0010-pk.23282DescriptionID x OD x Lengthqty.cat.#TPI for 0.53 mm ID columns2.4 mm x 4.0 mm x 71 mm10-pk.23429TPI for 0.25/0.32 mm ID columns2.4 mm x 4.0 mm x 71 mm10-pk.23428DescriptionID x OD x Lengthqty.cat.#SPME Liner0.75 mm x 6.35 mm x 78.5 mm5-pk.23434SPME Liner1.8 mm x 6.5 mm x 78.5 mm5-pk.23280DescriptionID x OD x Lengthqty.cat.#Drilled Uniliner (hole near bottom)4.0 mm x 6.3 mm x 78.5 mm5-pk.23306Drilled Uniliner (hole near bottom) w/Wool4.0 mm x 6.3 mm x 78.5 mm5-pk.23307Drilled Uniliner (hole near top)4.0 mm x 6.3 mm x 78.5 mm5-pk.23311QUANTITY DISCOUNTS AVAILABLE for orders of five or more 5-packs!In stock now — order today at www.restek.com/topazwww.restek.com/GCacc7

Inlet Supplies for Agilent GCsMerlin Microseal Septafor Agilent GCs Allow operation from 3 to 100 psi (general-purpose Microseal septa) or 1 to 45 psi (low-pressure Microsealsepta). 400 C max injection port temperature.The advantages of the Merlin Microseal septum include elimination of septum coring; longer life; andconsistent, low needle-insertion force. The Microseal septum incorporates two separate sealing mechanisms. These sliding seals eliminate septum coring and the resulting accumulation of septum crumbs inthe injection port liner.The Microseal septum uses a 23-gauge (0.63 mm, 0.025") needle or probe with a blunt, truncated conicaltip. Since the syringe plunger end details are determined by manual or autosampler compatibility, often aremovable needle syringe is an effective way to match both of these requirements. No adapter is requiredfor the Agilent inlet. Installation is simple, requiring no modification of the injection port.Note: Merlin Microseal septa require a23-gauge (0.63 mm, 0.025") needle orprobe with a blunt, truncated conicaltip. Compatible syringes and replacement needles are available atwww.restek.com.DescriptionGeneral Purpose Kit for Agilent GCs (3 to 100 psi)Nut (1), and general-purpose (#410) Microseals (2)Nut (1), and general-purpose (#410) Microseal (1)Merlin #Similar toAgilent Part 8152278222809Low Pressure Kit for Agilent GCs (1 to 45 psi)Nut (1), and low-pressure (#310) Microseals (2)Nut (1), and low-pressure (#310) Microseal (1)Replacement MicrosealsGeneral-Purpose Microseal (most applications, 3 to 100 psi)Low-Pressure Microseal (1 to 45 psi)Microseal for SPME Applications (3 to 100 psi)Replacement Microseal Nut41031021-014035182-34445181-88155182-3445Dual Vespel Ring Inlet SealsWasherless, Leak-Tight Seals for Agilent GCs Does not require a separate washer. Requires less torque to seal. Does not require retightening of reducing nut afterseveral oven cycles.Patented Extends column lifetime by preventing oxygenfrom reaching the column. Same price as the regular inlet seals with washers. Gold plating provides enhanced inertness.0.8 mm ID Dual Vespel Ring Inlet tek-TreatedStainless 1.2 mm ID Dual Vespel Ring Inlet SealGold-PlatedSiltek-TreatedStainless 921245Flip Seal Dual Vespel Ring Inlet SealsRestek Innovation! Patented. Reversible, two-sided design allows significantly more analyses than other seals, at the same price—simplyuse, flip, then use again! Vespel ring embedded in top and bottom surface eliminates need for a washer. Highly inert gold seals reduce breakdown and adsorption of active compounds, maximizing componenttransfer to GC column. Very little torque required to make seal—reduces operator variability.Restek innovation!Patented8www.restek.com/GCaccFlip Seal Dual Vespel Ring Inlet ated23411234122341323414Flip Seal Dual Vespel Ring Inlet Seal Kitqty.cat.#Includes: gold-plated inlet seal, reducing nut adaptor, 1/16" SS nutkit23406Note: The Flip Seal inlet seal requires a special reducing nut adaptor fitting, which is included in the kit.The Flip Seal Adaptor can be used with standard 1/16" ferrules.

Dual Vespel Ring Cross-Disk Inlet Sealsfor Agilent GCs Ideal for high-flow split applications 500 mL/min. Washerless, leak-tight seals.0.8 mm ID Dual Vespel Ring Cross-Disk Inlet 22083220852208422086Replacement Inlet Seals with Washersfor Agilent GCsNote: The 1.2 mm inlet seal is recommended when installing two columns using a two-hole Vespel/graphite ferrule.Single-Column0.8 mm ID (Opening)Similar toAgilent Part 41623417Gold-PlatedSiltek-TreatedStainless Steel0.53 mm ID Dual-Column1/16-inch ID 0-pk.cat.#Stainless Steel2039220393Gold-PlatedSiltek-TreatedStainless Steel0.25/0.32 mm ID Dual-Column1.2 mm ID (Opening)18740-20880Cross-Disk Inlet Sealsfor Agilent GCs Ideal for high-flow split applications 500 mL/min on Agilent 5890 GCs. Gold plating provides enhanced inertness versus stainless steel. All seals include washers.0.8 mm ID Cross-Disk Inlet SealGold-PlatedSiltek-Treated1.2 mm ID Cross-Disk Inlet SealGold-PlatedSiltek-TreatedSimilar toAgilent Part 0474Similar toAgilent Part rm Up Before You Run!Topaz liners, O-rings, inlet seals, and other Restek GC inlet supplies aremanufactured in strictly controlled environments and feature packagingdeveloped specifically for superior cleanliness and chromatographic performance. Despite providing you with incredibly clean and inert inlet supplies,we still recommend that you condition your system after performing GCinlet maintenance to help guarantee the best results possible from thevery first injections, so schedule your maintenance accordingly.www.restek.com/GCacc9

Inlet Supplies for Agilent GCsReplacement Viton O-Ringsfor use with the Agilent Flip Top Inlet Sealing SystemDescriptionSimilar toAgilent Part #qty.cat.#5188-536610-pk.22336Similar toPart #Agilent 5188-5365,Thermo 2900132010-pk.cat.#50-pk.cat.#2224122242Viton Replacement O-Rings for use with the Agilent Flip Top Inlet Sealing SystemViton O-RingsFor Agilent and Thermo TRACE 1300/1310 GCsFit split (6.3 mm OD) or splitless (6.5 mm OD) liners.DescriptionMaxTempViton O-Rings Agilent and Thermo TRACE 1300/1310 GCs300 CGraphite O-Ringsfor Agilent and Bruker/Varian 1177 InjectorsExcellent thermal stability at injection port temperatures up to 450 C!DescriptionMax TempSimilar toAgilent Part #10-pk.cat.#50-pk.cat.#450 C450 C5180-41685180-4173202962029820297202996.35 mm ID Graphite O-Rings for split liners6.5 mm ID Graphite O-Rings for splitless linersViton O-Ringsfor Apex LinersDescriptionMax. temp.qty.cat.#Viton O-Rings for APEX liners250 C25-pk.22067Inlet Wrenchfor Agilent 5890/6850/6890 GCs Use to remove the septum nut and weldments during GC maintenance.Use the smaller end to remove the septum nut.Use the larger end to tighten the split/splitless weldment nut.High-quality stainless steel construction.Meets original equipment performance.DescriptionInlet Wrench for Agilent 5890/6850/6890 GCsSimilar toAgilent Part #19251-00100qty.ea.cat.#22065Septum Nut Removal Toolfor Agilent 5890/6850/6890/7890 GCs Easily remove the septum nut without touching the heated nut—no more burned fingers! Unique, ergonomic handle—easy to grip. Nut remains in tool for quick reattachment.restek t.#Septum Nut Removal Tool for Agilent 5890/6850/6890/7890 GCsea.24918

Inlet Maintenance Kitfor Agilent GCs Includes the most common consumable GC supplies and tools. All parts meet or exceed performance of instrument manufacturer’s parts. Parts list makes reordering easy.Inlet kit includes: 0.4, 0.5, and 0.8 mm ID graphite ferrules Viton O-rings Capillary nuts Inlet seals Reducing nut Scoring wafer 11 mm Thermolite Plus septa with CenterGuide Topaz 4.0 mm ID single taper liner with wool Topaz 4.0 mm ID straight liner with woolCapillary column caps1/4" x 5/16" wrenchSeptum pullerInstallation gaugeWire cleaning brushJet reamers/ferrule removersInlet liner removal toolSepta nut removal toolDescriptionqty.cat.#Inlet Maintenance Kitkit22181Make Life Easier (MLE) Capillary Tool Kitfor Agilent GCsIncludes: Capillary installation gauge for Agilent GCs Inlet wrench for Agilent GCs Septum nut removal tool 1/8", 3/16", and 1/4" nylon brushes 1/4", 3/8", and 3/16" stainless steel wire tube brushes Stainless steel surface brush 6 stainless steel jet reamers (0.25–0.65 mm OD) 1/4" x 5/16" open end wrench 3/8" x 7/16" open end wrench 7/16" x 1/2" open end wrench 1/2" x 9/16" open end wrench Rubber-tipped slide-lock tweezers Scoring wafersInlet liner removal toolSeptum pullerMini wool puller/inserter tool4-inch tapered needle fileSwivel head flashlightMini hand drill set15 cm compact steel rulerPocket magnifierHigh-temperature string (1 meter)Pipe cleaner (12-inch)Cotton tip swabs (pk. of 25)Descriptionqty.cat.#MLE Capillary Tool Kit for Agilent GCskit22186FastPack Inlet Kits for Agilent GCs Convenient: all the parts you need in one package—no hunting for individual items. Economical: costs less than the sum of the individual parts. Clean: Mylar bag is factory sealed; no contamination of the products from weeks in the lab.Routine Maintenance with FastPack Inlet Kits (1 pack includes 5 maintenance kits.)Deactivated Liner4 mm Topaz Straight4 mm Topaz Single Taper4 mm Topaz Straight with Wool4 mm Topaz Gooseneck Splitless with Wool4 mm Topaz Precision with WoolLiner Dimensions (ID x OD x Length)cat.#4 mm x 6.3 mm x 78.5 mm4 mm x 6.5 mm x 78.5 mm4 mm x 6.3 mm x 78.5 mm4 mm x 6.5 mm x 78.5 mm4 mm x 6.3 mm x 78.5 mm2110121102211042325823259www.restek.com/GCacc11

Inlet Supplies for Bruker/Varian GCsTopaz Inlet Liners for Bruker/Varian GCsCOLUMN INSTALLS THIS ENDLiners for Bruker/Varian 1177 S/SLInjection PortsSPI Liners for Bruker/Varian S/SLInjection PortsLiners for Bruker/Varian 1078/1079Injection PortsDescriptionID x OD x Lengthqty.cat.#4 mm Split Liner w/Glass Frit4.0 mm x 6.3 mm x 78.5 mm5-pk.233304 mm Precision Liner w/Wool4.0 mm x 6.3 mm x 78.5 mm5-pk.233284 mm Single Taper4.0 mm x 6.5 mm x 78.5 mm5-pk.233314 mm Single Taper w/Wool4.0 mm x 6.5 mm x 78.5 mm5-pk.23332DescriptionID x OD x Lengthqty.cat.#SPI Liner0.53 mm x 4.6 mm x 54 mm5-pk.23460SPI Liner0.80 mm x 4.6 mm x 54 mm5-pk.23461DescriptionID x OD x Lengthqty.cat.#3.4 mm Split–No Frit3.4 mm x 5.0 mm x 54 mm5-pk.23329Split w/Glass Frit3.4 mm x 5.0 mm x 54 mm5-pk.23462Splitless2.0 mm x 5.0 mm x 54 mm5-pk.23463SPME Liner0.75 mm x 5.0 mm x 54 mm5-pk.23465Split Precision Liner w/Wool3.4 mm x 5.0 mm x 54 mm5-pk.23466Similar to Bruker/Varian Part #190010907Merlin Microseal Septafor Bruker/Varian GCs400 C max injection port temperature.The advantages of the Merlin Microseal septum include elimination of septum coring, longer life, andconsistently low needle-insertion force. The Microseal septum incorporates two separate sealing mechanisms. These sliding seals eliminate septum coring and the resulting accumulation of septum crumbs inthe injection port liner.The Microseal septum uses a 23-gauge (0.63 mm, 0.025") needle or probe with a blunt, truncated conicaltip. Since the syringe plunger end details are determined by manual or autosampler compatibility, often aremovable needle syringe is an effective way to match both of these requirements. Installation is simple,requiring no modification of the injection port.DescriptionNote: Merlin Microseal septa require a23-gauge (0.63 mm, 0.025") needle orprobe with a blunt, truncated conicaltip. Compatible syringes and replacement needles are available at www.restek.com12www.restek.com/GCaccGeneral Purpose Kit for Bruker/Varian 1078/1079 GCsIncludes: nut (1); adapter (1); O-ring; and general-purpose (#410) Microseal (1)General Purpose Kit for Bruker/Varian 1177 GCsIncludes nut (1); adapter (1); O-ring; and general-purpose (#410) Microseal 22281522782Replacement MicrosealsGeneral-Purpose Microseal (most applications, 3 to 100 psi)Low-Pressure Microseal (1 to 45 psi)Microseal for SPME Applications (3 to 100 psi)

Liner Sealsfor Bruker/Varian 1078/1079 GCsDescriptionSimilar to Bruker/Varian Part #392611919,392534201Max. Temp.5 mm Graphite Liner Seals for Bruker/Varian 1078/1079 GCs450 Cqty.cat.#10-pk.22683Inlet Liner Sealsfor Bruker/Varian 1177 InjectorsMeets or exceeds original manufacturer’s performance.Description6.35 mm ID GraphiteO-Rings for split liners6.5 mm ID GraphiteO-Rings for splitless linersMax.Temp.Similar toBruker/Varian Part #10-pk.cat.#50-pk.cat.#450 C—2029620297450 C39-26119-402029820299Make Life Easier (MLE) Capillary Tool Kitfor Bruker/Varian GCsIncludes: Capillary installation gauge for Bruker/Varian GCs 1/8", 3/16", and 1/4" nylon brushes 1/4", 3/8", and 3/16" stainless steel wire tube brushes Stainless steel surface brush 6 stainless steel jet reamers (0.25–0.65 mm OD) 1/4" x 5/16" open end wrench 3/8" x 7/16" open end wrench 7/16" x 1/2" open end wrench 1/2" x 9/16" open end wrench Rubber-tipped slide-lock tweezers Scoring wafers Septum pullerMini wool puller/inserter tool4-inch tapered needle fileSwivel head flashlightMini hand drill set15 cm compact steel rulerPocket magnifierHigh-temperature string (1 meter)Pipe cleaner (12 inch)Cotton tip swabs (pk. of 25) Inlet liner removal toolEverything you need in onecomplete kit!Descriptionqty.cat.#MLE Capillary Tool Kitkit22184Leak-Free is the Way to BeA high-quality leak detector—like the Restek Electronic LeakDetector (cat.# 22655)—is a must for every GC lab. Every time youinstall a new column or perform GC inlet maintenance, be sure toleak-check your GC system before you condition or run an analysis.Minimizing the chances of damaging your column or detector willbe well worth the time.Get yours now at www.restek.com/leakdetectorwww.restek.com/GCacc13

Inlet Supplies for DANI GCsTopaz Inlet Liners for DANI GCsCOLUMN INSTALLS THIS ENDLiners for DANI GCsDescriptionID x OD x Lengthqty.cat.#0.8 mm ID Straight Liner0.8 mm x 6.0 mm x 70 mm5-pk.232930.8 mm ID Straight Liner(includes: ferrule set)0.8 mm x 6.0 mm x 70 mm5-pk.232862.0 mm ID Straight Liner2.0 mm x 6.0 mm x 70 mm5-pk.232922.0 mm ID Straight Liner(includes: ferrule set)2.0 mm x 6.0 mm x 70 mm5-pk.232852.2 mm ID Straight Liner w/Wool2.2 mm x 4.0 mm x 85.7 mm5-pk.232912.2 mm ID Dimpled Liner w/Wool2.2 mm x 4.0 mm x 55 mm5-pk.232962.2 mm ID Dimpled Liner w/Wool(includes: ferrule set)2.2 mm x 4.0 mm x 55 mm5-pk.232894.0 mm ID Straight Liner4.0 mm x 6.0 mm x 70 mm5-pk.232944.0 mm ID Straight Liner(includes: ferrule set)4.0 mm x 6.0 mm x 70 mm5-pk.232874.0 mm ID Straight Liner w/Wool4.0 mm x 6.0 mm x 70 mm5-pk.232954.0 mm ID Straight Liner w/Wool(includes: ferrule set)4.0 mm x 6.0 mm x 70 mm5-pk.232884.0 mm ID Single Taper Liner w/Wool4.0 mm x 6.0 mm x 70 mm5-pk.232974.0 mm ID Single Taper Liner w/Wool(includes: ferrule set)4.0 mm x 6.0 mm x 70 mm5-pk.23290Inlet Supplies for PerkinElmer GCsTopaz Inlet Liners for PerkinElmer GCsSplit Liners for PerkinElmer GCsSplitless Liners for PerkinElmer GCsPSS Liners for PerkinElmer GCsDI Liners for PerkinElmer GCsDescriptionID x OD x Lengthqty.cat.#Splitter w/Wool4.0 mm x 6.2 mm x 92.1 mm5-pk.234494 mm Split Precision Liner w/Wool4.0 mm x 6.2 mm x 92.1 mm5-pk.23450DescriptionID x OD x Lengthqty.cat.#2 mm Splitless w/Wool2.0 mm x 6.2 mm x 92.1 mm5-pk.23451DescriptionID x OD x Lengthqty.cat.#Auto SYS XL PSS Split/Splitless w/Wool2.0 mm x 4.0 mm x 86.2 mm5-pk.23317DescriptionID x OD x Lengthqty.cat.#Open-Top Uniliner w/Wool4.0 mm x 6.2 mm x 92.1 mm5-pk.23452PSS Drilled Uniliner (hole near top)2.0 mm x 4.0 mm x 86.2 mm5-pk.23281Drilled Uniliner (hole near top)4.0 mm x 6.2 mm x 92.1 mm5-pk.23453Drilled Uniliner (hole near bottom)4.0 mm x 6.2 mm x 92.1 mm5-pk.23454Perfect InstallationEvery TimeThere is never a question about which way toinstall a Topaz liner—simply orient it so that thecolumn installs toward the "R" in the Restek logo.14www.restek.com/GCacc

Merlin Microseal Septafor PerkinElmer GCs400 C max injection port temperature.The advantages of the Merlin Microseal septum include elimination of septum coring, longer life, andconsistent low needle insertion force. The Microseal septum incorporates two separate sealing mechanisms. These sliding seals eliminate septum coring and the resulting accumulation of septum crumbs inthe injection port liner.The Microseal septum uses a 23-gauge (0.63 mm, 0.025") needle or probe with a blunt, truncated conicaltip. Since the syringe plunger end details are determined by manual or autosampler compatibility, often aremovable needle syringe is an effective way to match both of these requirements. Installation is simple,requiring no modification of the injection port.DescriptionGeneral Purpose Kit for PerkinElmer GCs (3 to 100 psi)Includes: nut (1); adapter (1); O-ring; and general-purpose (#410) Microseals (2)Merlin#Similar to 2281522782Note: Merlin Microseal septa require a23-gauge (0.63 mm, 0.025") needle orprobe with a blunt, truncated conicaltip. Compatible syringes and replacement needles are available atwww.restek.comReplacement MicrosealsGeneral-Purpose Microseal (most applications, 3 to 100 psi)Low-Pressure Microseal (1 to 45 psi)Microseal for SPME Applications (3 to 100 psi)Make Life Easier (MLE) Capillary Tool Kitfor PerkinElmer GCsIncludes: 1/8", 3/16", and 1/4" nylon brushes 1/4", 3/8", and 3/16" stainless steel wire tube brushes Stainless steel surface brush 6 stainless steel jet reamers (0.25–0.65 mm OD) 1/4" x 5/16" open end wrench 3/8" x 7/16" open end wrench 7/16" x 1/2" open end wrench 1/2" x 9/16" open end wrench Rubber-tipped slide-lock tweezers Scoring wafers Inlet liner removal toolSeptum pullerMini wool puller/inserter tool4-inch tapered needle fileSwivel head flashlightMini hand drill set15 cm compact steel rulerPocket magnifierHigh temperature string (1 meter)Pipe cleaner (12-inch)Cotton tip swabs (pk. of 25)Descriptionqty.cat.#MLE Capillary Tool Kitkit22185Viton O-Ringsfor PerkinElmer PSS InjectorFits 4 mm OD liners.DescriptionMax.Temp.Similar toPE Part #qty.cat.#Viton O-Rings for PerkinElmer PSS Injector250 CN610174710-pk.20366Silicone O-Ringsfor PerkinElmer Auto SYS XL or Clarus With CAP InjectorFits 6.2 mm OD liners.DescriptionSilicone O-Rings for PerkinElmer Auto SYS XL or Clarus w/CAP InjectorMax.Temp.250 CSimilar toPE Part 5

Inlet Supplies for Shimadzu GCsTopaz Inlet Liners for Shimadzu GCsSplit Liners for Shimadzu 17A, 2010,and 2014 GCsCOLUMN INSTALLS THIS ENDSplitless Liners for Shimadzu 17A,2010, and 2014 GCsSplit/Splitless Liners for Shimadzu 17A,2010, and 2014 GCsLiners for Shimadzu 17A PTV GCsSPME Liners for Shimadzu 17A, 2010,and 2014 GCsDI Liners for Shimadzu 17A, 2010,and 2014 GCsLiners for Shimadzu 2010 PTV GCsDescriptionID x OD x Lengthqty.cat.#3.5 mm Split3.5 mm x 5.0 mm x 95 mm5-pk.233183.5 mm Split w/Wool3.5 mm x 5.0 mm x 95 mm5-pk.233193.5 mm Precision Liner w/Wool3.5 mm x 5.0 mm x 95 mm5-pk.23320Single Taper Precision Liner w/Wool3.5 mm x 5.0 mm x 95 mm5-pk.23455Cyclo3.5 mm x 5.0 mm x 95 mm5-pk.23456DescriptionID x OD x Lengthqty.cat.#3.5 mm Single Taper3.5 mm x 5.0 mm x 95 mm5-pk.233213.5 mm Single Taper w/Wool3.5 mm x 5.0 mm x 95 mm5-pk.233363.5 mm Single Taper w/Wool3.5 mm x 5.0 mm x 95 mm5-pk.23322Double Tape

Selecting the Right GC Inlet Supplies Using the wrong liner or septa can have just as negative an impact on your data as a fouled inlet. So, even if you are a seasoned GC veteran, it pays to take the time to be sure that you are using the right GC inlet sup-plies before worrying about how or when to perform GC inlet maintenance. Inlet Liners