Variable Displacement Pump (A)A10V Series-31

Transcription

Variable Displacement Pump (A)A10VSeries-31Industrial & Mobile, Single & Thru Shaft Models, A10V / AA10V18, 28, 45, 71, 100 & 140 Frame Sizes AvailableSame Day Shipment of Units or Parts OrdersDR, DRG, DFR, DFR1, DFLR ControlsSAE & Metric Unitswww.FluiDyneFP.com I sales@fluidynefp.com I 586-296-7200

IndexVariable Displacement Pump (A)A10V, Series 31. . . . . . . . . . . . . . . . . . . 4Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Technical Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5Ordering Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6Fluid Operational Conditions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8Noise Level. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9DR Pressure Control Data, Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10DRG Pressure Control Data / Remote Control / Dimensions. . . . . . . . . . . . . . . . . . . 12DFR/DFR1 Pressure / Flow Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13DFLR Pressure / Flow / Power Control / Dimensions . . . . . . . . . . . . . . . . . . . . . . . 15Mounting Dimensions, Size 18, Series 31 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17Service Ports on Side; Non Through Drive, Models 62N00 and 12N00. . . . . . . . . . . . . . . . . 17Mounting Dimensions, Size 28, Series 31 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18Service Ports at Side and Rear; Non Through Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18(A)A10V28 Shaft, Metric Mount, and Port Dimensions . . . . . . . . . . . . . . . . . . . . . . 19Mounting Dimensions, Size 45, Series 31 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20Service Ports at Side and Rear; Non Through Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20(A)A10V45 Shaft, Metric Mount, and Port Dimensions . . . . . . . . . . . . . . . . . . . . . . 21Mounting Dimensions, Size 71, Series 31 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22Service Ports on Side and Rear; Non Through Drive. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22(A)A10V71 Shaft, Metric Mount, and Port Dimensions . . . . . . . . . . . . . . . . . . . . . . 232Variable Displacement Pump (A)A10V, Series 31www.FluiDyneFP.com

Mounting Dimensions, Size 100, Series 31 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24Service Ports on Side & Rear; Non Through Drive. . . . . . . . . . . . . . . . . . . . . . . . . 24(A)A10V100 Shaft, Metric Mount, and Port Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25Mounting Dimensions, Size 140, Series 31 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26Service Ports on Side; Non Through Drive, Models 62N00 and 12N00. . . . . . . . . . . . . . . . . 26Through Drive. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27Overview of Through Drive Mounting Options / Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . 27Shaft Torque Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27Pump Installation Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31www.FluiDyneFP.comVariable Displacement Pump (A)A10V, Series 313

Variable Displacement Pump (A)A10V, Series 31FeaturesAxial piston pump A10V in swashplate design is used forhydrostatic transmissions in open loop circuits. Flow isproportional to drive speed and displacement. By adjustingthe position of the swashplate it is possible to smoothly varythe usingValveplateDFRcontrol valveEnd coverShaftReturning piston 4Flange connections to SAE-UNC or Isometric2 case drain portsHigh permissible speedsGood suction characteristicsLow noise levelHigh power/weight ratioVariable Displacement Pump (A)A10V, Series 31 Long service lifeQuick response timeAxial and radial loading of drive shaft possibleWide range of controlsThrough drive option for multi-circuit systemwww.FluiDyneFP.com

Variable Displacement Pump (A)A10V, Series 31Technical Data1. Input operating pressure rangeAbsolute pressure at port S (A)P min.0.8bar (12 psi)Pabsmax.30bar (435 psi)abs2. Output operating pressure rangePressure at port BNominal pressure PN.280bar (4000 psi)Peak pressure Pmax.350bar (5100 psi)Pressure data to DIN243123. Case drain pressureMaximum pressure of leakage fluid ( at ports L, L1 ). Maximum 7 psi ( 0.5 bar ) higher than input pressure at portS, but not higher than 30 psi ( 2 bar ) absolute.4. Direction of flow : ( S to B )5. Table of values (theoretical values, without consideringSize cm3/revmh andv ; values rounded)1828457110014018 (1.10)28 (1.71)45 (2.75)71 (4.33)100 (6.1)140 (8.54)33003000260022002000180059.4 (15.7)84 (22)117 (31)156 (41)200 (53)252 (67)28 (36.6)39 (51)55 (72)73 (96)93 (124)118 (156)DisplacementVg maxcm /rev (in /rev)Max. SpeedNo maxrpmMax. FlowOo maxL / min (gpm)Max. PowerPo maxkW (HP)Max. Torque@Vg max, No maxTmaxNm (ft - lb)80 (58)125 (91)200 (146)316 (230)w445 (324)623 (453)Kg (lbs)12 (27)15 (33)21 (46)33 (73)45 (99)60 (132)Weight (without fluid)33Notes: Values shown are valid for an absolute pressure of 1 bar at suction port. If the flow isreduced or if the inlet pressure is increased the speed may be increased.6. Determination of sizeFlowqv Torque T Powerwww.FluiDyneFP.comP Vg n ηv231Vg p24 π η mhqv p1714 η t[gpm][lb-ft][HP](((qv T P Vg n ηvVg p20 π η mhqv p600 η t)))[L/min]1000[Nm][kW]V g Displacement per revolution in in3 (cm 3 ) p Differential pressure in psi (bar)n Speed in rpm (min –1 )η v Volumetric efficiencyη mh Mechanical-hydraulic efficiencyη t Total efficiencyVariable Displacement Pump (A)A10V, Series 315

Variable Displacement Pump (A)A10V, Series 31Ordering Code(A)A10V(S)Axial Piston UnitSwash plate variable pumpO71DR/31R-PSA10VSwash plate variable pump for industrialA10VSMode of OperationPump, open circuitOSizeDisplacement 8.54)Pressure controlPressure remote controlllllllDRDRGPressure and flow controlPressure & flow (w/ X port blocked)llllllDFRDFR1Pressure,Flow & Power controlllllllDFLRcm3//rev(in3//rev)Control DevicesSeriesSeries31Direction of RotationViewed from shaft endclockwiseRcounter-clockwiseLSealsBuna-N (NBR per DIN IS0 1629) ;PFPM (flurocarbon)V18284571100140SAE- splined shaft, reinforced (U-type shaft)lllllllllllllllllll-WSAE- keyed shaftllllllKParallel with key DIN 6885llllllPShaft EndSAE-splined shaftSAE-splined shaft, reinforced (higher thru drive torque)SAE splined shaft, smaller size (not for pumps with thru drive)6Variable Displacement Pump (A)A10V, Series 31SRUwww.FluiDyneFP.com

Variable Displacement Pump (A)A10V, Series 31C62N00Through drives18Without through drive (Non-Thru Drive)284571 100 l-lllllllllllllK401)With through drive to accept an axial piston pump or a gear pumpMounting flange SAEJ744hub82-2 (A)3/4” keyed (A-B)axialA10V18 (K)101-2 (B)7/8” keyed (B)axialA10V28 (K)101-2 (B-B)1” keyed (B-B)axialA10V45 (K)127-2 (C)1-1/4” keyed (C)axialA10V71 (K)127-2 (C)1-1/2” keyed (C)radial A10V100 (K)152-4 (D)1-3/4” keyed (D)axialA10V140 (K)82-2 (A)5/8” 9T (A)axialA10V18(U)82-2 (A)3/4” 11T (A-B)axialA10V18(S,R), 10(S)101-2 (B)7/8” 13T (B)axialA10V28(S,R), 45(U,W)101-2 (B)1” 15T ( B - B )axialA10V45(S,R), 60(U,W)127-2 (C)1-1/4” 14T (C)axialA10V71(S,R), 100 (U,W)127-2 (C)1-1/2” 17T (C-C) axialA10V100(S,R), 85(S)152-4 (D)1-3/4” 13T (D)A10V140(S,R)1)sealing to -llllRear ports, UNC mounting screwsOpposite side ports, UNC mounting screwsRear ports, metric mounting screwsOpposite side ports, metric mounting screwsRear ports, UNC mounting screwsOpposite side ports, UNC mounting screwsRear ports, metric mounting screws-Opposite side ports, metric mounting screwsMounting Flange18284571100140SAE 2 1)K01K52K68/K02K04K07/K15K24K17See Thru Drives section for other options(Pressure port B and Suction port S)SAE 4 holeK051)Permitted with reduced thru drive torqueService PortsISO 2 holeK031)-62111292Ports 61,11, 91 &41 nonthroughdrive only4142CADl availableO in preparation- not availableVariable Displacement Pump (A)A10V, Series 317

Variable Displacement Pump (A)A10V, Series 31Fluid1. Fluid: AW68 (Q / TCNK 12-2001)2. Operating viscosity rangeV opt 16 mm2 / s 36 mm2 / s (80-170 sus)For optimum efficiency and service life we recommend that the operating viscosity (at operating temperature) beselected in the range:V opt opt. operating viscosity 16 36 mm2 / sReferred to tank temperature (open loop circuit).Limits of viscosity range(The following values are valid for extreme operating conditions):V min 10 mm2 / s (60 sus)For short periods (t 1 minute) at max. leakage oil temperature of 800C (176 0F)V max 1000 mm2 / sFor short periods upon cold start3. Temperature rangeT min -200C (-130F) : T max 800C ( 1760F)4. FiltrationIn order to ensure reliable operation of the axial piston unit the operating fluid must be maintained to a cleanlinessclass of at least 16 / 19 to IS04406. This may be achieved with filter elements with a cleanliness code of 10µm.Installation NotesThe pump housing must be filled with fluid during commissioning and remain full when operating. The concentricity betweenengine transmission shaft and pump shaft must be less than 0.05mm (0.002 in).8Variable Displacement Pump (A)A10V, Series 31www.FluiDyneFP.com

Variable Displacement Pump (A)A10V, Series 31Noise LevelCharacteristics for pumpMeasured in an sound chamberDistance from microphone to pump 3.3 ft (1m)Measuring error: 2 dB(A)Fluid: Hydraulic oil to ISO VG 46 DIN 51519, t 122 F(50 C)*Sound data representative of piston pumps of this design.www.FluiDyneFP.comVariable Displacement Pump (A)A10V, Series 319

Variable Displacement Pump (A)A10V, Series 31DR Pressure ControlThe pressure control serves to maintain a constant pressurein the hydraulic system within the control range of the pump.The pump therefore supplies only the amount of hydraulicfluid required by the actuators. Pressure may be smoothlyset at the pilot valve.Static characteristic( at n1 1450rpm ; toil 500C) 1220FP(Flow)Hysteresis and pressure increaseSetting rangePorts28020(290 psi)(4000 psi)Operating pressure p[bar]BPressure portSSuction portL, L1Case drain ports (L1 sealed)Control DataHysteresis and repetitive accuracySizeBar (psi). max. 3 bar (45 psi)182845711001404 (58)4 (58)6 (87)8 (116)10 (145)12 (174)Pilot oil consumption.max. approx. 3 L/min (0.8 gpm)10Variable Displacement Pump (A)A10V, Series 31www.FluiDyneFP.com

Variable Displacement Pump (A)A10V, Series 31Unit Dimensions DRService Ports at Rear; Models 61N00 and 11N00Sizes 18 to 140Mounting of pilotvalve for clockwisedirection of rotationMounting of pilotvalve for anticlockwisedirection of rotationUnit Dimensions DRService Ports on Side; Models 62N00 and 12N00Sizes 18 to 140Mounting of pilotvalve for anticlockwisedirection of rotationMounting of pilotvalve for clockwisedirection of rotationSizesA1 mm (in)A2 mm (in)28108.5 (4.27”)226.2 (8.91”)108.5 (4.27”)71106 (4.17”)279 (10.98”)108.5 (4.27”)126 (4.964”)-1845100140www.FluiDyneFP.com110 (4.33”)108.5 (4.27”)108.5 (4.27”)-245 (9.65”)344 (13.54”)A3 mm (in)A4 mm (in)105 (4.13”)126 (4.96”)108.5 (4.27”)146 (5.75”)108.5 (4.27”)127 (5.0”)136 (5.35”)160 (6.3”)158 (6.22”)169 (6.65”)Variable Displacement Pump (A)A10V, Series 3111

Variable Displacement Pump (A)A10V, Series 31DRG Pressure Control, Remote ControlFunction and design for DRG.CustomerSuppliedA pressure relief valve may be externally piped to port X for remotecontrol purposes. It is not, however, included with DRG control.The differential pressure at the pilot valve is set as standard to 20bar (290 psi) and this results in a pilot flow of (0.4gpm) 1.5 L/min.If another setting is required (in the range 10-22 bar), please statethis in clear text.Static Characteristic( at n1 1450rpm ; toil 500C) 1220FHysteresis and pressure increaseP(Flow)PortsBPressure portSSuction portXPilot pressure portL, L1Case drain ports (L1 sealed)Setting range20(290 PSI)280(4,000 PSI)Operating pressure p [bar]Control DataHysteresis and repetitive accuracy p.max 3 bar (45 psi)Max. pressure increasesSizeBar (psi)184 (58)284 (58)456 (87)718 (116)10010 (145)14012 (174)Pilot oil consumption.max. approx. 4.5 L/min(1.19gpm)12Variable Displacement Pump (A)A10V, Series 31www.FluiDyneFP.com

Variable Displacement Pump (A)A10V, Series 31DFR/DFR1 Pressure/Flow ControlIn addition to

Variable Displacement Pump (A)A10V Series-31 Industrial & Mobile, Single & Thru Shaft Models, A10V / AA10V 18, 28, 45, 71, 100 & 140 Frame Sizes Available