Air Receivers - Alup

Transcription

Air ReceiversAIR RECEIVERS

Air ReceiversFunctionalitiesSuitable for any application using compressed air. Storage function in order to handle high air consumption. Stabilize pressure peaks and provide a stable air flow. Perform a preliminary separation and removal of condensate.Moreover, installing an air receiver allows you to avoid thefollowing risks: Unstable pressure peaks. Multiple start/stop of the compressor. More condensate risk.Main benefits Pressure stabilizationbeneficial for pneumatic tools using compressed air. Storagefor handling high air consumption. Pulsation reductionVelocity reductionTemperature reduction Improvementof the life, reliability and functionality of your compressor. Condensate separationTypes2AIR RECEIVERSPainted vesselsGalvanized vesselsVitrified vessels (vitroflex)Painted vessels are used in themajority of cases where theair receiver is not submitted toextreme weather conditionsand perfectly clean air is not anabsolute prerequisite. The paintjob ensures protectionagainst corrosion.Galvanization is used to protectsteel against corrosion. The processitself is simple: the vessel iscompletely submerged in a zincliquid bath. As a result, the zinccoating perfectly adheres to theentire surface of the tank, ensuringfull protection of the steel.These vessels are treated withvitreous enamel, making themwater and steam resistant.The complete reliability of thistype of treatment is the resultof the inorganic composition andthe link created between theenamel and metal surface.After having been baked at 850 C,the enamel no longer absorbswater and fully protects the vesselagainst corrosion.

Air receiver capacityHow to select the size of my receiver?There is no one rule that fits all as some applications require larger airtanks because of the process.However, two rules of thumb that can help to finetune: Your air receiver capacity should be at least 1/4 of your free airdelivery expressed in m³/min. Base yourself on the compressor’s motor power and calculatethe capacity:Motorpower in HP x 30Example: If you install a 10HP screw compressor, your receivercapacity should be minimally 300 liter.Correctly sizing your air receiver brings the following benefits for yourcompressors’ operations: Less waste during unloading period. Overall smoother operation. Avoid mechanical stress on several components.Connection kitAIR RECEIVERS3

Technical specificationsPainted standard vesselsCapacity (L)10020027050072090010001500200030004000Pressure (bar)1111111110,8111211,511,511,511,511,5Diameter Ø37044650060075080080010001000120014501450H tot 70h ”1”1/41”1/41”1/41”1/41”1/4l (mm)298397599775895860745590595700780780m 0Kit type included1234467BBBBBWeight (kg)3751621271802002042783525378029235000Norm & standards87/404/CE97/23/CE (PED)Zinc standard vesselsCapacity (L)10020027050072090010001500200030004000Pressure r Ø37043050060079079079010001000120014501450H tot 70h 1”1/41”1/41”1/41”1/41”1/41”1/4l (mm)447397442689690800725590595700780780m 30Kit type included1AAAAABBBBBBWeight (kg)40556614318420922430638759188210255000Norm & standards87/404/CE97/23/CE (PED)Vitroflex standard vesselsCapacity (L)10020027050072090010001500200030004000Pressure ter ØN.A.43050060079079079010001000120014501450H tot 70h 1”1/41”1/41”1/41”1/41”1/4l (mm)N.A.397442689690800725590595700780780m 30Kit type includedN.A.AAAAABBBBBBWeight (kg)N.A.5060130167190204278352537802932Norm & standardsN.A.87/404/CE97/23/CE (PED)

Painted high pressure vesselsCapacity (L)5001000200030004000Pressure (bar)161616161616Diameter Ø6008001000120014301430H 852340237024502945Kit type included58CCWeight (kg)159246490620Norm & standards 87/404/CEnot included905105597/23/CE (PED)DøZinc high pressure vesselseCapacity (L)5001000200030004000Pressure (bar)161616161616Diameter Ø6007901000120014301430H 4502945m1760197523402370Kit type includedCCCCWeight (kg)176308539682Norm & standardsaacdnot included995116097/23/CE (PED)H totVitroflex high pressure vesselsmCapacity (L)5001000200030004000Pressure (bar)161616161616Diameter Ø6007901000120014301430H 176019752340237024502945Kit type includedCCCCWeight (kg)160280490620Norm & standardsbbIhfnot included905105597/23/CE (PED)AIR RECEIVERS5

DRIVEN BY TECHNOLOGY DESIGNED BY EXPERIENCEC O N TA C T Y O U R L O C A LS A L E S R E P R E S E N TAT I V E6999010350Your authorised distributor

Your air receiver capacity should be at least 1/4 of your free air delivery expressed in m³/min. Base yourself on the compressor’s motor power and calculate the capacity: Motorpower in HP x 30 Example: If you install a 10HP screw compressor, your receiver capacity should be minimally 300 liter.