Open-Web TrussesIncluding Red-L, Red-W, Red-S, Red-M and Red-H TrussesDownload your free copyat RedBuilt.com.Specify Open-Web trussesfor your next project usingRedSpec single-membersizing software.RedBuilt.com · 1.866.859.6757· OutstandingStrength-to-WeightPerformance· Design Flexibility· Easy Installation· Limited Product Warranty· Custom Manufacturing· Economical Truss Solutions

Welcome to RedBuiltRedBuilt is an exciting business offering building solutions for a broad rangeof commercial and custom residential applications. In addition to pioneeringunique manufacturing technologies, RedBuilt provides world-class service andtechnical support for architects, specifiers and builders.RedBuilt gives you access to reliable, innovative products, including RedBuilt open-web trusses, Red-I joists, and RedLam LVL beams and headers. Andwe keep things simple: You'll work with just one service-oriented supplier toget all these products—plus the support you need to build smarter.RedBuilt: A family of brand-name building products a source for innovativeideas and solutions a supplier that’s simpler to do business with.TABLE OF CONTENTSFeatures and Benefits3Design Center Services4Specifying Economical Trusses4Open-Web Truss Descriptions5Load Tables6–11Truss Details12–23Wind or Seismic Connections24–26Red-S , Red-M and Red-H TrussCap Plate Applications27Bridging28Allowable Duct Sizes29Installation Bracing30–31Long Span Installation32Material Weights33Snowdrift Loading34Tech Support and Analysis34Deflection and Camber Criteria35Nailing Information36Sound Details36–37Q&A38Specifications39ABOUT THIS GUIDEThe RedBuilt Open-Web Truss Specifier’s Guide is one of several guides that offertechnical information and design recommendations for RedBuilt products.This guide provides architects, designers, and engineers with information regardingopen-web trusses for commercial and custom residential applications.2

FEATURES AND BENEFITSProduct SelectionThis guide provides specifiers with technical information about the RedBuilt open-web truss product line.However, complex or custom applications can often make specifying the right products in the right places achallenge — especially when you have factors such as span, wind or load-carrying capacity and other designconstraints to consider. But whatever your project entails, RedBuilt is here to help. Your local RedBuilt technicalrepresentative, along with our Design Center teams, can assist you in choosing the best products and designing thebest system for your specific application.Contact us for help with any of the following:····Product selectionBuilding department calculationsComplete cost analysisSystem selection (system packages can include horizontal framing, maincarrying beams, headers, wall framing, mansard framing, and accessories)Products for Every ApplicationIn addition to open-web trusses, RedBuilt offers a variety of other engineeredlumber products that are ideal for use in commercial and custom residentialprojects. For more information, contact your RedBuilt technical representativeor visit redbuilt.com to download literature for products such as Red-I joistsand RedLam LVL.Unsurpassed Technical SupportRedBuilt has one of the largest networks of technical representatives in thebusiness. Their services include consultation, computer-assisted designand layout, delivery coordination, and installation review. They can suggestcost-reduction techniques and check special application requirements. Inaddition, they’re backed by a staff of professional engineers who providecomprehensive technical support when needed. Special requests areaccommodated wherever practical, and they offer cost analysis, engineeringanalysis, assistance with building code approvals — even the creation of specialproduct applications for more creative designs. The goal of RedBuilt technicalsupport is to help architects and engineers achieve quality design applicationswith the most cost-efficient product selection possible.Our network of technical representatives offers awide range of services to help guide your projectsthrough planning and construction.Resource EfficiencyConsider all of the positive attributes of wood when selecting your building material of choice. In addition to itsstructural properties, high strength-to-weight ratio, and ease of construction, wood is a naturally occurring, renewableresource that requires less energy to produce than steel or concrete. And it sequesters carbon — whether on the stumpor in your structure.Our RedBuilt open-web trusses with RedLam LVL chords, as well as other RedBuilt products, are made withresponsibly sourced fiber. Whether you’re looking for LEED certification or simply want to ensure efficient use of rawmaterials, we can help. By making better use of every tree, RedBuilt produces cost-effective, consistently availableengineered wood products that reduce environmental impact. The result is a quality wood product that offers superiorstrength and reliable performance.3

DESIGN CENTER SERVICESInstallation ReviewUpon request, RedBuilt can provide the following servicesfor the products described in this Open-Web Truss Specifier’sGuide:· A complete design package including layout drawings(placement diagrams) and detailed design calculations.· Review and analysis of the application.· Drawings or calculations sealed by a professional engineer.Although responsibility for proper installation lies with thecontractor-builder, RedBuilt provides detailed suggestionsand guidelines for installation. If requested, a RedBuiltrepresentative will visit the site to verify the contractor’sunderstanding of proper installation. RedBuilt professionalengineers also are available to help solve jobsite applicationproblems.Engineering Responsibility Position StatementRedBuilt is a manufacturer of proprietary structuralcomponents.It employs a staff of professional engineers to aid in thedevelopment, manufacture, and marketing of its products.RedBuilt does not replace or accept the responsibility of thedesign professional of record for any structure.RedBuilt accepts the delegation of engineering responsibilityonly for the products it manufactures, provided that theapplication conditions are specified by the design professionalof record, or other responsible party when a design professionalis not engaged. RedBuilt provides engineering in the design ofits products and does not displace the need on any project for adesign professional of record.Our technical support team offers professional capabilities in thedesign and application of all RedBuilt products.HOW TO SPECIFY TRUSSES FOR MAXIMUM ECONOMYIt is in the designer's best interest to specify the most economically efficient materials and ensure that their customers are notpaying extra for structural components that are oversized for the given loads. However, specifying a minimum depth truss withthe maximum plf loading (as shown in the load tables on pages 6–11) may not be the most economical solution.Designing to the maximum depth allowed for the application, and not maximizing loads in tables, will produce the mosteconomical solution. Keep this and the following two examples in mind when consulting the load tables in this guide:Deeper Can Be More EconomicalConsider An Alternative Truss SeriesExample:Example:Red-L Truss Series (Maximum PLF Capacity)Minimum Depth (Maximum PLF Capacity)32"32"14-Panel Truss10-Panel TrussRed-W Truss SeriesEconomical Depth32"36"9-Panel TrussCost Savingsof 12% 9-Panel TrussCost Savingsof 20% Red-S Truss Series32"7-Panel TrussCost Savingsof 23% Top chord bearing at each end provides the easiest installation and the most cost-effective truss system. Note that these aregeneral guidelines only and they are not reflective of all applications. Consult your local RedBuilt technical representative toassist you in specifying the most economical truss solutions for your particular applications.4

OPEN-WEB TRUSS DESCRIPTIONSRed-L and Red-W TrussesRed-S TrussesRed-M and Red-H TrussesChords:· Red-L trusses: 1½" x 3½" MSR lumber*· Red-W trusses: 1½" x 4¾" MSR lumberChords:Double 1½" x 2.3" RedLam LVLChords:· Red-M trusses: Double 1½" x 3½" MSR lumber*· Red-H trusses: Double 1½" x 5½" MSR lumber*Webs:1" and 11 8" diameter tubular steel membersvarying in gauge and diameter according torequirements.Weight:· Red-L trusses: 3.75 to 4.25 lbs/ft· Red-W trusses: 4.5 to 5.25 lbs/ftDepths:Minimum depth at wall . . . . . . . . . . . . . . . . . . . . . .14"Maximum depth at wall . . . . . . . . . . . . . . . . . . . . . .50"Maximum pitched ridge depth. . . . . . . . . . . . . . . .50"Any depth between minimum and maximum isavailable.Webs:1", 1¼", and 1½" diameter tubular steel membersvarying in gauge and diameter according torequirements.Weight:4.75 to 5.75 lbs/ftDepths:Minimum depth at wall . . . . . . . . . . . . . . . . . . . . . .16"Maximum depth at wall . . . . . . . . . . . . . . . . . . . . . .60"Maximum pitched ridge depth. . . . . . . . . . . . . . . .84"Any depth between minimum and maximum isavailable.Open-web trusses are intended for dry use,untreated applications.Webs:Up to 2" diameter tubular steel members varying ingauge and diameter according to requirements.Weight:· Red-M trusses: 8 to 9 lbs/ft· Red-H trusses: 10 to 12 lbs/ftDepths:Red-M Red-H Minimum depth at wall . . . . . . . . . . 20" . . . . . . 24"Maximum depth at wall . . . . . . . . . . 60" . . . . . . 72"Maximum pitched ridge depth. . . . 72" . . . . . .114"Any depth between minimum and maximum isavailable.*RedLam LVL chords may be available for Red-L, Red-M, and Red-H truss series. Consult your technical representative for availability and limitations.Building Codes and Product Acceptance: See ICC-ES ESR-1774, L.A. City RR #22614Truss ProfilesTightest Curvature Available:1Parallel Chord2Tapered3Pitched6BarrelRed-L and Red-W trusses . . . . . . . . . . . . 52' radiusRed-S trusses . . . . . . . . . . . . . . . . . . . . . . . 200' radiusRed-M trusses . . . . . . . . . . . . . . . . . . . . . Camber onlyRed-H trusses . . . . . . . . . . . . . . . . . . . . . Camber onlyTrussSeriesRed-L Red-W Red-S Red-M Red-H 7 Pitched Top Chord/Radius Bottom Chord8Scissor 4Radius Pitched5Bow String910Compound BarrelLenticular5Profiles Available4 5 6 7 8123910 Indicates that the profile is available.In radius truss applications (Profiles 5, 6, 7, 9,and 10), allowable loads are reduced due toradial stresses. Contact your RedBuilt technicalrepresentative for job-specific possibilities.Maximum top chord slope for Profile 4 (RadiusPitched) is ½:12 for Red-L and Red-W trussseries, and 3 8 :12 for Red-S truss series.

Load TablesRED-L TRUSS ALLOWABLE UNIFORM LOAD TABLE (PLF) / PARALLEL CHORDSEE PAGE 4 FOR ECONOMICAL TRUSS "22"24"26"100% TL115% TL100% TL115% TL100% TL115% TL100% TL115% TL100% TL115% TL100% TL115% TL100% TL115% TL100% LL125% TL100% LL125% TL100% LL125% TL100% LL125% TL100% LL125% TL100% LL125% TL100% LL125% 40163117150931367812767114589750944385387733· See page 5 for available depths and profiles. For depths and profiles not shown, contact your RedBuilt technical representative for assistance.· Red numbers refer to 115% Total Load (TL).General Notes· Values shown demonstrate maximum allowable load capacities based onthe following assumptions:· Straight line interpolations may be made between depths and spans.· Values in shaded areas may be increased 7% for repetitive-member use.– Simple span, uniformly loaded conditions, with provisions for positivedrainage (¼ :12 slope, minimum) in roof applications.· Bold italic values are controlled by minimum concentrated load analysisof 2,000 lbs. Higher loads are possible where minimum concentratedload analysis is not required by code. Contact your RedBuilt technicalrepresentative for assistance.– Span indicates distance from inside face to inside face of bearing.– Top chord no-notch bearing clips with 1¾" bearing. Higher values may bepossible with other types of bearing clips.General Notes continued on page 7Trusses delivered to the jobsite are custom manufactured to resist only project specific application loads provided by the design professional. Actual trusses may notbe able to resist the maximum loads shown in the tables above. For questions regarding actual truss capacity contact your RedBuilt technical representative.6

RED-L TRUSS ALLOWABLE UNIFORM LOAD TABLE (PLF) / PARALLEL CHORDSEE PAGE 4 FOR ECONOMICAL TRUSS 6"38"40"100% TL115% TL100% TL115% TL100% TL115% TL100% TL115% TL100% TL115% TL100% TL115% TL100% TL115% TL100% LL125% TL100% LL125% TL100% LL125% TL100% LL125% TL100% LL125% TL100% LL125% TL100% LL125% 751126610359955288488242763871356632· See page 5 for available depths and profiles. For depths and profiles not shown, contact your RedBuilt technical representative for assistance.· Red numbers refer to 115% Total Load (TL).General Notes continued from page 6To size floor trusses:Check both total load (100% TL) and live load (100% LL). When live load is notshown, total load will control. Total load values limit deflection to L/240. Liveload values are based on the Commercial Floor Deflection Limit shown onpage 35, and assume a nailed floor system. Live load (100% LL) values maybe increased with a glue-nailed floor system; contact your RedBuilt technicalrepresentative for assistance.To size roof trusses:Check the appropriate snow load area (115% TL) or non-snow load area(125% TL) value to determine the maximum allowable total load. Total load(115% TL and 125% TL) values limit truss deflection to L/180.Consult local codes to verify deflection limits required for specific applications.Trusses delivered to the jobsite are custom manufactured to resist only project specific application loads provided by the design professional. Actual trusses may notbe able to resist the maximum loads shown in the tables above. For questions regarding actual truss capacity contact your RedBuilt technical representative.7Load TablesContinued from page 6

Load TablesRED-W TRUSS ALLOWABLE UNIFORM LOAD TABLE (PLF) / PARALLEL CHORDSEE PAGE 4 FOR ECONOMICAL TRUSS 40"100% TL 115% TL 100% TL 115% TL 100% TL 115% TL 100% TL 115% TL 100% TL 115% TL 100% TL 115% TL 100% TL 115% TL 100% TL 115% TL 100% TL 115% TL 100% TL 115% TL 100% TL 115% TL 100% TL 115% TL 100% TL 115% TL 100% TL 115% '44'46'48'100% LL 125% TL 100% LL 125% TL 100% LL 125% TL 100% LL 125% TL 100% LL 125% TL 100% LL 125% TL 100% LL 125% TL 100% LL 125% TL 100% LL 125% TL 100% LL 125% TL 100% LL 125% TL 100% LL 125% TL 100% LL 125% TL 100% LL 125% 32206103166861467012759112491014290367431442 414 440453 404 445385 380 387385 316 397336 334 339336 249 342299 303 308297 206 309272 271 273273 160 277234 227 251245 127 252201 191 226215 104 231174 162 194188 87 207152 141 170165 71 184133 122 149144 59 162118 115 132128 51 144102 100 114109 44 12592 90 103100 38 11283 82 9389 33 23744384534423438303730383333422 445451374 388398340 348292 353305 314236 312275 280188 281251 252152 258212 236122 231179 216102 216157 18886 203136 16472 177127 14762 159114 12753 138102 11446 12490 10339 11282 9334 10273 8430 9278856778657159635556505047424242389 442 383 445 375 432 367 411 337 370 335 362454450472464468393385 388 380 397 369 390 359 385 338 383 314 383399401415401396395339 350 346 355 353 351 334 354 306 354 301 352328 355362 335 359358362364308 316 309 322 315 321 311 321 325 318 303 322264 315 289 316 304 323324327326280 285 284 289 283 291 283 288 281 295 289 292212 281 237 289 255 287 279 288 277 294295253 260 259 257 259 261 265 262 261 267 263 266174 259 194 264 212 263 232 267 235 267 259 264231 237 237 238 240 240 242 242 245 242 248 241142 236 162 237 179 239 196 243 216 243 220 243199 219 217 219 219 218 224 220 224 225 231 225118 216 134 221 149 222 167 223 185 226 202 224172 206 189 204 203 204 206 206 209 209 209 206100 202 111 204 127 201 141 206 158 209 175 206153 181 166 190 181 191 193 193 192 193 201 19385 185 95 190 106 193 121 193 137 193 149 193140 161 150 174 165 180 172 177 183 179 189 18272 175 82 180 92 179 104 181 117 181 131 182125 135 134 151 145 163 158 167 167 170 169 17062 151 71 165 81 169 91 166 100 170 113 170112 125 122 136 130 146 142 158 152 162 160 15954 136 62 148 70 160 78 159 88 160 97 162101 113 110 123 117 133 128 143 137 148 145 14947 123 54 133 61 143 69 151 77 149 85 15291 102 96 112 108 116 116 129 124 138 132 14341 110 47 119 54 131 61 140 68 144 75 14583 93 91 100 97 110 105 118 113 126 121 13536 102 42 111 47 120 54 128 60 137 67 13776 86 83 93 89 99 97 108 104 116 110 12332 93 37 101 42 109 48 117 53 126 59 13174 76 83 83 91 89 99 95 106 101 11385 33 93 38 100 42 108 48 116 53 1237179 76 85 82 92 87 98 94 1057986 34 92 38 100 43 106 48 1116773 70 79 76 85 81 91 86 967279 30 81 34 92 39 97 43 105606873 69 78 75 84 80 89667379 31 85 35 91 39 9757646875 70 80 75 8661697682 31 86 35 935360656975 69 805561697581 32 87505258657075505563717681324 326346302 331361296 344361283 325326287 291293262 264267242 245245224 226218 226208 208188 208195 193162 193182 183143 183170 170126 170162 160109 161153 15195 151139 14384 144128 13975 137117 13066 130108 12059 12699 10853 11792 10247 11185 9543 10379 9139 9874 8536 9269 7932 83318 325352299 324353282 316348288 319324276 293293266 265265244 243243225 220220209 207208 208195 194178 194181 182159 182172 170142 170162 160121 160153 152106 151146 14594 145135 13882 135124 13073 132114 12665 126105 11759 12097 10853 11490 9947 10983 9643 10378 9040 9773 8436 89304 342350299 325349269 331358276 315304259 291283263 259259240 238238222 217217204 202202189 191187 191180 180167 180170 166146 166159 157127 157150 151112 151143 143101 143137 13691 136130 12881 128120 12573 123110 11965 117102 11358 11395 10653 10788 10148 10282 9544 10077 8939 95· See page 5 for available depths and profiles. For depths and profiles not shown, contact your RedBuilt technical representative for assistance.· Red numbers refer to 115% Total Load (TL).General Notes· Values shown demonstrate maximum allowable load capacities based onthe following assumptions:– Simple span, uniformly loaded conditions, with provisions for positivedrainage (¼ :12 slope, minimum) in roof applications.– Span indicates distance from inside face to inside face of bearing.– Top chord no-notch bearing clips with 2¾" bearing for Red-W trusses andstandard bearing clips for Red-S trusses. Higher values may be possiblewith other types of bearing clips.· Straight line interpolations may be made between depths and spans.· Values in shaded areas may be increased for repetitive-member use asfollows: 7% for Red-W trusses and 4% for Red-S trusses.· Bold italic values are controlled by minimum concentrated load analysisof 2,000 lbs. Higher loads are possible where minimum concentratedload analysis is not required by code. Contact your RedBuilt technicalrepresentative for assistance.General Notes continued on page 9Trusses delivered to the jobsite are custom manufactured to resist only project specific application loads provided by the design professional. Actual trusses may notbe able to resist the maximum loads shown in the tables above. For questions regarding actual truss capacity contact your RedBuilt technical representative.8

RED-S TRUSS ALLOWABLE UNIFORM LOAD TABLE (PLF) / PARALLEL 2"100% TL 115% TL 100% TL 115% TL 100% TL 115% TL 100% TL 115% TL 100% TL 115% TL 100% TL 115% TL 100% TL 115% TL 100% TL 115% TL 100% TL 115% TL 100% TL 115% TL 100% TL 115% TL 100% TL 115% TL 100% TL 115% TL 100% TL 115% '46'48'50'52'54'56'58'60'62'100% LL 125% TL 100% LL 125% TL 100% LL 125% TL 100% LL 125% TL 100% LL 125% TL 100% LL 125% TL 100% LL 125% TL 100% LL 125% TL 100% LL 125% TL 100% LL 125% TL 100% LL 125% TL 100% LL 125% TL 100% LL 125% TL 100% LL 125% 8 487 558 496 570 464 533572 410 564 488 566590436 433 498 453 507 466 553474 300 531 357 541 425 567367 359 413 387 449 416 479399 221 449 273 488 318 509286 278 314 334 380 365 422333 170 375 207 417 249 456253 250 288 279 320 309 351281 133 313 162 346 194 383220 216 247 240 276 264 303237 105 269 129 297 154 326190 184 214 207 238 225 262207 85 233 105 259 126 285166 161 187 179 207 197 227179 70 203 86 223 102 248146 143 164 159 182 175 201149 58 178 71 198 84 218124 120 145 141 162 152 178124 48 157 59 176 71 193104 102 129 125 144 137 159104 41 133 50 157 60 17390 87 113 107 129 123 14389 35 113 43 139 51 15577 74 96 92 117 110 12976 30 97 37 120 44 1396684 79 104 96 1166684 32 104 38 125587390 83 106577390 33 83240483643364433403340467 516 416 478565531433 496 406 464520511414 501 388 457375 514 382 484376 438 386 443287 466 330 467338 388 355 408228 422 261 430288 331 312 359182 360 211 390249 286 269 310146 311 174 337217 249 235 270121 268 139 291187 219 207 238101 238 117 256167 194 180 21184 211 98 229148 173 160 18871 188 83 204132 151 145 16461 169 71 183119 140 129 15252 152 61 164110 127 120 13845 137 53 14998 115 105 12639 125 46 13787 106 100 11435 114 40 12476 98 89 10631 101 36 11588 79 9888 32 4434 463502417 449495373 427464375 429374 467354 406297 431329 382240 397289 334197 363252 291162 316223 256134 278195 227113 247176 20296 220155 17882 197139 16471 177126 14961 160117 13453 147108 12347 13599 11441 12491 10537 11481 9733 10686968486787771706464403 463 363 417 348 419501432458370 445 390 423 364 417462460453377 423 381 409 358 410467444425371 423 345 397 330 382464426438342 397 339 390 318 368332 429 338 422399325 375 326 376 321 370268 399 283 403 305 402311 355 317 358 313 358222 373 246 377 261 377271 312 287 330 298 345183 339 205 347 230 347236 274 255 293 271 311152 298 172 318 187 331209 243 221 259 240 276128 264 143 282 163 299189 217 199 232 214 246108 236 123 250 137 266168 195 179 208 192 22093 210 106 224 118 240151 176 160 188 174 20080 190 91 200 102 215138 156 148 169 157 17770 172 79 184 88 195123 145 135 154 144 16561 158 69 168 77 179116 133 124 142 130 15153 143 60 154 67 164105 121 113 130 121 13947 133 53 142 59 15198 113 105 120 110 12842 123 47 131 53 13991 104 97 111 103 11837 113 42 121 47 12883 97 90 103 95 11033 105 38 112 42 11975 90 83 96 89 10230 98 34 104 38 11183 77 89 83 9590 31 97 34 1037484 77 898191 31 97707883748390347 399 312 359 317 362433387393328 378 311 354 312 380394386413333 384 315 381 287 360417393391315 363 331 350 287 354395385385318 373 296 338 291 335393371363308 355 295 341 294 331385369363303 348 301 349 286 324281 374377361293 337 298 343 281 324241 352 261 352344281 324 273 316 274 315204 330 224 330 241 323254 292 267 303 273 302176 309 191 307 206 301227 261 239 275 251 285149 283 162 290 179 286200 234 215 247 226 258132 253 142 264 154 268184 211 193 223 204 233114 228 126 241 136 254167 192 176 201 185 21397 206 108 218 118 230148 174 160 184 168 19386 188 95 200 105 211135 160 147 169 155 17875 174 83 184 91 192128 147 135 155 140 16366 160 73 169 80 177118 135 123 143 130 15158 147 65 154 71 162109 125 115 132 120 13952 136 58 143 64 151101 116 107 122 112 12947 124 52 133 57 14094 108 99 113 104 11942 117 47 123 51 13088 101 92 106 97 11138 109 42 116 47 12282 94 86 99 90 10535 102 39 108 43 11477 88 81 93 85 9832 96 35 101 38 107· See page 5 for available depths and profiles. For depths and profiles not shown, contact your RedBuilt technical representative for assistance.· Red numbers refer to 115% Total Load (TL).General Notes continued from page 8To size floor trusses:Check both total load (100% TL) and live load (100% LL). When live load is notshown, total load will control. Total load values limit deflection to L/240. Liveload values are based on the Commercial Floor Deflection Limit shown onpage 35, and assume a nailed floor system. Live load (100% LL) values maybe increased with a glue-nailed floor system; contact your RedBuilt technicalrepresentative for assistance.To size roof trusses:Check the appropriate snow load area (115% TL) or non-snow load area(125% TL) value to determine the maximum allowable total load. Total load(115% TL and 125% TL) values limit truss deflection to L/180.Consult local codes to verify deflection limits required for specific applications.Trusses delivered to the jobsite are custom manufactured to resist only project specific application loads provided by the design professional. Actual trusses may notbe able to resist the maximum loads shown in the tables above. For questions regarding actual truss capacity contact your RedBuilt technical representative.9Load TablesSEE PAGE 4 FOR ECONOMICAL TRUSS DESIGN

Load TablesRED-M TRUSS ALLOWABLE UNIFORM LOAD TABLE (PLF) / PARALLEL CHORDSEE PAGE 4 FOR ECONOMICAL TRUSS 46"100% TL 115% TL 100% TL 115% TL 100% TL 115% TL 100% TL 115% TL 100% TL 115% TL 100% TL 115% TL 100% TL 115% TL 100% TL 115% TL 100% TL 115% TL 100% TL 115% TL 100% TL 115% TL 100% TL 115% TL 100% TL 115% TL 100% TL 115% '54'56'58'60'62'64'66'68'70'100% LL 125% TL 100% LL 125% TL 100% LL 125% TL 100% LL 125% TL 100% LL 125% TL 100% LL 125% TL 100% LL 125% TL 100% LL 125% TL 100% LL 125% TL 100% LL 125% TL 100% LL 125% TL 100% LL 125% TL 100% LL 125% TL 100% LL 125% 91367932327 330 369348 226 390278 277 313294 181 328235 239 271255 148 286206 208 231224 121 245185 185 206195 101 220164 164 181173 85 196146 148 162155 72 173131 133 148141 61 155119 118 133127 52 141110 109 121115 45 12999 99 110103 39 11690 86 10190 34 10780 76 9380 30 712159111521024695418837823375304

Red-L and Red-W Trusses Chords: Red-L trusses: 1 ½" x 3 ½" MSR lumber * Red-W trusses: 1 ½" x 4 ¾" MSR lumber Webs: 1" and 1 1 8" diameter tubular steel members varying in gauge and diameter according to requirements. Weight: Red-L trusses: 3.75 to 4.25 lbs/ft Red-W trusses: 4.5 to 5.25 lbs/ft Depths: