SPECIFICATION CATALOGCommercial 3 to 6 TonWater Source/Geothermal Heat Pump

VERSATEC VARIABLE SPEED SERIES SPECIFICATION CATALOGTable of ContentsModel Nomenclature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Electrical Availability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4AHRI Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-6The Versatec Variable Speed Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-12Inside the Versatec Variable Speed Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13-15Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16-34Application Notes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35-37Water Quality . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38Installation Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39-41Vertical Dimensional Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42-43Horizontal Dimensional Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44-45Hanger Bracket Locations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46Physical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48Blower Performance Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49Selection Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50-52Reference Calculations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53Legend and Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53Operating Limits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54Pressure Drop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55Performance Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56-63Wiring Schematics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64-69Engineering Guide Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70-72Revision Guide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73

VERSATEC VARIABLE SPEED SERIES SPECIFICATION CATALOGModel Nomenclature1-234-67891011121314151617181920 21-22 23UVV036TL001CANAN1A30SS*VintageV* – Factory UseModel TypepeUV – Versatecersateecc VarVVariabler eriablepeedSpeedNon-Standard OptionsSS – Standardnfigurrati onCabinet ConfigurationcalV – VerticalH – HorizontalontalDrain Pan Option0 – CompositeComposite,, No Secondary ConnectionComposite,, Secondary Connection1 – CompositeSteel,, No Secondary Connection2 – Stainless SteelSteel,, Secondary Connection3 – Stainless SteelUnit Capacitycity (MBTUH)(MMBTUMBUH)036, 048,8, 060060,0, 0720 2Discharge ConfigurationConffigguuraationT – Top (Vert(Vertical)ticcaal)E – End (Hori(Horizontal)izzoontaal)S – Sidee (Hor(Horizontal)rizzoontal)Air Coil Option3 – All-AluminumAll-Aluminum,, Uncoated4 – All-Aluminum,All-Aluminum, AlumiSealTMReturn Air ConfigurationConffigguuraationL – LeftR – RighthtFilter OptionA–11"" MERV 4B – 2"2" MERV 13Voltage600/10 – 208-230/60/13 – 208-230/60/3600/34 – 460/60/3Cabinet Option0 – Unpainted CabinetCabinet,, Filter Rail1 – Painted CabinetCabinet,, Filter Rail2 – Unpainted CabinetCabinet,, 4-Sided Filter RackCabinet,, 4-Sided Filter Rack3 – Painted CabinetRefrigeration Optiontion0 – Nonew o Pump2 – HWG Only w/opaasss6 – Hot Gas BypassElectrical OptionN – NoneD – DisconnectBlower Options1 – Variable Speededd ECM BlowerAurora Advanced Control OptionA – StandardE – AuroraTM DDCF – AuroraTM DDC w/LonWater Coil OptionnC – Copper, UninsulatednsulatedD – Copper, InsulatedlatedN – CuproNickel,, UninsulatedP – CuproNickel, InsulatedWater Control OptionN – NoneR – Water Flow RegulatorV – Modulating ValveF – Flow MeterSound Kit OptionA – NoneB – Sound KitRev.: 0D\ Electrical AvailabilityVS ECMModelVoltage036048060072208-230/60/1 208-230/60/3 460/60/3 575/60/3N/AN/AN/AN/ALegend:NA Not Available Voltage available in this size8/25/20164

VERSATEC VARIABLE SPEED SERIES SPECIFICATION CATALOGAHRI DataVS ECM MotorsAHRI/ASHRAE/ISO 13256-1English (IP) UnitsWater Loop Heat PumpModel036048060072CapacityModulationFlow RategpmcfmGround Water Heat PumpGround Loop Heat PumpCoolingEWT 86 FHeatingEWT 68 FCoolingEWT 59 FHeatingEWT 50 FCooling BrineFull Load 77 FPart Load 68 g BrineFull Load 32 FPart Load 41 6Cooling capacities based upon 80.6 F DB, 66.2 F WB entering air temperatureHeating capacities based upon 68 F DB, 59 F WB entering air temperatureAll ratings based upon 208V operationAll UV Series product is safety listed under UL1995 thru ETL and performance listed with AHRI inaccordance with standard 13256-1.5

VERSATEC VARIABLE SPEED SERIES SPECIFICATION CATALOGAHRI Data cont.The performance standard AHRI/ASHRAE/ISO 13256-1 became effective January 1, 2000 and replaces AHRI Standards320, 325, and 330. This new standard has three major categories: Water Loop (comparable to ARI 320), Ground Water (ARI325), and Ground Loop (ARI 330). Although these standards are similar there are some differences:Unit of Measure: The Cooling COPThe cooling efficiency is measured in EER (US version measured in Btu/h per Watt. The Metric version is measured in acooling COP (Watt per Watt) similar to the traditional COP measurement.Water Conditions DifferencesEntering water temperatures have changed to reflect the centigrade temperature scale. For instance the water loopheating test is performed with 68 F (20 C) water rounded down from the old 70 F (21.1 C).Air Conditions DifferencesEntering air temperatures have also changed (rounded down) to reflect the centigrade temperature scale. For instancethe cooling tests are performed with 80.6 F (27 C) dry bulb and 66.2 F (19 C) wet bulb entering air instead of thetraditional 80 F (26.7 C) DB and 67 F (19.4 C) WB entering air temperatures. 80.6/66.2 data may be converted to80/67 using the entering air correction table. This represents a significantly lower relative humidity than the old 80/67of 50% and will result in lower latent capacities.Pump Power Correction CalculationWithin each model, only one water flow rate is specified for all three groups and pumping Watts are calculated usingthe following formula. This additional power is added onto the existing power consumption. Pump power correction (gpm x 0.0631) x (Press Drop x 2990) / 300Where ‘gpm’ is waterflow in gpm and ‘Press Drop’ is the pressure drop through the unit heat exchanger at rated waterflow in feet of head.Blower Power Correction CalculationBlower power is corrected to zero external static pressure using the following equation. The nominal airflow is ratedat a specific external static pressure. This effectively reduces the power consumption of the unit and increases coolingcapacity but decreases heating capacity. These Watts are significant enough in most cases to increase EER and COPsfairly dramatically over ARI 320, 325, and 330 ratings. Blower Power Correction (cfm x 0.472) x (esp x 249) / 300Where ‘cfm’ is airflow in cfm and ‘esp’ is the external static pressure at rated airflow in inches of water gauge.ISO Capacity and Efficiency CalculationsThe following equations illustrate cooling calculations: ISO Cooling Capacity Cooling Capacity (Btu/h) (Blower Power Correction (Watts) x 3.412) ISO EER Efficiency (W/W) ISO Cooling Capacity (Btu/h) x 3.412 / [Power Input (Watts) - Blower Power Correction(Watts) Pump Power Correction (Watt)]The following equations illustrate heating calculations: ISO Heating Capacity Heating Capacity (Btu/h) - (Blower Power Correction (Watts) x 3.412) ISO COP Efficiency (W/W) ISO Heating Capacity (Btu/h) x 3.412 / [Power Input (Watts) - Blower Power Correction(Watts) Pump Power Correction (Watt)]Comparison of Test ConditionsCoolingEntering Air - DB/WB FEntering Water - FFluid Flow RateHeatingEntering Air - DB/WB FEntering Water - FFluid Flow RateARI 320ISO/AHRI13256-1WLHPARI 325ISO/AHRI13256-1GWHPARI 330ISO/AHRI13256-1 32**6832**Note *: Flow rate is set by 10 F rise in standard cooling testNote **: Flow rate is specified by the manufacturerPart load entering water conditions not shown.WLHP Water Loop Heat Pump; GWHP Ground Water Heat Pump; GLHP Ground Loop Heat PumpConversions:Airflow (lps) cfm x 0.472;esp (Pascals) esp (in wg) x 249;Water Flow (lps) gpm x 0.0631;Press Drop (Pascals) Press Drop (ft hd) x 29906

VERSATEC VARIABLE SPEED SERIES SPECIFICATION CATALOGThe Versatec Variable Speed SeriesThe Versatec Variable Speed represents a significant improvement in the commercial water source heat pump (wshp). TheR-410A product features high efficiency variable capacity compressors with industry leading standard options in a compactcabinet suitable for both retrofit and new construction applications. The product is also targeted to provide optimumperformance and flexibility in both water loop and geothermal applications.The Versatec Variable Speed is a new level of innovation and performancewith all new advanced controls mated with variable speed compressortechnology. Featuring the highest commercial efficiencies (Over 25 EER and7.8 COP ISO/AHRI 13256-1 WLHP) available in AHRI, the Versatec VariableSpeed is available in 4 variable speed capacity sizes (3 to 6 ton) withCopeland Gen2 Variable Speed Compressors and drives. These units featurehigh efficiency permanent magnet compressors coupled with high efficiencyelectronic drives to allow smooth capacity between 25 and 100%. TheseVersatec Variable Speed units utilize ozone-safe R-410A refrigerant to meetthe most stringent EPA requirements. Exclusive all aluminum air coils adddurability and longer life. Variable Speed ECM blower motors bridge the gapof high efficiency ECM capability with great value. ECM blowers are used toincrease comfort, efficiency, and airflow flexibility.The Versatec Variable Speed is managed by a sophisticated Aurora Control system that is modular and designed for themost demanding applications. The Aurora Control features a microprocessor control to sequence all components duringoperation for optimum performance. Plus, it provides easy-to-use troubleshooting features with fault lights, on-boarddiagnostics, and a hand held Aurora Interface Diagnostic (AID) Tool. The Aurora system includes advanced loop and hotwater generator pump control, as well as service, performance, and energy monitoring sensor kit capability.Vertical Versatec Variable Speed SeriesModels UVV 036-072 (3-6 tons) Variable SpeedHorizontal Versatec Variable Speed SeriesModels UVH 036-072 (3-6 tons) Variable SpSpeed7

VERSATEC VARIABLE SPEED SERIES SPECIFICATION CATALOGThe Versatec Variable Speed Series cont.Versatec Variable Speed Product HighlightsThe new product also features the following options (see nomenclature for more details) Wide selection of capacities from 036-072 MBtuh output. In addition with variable capacity compressors, eachmodel can have a 25%-100% capacity range (4:1 turn down). Complete commercial voltage selection of 208-230 V/60 Hz/1ph, 208-230/60/3, and 460/60/3 All-Aluminum rifled tube-and-fin air coils are not susceptible to formicary corrosion Balanced port bidirectional electronic expansion valve (EEV). Industry leading quality through engineering and manufacturing using quality components— High Efficiency and reliable permanent magnet variable capacity scroll compressors— High Efficiency variable speed ECM fan motors High efficiency performance for maximizing LEED points— With Variable ECM Blower Motor Up to 25.0 EER and 7.8 COP (ISO/AHRI 13256-1-WLHP part load) Small cabinet footprint for easy retrofit of much lower efficiency legacy product— Compact height and length horizontal cabinet matches legacy product 19 in. high 036, and 21 in. high 048-072— Short vertical cabinet Split access panel design for ease of service.Flexible Product with Several Standard Options Extended range insulation option Super Quiet Sound Package, including multi-densitycompressor blanket Quiet softstart variable speed scroll compressors inall models 2-dimension refrigerant piping vibration loops toisolate the compressor Double isolated compressor mounting utilizing eightdurometer selected rubber grommets Configurations – horizontal left and right return, endor side discharge (field switchable); vertical left andright return Heavy gauge cabinet and vibration isolatinghanger brackets Internal hot water generator coil (vertical only) Modulating Hot Gas Bypass Copper or cupronickel heat exchanger and optionalStandard Aurora Base Control or UPC DCC Controlwith standard N2, ModBus, BACnet, or optionalLonWorks card Optional ‘dial’ disconnect Optional painted cabinet Corrosion-proof composite drain pan or stainlesssteel drain pan with optional secondary drainconnection Filter options: standard 1 in. MERV 4 or optional 2in. MERV 13 factory installed with either filter railsor optional deluxe filter rack both field switchablebetween 1 in. and 2 in. Energy monitoring allows the complete power usageof the entire unite to be measured and displayed. Refrigerant monitoring allows the measurement ofdischarge and suction pressures, suction and liquidline temperatures, superheat and subcooling.Other options are available by special request throughfactory authorized representative.low temperature insulation Internally mounted water flow regulator and/or watersolenoid valve for variable speed pumping systems8

VERSATEC VARIABLE SPEED SERIES SPECIFICATION CATALOGThe Versatec Variable Speed Series cont.Product Features: Vertical CabinetVersatec Variable Speed vertical units are designed for high efficiency, maximum flexibility, and primary servicing from thefront.Standardfilter rail, fieldswitchable for 1in. or 2 in. filtersOptional powdercoated, heavy-gaugeG60 galvanized steelcabinetOptional factory mountednteddeluxe filter rack (shown),wn),field switchable for 1 in.n. or2 in. filterstersOptional factory installedwater heheating system withbuilt-in ccoil (vertical only, nofactory installedpump)inInsulated divider panelInsulaRemovable inlet rings fororeasy blower removalvalEC Fan Motor providesVS ECMfully vvariable speed airflow.b set to variable withCan becompcompressoror remainconstconstant.e/Oversized rifled tube/lanced fin all-aluminum aircoil (optional AlumiSealTMcoil coating).g).High Efficiency VariableCapaCapacityScroll Compressorhis a highefficiency permanentmagn motor driving a highmagnetreliabreliabilityscroll set.Corrosion-resistant,nt,composite drain pan withthoverflow protection, optionalnalsecondary drain connectiononOptiOptionalThermaShieldcoate coaxialcoatedheat exchanger forgeotgeothermaluseeelOptional stainless steelowdrain pan with overflowonalprotection, optionalionsecondary drain connectionElectElectronicExpansionValve (EEV) providesefficiefficientrefrigerant flow nomatt what conditions ormattercompcompressorcapacity is active.desAurora Controls providestotal management off allinternal systems using thecol.ModBus protocol.UPC (Optional) can be added toprovide BACnet, N2 or LON forconnection to building automationrora/UPCsystems (BAS). The Aurora/UPCsystem exposes many internalparameters such as airflow settings,configurations, temperatures andpressures as BAS registers for usesystem wide.Internally trappedcondensatecondensa line (Vert. only)Flush mounted waterconnections (no(n backupwrenches needed)Fault andstatus LEDsHigh Efficiency Compressor Driveis designed to limit drive lossesand provide a soft start for thecompressor.A true left and right return option is available.9

VERSATEC VARIABLE SPEED SERIES SPECIFICATION CATALOGThe Versatec Variable Speed Series cont.Product Features: Horizontal CabinetVersatec Variable Speed horizontal units are available in four cabinet sizes. The cabinets are designed for high efficiency,maximum flexibility, and primary servicing from the front.Optional factory mountedfilter rail accepts 1 in. and 2 in.filters (field switchable)OptionalThermaShieldcoated coaxialheat exchangerOversized rifledtube/lanced finall-aluminum air coil(optional AlumiSealcoil coating).oating).Optional hot gasbypass also availableHigh Efficiency Compressorpressor Driveis designed to limit driverive losses andprovide a soft start foror the compressor.ECM VS Fan Motorprovides fully variableprovspeed airflow. Can bespeeset to variable withcompressor or remaincompconstant.consFault and diagnostic LEDsAurora Controlsprovides totalmanagement of allllinternal systems usingsinggthe ModBus protocol.ocol.Option internally pilotedOptionalhot gas reheat valveFlushmounted waterconnectionsEasilyremovablecontrol boxCompressor vibrationisolation plateUPC (Optional)ional) can be added to provide BACnet, N2 orLON for connection to building automation systems (BAS).The Aurora/UPC system exposes many internal parameterssuch as airflow settings, configurations, temperatures andpressures as BAS registers for use system wide.ElectronicExpansionElecValveValv (EEV) providesefficientrefrigerantefficflow no matter whatconditionsor compressorcondcapacityis active.capaHigh Efficiency Variable CapacityScroll Compressor is a high efficiencypermanent magnet motor driving ahigh reliability scroll set.Four blower deck options are available. Factory or field conversion option of end or side discharge using switchable access panels and a factory only option of true left or right return air coil./HIW KDQG UHWXUQZLWK HQG GLVFKDUJH5LJKW KDQG UHWXUQZLWK HQG GLVFKDUJH/HIW KDQG UHWXUQZLWK VLGH GLVFKDUJH105LJKW KDQG UHWXUQZLWK VLGH GLVFKDUJH

VERSATEC VARIABLE SPEED SERIES SPECIFICATION CATALOGThe Versatec Variable Speed Series cont.Aurora ControlsQuiet OperationAll models incorporates several noise reductiontechnologies and is ARI 260 sound rated using th

diagnostics, and a hand held Aurora Interface Diagnostic (AID) Tool. The Aurora system includes advanced loop and hot water generator pump control, as well as service, performance, and energy monitoring sensor kit capability. Vertical Versatec Variable Speed Series Models UVV 036-072 (3-6 to