2711E-6.17, PanelView 1000e/1200e/1400e User Manual - Rockwell Automation

Transcription

Allen-BradleyPanelView 1000e, 1200e, and1400e OperatorTerminals(Cat. No. 2711E-T10C6, 2711E-K10C6,2711E-T10C7, 2711E-K10C7,2711E-T10C15, 2711E-K10C15,2711E-K12C6, 2711E-K12C6L2,2711E-T12C6, 2711E-T12C4,2711E-T14C6, 2711E-K14C6,2711E-T14C7, 2711E-K14C7,2711E-T14C15, 2711E-K14C15)UserManual

Important UserInformationBecause of the variety of uses for the products described in this publication, thoseresponsible for the application and use of this control equipment must satisfythemselves that all necessary steps have been taken to assure that each applicationand use meets all performance and safety requirements, including any applicablelaws, regulations, codes and standards.The illustrations, charts, sample programs and layout examples shown in this guideare intended solely for purposes of example. Since there are many variables andrequirements associated with any particular installation, Allen-Bradley does notassume responsibility or liability (to include intellectual property liability) for actualuse based upon the examples shown in this publication.Allen-Bradley publication SGI-1.1, Safety Guidelines for the Application,Installation, and Maintenance of Solid-State Control (available from your localAllen-Bradley office), describes some important differences between solid-stateequipment and electromechanical devices that should be taken into considerationwhen applying products such as those described in this publication.Reproduction of the contents of this copyrighted publication, in whole or in part,without written permission of Allen-Bradley Company, Inc., is prohibited.Throughout this manual we use notes to make you aware of safety considerations:!ATTENTION: Identifies information about practicesor circumstances that can lead to personal injury ordeath, property damage or economic loss.Attention statements help you to: identify a hazardavoid the hazardrecognize the consequencesImportant:Identifies information that is critical for successfulapplication and understanding of the product.PanelBuilder, PanelView, Data Highway Plus, DH , SLC and SLC 500 are trademarks, and PLC, PLC-2, and PLC-3 are registeredtrademarks of Allen-Bradley, Inc.Modbus is a registered trademark of AEG Schneider Automation, Inc.Intel is a trademark of Intel Corporation.IBM, PC, AT, XT, PS/2 and PC DOS are registered trademarks of International Business Corporation.Epson is a registered trademark of Seiko Epson Corporation.Microsoft Windows is a trademark, and Microsoft, MS, and MS-DOS are registered trademarks of Microsoft Corporation.All other brand and product names are trademarks or registered trademarks of their respective companies and are herebyacknowledged.

PrefaceAbout This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Intended Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Related Publications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Technical Support Services . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Introducing the PanelViewTerminalsP–1P–2P–2P–3Chapter 1Welcome to the PanelView Family . . . . . . . . . . . . . . . . . . . . . . . .Keypad and Touch Screen Terminals and Software . . . . . . . . . . . . .Keypad Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Function Keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Numeric Keypad . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Special Keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Touch Screen Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .PanelBuilder 1400e Configuration Software . . . . . . . . . . . . . . . .Features of the PanelView Terminals . . . . . . . . . . . . . . . . . . . . . . .Additional Features of the PanelView Terminals . . . . . . . . . . . . . . .Applicable Programmable Controllers and Connections . . . . . . . . .Remote I/O Communications . . . . . . . . . . . . . . . . . . . . . . . . . .Logix55xx . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .PLC-5/11, 5/15, 5/20, 5/25, 5/30, 5/40, 5/60, 5/80, and 5/250Processors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .PLC-5/10 Processor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .PLC-3 and PLC-3/10 Processors . . . . . . . . . . . . . . . . . . . . .PLC-2 Family Processors via 1771-SN or 1772-SD2 . . . . . . . .SLC-5/02, 5/03, or 5/04 via 1747-SN Series A or B . . . . . . . . .1771-SN I/O Subscanner Module . . . . . . . . . . . . . . . . . . . . .6008-SI IBM PC I/O Scanner . . . . . . . . . . . . . . . . . . . . . . . .6008-SV VME I/O Scanner . . . . . . . . . . . . . . . . . . . . . . . . . .6008-SQ DEC Q-BUS I/O Scanner . . . . . . . . . . . . . . . . . . . .DH Communications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Logix55xx . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .PLC-5/10, 5/11, 5/15, 5/20, 5/25, 5/30, 5/40, 5/60, 5/80, 5/40L,5/60L, 5/80L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .SLC-5/04 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .PLC2/PLC3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ControlNet Communications . . . . . . . . . . . . . . . . . . . . . . . . . . .Logix55xx . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .PLC-5/20C, 5/40C, 5/60C, 5/80C . . . . . . . . . . . . . . . . . . . . .PLC-5/20C15, 5/40C15, 5/60C15, 5/80C15 . . . . . . . . . . . . . 1–161–171–181–181–18Publication 2711E-6.17 – November 1998

toc–iiTable of ContentsInstalling PanelView 1000eTerminalsInstalling PanelView 1200eTerminalsPublication 2711E-6.17 – November 1998Chapter 2Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .PanelView 1000e Terminal Dimensions . . . . . . . . . . . . . . . . . . . . .Tools for Installing Your PanelView 1000e Terminal . . . . . . . . . . . . .Mounting Options for PanelView 1000e Terminals . . . . . . . . . . . . .Mounting a Clip-Mount Touch Screen Terminal in a Panel orWall Cutout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Mounting a Clip-Mount Keypad Terminal in a Panel or Wall CutoutMounting a Touch Screen Terminal in a 19-inch Rack . . . . . . . . .Mounting a Keypad Terminal in a 19-inch Rack . . . . . . . . . . . . .Setting Up the PanelView 1000e Terminal . . . . . . . . . . . . . . . . . . .Switching Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Backlight Intensity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Connecting Power to the Terminal . . . . . . . . . . . . . . . . . . . . . . .Connecting the Upload/Download Cable . . . . . . . . . . . . . . . . . .Connecting the Serial Printer . . . . . . . . . . . . . . . . . . . . . . . . . .Connecting the Dataliner . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Connecting an External Alarm Relay . . . . . . . . . . . . . . . . . . . . .Connecting a Terminal to Your PLC System . . . . . . . . . . . . . . . .Using the PCMCIA Card Slots . . . . . . . . . . . . . . . . . . . . . . . . .Using a Keyboard or Bar Code Reader . . . . . . . . . . . . . . . . . . �172–17Chapter 3Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3–1PanelView 1200e Terminal Dimensions . . . . . . . . . . . . . . . . . . . . .3–3Tools for Installing Your PanelView 1200e Terminal . . . . . . . . . . . . .3–5Mounting Options for PanelView 1200e Terminals . . . . . . . . . . . . .3–5Mounting a Stud-Mount Keypad or Touch Screen Terminal in a Panelor Wall Cutout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3–6Mounting a Clip-Mount Touch Terminal in a Panel or Wall Cutout .3–8Mounting a Stud-Mount Keypad Terminal in a 19-inch Rack . . . . . 3–10Mounting a Touch Screen Terminal in a 19-inch Rack . . . . . . . . . 3–10Setting Up the PanelView 1200e Terminal . . . . . . . . . . . . . . . . . . . 3–10Adjusting Contrast and Brightness . . . . . . . . . . . . . . . . . . . . . . . 3–10Switching Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–11Connecting Power to the Terminal . . . . . . . . . . . . . . . . . . . . . . . 3–11Connecting the Upload/Download Cable . . . . . . . . . . . . . . . . . . 3–12Connecting the Serial Printer . . . . . . . . . . . . . . . . . . . . . . . . . . 3–13Connecting the Dataliner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–14Connecting an External Alarm Relay . . . . . . . . . . . . . . . . . . . . . 3–14Connecting a Terminal to Your PLC System . . . . . . . . . . . . . . . . 3–15Using the PCMCIA Card Slot . . . . . . . . . . . . . . . . . . . . . . . . . . 3–17

Table of ContentsInstalling PanelView 1400eTerminalsChapter 4Configuring PanelViewTerminalsChapter 5toc–iiiOverview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4–1PanelView 1400e Terminal Dimensions . . . . . . . . . . . . . . . . . . . . .4–3Tools for Installing Your PanelView 1400e Terminal . . . . . . . . . . . . .4–5Mounting Options for PanelView 1400e Terminals . . . . . . . . . . . . .4–5Mounting a Stud-Mount Keypad or Touch Screen Terminal in a Panelor Wall Cutout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4–6Mounting Your PanelView 1400e Terminal in a 19-inch Rack . . . .4–7Mounting Your Keypad Terminal in a T30 Cutout . . . . . . . . . . . . .4–8Setting Up the PanelView 1400e Terminal . . . . . . . . . . . . . . . . . . .4–8Adjusting Contrast and Brightness . . . . . . . . . . . . . . . . . . . . . . .4–8Adjusting Horizontal and Vertical Position . . . . . . . . . . . . . . . . .4–9Switching Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4–9Connecting Power to the Terminal . . . . . . . . . . . . . . . . . . . . . . .4–9Connecting the Upload/Download Cable . . . . . . . . . . . . . . . . . . 4–11Connecting the Serial Printer . . . . . . . . . . . . . . . . . . . . . . . . . . 4–11Connecting the Dataliner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–12Connecting an External Alarm Relay . . . . . . . . . . . . . . . . . . . . . 4–12Connecting a Terminal to Your PLC System . . . . . . . . . . . . . . . . 4–13Using a Keyboard or Bar Code Reader . . . . . . . . . . . . . . . . . . . 4–15Power-Up Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Power On Self-Test (POST) . . . . . . . . . . . . . . . . . . . . . . . . . . .Firmware Integrity Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Battery Failure Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Watchdog Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Starting the Terminal in Configuration Mode . . . . . . . . . . . . . . . . . .The Configuration Mode Menu . . . . . . . . . . . . . . . . . . . . . . . . . . .Transferring Application Files . . . . . . . . . . . . . . . . . . . . . . . . . . . .Serial Application File Transfers . . . . . . . . . . . . . . . . . . . . . . . .Summary of Steps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Memory Card Transfers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Formatting the PCMCIA Card or the Onboard Flash Memory (F5)Erasing a Destination Partition (F4) . . . . . . . . . . . . . . . . . . . . . .Pass-Through Application File Transfers . . . . . . . . . . . . . . . . . .PLC Controllers Required for Pass-Through . . . . . . . . . . . . . . . .DH Direct/ControlNet Direct . . . . . . . . . . . . . . . . . . . . . . . . . .Selecting an Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Terminal Network Setup for Remote I/O Applications . . . . . . . . . . .Terminal Network Setup for DH Applications . . . . . . . . . . . . . . . .Terminal Network Setup for ControlNet Applications . . . . . . . . . . . .Application Startup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ��235–245–26Publication 2711E-6.17 – November 1998

toc–ivTable of ContentsApplication Security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Screen Security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Mode Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Setting Time and Date . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Terminal Response . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Button Audio, Alarm Audio, Audio Volume . . . . . . . . . . . . . . . . .Alarm Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Stuck Cell Timeout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Screen Saver Display Intensity (1000e only) . . . . . . . . . . . . . . .Screen Saver Timeout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Terminal Display Intensity (1000e only) . . . . . . . . . . . . . . . . . . .Aligning the 1200e Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Aligning on a Keypad Terminal . . . . . . . . . . . . . . . . . . . . . . . . .Aligning on a Touch Screen Terminal . . . . . . . . . . . . . . . . . . . . .Printing and Displaying Alarm Messages . . . . . . . . . . . . . . . . . . . .Printing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Print Priorities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Printing Screens from the Terminal . . . . . . . . . . . . . . . . . . . .Formatting Reports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Printer Errors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Displaying Alarm Messages . . . . . . . . . . . . . . . . . . . . . . . . . . .Terminal Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Performing Terminal Diagnostics . . . . . . . . . . . . . . . . . . . . . . . .Hours Logged . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Restoring Defaults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Upgrading Firmware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Terminal Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Fault Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Major Faults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Minor Faults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Mistakes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .System Errors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Terminal Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Verifying PanelView TerminalOperationPublication 2711E-6.17 – November 60Chapter 6Testing the PanelView Terminal . . . . . . . . . . . . . . . . . . . . . . . . . . .Downloading the Application File . . . . . . . . . . . . . . . . . . . . . . . . . .Matching Communications Settings . . . . . . . . . . . . . . . . . . . . . .Download Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Running the Application File . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Connecting the PLC Controller . . . . . . . . . . . . . . . . . . . . . . . . . . .Testing Retentive Objects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Testing the Whole System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6–16–26–26–26–36–36–46–4

Table of ContentsMaintaining PanelViewTerminalsChapter 7Troubleshooting PanelViewTerminalsChapter 8Specifications: 1000eOperator TerminalAppendix AMaintaining Your PanelView Operator Terminal . . . . . . . . . . . . . . .Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Cleaning the Touch Screen . . . . . . . . . . . . . . . . . . . . . . . . . .Cleaning the Keypad . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Cleaning the Enclosure . . . . . . . . . . . . . . . . . . . . . . . . . . . .CRT Intensity (1200e and 1400e) . . . . . . . . . . . . . . . . . . . . .Changing the Fan Filter (1200e and 1400e) . . . . . . . . . . . . . . . .Degaussing the CRT (1200e and 1400e) . . . . . . . . . . . . . . . . . .Avoiding Strong Magnetic Fields (1200e and 1400e) . . . . . . . . . .Backlight Replacement (1000e) . . . . . . . . . . . . . . . . . . . . . . . .Verifying Configuration Settings . . . . . . . . . . . . . . . . . . . . . . . . . .Major Fault Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Minor Fault Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Mistake Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Firmware Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .PLC Communication Problems: Remote I/O . . . . . . . . . . . . . . . . . .PLC Communication Problems: Data Highway Plus . . . . . . . . . . . .PLC Communication Problems: ControlNet . . . . . . . . . . . . . . . . . .Product List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Approvals and Compliances . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Safety Standards Approvals . . . . . . . . . . . . . . . . . . . . . . . . . . .EMC Standards Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . .Environmental Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . .European Union Directive Compliance . . . . . . . . . . . . . . . . . . . . . .EMC Directive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Low Voltage Directive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Intended Use of Product . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Wiring Recommendations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Terminal Weights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Front Panel Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Keypad Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Touch Screen Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Touch Cell Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Flat Panel Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Backlight Life . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Color Unit Display Attributes . . . . . . . . . . . . . . . . . . . . . . . . . . .Data Highway Plus Communications . . . . . . . . . . . . . . . . . . . . . . .ControlNet Communications . . . . . . . . . . . . . . . . . . . . . . . . . . . . .PLC Remote I/O Communications . . . . . . . . . . . . . . . . . . . . . . . . ��5Publication 2711E-6.17 – November 1998

toc–viTable of ContentsSerial Communications Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Keyboard and Bar Code Reader Support . . . . . . . . . . . . . . . . . . . .PCMCIA Memory Card Support . . . . . . . . . . . . . . . . . . . . . . . . . .AC Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Character Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .User Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Alarm Relay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Time and Date Clock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Temperature, Humidity, and Altitude . . . . . . . . . . . . . . . . . . . . . . .Ambient Operating Temperature Limits . . . . . . . . . . . . . . . . . . .Storage Temperature Limits . . . . . . . . . . . . . . . . . . . . . . . . . . .Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Maximum Altitude . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Heat Generation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Shock and Vibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Shock Amplitudes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Vibration Amplitudes for Operating Units . . . . . . . . . . . . . . . . . .Specifications: 1200eOperator TerminalPublication 2711E-6.17 – November 10Appendix BProduct List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Approvals and Compliances . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Safety Standards Approvals . . . . . . . . . . . . . . . . . . . . . . . . . . .EMC Standards Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . .Environmental Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Keypad Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Touch Screen Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . .Terminal Weights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Front Panel Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Keypad Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Stainless Steel Keypad Terminals . . . . . . . . . . . . . . . . . . . . . . .Touch Screen Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Touch Cell Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .CRT Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Color Unit Display Attributes . . . . . . . . . . . . . . . . . . . . . . . . . . .Degauss . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Data Highway Plus Communications . . . . . . . . . . . . . . . . . . . . . . .PLC Remote I/O Communications . . . . . . . . . . . . . . . . . . . . . . . . .Serial Communications Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . .PCMCIA Memory Card Support . . . . . . . . . . . . . . . . . . . . . . . . . .AC Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Character Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .User Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5B–6B–6B–6B–6

Table of ContentsAlarm Relay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Time and Date Clock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Temperature, Humidity, and Altitude . . . . . . . . . . . . . . . . . . . . . . .Ambient Operating Temperature Limits . . . . . . . . . . . . . . . . . . .Storage Temperature Limits . . . . . . . . . . . . . . . . . . . . . . . . . . .Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Maximum Altitude . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Heat Generation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Color Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Shock and Vibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Shock Amplitudes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Vibration Amplitudes for Operating Units . . . . . . . . . . . . . . . . . .Vibration Amplitudes for Non-Operating Units . . . . . . . . . . . . . . .Specifications: 1400eOperator �8B–8B–8B–8B–9B–9B–9B–9Appendix CProduct List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Approvals and Compliances . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Safety Standards Approvals . . . . . . . . . . . . . . . . . . . . . . . . . . .EMC Standards Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . .Environmental Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . .European Union Directive Compliance . . . . . . . . . . . . . . . . . . . . . .EMC Directive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Low Voltage Directive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Intended Use of Product . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Wiring Recommendations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Terminal Weights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Front Panel Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Keypad Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Touch Screen Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Touch Cell Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .CRT Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Color Unit Display Attributes . . . . . . . . . . . . . . . . . . . . . . . . . . .Degauss . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Data Highway Plus Communications . . . . . . . . . . . . . . . . . . . . . . .ControlNet Communications . . . . . . . . . . . . . . . . . . . . . . . . . . . . .PLC Remote I/O Communications . . . . . . . . . . . . . . . . . . . . . . . . .Serial Communications Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . .PCMCIA Memory Card Support . . . . . . . . . . . . . . . . . . . . . . . . . .Keyboard and Bar Code Reader Support . . . . . . . . . . . . . . . . . . . .AC Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Character Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .User Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Alarm Relay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ication 2711E-6.17 – November 1998

toc–viiiTable of ContentsBatteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Time and Date Clock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Temperature, Humidity, and Altitude . . . . . . . . . . . . . . . . . . . . . . .Ambient Operating Temperature Limits . . . . . . . . . . . . . . . . . . .Storage Temperature Limits . . . . . . . . . . . . . . . . . . . . . . . . . . .Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Maximum Altitude . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Heat Generation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Color Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Shock and Vibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Shock Amplitudes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Vibration Amplitudes for Operating Units . . . . . . . . . . . . . . . . . .Vibration Amplitudes for Non-Operating Units . . . . . . . . . . . . . . .Installing the PanelViewSerial Firmware UpgradeUtilityAppendix DInstalling SFU32 from CD-ROM on Windows NT or Windows 95 . . .Installing SFU from CD-ROM on Windows 95 or Windows 3.x . . . . .Installing SFU32 from Floppy Disks on Windows NT or Windows 95Installing SFU from Floppy Disks on Windows 95 or Windows 3.x . .Installing Additional Communication Drivers . . . . . . . . . . . . . . . . . .Starting the PanelView Serial Firmware Upgrade Utility . . . . . . . . . .Performing a Serial Firmware Upgrade . . . . . . . . . . . . . . . . . . . . .Exiting from the PanelView Serial Firmware Upgrade Utility . . . . . . .IndexPublication 2711E-6.17 – November D–7D–7D–8

About This ManualThis manual describes the PanelView 1000e, 1200e, and 1400eoperator terminals and includes information about the following: installing your PanelView terminal configuring your PanelView terminal verifying or testing your PanelView terminal maintaining your PanelView terminal troubleshooting your PanelView terminal"Note: This manual also applies to the enhanced PanelView 1200Series F and higher terminals running PanelView 1400e firmware.Chapter 1, Introducing the PanelView Terminals, provides anoverview of the PanelView 1000e, 1200e, and 1400e terminal family,summarizes new features, and lists applicable PLCs and connections.Chapters 2, 3, and 4, Ins

User Manual Allen-Bradley PanelView 1000e, 1200e, and 1400e Operator Terminals (Cat. No. 2711E-T10C6, 2711E-K10C6, 2711E-T10C7, 2711E-K10C7, 2711E-T10C15, 2711E-K10C15,