Molded Case Circuit Breakers 04/15/16 - Cloudinary

Transcription

Revised 04/15/16Molded Case Circuit BreakersED 125A Frame Sentron SeriesSelection Ordering Instructions All ED Frame Sentron circuit breakers are supplied with load side lugs. If line side lugs are required, add ”L” suffix to catalog number.Consult Siemens sales office for any addditional charge50 C Calibration, 400HZ - see page 7-89. All ED frame circuit breakers may be reverse connectedType ED2eBlue Label1-PoleContinuousCurrent Rating@ 40 C0150202503035040450500600708090100120V AC2-Pole125V DCCatalog 21B080nED21B090nED21B100n125V DC250V DC240V ACCatalog 22B090nED22B100Number ofPoles240V ACED2, ED4, ED6, HED4, HHED6Catalog 3B090nED23B100123Type ED4eBlue Label1-Pole120V AC277V AC2-Pole125V DC480V AC250V DCCatalog nED42B100ED42B110nED42B125480V ACCatalog 90ED43B100ED43B110ED43B125Type ED6eContinuousCurrentRating@ 40 C152025303540455060708090100110125Blue Label1-Pole 2-Pole347V AC600V ACCatalog B090ED61B100n——Catalog 0nED62B045nED62B050n———————Note: ED frame circuit breakers qualified to UL 489Supplement SB “Naval”— See page 7-89 foradditional informationn Built to order. Allow 2–3 weeks for delivery.a CSA Certified only (Not UL)Product Category MCCB3-Pole250V DC 600V AC3-Pole500V DCCatalog 90ED63B100ED63B110ED63B125b For600V DCCatalog ��—CED types and all 110–125 ampere ED frames.Note: A, page 7-86.rated.e HACR rated. Not for use with HHED6 breakers.c Seed SWDShippingWeight (lbs.)301010382538552030CED623LugsAmpereRatingNo. ofPolesCatalogNumberAluminum Body LugsLine/LoadAll 15–25A1, 2, 3SA1E025Line SideAll 30–100A1, 2, 3LN1E100ED2, 4, CED6Load Side130–60ALD1E060ED2, 4, CED6Load Side170–100ALD1E100ED2, 4,Load SideHED4, HHED6 2, 3LN1E10030–100AED6Line Side2, 320-50ALN1E100Line/LoadAll 110, 125A 2, 3TA1E6125Copper Body LugsLine/LoadAll 30–125A1, 2, 3TC1ED6150cCompression LugsCCE125All ED, HHED, CEDWireRange#14–#10 Cu#12–#10 Al#10–1/0 Cu/Al#10–#4 Cu/Al#6–#1/0 Cu/Al#10–1/0 Cu/Al#10–1/0 Cu/Al#3–3/0 Cu#1–2/0 Al#10–1/0 Cuonly2/0Enclosures (Neutral Included) Type1 (Surface)1 (Flush)3R4–4X7–97–9121 (Surface)1 (Flush)3R12Catalog NumberE2N1S (15–100A)E2N1F (15–100A)E2N3R (15–100A)ED6SS4 (15–100A)EA (15–60A)EB (70–100A)E2N12 (15–100A)CED6N1S bCED6N1F bCED6N3R bCED6N12 bModifications page 7-89Enclosures Section 6Accessories pages 7-45 and 7-93 to 7-98Siemens Industry, Inc. SPEEDFAX 2011 Product Catalog7-43MOLDED CASECIRCUIT BREAKERSCatalog D41B090nED41B100——3-PoleNumber perCarton7ContinuousCurrent Rating@ 40 ping Weights3-Pole

Revised 04/15/16Molded Case Circuit BreakersED 125A Frame Sentron SeriesSelection/Dimensions Type HED4f 480V ACD Catalog 3B080HED43B090HED43B100HED43B110HED43B125 D1H W1 W3W21-POLE2-POLE3-POLE FIGURE 2 - CED (3-Pole shown)D Catalog n Catalog 70nHED41B080nHED41B090nHED41B100n——250V DC 3-Pole480V AC 2-Pole125V DC 1-Pole277V ACFIGURE1 - ED, HED, HHED ContinuousCurrent Rating@ 40 C0150202503035040450500600708090100110125Black LabelFuseless Current LimitingContinuousCurrentRating@ 40 C3-Pole2-Pole3-Pole600V AC600V AC,250V DC600V AC,500V DC bCatalog Number gCatalog NumberCatalog 63B040HHED63B045HHED63B050———————H Red 7MOLDED CASECIRCUIT BREAKERSType CED6f Type HHED6f Black LabelD1 W2, W3Dimensions (in inches)Breaker TypeW1W2W3HDD1Figure 1ED2, ED4, ED6, HED4,ED6 ETI d1236.353.924.56Figure 1HHED6—236.533.924.56Figure 2CED6, CED6 ETI d—239.583.924.56Interrupting RatingsUL 489 AIR (File #E10848)IEC 947-2RMS Symmetrical Amperes (KA)Volts AC (50/60Hz)Volts ACBreaker TypeED2 (1-P)ED2 (2, 3-P)ED4 (1-P)ED4 (2, 3-P)ED6 (1P)ED6 (2, 3-P)ED6 (3-P)HED4 (1-P)(15–30A)HED4 (1-P)(35–100A)HED4 (2, 3-P)cHHED6 (2, 3-P)cCED6 (2, 3-P)Volts �—22————347————30 ��————4265200—n Built to order. Allow 2–3 weeks for delivery.a SWDrated.b When wired as shown on page 7-4, this circuit breaker isUL listed and rated for use on 500V DC ungrounded ��—18——125250500 0—————5 (2-P)—30 (2-P)————————18 —18 100———30 (2-P)—50 (2-P)——30 ——————c HED4600and HHED6 type circuit breakers meet the ULcriteria for “current limiting” at 240V AC.d ED6-ETI, CED6-ETI, see page 7-72 for orderinginformation.Siemens Industry, Inc. SPEEDFAX 2011 Product Cataloge SinglePole 15-30A 30KA @ 347V non-UL.35-100A 18KA @ 347V non-UL.f HACR rated.g HHED63B015A is rated 18KAIC at 600/347V.Product Category MCCB

Molded Case Circuit BreakersAccessoriesAccessories for:ED 125A FrameSelection Shunt Trip Combinations1 Shunt TripControl1 Shunt Trip and 1 Auxiliary Switch1 Shunt Trip andVoltage1 Shunt Trip1 Auxiliary Switch and 1 Alarm Switch 1 Alarm SwitchACDC024048120208240277480 CombinationsAvailable only when ordered together.Only one module can be added to abreaker. Additional accessories, whichalways attach to the left pole, cannot beadded to the combination later. Adds 1inch pole space.EquipmentGround Sensing012024048125250Catalog NumberCatalog NumberCatalog NumberCatalog NumberCatalog 2AAsUndervoltage Trip Combinations1 UndervoltageControl1 UndervoltageTrip andVoltageTrip1 Auxiliary SwitchACDC1202082402774806000240481252501 Undervoltage Tripand 1 Auxiliary1 UndervoltageSwitch andTrip and1 Alarm Switch1 Alarm Switch1 UndervoltageTrip and 2Auxiliary SwitchesCatalog NumberCatalog NumberCatalog NumberCatalog NumberCatalog 12ED62AAsAuxiliary Switch CombinationsMaximumVoltage1 Auxiliary Switch1 Alarm Switch and1 Auxiliary Switch2 Auxiliary Switches1 Alarm Switch and2 Auxiliary SwitchesDCCatalog NumberCatalog NumberCatalog NumberCatalog 01ED64B——MaximumVoltage1 Auxiliary SwitchACDC12MOLDED CASECIRCUIT BREAKERSAC240Catalog NumberA01EDLVGold Plated Contacts—for PLC useAlarm Switch OnlyMaximumVoltage1 Alarm SwitchACDCCatalog Number240250B00ED62480B00ED64Ground Fault Sensing Relay Kit — Equipment Protection OnlyFor Use WithBreaker FrameNumber ofPolesDescriptionCED6, ED2, ED4ED6, EFC, EFF,1, 2, 3HED4,HHED6Basic KitBasic Kit with NormallyOpen Bell AlarmBasic Kit with NormallyClosed Bell AlarmCatalog GF01ED60BCGF01ED65BCss Built to order. Allow 6–8 weeks for delivery.Product Category MCCBSiemens Industry, Inc. SPEEDFAX 2011 Product Catalog7A field addable kit containing 30mA or5 mA ground fault accessory module,current transformer with 24 inch leads,and current transformer mountingequipment. Current transformer tomount in gutter of lighting panel orany control panel. Accessory moduleoperates from separate 120V controlpower source.Both 30MA and 5MA devices areequipment protection devices only.Do not use for personnel protection.1 Shunt Trip and 2Auxiliary Switches7-47

Revised 07/20/14Molded Case Circuit BreakersFD 250A Frame Sentron SeriesSelection Ordering InformationBlue LabelType FXD6-A agNon-Interchangeable Trip (Assembled Circuit Breaker – Without Lugs)ContinuousCurrent Rating@ 40 C7080901001101251501752002252502-Pole3-PoleCatalog FXD62B250Catalog 3B250Complete Breaker Unassembledwith LugsPrices of FD6, HFD6, and HHFD6breakers includes frame, trip andboth line and load lugs (TA1FD350A).When ordered by these catalognumbers, the customer will receivethe frame, trip, and lugs separatelypackaged. For applications requiringdifferent lugs, order individual itemsas needed.Complete Breaker Assembled without LugsPrices of FXD6, HFXD6, HHFXD6,and CFD6 includes frame withnon-interchangeable trip unitinstalled only. Order required lugsseparately. For line and load lugs(TA1FD350A) installed, add suffix“L” to catalog number (add 2 timeslist price of lugs for each pole).50 C Applications see page 7-91.400 Hz Applications see page 7-91.Blue LabelType FD6-AgInterchangeable TripContinuousCurrent Rating@ 40 CComplete BreakerUnassembled w/LugsFrame OnlyTrip Unit OnlyCatalog NumberCatalog NumberCatalog 5nFD62T250n2-Pole 600V AC, 250V DC b708090100110125150175200225250MOLDED CASECIRCUIT BREAKERS73-Pole B175nFD62B200FD62B225nFD62B250nAC, 500V DC cLugs For 75 C Wire D63T250FD63F250TC1FD350Compression LugCCF250RMS Symmetrical Amperes (KA)UL 489 AIR (File E10848)Volts AC (50/60Hz)Volts DC240480600250500 cBreakerTypeFXD6-A, FD6-A65352230 (2-P) 18 (3-P)HFXD6 f, HFD6 f100652530 (2-P) 25 (3-P)HHFD6 f, HHFXD6 f20010025——CFD620020010030 (2-P) 50 (3-P)IEC 947-2Volts AC (50/60Hz)220/240 380/415lcu lcs lcu lcs65 333591005065 ———Instantaneous Adjustment Trip RangeNominal Instantaneous Values 20%Breaker Ampere 200152019008101060130017802100Note: FD frame qualified to UL489 supplement SB “NAVAL”.See page 7-91 for additional information.7-48Siemens Industry, Inc. SPEEDFAX 2011 Product Catalog8501140140019302300#6—350 kcmil Cu#4—350 kcmil Al#6—350 kcmil Cu350 kcmil Cu/AlEnclosuresInterrupting TypeCatalogNumber13R4-4X7-912Neutral dF6N1S(F)F6N3RFD6SS4EC2F6N12N250Modifications page 7-91Enclosures Section 6Accessories pages 7-50 and 7-95 to 7-100n Built to order. Allow 2–3 weeks for delivery. 20%ToleranceHigh9001200150020002500a TypeFXD6-A circuit breakers are UL Listed for reversefed applications.units are 3-pole width.c When wired as shown on page 7-4, this circuit breaker isUL listed and rated for use on 500V DC ungrounded UPSsystems only.d Order neutral as separate item.e See Note: A, page 7-88.f HFD6 and HHFD6 type circuit breakers meet theUL criteria for “current limiting” at 240 and 480V AC.g HACR rated.b 2-poleProduct Category MCCB

Revised 02/21/14Molded Case Circuit BreakersFD 250A Frame Sentron SeriesSelection/Dimensions Black LabelType HFD6, Type HFXD6 bcdefInterchangeable TripComplete BreakerUnassembled w/LugsFrame OnlyTrip Unit OnlyCatalog NumberCatalog NumberCatalog Number D1 ContinuousCurrent Rating@ 40 C2-Pole 600V AC, 250V DC (3-Pole Width)3-Pole 600V708090100110125150175200225250Type 5FD63T250HHFXD6 bcdfHHFD63F250 W Figure 1W Figure 2Dimensions (in inches)BreakerTypeWLDFigure 1FXD6-A, FD6-A,HFD6, HFXD6,HHFD6, FD6-ETI eFigure 2CFD6,CFD6-ETI eD1(tohandle)4.5009.5045.254.5014.2545.25Red LabelNumber ofNumber perShippingPolesCartonWeight (lbs.)FD6-A, HFD6, HHFD6, FXD6-AAssembled Circuit Breaker (less connectors)2108.63110FD6-A, HFD6, HHFD6 Frame Only2107.53108.7FD6 Trip Unit Only2101.13101.3CFD6 Assembled Circuit Breaker (less terminals)3116Non-Interchangeable Trip (Assembled Circuit Breakerwithout Lugs)ContinuousCurrent Rating@ 40 C070080090100110125150175200225250n Built to order. Allow 2–3 weeks for delivery.a Whenwired as shown on page 7-4, this circuit breakeris UL listed and rated for use on 500V DC ungroundedUPS systems.b For non-interchangeable trip 3-pole HFD6 type circuitProduct Category MCCB3-Pole600V AC/500V DCCatalog 25CFD63B250breaker, change prefix identifier from HFD6 to HFXD6.Price equals frame and trip prices combined, e.g. priceof HFXD63B250 equals price of HFD63F250 plus price ofFD63T250. Order lugs separately.c Type HFXD6, HHFXD6, CFD6 are UL Listed for reversefeed applications.d TypeHFXD6, HFD6, HHFD6, HHFXD6 meet the ULcriteria for “Current Limiting” at 240 VAC and 480V AC. e FXD6, ETI, CFD6, ETI — See page 7-74 forordering information.f HACR rated.Siemens Industry, Inc. SPEEDFAX 2011 Product Catalog7-49MOLDED CASECIRCUIT Type CFD6-AcfFuseless Current Limiting 3B225HHFD63B250LShipping Weights3-Pole 600V AC, Extra High 0n HFD62B250nAC, 500V DC aD708090100110125150175200225250

Molded Case Circuit BreakersInternal AccessoriesAccessories:for FD, FFC & FFF 250A FramesSelection Shunt Trip CombinationsControl Voltage1 Shunt TripAC024120240277480600Catalog 25250Undervoltage Trip CombinationsControl Voltage1 Undervoltage Trip1 Undervoltage Trip and1 Auxiliary SwitchAC120208240277480600Catalog NumberCatalog D64sW10FD64sW12FD64sAuxiliary Switch CombinationsVoltageACDC1 Auxiliary Switch2 Auxiliary SwitchesCatalog NumberCatalog NumberA01FD62A01FD64A01FDLV7240480MOLDED CASECIRCUIT BREAKERS12A02FD62A02FD64Gold Plated Contacts for PLC useAlarm Switch CombinationsMaximumVoltageAC480DC1 Alarm Switch1 Alarm Switch and1 Auxiliary SwitchCatalog NumberCatalog Number250B00FD64C01FD64s Built to order. Allow 6–8 weeks for delivery.a Auxiliary switch application is for 480V AC maximum.Note: Old F-frame accessories cannot be used in newSentron line. Likewise, new FD-frame accessoriescannot be used on old F-frame circuit breakers.7-50Siemens Industry, Inc. SPEEDFAX 2011 Product CatalogProduct Category MCCB

Revised 11/15/13Molded Case Circuit BreakersJD 400A Frame Sentron SeriesSelection Type JXD2-AeOrdering InformationBlue Label240V AC, 2-Pole 250V DC OnlyComplete Breaker Unassembledwith LugsPrices of JD6, HJD6, and HHJD6breakers include frame, trip andboth line and load lugs (TA2J6500).When ordered by these catalognumbers, the customer will receivethe frame, trip, and lugs separatelypackaged. For applicationsrequiring different lugs, orderindividual items as needed.Complete Breaker Assembled without LugsPrices of JXD6, HJXD6, HHJXD6,and CJD6 include frame withnon-interchangeable trip unitinstalled only. Order required lugsseparately. For line and load lugs(TA2J6500) installed, add suffix “L”to catalog number (add 2 times listprice of lugs for each pole).100% Rated (3-pole only)Types JXD6 and HJXD6 breakersare available with 100% ratings.To order add suffix “H” to catalognumber, and 10% to list price.n100% rated JD breakers require theuse of 90 C Cu cable sized at 75 Campacity and lugs TC1J6600or TC2J6500.50 C Applications see page 7-91.400Hz Applications see page 7-91.Non-Interchangeable Trip (Assembled Circuit Breaker without Lugs)Continuous CurrentRating @ 40 C2002252503003504002-Pole (3-Pole Width)Catalog B350nJXD22B4003-PoleCatalog 0JXD23B400Type JXD6-A aeBlue Label600V AC, 2-Pole 250V DC, 3-Pole 500V DC bNon-Interchangeable Trip (Assembled Circuit Breaker without D62B350nJXD62B400200225250300350400Blue LabelType JD6-AeInterchangeable TripContinuousCurrent Rating@ 40 CComplete BreakerUnassembled w/LugsCatalog NumberFrame OnlyCatalog NumberTrip Unit OnlyCatalog Number2-Pole 600V AC, 250V DC (3-Pole Width)2002252503003504003-Pole 600V T350JD63T400JD63F400Lugs For 75 C Wire cInterrupting RatingsBreakerTypeJXD2-AJXD6-A, JD6-AHJD6-A, HJXD6-AHHJD6, HHJXD6 dCJD6-ARMS Symmetrical Amperes (KA)UL 489 AIR (File E10848)IEC 947-2Volts ACVolts DCVolts AC (50/60Hz)(50/60Hz)220/240 380/415lcu lcs lcu lcs240480600250500 b065——30 (2-P) —————06503502530 (2-P) 25 (3-P) 065 033 040 2010006503530 (2-P) 35 (3-P) 100 050 065 33200100050——————20015010030 (2-P) 50 (3-P) ————CablesperWireLugRange1, 2#3/0-500 kcmil Cu2#4/0-500 kcmil AlTA1L67501500-750 kcmil Al1500-600 kcmil CuTC1J66001#3/0-600 kcmil CuTC2J65001, 2#3/0-500 kcmil CuCompression LugCCL6001500 kcmil —————Instantaneous Adjustment Trip RangeBreaker AmpereRating200-300350-400Nominal Instantaneous Values 20%ToleranceLow234567125020001430229016102570n Built to order. Allow 2–3 weeks for delivery.a TypeJXD2 and JXD6 circuit breakers are UL Listed forreverse feed applications.b When wired as shown on page 7-4, this circuit breaker isUL listed and rated for use on 500V DC ungrounded UPSsystems only.Product Category MCCB17902860196031402140343023203710 20%ToleranceHigh25004000Note: A, page 7-88.type circuit breakers meet the UL criteria for“current limiting” at 240 and 480V AC.e HACR rated.Note: JD frame qualified to UL489 supplement B“NAVAL.” See page 7-91 for additional information.c Seed HHJD6Modifications page 7-91Enclosures Section 6Accessories pages 7-54 and 7-95 to 7-100Siemens Industry, Inc. SPEEDFAX 2011 Product Catalog7-51MOLDED CASECIRCUIT 0nJD62B300nJD62B350nJD62B400500V DC b

Revised 02/21/14Molded Case Circuit BreakersJD 400A Frame Sentron SeriesSelection/Dimensions Black LabelType HJD6-A, HJXD6-A bdfInterchangeable TripComplete BreakerUnassembled w/LugsFrame OnlyTrip Unit OnlyCatalog NumberCatalog NumberCatalog Number D1 ContinuousCurrent Rating@ 40 C2-Pole 600V AC, 250V DC (3-Pole T225JD63T250JD63T300JD63T350JD63T400Black LabelType HHJD6, HHJXD6 bdf2-Pole 600V AC (3-Pole T4003-Pole 600VAC7MOLDED CASECIRCUIT T200JD63T225JD63T250JD63T300JD63T350JD63T400 W Figure 1 Figure 2Dimensions (in inches)BreakerTypeW LDToHandleD1Figure 1JXD2-A, JXD6-A, JD6-AHJD6-A, HJXD6-A, HHJD6, 7.5 11HJD6, HJXD6, HHJXD6,JXD6-ETI,c SJD6, SHJD645.44Figure 2CJD6, CJD6-ETI,c SCJD645.447.5 17.86Enclosures (Except SCJD6)TypeCatalog Number13R124X7, 9 (200-250A)7, 9 ipping WeightsType CJD6-A efFuseless Current LimitingRed LabelNon-Interchangeable Trip (Assembled Circuit BreakerWithout Lugs)ContinuousCurrent Rating@ 40 C200225250300350400W D3-Pole 600V AC, 500V DCL e600V AC/250V DC3-Pole600V AC/500V DCCatalog NumberCatalog NumberFor 2-pole applicationuse outside poles of3-pole circuit 63B350nCJD63B400Number ofNumber perShippingPolesCartonWeight (lbs.)JXD2, JXD6, JD6, HJD6, HHJD6Assembled Breaker (less terminals)2117.53119.5JD6, HJD6, HHJD6 Frame Only21143115.5JD6 Trip Unit Only2103.53104CJD6 Complete Assembled Breaker(less terminals)3131.5For inches / millimeters conversion, see Application Data section.n Built to order. Allow 2–3 weeks for delivery. 2-pole units available in 3-pole construction.a Whenwired as shown on page 7-4, this circuit breaker isUL listed and rated for use on 500V DC ungroundedUPS systems only.7-52b Fornon-interchangeable 3-pole HJD6 or HHJD6 typecircuit breaker change the prefix identifier to HJXD6or HHJXD6. Price equals price of frame plus price oftrip, e.g. price of HJXD63B400 equals price ofHJD63F400 plus price of JD63T400. Order lugsseparately.Siemens Industry, Inc. SPEEDFAX 2011 Product Catalogc JXD6-ETI,CJD6-ETI see page 7-74 for ordering information.HJXD6, HHJXD6 Circuit Breakers are UL listed forreverse fed applications.e CE applies to non-interchangeable type HJXD6-A only.f HACR rated.d TypeProduct Category MCCB

Molded Case Circuit BreakersSJD 400A Frame Digital Solid State Sentron Sensitrip III SeriesCurrent LimitingType SJD6-AType SHJD6-AType SCJD6-ABlue LabelBlack LabelRed Label3-Pole, 600V 00NTnSJD69200NGTnSJD69300NGTnSJD69400NGTnOrdering Information3-Pole, 600V AC3-Pole, 600V 0200300400SJD 400A Frame – 100% Rated bType SJD6-AType SHJD6-ABlue LabelBreakerTypeNumber perCartonShippingWeight (lbs)SJD6-ASHJD6-ASCJD6-A111202033No ofCablesper ConWirenectorRange2#3/0-500 kcmil CuTA2J6500 2#4/0-500 kcmil Al1500–750 kcmil AlTA1L67501500–600 kcmil CuTC1J6600 1#3/0-600 kcmil CuTC2J6500 2#3/0-500 kcmil CuTA2J6302#4–#3/0-Cu/AlCompression LugCCL600(1 pc.)#1/0-500 kcmil 0300400Neutral TransformersTrip Unit Adjustable urrent Timetaneous TimeTimeCodeTypeSetting DelaySetting Pick Up DelayShortTimeGroundFaultl 2tPick Up Pick ingCatalog Number200300400N02SJDN03SJDN04SJDMOLDED CASECIRCUIT 00NGTHnSHJD69400NGTHnShipping 0200300400SJD6 and SCJD6 are acceptable forreverse connection application. SHJD6 are not acceptable forreverse connection application.CatalogNumber3-Pole, 600V THnPricing information for all DigitalSentron Series SJD frames is forcomplete breaker only – pricerequired lugs as separate items –lugs are suitable for 75 C wire.Lugs for 75 C Wire aBlack Label3-Pole, 600V ACSelection GroundFaultDelayuuuuuInterrupting RatingsBreakerTypeRMS Symmetrical kA UL 489 (File E10848)240V AC480V AC600V ote: “G” suffix in catalog number denotes circuitbreaker for 3-phase, 3-wire systems.For 3-phase, 4-wire, order correct 4th wire (neutral)transformer as separate and additional item.Product Category MCCBn Built to order. Allow 2–3 weeks for delivery.additional information, see Note: A, page 7-88.to the NEC for proper application of 100%rated devices.aF orb ReferEnclosures Section 6Accessories pages 7-54 and 7-95 to 7-100Siemens Industry, Inc. SPEEDFAX 2011 Product Catalog7-53

Molded Case Circuit BreakersInternal AccessoriesAccessories for:JD 400A FrameLD 600A FrameLMD 800A FrameSJD 400A FrameSLD 600A FrameSelection Shunt Trip CombinationsControl Voltage1 Shunt Trip1 Shunt Trip and1 Auxiliary SwitchAC024048120240277480Catalog NumberCatalog ge Trip CombinationsSensitrip AmmeterControl Voltage1 Undervoltage Trip1 Undervoltage Trip and1 Auxiliary Switch1 Undervoltage Trip and2 Auxiliary SwitchesAC120208240480Catalog U10JLD6sU12JLD6sCatalog D62AU14JLD62AsU10JLD62AsU12JLD62AsCatalog 125250MOLDED CASECIRCUIT BREAKERS7Auxiliary Switch CombinationsThe Ammeter Display Units plug intothe Sensitrip Trip Unit and displaysthe phase current flowing in thebreaker. They are powered by thebreaker’s CT’s with replaceablebattery back-up for maintaining tripand max logs.The SADU reads currents, currentimbalance, current demand, and tripstatus.Ammeter Mounting KitThe Ammeter may also be panel ordoor mounted using the SADURMK18remote mounting kit.Note: Accessory modules can only be added to rightside pole of solid state SJD and SLD frame circuitbreakers. No accessories can be added ifmechanical interlock is used. All accessories on thispage are useable on superseded JD2, JJ6, JL6, HJ6,SJL, LJ6, LL6, HL6 and SLL circuit breakers.7-54MaximumVoltage1 Form C2 Form CACCatalog NumberCatalog VAlarm Switch CombinationsMaximumVoltageAC480DC1 Alarm Switch1 Alarm Switch and1 Auxiliary Switch1 Alarm Switch and2 Auxiliary SwitchesCatalog NumberCatalog ug-in Ammeter Display UnitsBreaker TypeDescriptionSJD, SLDDisplay UnitRemote Mounting KitCatalog NumberSADUSADURMK18s Built to order. Allow 6–8 weeks for delivery.Siemens Industry, Inc. SPEEDFAX 2011 Product CatalogProduct Category MCCB

Revised 02/21/14Molded Case Circuit BreakersLD 600A Frame Sentron SeriesSelection Ordering InformationBlue LabelType LXD6-A adNon-Interchangeable Trip (Assembled Circuit Breaker without Lugs)ContinuousCurrent Rating@ 40 C4505006002-Pole (3-Pole Width)3-Pole600V AC600V AC250V DC500V DCCatalog NumberCatalog 500LXD63B600Blue LabelType LD6-AdInterchangeable TripContinuousCurrent Rating@ 40 CComplete BreakerUnassembled w/LugsCatalog NumberFrame OnlyCatalog NumberTrip Unit OnlyCatalog Number2-Pole 600V AC, 250V DC (3-Pole Width)2503003504004505006003-Pole 600V nLD62B400LD62B450nLD62B500nLD62B600500V DC ng RatingsShipping Weights(lcs)————Instantaneous Adjustment Trip RangeBreaker AmpereRating250-300350-450500-600Nominal Instantaneous Values 05570 20%ToleranceHigh250040006000n Built to order. Allow 2–3 weeks for delivery.a TypeLXD6A circuit breakers are UL Listed for reversefed applications.wired as shown on page 7-4, this circuit breaker isUL listed and rated for use on 500V DC ungroundedUPS systems only.c See Note: A, page 7-88.d HACR rated.Note: LD frame qualified to UL489 supplement SB “NAVAL”.See page 7-91 for additional information.b When Product Category MCCBModifications page 7-91Enclosures Section 6Accessories pages 7-58 and 7-95 to 7-1002117.53119.5LD6, HLD6

CIRCUIT BREAKERS Product Category MCCB Molded Case Circuit Breakers ED 125A Frame Sentron Series Selection/Dimensions 1-POLE 2-POLE 3-POLE FIGURE1 - ED, HED, HHED n Built to order. Allow 2-3 weeks for delivery. aSWD rated. b When wired as shown on page 7-4, this circuit breaker is UL listed and rated for use on 500V DC ungrounded UPS systems.