Variable Frequency DriVes Tr200 Series - Danfoss

Transcription

Variable frequency drivesTR200 SeriesDrive your motor for energy savings

Energy efficiency & ReliabilityAt Trane, our philosophy is grounded in acommitment to offering solutions that supportenergy efficiency and take a sustainableapproach to the environment. We believe increating High Performance Buildings.Trane TR200 Series drives play an important role in a system to reduce energy usage, extend motor life, optimize AC motorspeed control, maximize occupant comfort and reduce costs. They are available factory-mounted and commissioned onTrane IntelliPak , Voyager III and M-Series and T-Series Climate Changers. In addition, TR200 Series drives’ supportof open standard protocols make them compatible with virtually all HVAC equipment and building automation systems. Theycan also be ordered specifically for a project and easily installed on-site for new and retrofit applications. With a completerange available from 1½ to 1350 HP, the features and flexibility of TR200 Series drives make them ideal for stand-alonecontrol of cooling towers, exhaust fans, pumps and a variety of air handlers.Energy SavingsEasy to Install Compact size—reduced footprint of most popular sizes. Run-permissive circuit—assures that dampers orother auxiliary equipment are in the proper state fordrive operation. Real-time clock—adds sophisticated performanceto basic control schemes for increased comfort andenergy savings. Plenum rated—all drives and options are UL listed forinstallation in air handling compartments. Automatic Energy Optimization (AEO)—continuallymonitors the motor’s speed and load to maximizeenergy savings.Sleep mode—stops the drive automatically wheneverspeed is outside set levels, providing energy savings.Cost Savings Intelligent HVAC controller—four auto-tuning PIDloops reduce costs by eliminating external controllers. Built-in HVAC protocols—TR200 drives become anintelligent part of the building management system.Trouble-Free Operation Dual DC-link reactors—non-saturating to providebetter harmonic performance than 5% AC line reactors. Automatic high ambient derate—the drive can warnof overtemperature conditions while continuing torun, controlling its temperature by reducing the outputcarrier frequency and current.Easy to Use Simple, flexible menu—pre-set default commonparameters allow easy set-up and quick confirmation. Trane Drive Utility software—allows easy PC accessfor commissioning and troubleshooting via the drive’sbuilt-in USB port. Advanced firefighter’s override—provides optionsfor emergency operation that increase the safety ofbuilding inhabitants.The following are trademarks or registered trademarks of their respective companies: Trane, TR200, IntelliPak, Voyager III are from Trane; BACNet from ASHRAE (American Societyof Heating, Refrigerating and Air-Conditioning Engineers); LonWorks from Echelon Corp; Modbus from Groupe Schneider

www.trane.comHVAC INTEGRATION EXPERTISEIntegrated Comfort systems are a single-source offering incorporating high-quality HVAC productsand controls, backed by a trusted and experienced sales force and extensive service network. Theycan also encompass fire safety and security systems from a single source. Trane builds upon 30years of experience in the controls industry and our firm commitment to new technology in practical,day-to-day applications. Our variable frequency drive, the TR200 Series, is an example of thiscommitment.Network communicationWhile offering single-source solutions, Trane standscommitted to open-standard protocols to meet the needsof building professionals. The TR200 Series demonstratesthis with “plug-and-play” communication capabilities thatreduce or eliminate the need for integration gateways.The TR200 support of major building communicationprotocols allows seamless communication with openstandard protocols such as BACnet , LonWorks andModbus as well as other popular building automationsystem protocols. Whether factory-installed on Trane HVACequipment, field-installed on new equipment, or retrofit onThe main closed-loop controller PID circuit allows threefeedback signals for advanced control of stand-aloneapplications. The TR200 has three additional independent PIDclosed-loop controllers that allow the drive to directly monitorand control other equipment in the system, reducing costs.BYPASS OPTIONSA higher level of system reliability is achieved by selectingeither of the two available bypass options. Both bypassoptions feature a 24 VDC switch mode power supply thateliminates contactor dropout on voltage conditions as lowas 70% of nominal voltage.existing equipment, the result is an easily programmableThe electro-mechanical bypass option provides reliabledrive in an easy-to-manage package that simplifiesbypass operation with advanced features such as a commoninstallation and results in a lower total cost of ownership.run/stop in bypass mode, runpermission, auto-bypass operationSTAND-ALONE CAPABILITIESand a selectable bypass fire mode.The TR200 VFD’s on-board control capabilities simplifyThesystem architecture by reducing or eliminating the needbypass option allows single-buttonfor an additional application controller. The TR200 Smartkeypad access to drive and bypassLogic Controller provides the power and flexibility tooperations. This option also allowscustom-program the drive to address a wide range offor all drive communication andcontrol requirements. Use the Trane Drive Utility softwarecontrol capabilities to be availableto graphically set up the 20-step state controller to performduring bypass operation to maintainsimple application control.indoor environmental quality.electronicallycontrolledTR200 keypad withone-touch accessto bypass operation

www.trane.comJust as Important as What’s in Your VFD.is What’s Behind itAnd behind every Trane VariableFrequency Drive you will find a worldleader in HVAC equipment, controls andservices. Whether preinstalled on Traneequipment, field applied or retrofit, theTrane TR Series VFD comes with themost important feature of all—ourproven capabilities throughout the lifeof your facilities:DesignRight applicationRight product Installation Properly installed On timeOperation Meet or exceed expectations Performance savingsService Minimize downtime Provide supportWe have a dedicated team ofprofessionals located at over 150 localoffices in the US and Canada and anetwork of over 200 parts centersto get you what you want, whenyou need it. To learn more about ourdrives and what’s behind them, visitwww.trane.com/vfd.Literature Order NumberBAS-SLB026-ENDateNovember 2008SupersedesNewFor more information, contact your local Trane office or e-mail us at comfort@trane.comTrane has a policy of continuous product and product data improvement and reserves theright to change design and specifications without notice. 2008 Trane

www.trane.comaCold plate coolingtechnologyFor efficient heat dissipationbcFor reduced harmonicscaBalanced dc-link reactorsbAdvanced controlleroptionsAddress the needs of complexapplicationsdgfdSurface mount componentsFor compactness and reliabilityheUsb interfaceFor easy connection to PC softwaresuiteefRemovable terminal stripsAngled for easy accessigOption cardsProvide additional functionalityhHot-pluggable keypadFeatures on-board memory withuser-friendly ergonomic designiRemovable, temperaturecontrolled FanFor easy servicing

www.trane.comSpecificationsDrive Input PowerEnvironmental LimitsInput voltage, 3-phase. 200–240, or 380–460, or 525–600 VACInput voltage range for full output. Nominal 10%Undervoltage trip point.164, 313 VAC, or 394 VACOvervoltage trip point. 299, 538, or 690(792 for 100 HP and above) VACInput frequency. 50 or 60 Hz, 2 HzDisplacement power factor.0.98 or greater at all speeds and loadsTotal power factor. 0.90 or greater at full loadand nominal motor speedEfficiency. 97% or greater at full load and nominal motor speedAmbient operating temp.14 F to 113 F ( 10 C to 45 C) framesA2–C2; 14 F to 104 F; ( 10 C to 40 C) frames D1–E1Humidity. 95%, non-condensingAltitude: maximum without derating. 3,300 ft. (1,000 m)Drive / options enclosure(s). NEMA/UL Types 1 or 12; 3R optionalDrive Output PowerOutput frequency. Selectable 0 to 120 HzMotor voltages. 200, 208, 220, 230; 380, 400,415, 440, 460; 550 or 575 VACContinuous output current. 100% rated currentOutput current limit setting. Adjustable to 110% of drive ratingCurrent limit timer. 0 to 60 seconds or infiniteAdjustable max. speed.From min. speed setting to 120 HzAdjustable min. speed.From max. speed setting to 0 HzAcceleration time. To 3,600 seconds to base speedDeceleration time. To 3,600 seconds from base speedBreakaway torque time.0.0 to 0.5 seconds(1.6 times motor nameplate current)Start voltage. 0 to 10%DC braking time.0 to 60 secondsDC braking start. 0 to maximum frequencyDC braking current.0 to 50% of rated motor currentProtectionsLow frequency and high frequency warnings. 0 to 120 HzLow current and high current warnings. 0 to maximum currentLow reference and high reference warnings. 999,999 to 999,999Low feedback and high feedback warnings. 999,999 to 999,999Ground fault. ProtectedMotor stall. ProtectedMotor overtemperature. Protected (predictive motor temp.)Motor condensation.Protected (motor preheat circuit)Motor overload. Protected (programmable action)Vibration protection.Protected (programming automated)Control ConnectionsFollower signal, analog input. 2; selectable voltage or current,direct and inverse actingProgrammable digital inputs. 6 (2 can be used as digital outputs)Programmable analog outputs. 1; 0/4 to 20 mAProgrammable relay outputs.2 standard Form C 240 V AC, 2 A;1 or 3 additional optionalAuxiliary voltage. 24 V DC, maximum 200 mAControl OptionalMCB 101 General Purpose I/O.3 DI, 2 DO, 2 AI (voltage)and 1 AO (current)MCB 105 Relay Card. 3 standard Form C 240 VAC, 2 AMCB 107 24V DC Supply.Allows external 24 V DC power to beconnected to the TR200 DriveMCB 115 Programmable I/O. Available 2nd half of 2009SoftwareLost speed reference action. Selectable to go to a preset speed,max. speed, last speed, stop, turn off, or stop and tripTime delay for lost speed reference action.1 to 99 secondsAdjustable auto restart time delay.0 to 600 secondsAutomatic restart attempts.0 to 20 or infiniteAutomatic restart time delay. 0 to 600 sec. between attemptsRelay ON delay and relay OFF delay.0 to 600 secondsMaximum number of preset speeds.16Maximum number of frequency stepovers.4Maximum stepover width. 100 HzMaximum number of accel rates.4Maximum number of decel rates.4Delayed start.0 to 120 seconds

Trane TR200 Series drives play an important role in a system to reduce energy usage, extend motor life, optimize AC motor . The TR200 VfD's on-board control capabilities simplify system architecture by reducing or eliminating the need for an additional application controller. The TR200 Smart