Vertiv Liebert CRVfrom 10 to 60 kWEfficient Cooling for IT Equipment

Vertiv Liebert CRV from 10 to 60 kWVertiv Vertiv designs, builds and services mission critical technologies that enable the vital applications for data centers, communicationnetworks, and commercial and industrial environments. We support today's growing mobile and cloud computing markets with ourportfolio of power, thermal, infrastructure management products, software and solutions, all complemented by our global servicenetwork. Bringing together global reach and local knowledge, and our decades-long heritage including brands like Chloride ,Liebert and NetSure , our team of experts is ready to take on your most complex challenges, creating solutions that keep yoursystems running—and your business moving. Together, we’re building the future of a world where critical technologies always work.YOUR VISION, OUR PASSION.Vertiv.comLiebert CRV Row-Based CoolingThe Liebert CRV, row-based coolingunit is optimized to ensure maximumcooling capacity in a minimal footprint.Targeted for small and medium datacenters, as well as edge computinglocations the unit provides cooling at theserver rack level.The Liebert CRV has been designed todeliver the highest efficiency andavailability, by removing heated air fromthe data center hot aisles, using it toreturn cooled air to the servers (coldaisle). The Liebert CRV is available inDirect Expansion, as well as Chilled Waterversions and in two frame widths - 600mm and a compact 300 mm. Providingfull capacity and airflow modulation tomatch the servers' load, the unit is able todeliver energy savings via its compressorwith capacity modulation, ElectronicExpansion Valve and variable speed ECFans. All this leads to very low operatingcosts with maximum availability. TheLiebert CRV is a omprehensive row-basedsolution that includes all of the mainfunctions fundamental to cooling units,such as cooling, humidification,dehumidification, re-heating, air filtration,condensation management, temperatureand humidity control, alarm functions anddata communications.Furthermore, the unit enhances itsperformances and energy efficiencythrough the Vertiv ICOM Control,capable of optimizing unit operations byleveraging on its intelligent managementof system components. All componentsare easily accessible from the front andthe rear of the unit, granting simplifiedservice intervention.The unit also allows ease of installation,through simplified cable and pipesrouting from top and bottom of the unit.10kW CRV DX2

Designed to Optimize IT PerformanceThe Liebert CRV, row cooling unitThermal Management unit is ideal forthe cooling of data center rack rowsThe Liebert CRV is a multi-option,precision air conditioner that deliverstemperature and humidity control, as wellas filtration and notification management,ensuring that data center temperaturesare maintained at an optimum level.The unit is designed to continuouslymonitor variations in heat loads andinstantly deliver the most efficient andeffective cooling necessary.Liebert CRV: Simple, Safe, AdaptableThe Liebert CRV is a plug-and-play unitwith the capability of addressing theneeds of both open and containedapplications.Cooling is provided at the server racklevel rather than the room level. TheLiebert CRV removes and filters hot airfrom the data center aisles, using it toreturn cooled air to the servers.The integrated air diffusers accuratelydirect the airflow towards the necessarydirection of the heat load.Furthermore, Liebert CRV is designed tocomply with mission-critical requirementsand ensure that servers are maintainedat the correct temperature andhumidity levels.For low operational costs, the Liebert CRVprovides the exact level of coolingrequired by servers, modulating theairflow and cooling capacity.The unit is available in two versions tomeet various installation demands:y A stand-alone, direct expansionsystem with variable capacity up to36 kW, available in both 300 mm and600 mm versions, complete with roofor wall-mounted condensery A chilled water system with up to 60kW of capacity available in both 300mm and 600 mm versions.Features andPerformanceyUnits ranging from 10 to 60kW with chilled water anddirect expansion versionsyIndustry's highest energysaving levels achieved increase of up to 50% whenthe Liebert CRV is combinedwith Vertiv SmartAisle cold aisle containmentyBest-in-class ThermalManagement unit for rowbased applicationsyOn-site adjustment capabilityof air diffuser distributiondirection maximizes coolingresultsyIntegrated Vertiv ICOM Control for management ofcapacity and airflow throughEC Fans and variable capacityCompressoryIdeal for scalable ITinfrastructure - increasedcooling capacity, reduced noiselevels and enhanced efficiencywhen compared with similarchilled water and directexpansion configurations.3

Vertiv Liebert CRV from 10 to 60 kWEnsuring Availability Under All Working ConditionsMaintaining IT InfrastructureAvailabilityWith integrated Vertiv ICOM Control,the Liebert CRV is able to monitorvariations in temperature and humidity,instantly adapting its performance tomeet variations in load conditions.This furthermore ensures increasedavailability and safety of protected ITequipment.The Liebert CRV's constant temperaturemonitoring and control capabilitiesensure the availability of servers in allworking conditions.Furthermore, its parallel load sharingfunctionality enables the management ofN 1 configurations.Meeting Primary IT RequirementsThe Liebert CRV's ability to modulatecapacity allows for constant, accurateroom temperature and humidity levels tobe maintained.The variable capacity capability of theLiebert CRV, contributes to increasingdata center availability during bothstandard operations and in the event ofload variations.The integrated compressors with coolingcapacity modulation are designed toavoid peaks in absorbed power, thusreducing the stress placed oncomponents. The Liebert CRV uses adedicated control that also enables thecompressor to operate when the externalair temperature increases abovestandard limits.A reduction in its start/stop cyclingfunction further contributes to increasingdata center availability, as well aslengthening the life of criticalcomponents.Extreme Flexibility for Open and Closed ArchitecturesSuitable For a Wide Range of InstallationsThe Ideal AirflowThe Liebert CRV addresses the cooling needs of both new and existing data centerspace, regardless of raised floor availability. It is ideally suited to data centers with up to50 racks, irrespective of heat load.EC Fans and compressors with variablecooling capacity, managed throughintegrated Vertiv ICOM Control,achieve flexible capacity and airflow forthe ideal operating conditions of ITequipment.Configuration FlexibilityThe Liebert CRV can be configured to perform temperature as well as humidity control.The Liebert CRV 300 mm and 600 mm width versions have been designed tospecifically meet the requirements of data centers in need of optimizing spaceoccupancy, as well as capital and running costs.4The Liebert CRV, designed usingadvanced, computer-aided dynamic fluidtechnology, delivers optimum airdistribution across rack installations. Theexceptional levels of air distribution havebeen proven as a result of wide-scalelaboratory and field testing.

Optimizing Total Cost of OwnershipDelivering Optimized ResultsEnergy Efficient CoolingIdeally suited for rack-level cooling and specifically designed for high return airtemperatures, the Liebert CRV optimizes air distribution and maximizes efficiency,delivering both cost and energy-related savings.The integrated Vertiv ICOM Control,equipped with up to 10 rack temperaturesensors, continuously monitors the heatload of the racks and regulates theLiebert CRV, ensuring it provides the mosteffective level of cooling while at the sametime delivering energy savings. Variablecapacity compressors modulate thecooling capacity, thus reducing inputpower with partial loads. EC Fantechnology regulates airflow and reducesfan input power.Efficiency is further enhanced through the use of the environmentally friendly R410Arefrigerant which ensures constant operation at the highest efficiency levels.The Liebert CRV is also designed to optimize installation and minimize start up,connection and labor investments. The unit is available for integration with existing racksor as a bundled solution combined with racks, UPS and monitoring capabilities.Customer Monitoring InterfacesMonitoring and Control Through Existing Network Via your Web BrowserThe Liebert CRV system can be fitted with a Vertiv monitoring card allowing fulladvantage to be taken of the Ethernet network and remote monitoring from yourcomputer desktop, network operations center or any network access simply utilizing astandard web browser. A standard web browser, via HTTP protocol or NetworkManagement System software via SNMP protocol, can be used to access theunit information.Monitoring Integration withExisting Building ManagementSystemIf required, by installing the optionalmonitoring card, the Liebert CRV can bemonitored and controlled by an existingBuilding Management System.The monitoring card provides Modbus,Bacnet and SNMP protocol support.5

Vertiv Liebert CRV from 10 to 60 kWData Center Rooms and Edge Locations With Up to 10 RacksThe Liebert CRV is installed in close proximity to servers for installations relating to network access cabinets and small computerrooms, regardless of the presence of a raised floor. The cooling unit, equipped with ten temperature sensors, modulates the airflow tomatch the real-time cooling requirements of the server.Direct Expansion SolutionWhen a chilled water system and physicalbuilding limitations restrict the installationof chillers, a direct expansion solution isthe ideal choice.In the event that internal and externalunits are installed in close proximity,direct expansion units are able to deliversignificant reductions in installationrelated time and costs. One of theScenario16N of RacksHeat LoadSpaceRaise FloorRecommended Solutionadvantages of the Liebert CRV with adirect expansion solution is theeco-friendly refrigerant R410A. The unitalso offers variable capacity compressor,which has the capability of immediatelymodulating and adapting its operationaccording to server cooling requirements.It significantly minimizes start/stopcycling, extending the life cycle of yourcooling equipment. The Liebert CRV,1 to 4Up to 20 kWFrom 5 m2 and 15 m2-Direct ExpansionScenario2operates with a significant return airtemperature, which contributes tomaximizing cooling capacity andincreasing efficiency without placingadditional stress on compressors.N of RacksHeat LoadSpaceRaise FloorRecommended SolutionUp to 10Up to 100 kWUp to 30 m2-Direct Expansion

Data Center Rooms and Density Areas with up to 50 RacksThe Liebert CRV's integration with Vertiv SmartAisleTM proves to be the ideal cold aisle containment approach for small datacenters requiring heat density increases. This solution has the added advantage of avoiding the installation of raised floors orheightening roof levels. CRV is also very well suited for the installation of high-density areas in data centers.Chilled Water Solution with Vertiv SmartAisle The Vertiv SmartAisle separates hotreturning air and cold supply air,optimizing the entire cooling solution. Byincreasing the room temperature, thefloor-mounted cooling units can besignificantly downsized, reducing theoverall level of investment. The higherEnergy Efficiency Ratio also improvesenergy savings and dramatically reducesrunning costs. The solution delivers thebest results when combined with theLiebert HPC - maximizing the freecoolingeffect and reducing running costs.Scenario3N of RacksHeat LoadSpaceRaise FloorRecommended SolutionCombining the Liebert CRV withthe Liebert HPC Freecooling Chillerfor Increased AdvantagesChilled water solutions are optimized toreduce energy consumption: With the use of EC Fans and the unit’sclose proximity to the racks, theLiebert CRV minimizes fan powerinput and can be regulated based onserver load levels. As it is specifically designed for high10 to 20Up to 200 kWUp to 50 m2-Chilled Waterreturn air temperatures, the LiebertCRV can operate at high chilled watertemperatures while maintainingcapacity, thus maximizing the chillerfreecooling effect.Scenario4N of RacksHeat LoadSpaceRaise FloorRecommended SolutionUp to 50Up to 300 kWUp to 100 m2-Chilled Water7

Vertiv Liebert CRV from 10 to 60 kWLiebert CRV Technical DataDIRECT EXPANSION (DX) MODELSCRD10Net Sensible Cooling CapacityNominal AirflowWeightHumidity ControlDimensions H x W x D[kW]m3/h[kg]CR025RA CR020RA/W CR035RA/W11.922.532004000220260NoYes2000x300x1100 (*)[mm]CHILLED WATER (CW) MODELS24.237.741705540335 / 350365 / 060RC54.057.072007758230230NoYes2000x300x1100 175Note: The performances shown above refer to an air inlet temperature of 38 C, condensing temperature for air and water-glycol cooled units of 45 C and a chilled water temperature of 7/12 C. (*) Unit available also with a2200 mm height and 1200 mm depth.STANDARD FEATURES AND OPTIONSDX VersionyyyyyyyyHyyyyyyyCW VersionHigh Efficiency Scroll/RotaryCompressor with CapacityModulationElectronic expansion valveEC plug fansR410A RefrigerantAdjustable modular baffle systemTop/Bottom connectionsLevelling feetFilters with up to F5 filtrationclass and clog filter switchElectrode humidifierElectric reheat 1-stageInternal condensate pumpUser Friendly DisplayRemote rack temperature sensorsMonitoring card for WEB,Modbus and BACnetTeamworking functionalityyyyyyyyyyyyyyEC plug fans3-way or 2-way valve with 0-10VactuatorAdjustable modular baffle systemTop / Bottom connectionsLevelling feetFilters with up to F5 filtrationclass and clog filter switchElectrode humidifierElectric reheat 1-stageInternal condensate pumpUser Friendly DisplayRemote rack temperature sensorsMonitoring card for WEB,Modbus and BACnetTeamworking functionalityDWADDITIONAL OPTIONSLiebert CRV 300 mm CWDX Versionyyyy8Additional remote racktemperature sensorsCompressor jacket (600mm models)Dual power supply with ATS onselected modelsOptional extension frame forheight 2200 mm and depth 1200 mmCW VersionyyyAdditional remote racktemperature sensorsDual power supply with ATSCooling Capacity Meter

Coupling Air Cooled Liebert CRV Units with Air Cooled CondensersOutdoor TemperatureModelCRD102CR025RACR020RACR035RAup to 35 Cup to 40 Cup to 45 1HCR51HCR76Condensers 023403340100591091091091091066759293102136[mm] / [kg][mm] / [kg][mm] / [kg][mm] / [kg][mm] / [kg][mm] / [kg]Coupling Water/Glycol Cooled Liebert CRV Units with DrycoolersModelCR20RWCR35RWAmbient Temperature up to 30 CAmbient Temperature up to 35 CAmbient Temperature up to 40 CStandard NoiseLow NoiseStandard NoiseLow NoiseStandard NoiseLow Noise1 x ESM0181 x EST0281 x ELM0181 x ELM0271 x EST0281 x EST0501 x ELM0271 x ELT0551 x EST0501 x EST0701 x ELT0471 x ELT065Dry Cooler 02Chilled Water CoolingChilled water cooling units may be coupled with Vertiv chillers (LiebertHPC or Liebert AFC series). The Liebert HPC chiller series offers a widerange of air cooled or water cooled solutions. Available with various noisethresholds and with freecooling modes, these units significantly enhancethe system's energy saving capabilities. Liebert HPC freecooling chillersare available from 40 kW to 1600 kW. The Liebert AFC, AdiabaticFreecooling Chillers, are available from 500 kW to 1700 kW and aredesigned to maximize data center efficiency and availability.9

Vertiv Liebert CRV from 10 to 60 kWThermal Management Data Center Infrastructure for Small and Large ApplicationsLiebert HPCWide range of high efficiency Freecooling Chillersfrom 40 kW to 1600 kW Designed specifically for data center applicationsand to work with Vertiv SmartAisle Premium energy efficiency versionUnique control capabilities with the VertivICOM Control.Liebert PDXLiebert PCWAvailable from 5-220 kW Premium energyefficiencyEurovent certifiedperformanceUnique controlcapabilities with theVertiv ICOM ControlLiebert EconoPhase available for the directexpansion system.Vertiv Environet AlertLiebert EFCIndirect evaporative freecooling unit leveraging on datacenter know-how. Available from 100 to 450 kW 10Unique control capabilities optimizing water andenergy costsSubstantial reductions and savings in terms ofelectrical infrastructure.Vertiv Environet Alert provides industry companies with critical facility monitoring softwarethat is affordable and easy to use. This solution delivers superior monitoring, alerting, trendingand data organization capabilities for all types of companies, helping them protect and growtheir business. Customers get monitoring, alerting and trending at a price that’s right fortheir business.

ServicesLiebert AFCThe Adiabatic Freecooling Chiller availablefrom 500-1700 kW Integrated adiabatic pad system High freecooling capacity 100% compressor back up.Vertiv SmartAisle Aisle containment Provides highest energyefficiency Works with any Liebert ThermalManagement unit.Vertiv supports entire criticalinfrastructures with the largestglobal service organization and anextensive service offering,enhancing network availability andensuring total peace of mind 24/7.Our approach to servicing criticalinfrastructure covers all aspects ofavailability and performance: fromsingle power and thermalmanagement equipment to entiremission-critical systems.The most comprehensive insurancefor business protection can beobtained with a service programfrom Vertiv which includes accessto Vertiv LIFE Services.Vertiv Life ServicesLiebert CRVRow-based high efficiency cooling units availablefrom 10-60 kW in DX and CW versions Full airflow and cooling capacity modulation tomatch server load and to save energy Best footprint capacity with the highest efficiency Six different control modes to ensuregreater flexibility.Liebert DCLClosed loop rack cooling Two different architectures:Closed LoopHybrid Loop Multiple combinations for up to 4 server racksAvailable as direct expansion or chilled water versionVertiv LIFE Services providesRemote Diagnostics and PreventiveMonitoring for UPS and thermalmanagement equipment.Vertiv LIFE Services deliversincreased uptime and operationalefficiency by enabling continuousmonitoring of your equipment,expert data analysis and fieldengineering expertise.Through the data transferred fromyour equipment via Vertiv LIFEServices, our Remote experts gainthe real-time insight andinformation needed to quicklyidentify, diagnose, and resolve anyirregularities that may arise inoperation, ultimately takingresponsibility for your criticalassets 24/7.11

Vertiv.com Vertiv Headquarters, 1050 Dearborn Drive, Columbus, OH, 43085, USA 2021 Vertiv Group Corp. All rights reserved. Vertiv and the Vertiv logo are trademarks or registered trademarks of Vertiv Group Corp. All other names and logos referred to are trade names, trademarks or registered trademarks of their respective owners. While everyprecaution has been taken to ensure accuracy and completeness here, Vertiv Group Corp. assumes no responsibility, and disclaims all liability, for damages resulting from use of this information or for any errors or omissions. Specifications, rebates and other promotionaloffers are subject to change at Vertiv’s sole discretion upon notice.MKA4L0UKCRV (R01/21)

monitor variations in heat loads and instantly deliver the most efficient and effective cooling necessary. Liebert CRV: Simple, Safe, Adaptable The Liebert CRV is a plug-and-play unit with the capability of addressing the needs of both open and contained applications. Cooling is provided at the server rack level rather than the room level. The