Vertiv Liebert EXM2 - Egypro

Transcription

Vertiv Liebert EXM2100 to 250 kWHighly Reliable and EfficientUPS designed to provideindustry-leading performance

Vertiv Liebert EXM2 100 to 250 kWAbout VertivVertiv brings together hardware, software, analytics and ongoing services to ensure its customers’vital applications run continuously, perform optimally and grow with their business needs. Vertivsolves the most important challenges faced by today’s data centers, communication networks andcommercial and industrial facilities with a portfolio of power, cooling, and IT infrastructure solutionsand services that extends from the cloud to the edge of the network. Headquartered in Columbus,Ohio, USA, Vertiv employs around 20,000 people and does business in more than 130 countries. Formore information, and for the latest news and content from Vertiv, visit Vertiv.com.Vertiv.comOUR PURPOSEWe believe there is a better way to meet the world’saccelerating demand for data - one driven by passionand innovation.US AND CANADAManuf. and Assembly Locations 7Service Centers 120 Service Field Engineers 850 TechnicalSupport/Response 120 CustomerExperience Centers/Labs 4LATIN AMERICAManuf. and Assembly Locations 1Service Centers 20 Service Field Engineers 300 Technical Support/Response 25 Customer Experience Centers/Labs 2OUR PRESENCEGLOBAL PRESENCEManuf. and Assembly Locations 19Service Centers 270 Service Field Engineers 2,700 Technical Support/Response 330 Customer Experience Centers/Labs 17EUROPE, MIDDLE EAST ANDAFRICAManuf. and Assembly Locations 5Service Centers 70 Service Field Engineers 600 Technical Support/Response 95 Customer Experience Centers/Labs 6ASIA PACIFICManuf. and Assembly Locations 6Service Centers 60 Service Field Engineers 950 Technical Support/Response 90 Customer Experience Centers/Labs 5

Liebert EXM2, The Next Generation Mid-size UPS for Mission-critical ApplicationsHIGHLIGHTSy Power Capacity: 100, 120, 160, 200and 250 kVA/kWy Three modes of operation toboost TCO and performancey Maximum efficiency in the Midsize range: Up to 98.8% inDynamic online mode and Up to97% in Double conversion modey Diverse application scenarios:In-Row, Room andAgainst-the-wally Flexible battery configuration:Lithium-Ion Batteriescompatibility & adapts to two wireconnectiony Symmetrical Power Factor (0.5leading to 0.5 lagging)Vertiv Liebert EXM2 drivesits evolution from the flagshipLiebert EXM/Liebert NXCwhich has been widelyrecognized as proven and highlystable performing UPS in itsrange and has been supportingover thousands of critical sitesacross the globe. Backed bydedicated research of Vertivexperts, Liebert EXM2 is poisedto lead in the industry withtechnologically advancementsimplanting all the next-genattributes. Machine learningbased- Three modes of energyoperation ensures the bestenergy credentials and assuresmaximum availability. ItsHealthcareRailway/Metroextraordinary Double conversionefficiency up to 97% ensuresremarkable operational costsavings. Our proven Dynamiconline mode delivers efficiencyup to 98.8% whilst compensatesthe load THDi, PF, main sags andswells, ensuring fast transferoutput performance. On top ofthis, Liebert EXM2 adopts to arange of infrastructure conditionsincluding Lithium-ion batterycompatibility and supports forthe leading power factor needsof modern server loads.Seamlessly operates up to 40 oCand can tolerate high ambienttemperature up to 50 oC withauto-derating.EnterprisesLight Industries Datacenter CPSS Work stations CriticalProcessEquipments Datacenter CPSS Work stationsy Scalable in parallel up to 1.5 MWy High ambient temperature up to50 C with auto-derating above40 Cy Reliability boosters: Robust airchannels, PCBs embedded withconformal coatingy Seismic complaint (with optionalkit) HealthDiagnosticEquipments Datacenter CPSS CommunicationSystem Automatic FareCollection CPSS OperationalControl Center3

Vertiv Liebert EXM2 100 to 250 kWFlexible And Optimized DesignAesthetic Design Adapts Well Into Your Infrastructural Needsy Ideal for In-the-Row serverrack applicationsy Suitable to be installedagainst the wall usingoptional top fan kity Suitable to be installedadjacent to the wally Compact and lightweightfootprint saves significantwhite floor space11Bypass Section2Power Section3Integrated SurgeProtection4Switch Assembly5Cable TerminationSection (Bottom asstandard)4Top cableTermination panel(Optional)56122663345100-160 kVA200-250 kVA

Highly Efficient and Lowest TCOLiebert EXM2 delivers anoutstanding Double conversionefficiency of up to 97%, whichfurther increases up to 98.8% withthe Dynamic online mode,consequently reducing operatingcosts and energy dissipation(kW) to a minimum. Thissignificantly minimizes theconsumption of the cooling system,providing an overall TCO reductionand rapid payback time.Furthermore, the Liebert EXM2 canoptimize efficiency at partial loadthereby attaining additional costsavings through the intelligentparalleling feature. The efficiencyand electricity cost savings ofLiebert EXM2 can be attributed to:Class 1 output performance undermost stringent conditions:y Latest generation IGBTyNetwork fault (voltagevariation, high/ low impedancemains failures)yLoad fault (short circuitdownstream of the UPS)y Advanced digital technologyand fast transferyType of load connected (PDUtransformer)The seamless activation of LiebertEXM2’s functioning modes ensuresthe highest level of efficiencywithout compromising powerquality and availability. TheDynamic online mode ensuresThe unit discriminates betweenvarious interferences and respondsrapidly, meanwhile also ensurescompatibility with downstreamequipment (such as Transformers,STS, mechanical loads, etc).y Adoption of a three-level T-typeconverter topologyy DC controlled fan speedy Intelligent paralleling modeManual BypassStatic BypassStatic BypassRectifierInverterBatteriesRectifierStatic aximum Power Control (VFI)Maximum Energy Saving (VFD)Provides the highest level of powerconditioning and protects the load fromall electrical network disturbances.Detects when conditioning is notrequired and allows the energy flow topass through the bypass line.Dynamic online mode: No more availability tradeoffwith efficiencyDynamic online mode is the latesthigh efficiency mode of operationoffered by Vertiv, developed forthose that do not want to trade offany level of availability forincremental gains in efficiency.Manual BypassManual Bypasswithin the IEC 62040 Class 1specification, thus offering thesame level of availability typicallyachieved in a double conversionoperating mode.Dynamic online mode is thereforeable to combine the superiorDynamic online mode enablesavailability of a Double conversionoperating efficiency up to 98.8%operating mode with the excellentwithout sacrificing availability. Inenergy cost savings of a highfact, while in this mode, the invertercan instantaneously assume the load efficiency mode for a reduced totalcost of ownership.and maintain the output voltageDynamic Online, High Efficiency &Power Conditioning (VI)Compensates the load THDi, PF, mainsags and swells, ensuring fast transferoutput performance.TYPICAL FUNCTIONING MODES OF A UPSSYSTEMDOUBLE CONVERSIONECO MODEMODE (VFI)(VFD)Maximum Availability withClass 1 UPSHighest level of Efficiencyup to 97%Can’t ensure perfect powerqualityAbove 99.2% EfficiencyNEW CONTROL MODEDYNAMIC ONLINE MODE(VI with VFI support)Maximum Availability withClass 1 UPSUp to 98.8% Efficiency5

Vertiv Liebert EXM2 100 to 250 kWRobust & Proven DesignInnovative Internal Air ChannelDesigned in such a way thatinternal hot air drives directlytowards heat sink withoutdistressing the PCB's and otherinternal sensitive circuits,improving the service life ofcomponents and UPS reliability.Conformal CoatingApplied as standard feature for allPCBs in Liebert EXM2. Its primarypurpose is to protect electronicsfrom environmental elements andcorrosion. The coating acts asboth a protective shield andinsulative material for a PCB.Higher Short Circuit HandlingCapacityDuring the short circuit, load will betransferred via bypass to clearhigher short circuit currents.Fuse is considered optionally toIntelligent Paralleling15%Six units at 15% load each 96% efficiency30%Liebert EXM2 IntelligentParalleling: three units at 30%load each 96.8% efficiencyclear short circuit capacity of up to65 kA.Tolerates Higher AmbientTemperaturesInternal components and circuitryof Liebert EXM2 are designed toseamlessly operate up to 40 Cwithout any capacity impact andfurther can sustain high ambienttemperature up to 50 C withauto-derating.Integrated Backfeed ProtectionBackfeed protection prevents anypotential risk from electric shockon the UPS mains and bypassinput AC terminals in the event of afailure of the rectifier and bypassstatic switch SCR. The controlcircuit includes output drycontacts that activates an internalisolating device (optional) uponbackfeed detection.Scalable up to 1.5 MW6 units of intelligent parallelinghelps to achieve maximumcapacity up to 1.5 MW. Comeswith Integrated Parallel and LBScommunication ports, and allowsingle touch to initiate inverter ON/OFF for all parallel connected UPSsystem.Symmetrical Power FactorCompatibilityLiebert EXM2 is fully adapted tomeet diverse system requirementsin terms of power capacity andredundancy allowing differentsystem designs.y Output Power Factor up to 1y No power derating from 0.5lagging to 0.5 leadingy Optimum space/power ratio

User Interface and Advanced DiagnosticLiebert EXM2 makes your missioncritical space a peaceful placethrough its advanced diagnosticcapability, measuring and logging,enhanced event analysis as well asan intelligent colored multilanguage touch screen display.Liebert EXM2 advanced DSPcontrol platform together with thepatented Vector Controltechnology enables increasedperformance of three-level powerconverters and real time control ofoutput power quality,guaranteeing continuousoperation and premiumprotection for your business.Bypass InputBatteryVoltage and frequencymeasurements.Status/values includingtemperature, cell voltage, capacityrun time and testing.Mains InputCurrent, voltage and frequencyvalues of the three input phases.Warning/faultAlerts of anomalies on bypass,rectifier, inverter, booster/charger,battery and load.Vertiv LIFE ServicesStatus of Vertiv LIFE Servicesconnections and calls.ToolsLCD settings and languageselection.Events logOutputDate and time of important UPSevents, alarms and other warnings.Voltage, current, frequency, andbattery measurements.MeasurementsVoltage, current and frequencyvalues of each internal functionalblock.7

Vertiv Liebert EXM2 100 to 250 kWLithium-ion Battery CompatibilityThe Liebert EXM2 is powered with most powerful & intelligent battery charger that enables to integrateseamlessly with any Lithium-ion chemistry batteries.Considering the benefits lithium-ion batteries providesover traditional battery deployments. Not only do usersenjoy the longer life, more cycles and fewerreplacements, they also benefit from the compact,smaller size and lower weight. Plus, the higheroperating temperature and lower maintenance add tothe savings.All these advantages directly impact IT facilities todrive an impressive total cost of ownership experience.Vertiv HPL lithium-ion cabinet battery with Liebert EXM2 UPSOur capabilities and processes come together toensure the UPS, batteries, monitoring, management,service and support offerings are orchestrated fordelivering on our customer expectations.Reduce Battery Replacement CyclesVRLA3-5 yearsLIB10-15 yearsVertiv leverages its DNA in critical systems to deliver alithium-ion battery system that is integrated seamlesslyinto the power chain.VRLA valve regulated lead-acidLIB data center lithium-ionFewer Facility DisruptionsLower Total Cost of OwnershipBenefits of Lithium-ion BatteriesLonger lifeVRLALIBSaves spaceVRLALIBWeighs lessVRLAMore cyclesLIBSaves cooling costVRLALIBLEADACIDLIBBattery ManagementSystemEXTERNALLEAD ACIDBUILT-IN LIB

Flexible Monitoring & Management OptionsHardware ConnectivityUser configurableInput and Output contactsLiebert EXM2 allows for themonitoring and control ofnetworked UPS through differentprotocol options:y Monitoring external breakersy Monitorning "on generator"signaly Permissive signal for SKRUy Trip external breakersThe integration of UPS withBuilding Monitoring andAutomation Systems via MODBUSRTU, MODBUS/TCP Protocols andenvironment sensors.The integration with synopticpanels via a dry contact board.IS-UNITY-DP CARDy Supports two simultaneousthird party protocols (SNMP,Modbus TCP or RTU (485),BACNet IP or MSTP (485)y WEB browsery EmailnotificationsIS-UNITY-LIFE CARDy SNMPIS-RELAY CARDy Dry contact alarm notificationy Email & SMS notifications(through LIFE Server)y Vertiv LIFE servicesy SMS text messagesy SN series sensor supporty Vertiv LIFE servicesDesigned for Easy Service and MaintenanceDesigned for ease of serviceLiebert EXM2 is designed to allow access tocable terminal blocks, switches and all thereplaceable components including power &bypass power modules and communicationsfrom the front side for both installation andmaintenance purposes.Modular Design and ConstructionCommon building blocks sub-assembly for aneasy on-site replacement and reduced MTTR.9

Vertiv Liebert EXM2 100 to 250 kWVERTIV LIFE Services Remote Diagnostic and Preventive MonitoringVertiv's service program isdesigned to ensure that yourcritical power protection system ismaintained in an optimum state ofreadiness at all times.The Vertiv LIFE Services remotediagnostic and preventivemonitoring service provides earlywarning of UPS conditions and outof tolerances. This allows effectiveproactive maintenance, fastincident response and remotetroubleshooting, giving customerscomplete security and peace ofmind. With Vertiv LIFE Services youwill benefit from:Uptime AssuranceConstant monitoring of UPSparameters, thus maximizing thesystem’s availability.First Time Fix RateFast Incident ResponsePro-active monitoring and datameasuring ensure that when ourcustomer engineers are dispatchedon-site, they arrive prepared forfirst time resolution.Vertiv LIFE Services allow forimmediate definition of the bestcourse of action, as a result of theregular communication betweenyour Liebert EXM2 system andour Vertiv LIFE Service centers.Proactive AnalysisFrom Vertiv LIFE Service centers,our experts proactively analyze thedata and trends of your equipment,to recommend actions to ensuretheir best performance.Minimized Total Cost ofOwnership of Your EquipmentThe continuous monitoring of allrelevant parameters in turnmaximizes unit performance,reduces on-site maintenance andextends the life of your equipment.ReportingYou will receive a comprehensivereport detailing the working orderof your equipment and itsoperational performance.

Technical SpecificationsNominal Ratings (kVA/kW)100 kVA120 kVA160 kVA200 kVA250 kVAInputNominal input voltage (V)380 / 400 / 415 (three-phase and sharing neutral with the bypass input)Input voltage range withoutbattery discharge (V)*228 to 478Nominal input frequency (Hz)50 / 60Input frequency range (Hz)40 to 70Upper limit: 10, 15, or 20, default: 15Lower limit: -10, -20, -30, -40, default: -20Bypass voltage tolerance (%)Bypass frequency tolerance (%) 10Input power factor (kW/kVA)0.99Input THDi* 3% (full load), 4% (half load)BatteryBattery bus voltage (VDC)Battery charger max. (A)360 to 528 , 2 Wire3045456075Output380 / 400 / 415(three-phase and sharing neutral with the bypass input)Nominal output voltage (V)Nominal output frequency (Hz)Nominal active power (kW)50 / 60100120THDv with 100% linear load (%)Inverter overload capacity1602002501 105 % for Continuous; 110% for 60min; 125 % 10 min; 150 % for 1 min; 150 % for 200msEfficiencyDouble conversion modeUp to 97%Dynamic online modeUp to 98.8%Eco modeUp to 99.2%Dimensions and weight1Dimensions (W x D x H), mm600 x 850 x 1600600 x 850 x 2000Shipping dimensions (W x D x H), mm800 x 1000 x 1800800 x 1000 x 2180Weight, kg315350350412447Shipping weight, kg345380380443478GeneralNoise at 1 m dBAAltitudeProtection level60621500 m no derating, 1500 to 3000 m derate power by 1 % per each 100 m increaseIP20IP21, IP31 optionalGeneral and safety requirements for UPSIEC 62040-1EMC requirements for UPSIEC 62040-2UPS classification according toIEC EN 62040-3VFI-SS-111Central Power Supply Systems (CPSS)applications*EN 50171Rail applications*EN 50121-1; EN 50121-5* Conditions apply1. Without side cabinet and top fan subassembly11

Vertiv.com 2021 Vertiv Group Corp. All rights reserved. Vertiv and the Vertiv logo are trademarks or registered trademarks of Vertiv Group Corp. While every precaution has been taken to ensure accuracy and completeness herein,Vertiv Group Corp. assumes no responsibility, and disclaims all liability, for damages resulting from use of this information or for any errors or omissions. Specifications are subject to change without EN

Liebert EXM/Liebert NXC- which has been widely recognized as proven and highly stable performing UPS in its range and has been supporting over thousands of critical sites dedicated research of Vertiv experts, Liebert EXM2 is poised to lead in the industry with technologically advancements implanting all the next-gen attributes. Machine learning