Vertiv Liebert GXT5 UPS

Transcription

Vertiv Liebert GXT5 UPS5 - 20 kVA 230VIntelligent and Efficient UPSfor Protection of YourMission-Critical Applications

Vertiv Liebert GXT5 5 - 20 kVA UPSLargest Rack Mount Capacity Available in an Intelligent,Efficient UPS for Protection of Mission-Critical ApplicationsThe Vertiv Liebert GXT5 UPS is anonline double conversion UPSsolution which offers premium poweroutage protection and continuouspower conditioning in a compact andflexible rack/tower form factor.The Liebert GXT5 single-phase UPSoperates with high power efficiency,making it ideally suited to protect criticalinfrastructure in both centralized and edgenetwork applications.Now available in higher capacity ratings of16 and 20 kVA the GXT5 UPS allows forhighly reliable single UPS installationsminimizing required rack space andsupporting more IT equipment loads.Scalable runtime options with matchingexternal battery cabinets offer additionalflexibility when extended uninterruptedpower is required. Plus, the Liebert GXT5provides battery health status andreplacement date prediction for intelligentbattery health management.The UPS system is easy to deploy andmaintain due to its user-friendly LCDinterface and remote managementcapabilities supported by the VertivRDU101 communications card whichmakes the Liebert GXT5 compatible withVertiv infrastructure management solutionssuch as LIFE Services, environmentalsensors, Vertiv Power Insight, and more.What's in the boxyUPSyTower StandyUSB CableyQuick Start GuideySafety ManualyPower Insight ManagementSoftware (free download fromVertiv.com)With market leading efficiency and unitypower factor operation, the Liebert GXT5will meet your critical application needs.And you can rest assured that yourbusiness is protected with this Vertivsolution that includes a standard, two-yearadvanced exchange product warranty.Liebert GXT5 FeaturesLeading UPS TechnologyEfficient and Green ProductSolutions Widey High output power factor up to 1.0y High efficiency in online modey Compact rack/tower designy Full-color graphic LCD with gravitysensing orientationy Energy Star 2.0 certifiedy Broad range of services and extendedwarrantyy External battery cabinets withauto-detectiony Parallel or redundant operationcapabilityy Battery health status and replacementdate predictiony Remote management, update, andconfiguration capabilitiesy Optimized thermal management andvariable speed fan for peak efficiencyand noise reductiony Even higher efficiency (up to 98%) inActive ECO modey Compliance with Restriction ofHazardous Substances (RoHS)directive and the Registration,Evaluation, Authorization andRestriction of Chemicals (REACH)regulationy Easy to install, configure and operatey Vertiv RDU101 networkcommunications card with advancedfeaturesy Compatibility with SN seriesenvironmental sensorsy Integrated dry-contacts withselectable definitiony Free Vertiv Power Insightmanagement softwarey Serial port for out-of-bandmanagement with Avocent serial consolesy Automatic internal bypass andexternal maintenance bypass options2

ECOAVertiv Liebert GXT5 Features1.0PFECOLCDCOLORBHigh power factor (1.0)More usable power enablesmore connected loads savingspace and costs.Compactrack/ towerCOLORdesignLCDSpace-saving UPSprovides rack spaceoptimization and y (up to 95%) in onlinemodeEnergy Star 2.0 certification. BHigherefficiency means an optimized energymanagement and lower heatdissipation, for energy savings andimprovedCOLORreliability.2 1LCDBParallel/redundantoperation capabilityBFor 10, 16 or 20 kVAmodels, configurations upto 2 1 redundancysupport maximumavailability and enablesgrowth as load demandincreases.1.0BLCDBPFECO0.9-1.0PFABColored graphicLCD with gravitysensitive orientationUser-friendly interfaceprovides insight to UPSstatus for easyBinstallation, configurationand operation.ECOA2 1COLORLCDBIntegrated BatteryWith self-test and .0PFCOLORALCDBEfficiency (up to 98%)in Active ECO modeA BSuperior protection withmaximum efficiency.BProductCOLOR warrantyComprehensivecoverageLCDthrough a standard two-yearadvanced exchange warranty.ABBattery Cabinets withauto-detection0.9-1.0PF the UPS is setBe confidentup correctly to reportavailable runtime when usedwith external battery cabinets.B3

Vertiv Liebert GXT5 5 - 20 kVA UPSHow You Benefit from the Vertiv Liebert GXT5 UPSDesigned for high availabilityy Higher power factor (1.0) ensures the connection of more loads and IT equipmenty Available rack mount maintenance bypass solution eliminates the need to power down connected equipment(16-20) kVAy Device can be swapped during operation without powering down connected equipment thanks to manualbypass pod integrated in the device (removable connetion box), (5-10) kVAy Optional output distribution POD for flexibility of connected equipment needsy Hot-swappable, user-replaceable battery modules minimize downtimey LIFE Services helps to enhance uptime, as well as operational efficiency with continuous remote monitoring,expert analysis, and proactive responsey Automatic programmable battery self-testUser-friendly installation and operationy Easy-to-read, gravity-sensing graphical color displayy Intuitive user interface for local configuration and managementy Support for the Vertiv suite of remote management tools (Vertiv Power Insight, RDU101 network interfacecard, and serial connectivity support)y Auto-detection of external battery cabinets enables faster deployment and accurate runtime informationy Remote UPS firmware upgrade capability ensures the UPS has the latest features and enhancementsLonger service life and runtime of the batteriesy Extended runtimes provided by the addition of external battery cabinetsy Improved battery care by temperature-compensated battery chargingy Intelligent battery health management ensures a longer service life (optimized battery maintenance andreplacement when needed)Optimized energy and capacity managementy Active ECO operating mode with up to 98% efficiencyy Efficiency in online double conversion mode up to 95%y Energy Star 2.0 certifiedSeamless connectivityy Four onboard, user-definable dry contact I/O for integration of support management systemsy Supports SNMP, web, and environmental sensors with the optional RDU101 communications cardy Serial connection for integration of Avocent ACS product or direct serial management and control of theUPS4

Power Assurance: Comprehensive Service Support for Critical SystemsProviding more than the standard warranty and extension program, this five-year protection program is valid for single-phase UPS unitshigher than 3 kVA. Purchased within six months from the equipment purchase date, the program includes:y Advance replacement or repair of faulty unit within eight working hours of incident ticket acknowledgement meaning amaximum of two business days after claim.y 100% coverage of electronic parts and failed batteries excluding battery misuse and/or reduced autonomy.y Free shipping from the following European countries: Austria, Belgium, Croatia, Czech Republic, France, Germany, Ireland, Italy,Luxemburg, Poland, Portugal, Slovakia, Spain, Sweden, Switzerland, The Netherlands, Turkey, and United Kingdom.y 24x7 access to professional helpline.y One Preventive Maintenance visit after the third year performed by a Vertiv technician.y Preventive Monitoring and Diagnostic Service purchasing the premier version of the package.Key Benefits:y Reduces the worry about critical equipment downtime.y Ensures rapid recovery in the event of failure (within 24-48 hours).UPS Above 3 kVAPower AssurancePower AssurancePremierPower Assurance PackageSturt-UpOptionalOptional24/724/7 8 working hours* * * 8 working hours* * *5 years(10 years withRenewal)5 years(10 years withRenewal)Technical Support HotlineParts IncludedLabour IncludedResponse TimePreventive MaintenanceLife ServicesContract DurationLiebert GXT55-20 nsion 1 yearWarrantyExtension 3 years5/6 kVARUPS-PA5-007 RUPS-PAP5-007 RUPS-WE1-007RUPS-WE3-0078/10 kXARUPS-PA5-008 RUPS-PAP5-008 RUPS-WE1-008RUPS-WE3-00816/20 kVARUPS-PA5-009 RUPS-PAP5-009 RUPS-WE1-009RUPS-WE3-009* Customer engineer or shipment of the new unit within 8 working hours from ticketacknowledgement** Includes 1 preventive maintenance after the third yearEUROPE, MIDDLE EAST AND AFRICAOUR PURPOSEManuf. and Assembly Locations 9We believe there is a better way to meetService Centers 70 the world’s accelerating demand forService Field Engineers 590 data - one driven by passion and innovation.Technical Support/Response 90 Customer Experience Centers/Labs 5OUR PRESENCEUS AND CANADALATIN AMERICAASIA PACIFICGLOBAL PRESENCEManuf. and Assembly Locations 13Manuf. and Assembly Locations 1Manuf. and Assembly Locations 5Manuf. and Assembly Locations 28Service Centers 100 Service Centers 20 Service Centers 60 Service Centers 250 Service Field Engineers 850 Service Field Engineers 240 Service Field Engineers 970 Service Field Engineers 2,650 Technical Support/Response 120 Technical Support/Response 20 Technical Support/Response 80 Technical Support/Response 300 Customer Experience Centers/Labs 4Customer Experience Centers/Labs 2Customer Experience Centers/Labs 5Customer Experience Centers/Labs 1655

Vertiv Liebert GXT5 5 - 20 kVA UPSTechnical Specifications 5-10 UXLEGXT5-10KIRT5UXLE5000 VA / 5000 W6000 VA / 6000 W8000 VA / 8000 W10,000 VA / 10,000 W16.9 24.8 8.5(430 630 394)16.9 24.8 8.5(430 630 394)16.9 24.8 8.5(430 630 394)16.9 24.8 8.5(430 630 394)156 (70.8)298 (135.2)298 (135.2)298 (135.2)50 or 60Hz(Factory Default is 50)50 or 60Hz(Factory Default is 50)50 or 60Hz(Factory Default is 50)50 or 60 Hz(factory-default is 50 Hz)Voltage Range230 VAC230 VAC230 VAC230 VACInput WiringHardwireHardwireHardwire (common or split bypass)Hardwire (common or split bypass)Hardwire2 (C19), 6 (C13)230 VAC50Hz or 60Hz, NominalHardwire2 (C19), 6 (C13)230 VAC50Hz or 60Hz, NominalHardwire4 (C19), 4(C13)230 VAC50Hz or 60Hz, NominalHardwire4 (C19), 4(C13)230 VAC50Hz or 60Hz, NominalSinewaveSinewaveSinewaveSinewaveRatings (VA/W)Dimensions, inches (mm)Unit W x D X HWeight, pounds (kg)UnitInput AC ParametersOperating Frequency,NominalOutput AC ParametersOutput ReceptaclesFactory-default VACFrequencyWaveform (On Battery)Utility (AC) ModeOverload 150% for Minimum 200mS; 125 - 150% for 60 150% for Minimum 200mS; 125 - 150% for 60 150% for Minimum 200mS; 125 - 150% for 60 150% for Minimum 200mS; 125 - 150% for 60seconds; 105-125% 5 Minutes; 105 % Continuous seconds; 105-125% 5 Minutes; 105 % Continuous seconds; 105-125% 5 Minutes; 105 % Continuous seconds; 105-125% 5 Minutes; 105 % ContinuousBatteryTypeValve-regulated, non-spillable, lead acidValve-regulated, non-spillable, lead acidValve-regulated, non-spillable, lead acidValve-regulated, non-spillable, lead acid7 Minutes5.5 Minutes3.5 Minutes2 Minutes18.5 Minutes14.5 Minutes9.5 Minutes7 Minutes19 Minutes14.5 Minutes9.5 Minutes7 Minutes48 Minutes38.5 Minutes26 Minutes19 Minutes 32 to 104 (0 to 40) (no derating) 32 to 104 (0 to 40) (no derating) 32 to 104 (0 to 40) (no derating) 32 to 104 (0 to 40) (no derating) 5 to 122 (-15 to 50) 5 to 122 (-15 to 50) 5 to 122 (-15 to 50) 5 to 122 (-15 to 50)0% to 95%,non-condensingUp to 10,000 ft (3,000 m) at 77 F (25 C)without derating0% to 95%,non-condensingUp to 10,000 ft (3,000 m) at 77 F (25 C)without derating0% to 95%, non-condensing0% to 95%, non-condensingUp to 10,000 ft (3,000 m) at 77 F (25 C)without deratingUp to 10,000 ft (3,000 m) at 77 F (25 C)without derating 55 dBA, at 1 meter from the rear 50 dBA, at 1 meter from the front or sides 55 dBA, at 1 meter from the rear 50 dBA, at 1 meter from the front or sides 55 dBA, at 1 meter from the rear 50 dBA, at 1 meter from the front or sides 55 dBA, at 1 meter from the rear 50 dBA, at 1 meter from the front or sidesSurge ImmunityIEC/EN EN61000-4-5, Level 3, Criteria AIEC/EN EN61000-4-5, Level 3, Criteria AIEC/EN EN61000-4-5, Level 3, Criteria AIEC/EN EN61000-4-5, Level 3, Criteria ATransportationISTA Procedure 1EISTA Procedure 1EISTA Procedure 1EISTA Procedure 1ESafetyIEC62040-1:2008 version, GS markIEC62040-1:2008 version, GS markIEC62040-1:2008 version, GS markIEC62040-1:2008 version, GS markEmissionsIEC/EN/AS 62040-2 2nd Ed (Cat 2)IEC/EN/AS 62040-2 2nd Ed (Cat 2)IEC/EN/AS 62040-2 2nd Ed (Cat 2)IEC/EN/AS 62040-2 2nd Ed (Cat 2)Std. 2 year; Opt. 1 and 3 year extensionStd. 2 year; Opt. 1 and 3 year extensionStd. 2 year; Opt. 1 and 3 year extensionStd. 2 year; Opt. 1 and 3 year extensionBackup Time (100%Load)Backup Time (50%Load) 1 External BatteryCabinet (100% Load) 1 External BatteryCabinet (50% Load)Environmental RequirementsOperating Temperature, F ( C)Storage Temperature, F ( C )Relative HumidityOperating ElevationAudible NoiseAgencyWarranty6

Technical Specifications 16-20 kVA16KIRT9UXLE20KIRT9UXLE16000 VA/16000 W20000 VA/20000 W16.9 24.8 15.5(430 630 394)16.9 24.8 15.5(430 630 394)298 (135.2)298 (135.2)50 or 60 Hz(factory-default is 50 Hz)50 or 60 Hz(factory-default is 50 Hz)288 VAC288 VACInput terminal blockInput terminal blockOutput ReceptaclesOutput terminal blockOutput terminal blockFactory-default VACFrequency230 VAC, 50 Hz230 VAC, 50 HzSinewaveSinewave 150% minimum 200 ms 150% minimum 200 msValve-regulated, non-spillable, lead acidValve-regulated, non-spillable, lead acid3.5 Minutes2.5 Minutes9.5 Minutes7 Minutes10 Minutes7 Minutes26.5 Minutes19.5 Minutes 32 to 104 (0 to 40) (no derating) 32 to 104 (0 to 40) (no derating) 5 to 104 (-15 to 40) 5 to 104 (-15 to 40)Relative Humidity0% to 95%, non-condensing0% to 95%, non-condensingOperating ElevationUp to 10,000 ft (3,000 m) at 77 F (25 C) without deratingUp to 10,000 ft (3,000 m) at 77 F (25 C) without derating 58 dBA, at 1 meter from the front 58 dBA, at 1 meter from the frontSurge ImmunityIEC/EN EN61000-4-5, Level 4, Criteria A; ANSI C62 41 Category BIEC/EN EN61000-4-5, Level 4, Criteria A; ANSI C62 41 Category BTransportationISTA Procedure 1EISTA Procedure 1ESafetyUL1778, c-UL listedUL1778, c-UL listedFCC Part 15 (Class A)FCC Part 15 (Class A)Std. 2 year; Opt. 1 and 3 year extensionStd. 2 year; Opt. 1 and 3 year extensionRatings (VA/W)Dimensions, inches (mm)Unit W x D X HWeight, pounds (kg)UnitInput AC ParametersOperating Frequency,NominalVoltage RangeInput WiringOutput AC ParametersWaveform (On Battery)Utility (AC) ModeOverloadBatteryTypeBackup Time(100% Load)Backup Time(50% Load) 1 External BatteryCabinet (100% Load) 1 External BatteryCabinet (50% Load)Environmental RequirementsOperating Temperature, F ( C)Storage Temperature, F ( C )Audible NoiseAgencyEmissionsWarranty7

Vertiv Liebert GXT5 5 - 20 kVA UPSAccessoriesVertiv VR RackVertiv Geist rPDUSupports a wide variety ofequipment and gives youthe flexibility you need witheasy installationReliably distributes power tothe rack, supportingdynamic data centeroperations and DCIMVertiv SwitchAirPrevents overheating ofnetwork switches bydirecting cool air to switchintakes, keeping hotexhaust air outVertiv ACS ConsoleEnables integrated remotemonitoring, out-of-bandmanagement, and IoTconnectivityRacks and enclosures: Support awide variety of equipment with theVertiv VR Rack including servers,storage, switches, routers, PDUs, UPSunits, console port servers, and KVMswitches.Rails and mounting hardware:Install equipment with a four-post railkit and hardware for mounting in a19- or 23-inch rack or choose a twopost telecom rack for front- ormid-chassis, wall, or Zero Uconfiguration.Rack mount PDUs: For basic orintelligent power distribution thathelps prevent overloaded circuits inthe data center, choose from productssuch as upgradable PDUs, inline powermeters, transfer switches, andmonitoring sensors.Extended battery modules:Vertiv KVM SwitchEnables single-point accessfor switching betweenmultiple computersVertiv Rack CoolingProvides energy-efficientcooling close to the ITequipment and UPS unitsVertiv Liebert GXT5Helps protect missioncritical equipment from allpower disturbances due toblackouts, brownouts, sags,surges or noise interference8Enable scalable runtime for supportduring extended power outagesituations by adding reliable powerand protection to new or existingdeployments.Environmental sensor: Maintainknowledge of remote environmentswith temperature, humidity and leakdetection, or monitor available drycontact sensors for security accesscontrol or smoke detection.

Available Accessories for the Vertiv Liebert GXT5 UPSExternal battery cabinets and replacement battery kitsUPSExternal battery cabinetsReplacement battery IT (x KIT (x KIT (x TKIT (x T (x T (x 1pcs)Network communications and environmental sensorsNetwork CommunicationsRDU101Intellislot web card for SNMP and web management. Supportsenvironmental sensors.IS-RELAYIntellislot Interface Kit for Relay ContactsEnvironmental Sensors (Compatible with optional Liebert SN-Z01network card RDU 101)Integrated cable with single temperature sensorSN-Z02Integrated cable with three temperature sensorsSN-Z03Integrated cable with three temperature and one humidity sensorsSN-TModular with single temperature sensorSN-THModular with single temperature and single humidity sensorSN-2DModular with two door contact inputsSN-3CModular with three dry contact inputsSN-L20Modular leak zone sensor with 20 foot cable (Liebert RDU-S only)Vertiv Power Insight Software ManagementVertiv Power Insight is a complimentary web-based softwaredesigned to monitor up to 100 Vertiv UPSs and rPDUsUPS manageability options9

Vertiv Liebert GXT5 5 - 20 kVA UPSLiebert GXT5 Rear Panel (5-6 kVA)External battery connectorC19 Output power receptaclesVertiv IntelliSlot for optionalSNMP/webcardREPOTerminal blockcommunicationDetachable Pod withintegrated maintenancebypassC13 output receptaclesOutput circuit breakersInput circuit breakerLiebert GXT5 Rear Panel (8-10 kVA)IntelliSlot for optionalSNMP/webcardExternal Battery Connector4 x C19 Output Receptacles(1 programmable outlet)Detachable POD withintegrated maintenancebypass4 x C13 Output Receptacles(1 programmable group)OutputCircuit Breakers10Input and Bypass CircuitBreakers

Liebert GXT5 Rear Panel (16-20 kVA)*Optional RDU101 NetworkCommunicationLocal Web and SNMP interface.Management and notificationacross networks.CommunicationsMultiple management options forlocal and remote setup configurationand control of the UPS any time.Optional Output PODMultiple options for local receptaclesC13/C19 options.Input ProtectionPrevent equipment damagefrom a short circuit ofoverload.Output ProtectionUPS and POD output circuitbreaker protection.External Battery CabinetConnectorScalable runtime in rack mountconfigurations. Longer runtimesfor critical work completion,work load migration and criticalequipment shutdown.Hardwire Output ConnectionOutput to panel board distributionor rack PDU for management andcontrol to rack level equipment.Hardwire Input ConnectionFor easy installation and reach toavailable power source.11

Vertiv.com Vertiv Headquarters, 1050 Dearborn Drive, Columbus, OH, 43085, USA 2021 Vertiv Group Corp. All rights reserved. Vertiv and the Vertiv logo are trademarks or registered trademarks of Vertiv Group Corp. All other names and logos referred to are trade names, trademarks or registered trademarks of their respective owners. While everyprecaution has been taken to ensure accuracy and completeness here, Vertiv Group Corp. assumes no responsibility, and disclaims all liability, for damages resulting from use of this information or for any errors or omissions. Specifications, rebates and other promotionaloffers are subject to change at Vertiv’s sole discretion upon notice.SL-70564 (R08/21)

such as LIFE Services, environmental sensors, Vertiv Power Insight, and more. With market leading efficiency and unity power factor operation, the Liebert GXT5 will meet your critical application needs. And you can rest assured that your business is protected with this Vertiv solution that includes a standard, two-year