Cisco UCS C220 M4 LFF Rack Server Spec Sheet

Transcription

This product has been discontinuedSpec SheetCisco UCS C220 M4High-Density Rack Server (Large Form Factor DiskDrive Model)CISCO SYSTEMS170 WEST TASMAN DR SAN JOSE, CA, 95134WWW.CISCO.COMPUBLICATION HISTORY REV E.16MAY 18, 2019

CONTENTSOVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3DETAILED VIEWS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Chassis Front View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4Chassis Rear View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5BASE SERVER STANDARD CAPABILITIES and FEATURES . . . . . . . . . . . . . . . . . 6CONFIGURING the SERVER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10STEP 1 VERIFY SERVER SKU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11STEP 2 SELECT LOCKING SECURITY BEZEL (OPTIONAL) . . . . . . . . . . . . . . . . . . . . . . . . . 12STEP 3 SELECT CPU(s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13STEP 4 SELECT MEMORY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15STEP 5 SELECT RAID CONTROLLERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21RAID Controller Options (internal HDD/SSD support) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21Cisco 12G SAS Modular RAID Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21SAS HBA (internal HDD/SSD/JBOD support) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21SAS HBA (external JBOD support) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21RAID Volumes and Groups . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21STEP 6 SELECT HARD DISK DRIVES (HDDs) or SOLID-STATE DRIVES (SSDs) . . . . . . . . . . . . . 27STEP 7 SELECT SED HARD DISK DRIVES (HDDs) or SOLID-STATE DRIVES (SSDs) . . . . . . . . . . 29STEP 8 SELECT PCIe OPTION CARD(s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31STEP 9 ORDER OPTIONAL NETWORK CARD ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . . 35STEP 10 ORDER POWER SUPPLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40STEP 11 SELECT AC POWER CORD(s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41STEP 12 ORDER TOOL-LESS RAIL KIT AND OPTIONAL REVERSIBLE CABLE MANAGEMENT ARM . 44STEP 13 SELECT NIC MODE (OPTIONAL) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45STEP 14 ORDER A TRUSTED PLATFORM MODULE (OPTIONAL) . . . . . . . . . . . . . . . . . . . . . 46STEP 15 ORDER CISCO FLEXIBLE FLASH SD CARD MODULE (OPTIONAL) . . . . . . . . . . . . . . . 48STEP 16 ORDER OPTIONAL USB 3.0 DRIVE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49STEP 17 SELECT OPERATING SYSTEM AND VALUE-ADDED SOFTWARE . . . . . . . . . . . . . . . . 50STEP 18 SELECT OPERATING SYSTEM MEDIA KIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53STEP 19 SELECT SERVICE and SUPPORT LEVEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54OPTIONAL STEP - ORDER RACK(s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59OPTIONAL STEP - ORDER PDU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60SUPPLEMENTAL MATERIAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61CHASSIS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62CPUs and DIMMs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63Physical Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63Memory Population Rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64DIMM Population Order . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65Recommended Memory Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66Additional DIMM Populations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68RAID Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69RAID Option ROM (OPROM) Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70Serial Port Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71Upgrade and Servicing-Related Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72Adding an Additional CPU (with CPU heat sink) or Replacing CPUs . . . . . . . . . . . . . . 73Motherboard Lithium Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73Thermal Grease (with syringe applicator) for CPU to Heatsink Seal . . . . . . . . . . . . . . 73Air Baffle Replacement Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74CPU Heat Sink Cleaning Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 742Cisco UCS C220 M4 High-Density Rack Server (Large Form Factor Disk Drive Model)

CONTENTSRACKS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75PDUs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77KVM CABLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78Motherboard USB and SD Ports, and RAID Card Backup Location . . . . . . . . . . . . . . . . . . . . 79TECHNICAL SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80Dimensions and Weight . . . . . . . . . . . . . . . . . . . . . . .Power Specifications . . . . . . . . . . . . . . . . . . . . . . . .Environmental Specifications . . . . . . . . . . . . . . . . . . .Compliance Requirements . . . . . . . . . . . . . . . . . . . . . . 80. . 81. . 82. . 83Discontinued EOL Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 853Cisco UCS C220 M4 High-Density Rack Server (Large Form Factor Disk Drive Model)

4Cisco UCS C220 M4 High-Density Rack Server (Large Form Factor Disk Drive Model)

OVERVIEWOVERVIEWThe Cisco UCS C220 M4 LFF rack server is the newest 2-socket, 1U rack server from Cisco, designed forboth performance and expandability over a wide range of storage-intensive infrastructure workloads fromweb serving to distributed database.The enterprise-class UFCS C220 M4 LFF server extends the capabilities of Cisco’s Unified Computing Systemportfolio in a 1U form factor with the addition of the Intel Xeon E5-2600 v3 and v4 series processor familythat deliver significant performance and efficiency gains. In addition, the UCS C220 M4 SFF server provides24 DIMM slots, up to 4 drives and 2 x 1 GbE LAN-on-motherboard (LOM) ports delivering outstanding levels ofdensity and performance in a compact 1U package.The C220 M4 SFF server includes a modular LAN on motherboard (mLOM) slot for installation of a CiscoVirtual Interface Card (VIC) or third-party network interface card (NIC) without consuming a PCI slot inaddition to 2 x 1 GbE embedded (on the motherboard) LOM ports. These features combine to provideoutstanding levels of internal memory and storage expandability along with exceptional performance.The Cisco UCS C240 M4 LFF server can be used standalone, or as part of the Cisco Unified ComputingSystem, which unifies computing, networking, management, virtualization, and storage access into a singleintegrated architecture enabling end-to-end server visibility, management, and control in both bare metaland virtualized environments.Figure 1Cisco UCS C220 M4 High-Density LFF Rack ServerFront ViewRear ViewCisco UCS Cisco UCS C220 M4 High-Density Rack Server (Large Form Factor Disk Drive Model)3

DETAILED VIEWSDETAILED VIEWSChassis Front ViewFigure 2 shows the front view of the Cisco UCS C220 M4 High-Density LFF Rack Server.Chassis Front View457681032HDD 019HDD 02HDD 03352974Figure 2HDD 041111Drives (up to four 3.5-inch drives)7Fan status LED2Pull-out asset tag8Temperature status LED3Operations panel buttons and LEDs9Power supply status LED4Power button/Power status LED10Network link activity LED5Unit identification button/LED11KVM connector (used with KVM cable thatprovides two USB 2.0, one VGA, and oneserial connector16System status LEDNotes . . .1. For more information about the KVM cable connection, see KVM CABLE, page 784Cisco UCS Cisco UCS C220 M4 High-Density Rack Server (Large Form Factor Disk Drive Model)

DETAILED VIEWSChassis Rear ViewFigure 3 shows the external features of the rear panel.Chassis Rear View12PCIe 01PCIe 02PSU 01PSU 02mLOM345678910352977Figure 3111PCIe riser 1/slot 17Serial port (RJ-45 connector)12PCIe riser 2/slot 28Two embedded (on the motherboard) Inteli350 GbE Ethernet controller portsLAN1 is left connector,LAN2 is right connector3Modular LAN-on-motherboard (mLOM) cardslot9VGA video port (DB-15)4Grounding-lug hole (for DC power supplies)10Rear Identification button/LED5USB 3.0 ports (two)11Power supplies (up to two, redundant as 1 1)61-Gb Ethernet dedicated management portNotes . . .1. For details of the serial port pinout, see Serial Port Details, page 71.Cisco UCS Cisco UCS C220 M4 High-Density Rack Server (Large Form Factor Disk Drive Model)5

BASE SERVER STANDARD CAPABILITIES and FEATURESBASE SERVER STANDARD CAPABILITIES and FEATURESTable 1 lists the capabilities and features of the base server. Details about how to configure the server fora particular feature or capability (for example, number of processors, disk drives, or amount of memory)are provided in CONFIGURING the SERVER, page 10.Table 1 Capabilities and FeaturesCapability/FeatureDescriptionChassisOne rack unit (1RU) chassisCPUOne or two Intel Xeon E5-2600 v3 or v4 series processor family CPUsChipsetIntel C610 series chipsetMemory24 slots for DDR4 registered DIMMs (RDIMMs) or load-reduced DIMMs(LRDIMMs)Multi-bit ErrorProtectionThis server supports multi-bit error protection.Embedded NICTwo embedded (on the motherboard) Intel i350 GbE ports, supporting thefollowing:Expansion slots Pre-Execution Boot (PXE boot) iSCSI boot Checksum and segmentation offload NIC teaming Riser 1 (controlled by CPU 1): One full-height profile, 3/4-length slot with x24 connector and x16lane Riser 2 (controlled by CPU 2): One half-height profile, half-length slot with x24 connector and x16lane, or Dedicated Cisco 12G SAS Modular RAID controller slot (see Figure 6 onpage 61) An internal slot is dedicated for the 12G SAS Modular RAID controllercard.Internal storage devicesDrives are installed into front-panel drive bays that provide hot-pluggableaccess. Large Form Factor (LFF) drives. Up to four 3.5-inch SAShot-swappable hard disk drives (HDDs)1.6 The server also contains one internal USB 3.0 port on the motherboardthat you can use with a an optional 16 GB USB thumb drive for additionalstorage UCS Storage Accelerators are also available. These PCIe flash storagedevices provide independent high-speed storage.Cisco UCS Cisco UCS C220 M4 High-Density Rack Server (Large Form Factor Disk Drive Model)

BASE SERVER STANDARD CAPABILITIES and FEATURESTable 1 Capabilities and Features (continued)Capability/FeatureDescriptionCisco Flexible FlashdrivesThe server supports up to two internal 32 GB or two internal 64 GB CiscoFlexible Flash drives (SD cards).The second SD card is blank and can be used to mirror the first SD card. Itcan be used to protect the Hypervisor Partition with RAID1.VideoThe Cisco Integrated Management Controller (CIMC) provides video using theMatrox G200e video/graphics controller:Integrated 2D graphics core with hardware acceleration InterfacesDDR2/3 memory interface supports up to 512 MB of addressable memory(8 MB is allocated by default to video memory) Supports display resolutions up to 1920 x 1200 16bpp @ 60Hz High-speed integrated 24-bit RAMDAC Single lane PCI-Express host interface running at Gen 1 speed Rear panel One DB15 VGA connector One RJ45 serial port connector Two USB 3.0 port connectors One RJ-45 10/100/1000 Ethernet management port, using CiscoIntegrated Management Controller (CIMC) firmware Two Intel i350 embedded (on the motherboard) GbE LOM ports One flexible modular LAN on motherboard (mLOM) slot that canaccommodate various interface cards Front panel One KVM console connector (supplies two USB 2.0 connectors, oneVGA DB15 connector, and one serial port (RS232) RJ45 connector) Various PCIe card ports (dependent on which cards are installed) Virtual Interface Card (VIC) ports Converged Network Adapter (CNA) ports Network Interface Card (NIC) ports Host Bus Adapter (HBA) portsCisco UCS Cisco UCS C220 M4 High-Density Rack Server (Large Form Factor Disk Drive Model)7

BASE SERVER STANDARD CAPABILITIES and FEATURESTable 1 Capabilities and Features (continued)Capability/FeatureStorage controllerDescription Cisco 12G SAS Modular RAID controller card with internal SASconnectivity. Supports up to 24 internal drives (note however that this server canbe configured with a maximum of 4 drives) Plugs into a dedicated RAID controller slot Can be purchased alone, or along with an onboard Flash-BackedWrite Cache (FBWC) upgrade option, as shown in the table belowRAID Card VersionSupported RAID LevelsOnboard TMMCacheUCSC-MRAID12G1JBOD, 0, 1, 10NoneUCSC-MRAID12G-5122JBOD, 0, 1, 5, 50512 MBUCSC-MRAID12G-1GB2JBOD, 0, 1, 10, 5, 6, 50, 601 GBUCSC-MRAID12G-2GB2JBOD, 0, 1, 10, 5, 6, 50, 602 GBUCSC-MRAID12G-4GB2JBOD, 0, 1, 10, 5, 6, 50, 604 GBNotes . . .1. Base RAID controller card (RAID 0, 1, 10 only)2. FBWC option for base RAID controller card (adding the FBWC option extendsthe RAID levels) Cisco 12 Gbps Modular SAS HBA with internal SAS connectivity Supports up to 24 internal drives (only 4 drives supported in thisserver) Plugs into a dedicated PCIe slot at the rear of the server (slot 1 ofriser 1) Supports JBOD only, not RAID, as shown in the below table.HBA Card VersionSupported RAID LevelsUCSC-SAS12GHBAJBOD only Cisco 9300-8E 12G SAS HBA with external SAS connectivity Provides 8 external SAS ports Plugs into a PCIe slot at the rear of the server No FBWC (cache) or cache power backup SAS 3.0 compliant8Cisco UCS Cisco UCS C220 M4 High-Density Rack Server (Large Form Factor Disk Drive Model)

BASE SERVER STANDARD CAPABILITIES and FEATURESTable 1 Capabilities and Features (continued)Capability/FeatureModular LAN onMotherboard (mLOM)slotDescriptionThe mLOM slot can flexibly accommodate the following cards: Cisco Virtual Interface Cards (VIC) Quad Port Intel i350 1GbE RJ45 Network Interface Card (NIC)NOTE: The four Intel i350 ports are provided on an optional card that plugs into the mLOM slot, and are separate from the two embedded (on the motherboard) LAN portsWoLThe 1-Gb Base-T Ethernet LAN ports support the wake-on-LAN (WoL)standard.Front PanelA front panel controller provides status indications and control buttonsPower subsystemUp to two 770 W (AC) hot swappable power supplies or two 1050 W (DC)power supplies. One is mandatory; one more can be added for 1 1redundancy.ACPIThis server supports the advanced configuration and power interface (ACPI)4.0 standard.FansChassis: Integrated managementprocessorSix hot-swappable fans for front-to-rear coolingBaseboard Management Controller (BMC) running Cisco IntegratedManagement Controller (CIMC) firmware.Depending on your CIMC settings, the CIMC can be accessed through the1-GbE dedicated management port, the 1-GbE LOM ports, or a Cisco virtualinterface card (VIC).Notes . . .1. The drives are available as both self-encrypted drives (SED) and non self-encrypted drives.Cisco UCS Cisco UCS C220 M4 High-Density Rack Server (Large Form Factor Disk Drive Model)9

CONFIGURING the SERVERCONFIGURING the SERVERFollow these steps to configure the Cisco UCS C220 M4 High-Density LFF Rack Server:10 STEP 1 VERIFY SERVER SKU, page 11 STEP 2 SELECT LOCKING SECURITY BEZEL (OPTIONAL), page 12 STEP 3 SELECT CPU(s), page 13 STEP 4 SELECT MEMORY, page 15 STEP 5 SELECT RAID CONTROLLERS, page 21 STEP 6 SELECT HARD DISK DRIVES (HDDs) or SOLID-STATE DRIVES (SSDs), page 27 STEP 7 SELECT SED HARD DISK DRIVES (HDDs) or SOLID-STATE DRIVES (SSDs), page 29 STEP 8 SELECT PCIe OPTION CARD(s), page 31 STEP 9 ORDER OPTIONAL NETWORK CARD ACCESSORIES, page 35 STEP 10 ORDER POWER SUPPLY, page 40 STEP 11 SELECT AC POWER CORD(s), page 41 STEP 12 ORDER TOOL-LESS RAIL KIT AND OPTIONAL REVERSIBLE CABLE MANAGEMENTARM, page 44 STEP 13 SELECT NIC MODE (OPTIONAL), page 45 STEP 14 ORDER A TRUSTED PLATFORM MODULE (OPTIONAL), page 46 STEP 15 ORDER CISCO FLEXIBLE FLASH SD CARD MODULE (OPTIONAL), page 48 STEP 16 ORDER OPTIONAL USB 3.0 DRIVE, page 49 STEP 18 SELECT OPERATING SYSTEM MEDIA KIT, page 53 STEP 19 SELECT SERVICE and SUPPORT LEVEL, page 54 OPTIONAL STEP - ORDER RACK(s), page 59 OPTIONAL STEP - ORDER PDU, page 60Cisco UCS Cisco UCS C220 M4 High-Density Rack Server (Large Form Factor Disk Drive Model)

CONFIGURING the SERVERSTEP 1VERIFY SERVER SKUVerify the product ID (PID) of the server as shown in Table 2.Table 2 PID of the C220 M4 High-Density LFF Rack Base ServerProduct ID (PID)DescriptionUCSC-C220-M4LUCS C220 M4 LFF, no CPU, memory, HDD, power supply, SD cards, PCIe cards, ortool-less rail kitUCSC-10PK-C220M41MULTIPACK:10-Pk C220 M4 w/blanking panels, packagingNotes . . .1. This selection allows you to order a quantity of 10 servers, all packaged together.The Cisco C220 M4 server: Does not include power supply, CPU, memory, hard disk drives (HDDs), SD cards, rail kit,plug-in PCIe cards.NOTE: Use the steps on the following pages to configure the server withthe components that you want to include.Cisco UCS Cisco UCS C220 M4 High-Density Rack Server (Large Form Factor Disk Drive Model)11

CONFIGURING the SERVERSTEP 2SELECT LOCKING SECURITY BEZEL (OPTIONAL)An optional locking bezel can be mounted to the front of the chassis to prevent unauthorizedaccess to the drives.Select the locking bezel from Table 3.Table 3 Locking Bezel OptionProduct ID (PID)UCSC-BZL-C220M412DescriptionC220 M4 Security BezelCisco UCS Cisco UCS C220 M4 High-Density Rack Server (Large Form Factor Disk Drive Model)

CONFIGURING the SERVERSTEP 3SELECT CPU(s)The standard CPU features are: Intel Xeon E5-2600 v3 and v4 series processor family CPUsIntel C610 series chipsetCache size of up to 55 MBSelect CPUsThe available CPUs are listed in Table 4.Table 4 Available Intel CPUsProduct ID )CoresQPIHighestDDR4 DIMMClockSupport(MHz)1E5-2600 v4 Series Processor Family CPUsUCS-CPU-E52699AEE5-2699A v42.4014555229.6 GT/s2400UCS-CPU-E52699EE5-2699 v42.2014555229.6 GT/s2400UCS-CPU-E52698EE5-2698 v42.2013550209.6 GT/s2400UCS-CPU-E52697AEE5-2697A v42.6014540169.6 GT/s2400UCS-CPU-E52697EE5-2697 v42.3014545189.6 GT/s2400UCS-CPU-E52695EE5-2695 v42.1012045189.6 GT/s2400UCS-CPU-E52690EE5-2690 v42.6013535149.6 GT/s2400UCS-CPU-E52683EE5-2683 v42.1012040169.6 GT/s2400UCS-CPU-E52680EE5-2680 v42.4012035149.6 GT/s2400UCS-CPU-E52667EE5-2667 v43.201352589.6 GT/s2400UCS-CPU-E52660EE5-2660 v42.0010535149.6 GT/s2400UCS-CPU-E52650EE5-2650 v42.2010530129.6 GT/s2400UCS-CPU-E52650LEE5-2650L v41.706535149.6 GT/s2400UCS-CPU-E52643EE5-2643 v43.401352069.6 GT/s2400UCS-CPU-E52640EE5-2640 v42.409025108.0 GT/s2133UCS-CPU-E52637EE5-2637 v43.501351549.6 GT/s2400UCS-CPU-E52630EE5-2630 v42.208525108/0 GT/s2133UCS-CPU-E52630LEE5-2630L v41.805525108.0 GT/s2133UCS-CPU-E52623EE5-2623 v42.60851048.0 GT/s2133UCS-CPU-E52620EE5-2620 v42.10852088.0 GT/s2133UCS-CPU-E52609EE5-2609 v41.70852086.4 GT/s1866UCS-CPU-E52658EE5-2658 v42.3010535149.6 GT/s2400UCS-CPU-E52680DE5-2680 v32.5012030128.0 GT/s2133UCS-CPU-E52640DE5-2640 v32.60902086.4 GT/s1866UCS-CPU-E52620DE5-2620 v32.40851566.4 GT/s1866Cisco UCS Cisco UCS C220 M4 High-Density Rack Server (Large Form Factor Disk Drive Model)13

CONFIGURING the SERVERTable 4 Available Intel CPUs DE5-2609 v3UCS-CPU-E52658DE5-2658 v3Product ID 2QPI8.0 GT/sHighestDDR4 DIMMClockSupport(MHz)116002133Notes . . .1. If higher or lower speed DIMMs are selected than what is shown in the table for a given CPU, the DIMMs will beclocked at the lowest common denominator of CPU clock and DIMM clock.Approved Configurations(1) 1-CPU configurations: Select any one CPU listed in Table 4 on page 13.(2) 2-CPU Configurations: Select two identical CPUs from any one of the rows of Table 4 on page 13.Caveats You can select either one processor or two identical processors. The selection of 1 or 2 CPUs depends on the desired server functionality. See the followingsections: 14—STEP 4 SELECT MEMORY, page 15 (memory mirroring section)—STEP 8 SELECT PCIe OPTION CARD(s), page 31—Table 9 on page 25 (RAID support table)For optimal performance, select DIMMs with the highest clock speed for a given processor(see Table 4 on page 13). If you select DIMMs whose speeds are lower or higher than thatshown in the tables, suboptimal performance will result.Cisco UCS Cisco UCS C220 M4 High-Density Rack Server (Large Form Factor Disk Drive Model)

CONFIGURING the SERVERSTEP 4SELECT MEMORYThe standard memory features are: —Clock speed: 2400 or 2133 MHz—Ranks per DIMM: 1, 2, 4, or 8—Operational voltage: 1.2 V—Registered ECC DDR4 DIMMs (RDIMMs) or load-reduced DIMMs (LRDIMMs)Memory is organized with four memory channels per CPU, with up to three DIMMs perchannel, as shown in Figure 4.Slot 2Slot 3Slot 3Slot 2Slot 1C220 M4 LFF Memory OrganizationSlot 1Figure 4DIMMsA1A2A3E3E2E1Chan AB1B2Chan EB3Chan BC1C2CPU 2Chan CD1D2F2F1G3G2G1H3H2H1Chan FCPU 1C3F3Chan GD3Chan DChan H24 DIMMS1.5 TB maximum memory (with 64 GB DIMMs)4 memory channels per CPU,up to 3 DIMMs per channelCisco UCS Cisco UCS C220 M4 High-Density Rack Server (Large Form Factor Disk Drive Model)15

CONFIGURING the SERVERSelect DIMMs and Memory MirroringSelect the memory configuration and whether or not you want the memory mirroring option.The available memory DIMMs and mirroring option are listed in Table 5.NOTE: When memory mirroring is enabled, the memory subsystem simultaneouslywrites identical data to two channels. If a memory read from one of the channelsreturns incorrect data due to an uncorrectable memory error, the systemautomatically retrieves the data from the other channel. A transient or soft error inone channel does not affect the mirrored data, and operation continues unless thereis a simultaneous error in exactly the same location on a DIMM and its mirroredDIMM. Memory mirroring reduces the amount of memory available to the operatingsystem by 50% because only one of the two populated channels provides data.Table 5 Available DDR4 DIMMsProduct ID (PID)PID DescriptionVoltageRanks/DIMM2400-MHz DIMM OptionsUCS-ML-1X644RV-A64GB DDR4-2400-MHz LRDIMM/PC4-19200/quad rank/x41.2 V4UCS-MR-1X322RV-A32GB DDR4-2400-MHz RDIMM/PC4-19200/dual rank/x41.2 V2UCS-MR-1X161RV-A16GB DDR4-2400-MHz RDIMM/PC4-19200/single rank/x41.2 V1UCS-MR-1X081RV-A8 GB DDR4-2400-MHz RDIMM/PC4-19200/single rank/x41.2 V1Memory Mirroring OptionN01-MMIRRORMemory mirroring optionApproved Configurations(1) 1-CPU configuration without memory mirroring: Select from 1 to 12 DIMMs. Refer to Memory Population Rules, page 64, for more detailedinformation.(2) 1-CPU configuration with memory mirroring: TotalNumberofDIMMs16Select 2, 4, 8, or 12 identical DIMMs. The DIMMs will be placed by the factory as shown in thefollowing table.CPU 1 DIMM Placement in Channels(for identical dual-rank DIMMs for 3DPC or identical quad-rank DIMMs for 2DPC)Blue SlotsBlack SlotsWhite SlotsCisco UCS Cisco UCS C220 M4 High-Density Rack Server (Large Form Factor Disk Drive Model)

CONFIGURING the SERVER2(A1, B1)——4(A1,B1); (C1,D1)——8(A1,B1); (C1,D1)(A2,B2); (C2,D2)12(A1,B1); (C1,D1)(A2,B2); (C2,D2) (A3,B3); (C3,D3)Select the memory mirroring option (N01-MMIRROR) as shown in Table 5 on page 16.(3) 2-CPU configuration without memory mirroring: Select from 1 to 12 DIMMs per CPU. Refer to Memory Population Rules, page 64, for moredetailed information.(4) 2-CPU configuration with memory mirroring: NumberofDIMMsper CPUSelect 2, 4, 8, or 12 identical DIMMs per CPU. The DIMMs will be placed by the factory asshown in the following table.CPU 1 DIMM Placement in Channels(for identical dual-rank DIMMs for 3DPC oridentical quad-rank DIMMs for 2DPC)CPU 2 DIMM Placement in Channels(for identical dual-rank DIMMs for 3DPC oridentical quad-rank DIMMs for 2DPC)Blue SlotsBlack SlotsWhite SlotsBlue SlotsBlack SlotsWhite Slots2(A1, B1)——(E1, ��8 (CPU1)and 2, 2,D2)(A3, B3)(C3, tes . . .1. Not recommended (for performance reasons) Select the memory mirroring option (N01-MMIRROR) as shown in Table 5 on page 16.NOTE: System performance is optimized when the DIMM type and quantity are equalfor both CPUs, and when all channels are filled equally across the CPUs in the server.Cisco UCS Cisco UCS C220 M4 High-Density Rack Server (Large Form Factor Disk Drive Model)17

CONFIGURING the SERVERCaveats System speed is dependent on how many DIMMs are populated per channel and the CPUDIMM speed support. See Table 6 and Table 7 on page 19 for details.Table 6 2133-MHz DIMM Memory Speeds with Different CPUs1600-MHz Capable CPU 1866-MHz Capable CPU 2133-MHz Capable CPUDIMM Speed DPCLRDIMM(QR)RDIMM LRDIMM(8R, DR, SR) (QR)RDIMM LRDIMM(8R, DR, SR) (QR)RDIMM (8R, DR, SR)2133 66213321333DPC160016001600160018661866 (32 GB RDIMMs and16 GB DIMMs)1600 (64 GB TSV RDIMMs,8 GB RDIMMs)18Cisco UCS Cisco UCS C220 M4 High-Density Rack Server (Large Form Factor Disk Drive Model)

CONFIGURING the SERVERTable 7 2400-MHz DIMM Memory Speeds with Different v4 CPUsDIMM and CPUFrequenciesLRDIMM(QRx4) - 64 GB1RDIMM (2Rx4) - 32 GBLRDIMM (QRx4) - 32 GB1RDIMM (SRx4) - 16 GBRDIMM (SRx4) - 8 GB1.2 V1.2 V1.2 V1.2 V1.2 V1DPC2400 MHz2400 MHz2400 MHz2400 MHz2400 MHz2DPC22400 MHz2400 MHz2400 MHz2400 MHz2400 MHz3DPC2133 MHz1866 MHz2133 MHz2133 MHz2133 MHz1DPC2133 MHz2133 MHz2133 MHz2133 MHz2133 MHz2DPC2133 MHz2133 MHz2133 MHz2133 MHz2133 MHz3DPC1866 MHz1866 MHz1866 MHz1866 MHz1600 MHz1DPC1866 MHz1866 MHz1866 MHz1866 MHz1866 MHz2DPC1866 MHz1866 MHz1866 MHz1866 MHz1866 MHz3DPC1866 MHz1600 MHz1866 MHz1600 MHz1600 MHzDPCDIMM 2400 MHz CPU 2400 MHzDIMM 2400 MHz CPU 2133 MHzDIMM 2400 MHz CPU 1866 MHzNotes . . .1. Available at a future date2. When you mix 2400 MHz RDIMMs of different sizes (for example, 8x32GB 8x16GB), the memory speed clocksone step down to 2133 MHz. The C220 M4 server supports four different memory reliability, availability, andserviceability (RAS) modes:—Independent Channel Mode—Mirrored Channel Mode—Lockstep Channel ModeBelow are the system level RAS Mode combination limitations:—Mixing of Independent and Lockstep channel mode is not allowed per platform.—Mixing of Non-Mirrored and Mirrored mode is not allowed per platform.—Mixing of Lockstep and Mirrored mode is not allowed per platform. Do not mix RDIMMs with LRDIMMs Do not mix 64GB DDR4-2133-MHz TSV-RDIMMs with any other DIMMs Single-rank DIMMs can be mixed with dual-rank DIMMs in the same channel Do not mix quad-rank DIMMs with single- or dual-rank DIMMs in the same channel For best performance, observe the following:Cisco UCS Cisco UCS C220 M4 High-Density Rack Server (Large Form Factor Disk Drive Model)19

CONFIGURING the SERVER—DIMMs with different timing parameters can be installed on different slots within thesame channel, but only timings that support the slowest DIMM will be applied to all.As a consequence, faster DIMMs will be operated at timings supported by the slowestDIMM populated.—When one DIMM is used, it must be populated in DIMM slot 1 (farthest away from theCPU) of a given channel.—When single, dual or quad rank DIMMs are populated for 2DPC or 3DPC, alwayspopulate the higher number rank DIMM first (starting from the farthest slot). For a3DPC example, first populate with quad-rank DIMMs in the DIMM slot 1. Thendual-rank DIMMs in the DIMM 2 slot. Then single-rank DIMMs in the DIMM 3 slot. DIMMs for CPU 1 and CPU 2 (when populated) must always be configured identically. When using mirroring, DIMMs must be installed in identical pairs across paired DDR4 buses.That is, mirrored pairs in channels A and B must be identical and pairs in channels C and Dmust be identical. However, the DIMMs used in channels A and B can be different from thosein channels C and D. Memory mirroring reduces the amount of available memory by 50% (quantity of DIMMs mustbe even for mirroring). Non-ECC DIMMs are not supported. Cisco memory from previous generation servers (DDR3) is not compatible with this serverFor more information regarding memory, see CPUs and DIMMs, page 63.20Cisco UCS Cisco UCS C220 M4 High-Density Rack Server (Large Form Factor Disk Drive Model)

CONFIGURING the SERVERSTEP 5SELECT RAID CONTROLLERSRAID Controller Options (internal HDD/SSD support)Cisco 12G SAS Modular RAID ControllerYou can choose the Cisco

CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR SAN JOSE, CA, 95134 REV E.16 MAY 18, 2019 WWW.CISCO.COM Spec Sheet Cisco UCS C220 M4 High-Density Rack Server (Large Form Factor Disk Drive Model) This product has been discontinued