Spec SheetCisco UCS C220 M5Server (Large Form Factor DiskDrive Model)CISCO SYSTEMS170 WEST TASMAN DR SAN JOSE, CA, 95134WWW.CISCO.COMPUBLICATION HISTORY REV A.2AUGUST 28, 2017

CONTENTSOVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2DETAILED VIEWS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Chassis Front View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3Chassis Rear View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4BASE SERVER STANDARD CAPABILITIES and FEATURES . . . . . . . . . . . . . . . . . 5CONFIGURING the SERVER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . TEPSTEPSTEPSTEPSTEPSTEPSTEPSTEP1 VERIFY SERVER SKU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92 SELECT CPU(s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103 SELECT MEMORY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134 SELECT RAID CONTROLLERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16RAID Controller Options (internal HDD/SSD support) . . . . . . . . . . . . . . . . . . . . . . . . 16Embedded Software RAID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16Cisco 12G SAS RAID controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16Cisco 12G SAS HBA (internal HDD/SSD/JBOD support) . . . . . . . . . . . . . . . . . . . . . . . 16RAID Volumes and Groups . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 165 SELECT DRIVES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 206 SELECT PCIe OPTION CARD(s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 237 ORDER POWER SUPPLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 268 SELECT POWER CORD(s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 279 ORDER TOOL-LESS RAIL KIT AND OPTIONAL REVERSIBLE CABLE MANAGEMENT ARM . 3010 SELECT MANAGEMENT CONFIGURATION (OPTIONAL) . . . . . . . . . . . . . . . . . . . . 3111 SELECT SERVER BOOT MODE (OPTIONAL) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3212 ORDER SECURITY DEVICES (OPTIONAL) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3313 SELECT LOCKING SECURITY BEZEL (OPTIONAL) . . . . . . . . . . . . . . . . . . . . . . . . 3414 ORDER CISCO SD CARD MODULE (OPTIONAL) . . . . . . . . . . . . . . . . . . . . . . . . . . 3515 ORDER M.2 SATA SSD (OPTIONAL) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3616 ORDER INTERNAL MICRO-SD CARD MODULE (OPTIONAL) . . . . . . . . . . . . . . . . . . 3717 ORDER OPTIONAL USB 3.0 DRIVE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3818 SELECT OPERATING SYSTEM AND VALUE-ADDED SOFTWARE . . . . . . . . . . . . . . . . 3919 SELECT OPERATING SYSTEM MEDIA KIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4520 SELECT SERVICE and SUPPORT LEVEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46OPTIONAL STEP - ORDER RACK(s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52OPTIONAL STEP - ORDER PDU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53SUPPLEMENTAL MATERIAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54CHASSIS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56RAID Option ROM (OPROM) Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57Serial Port Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58Upgrade and Servicing-Related Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59RACKS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60PDUs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61KVM CABLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62TECHNICAL SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63Dimensions and Weight . . . . . . . . . . . . . . . . . . . . . . .Power Specifications . . . . . . . . . . . . . . . . . . . . . . . .Environmental Specifications . . . . . . . . . . . . . . . . . . .Compliance Requirements . . . . . . . . . . . . . . . . . . . . .1. . 63. . 64. . 67. . 69Cisco UCS C220 M5 Rack Server (Large Form Factor Disk Drive Model)

OVERVIEWOVERVIEWThe UCS C220 M5 LFF server extends the capabilities of Cisco’s Unified Computing System portfolio in a 1Uform factor with the addition of the Intel Xeon Processor Scalable Family, 24 DIMM slots for 2666MHzDIMMs and capacity points up to 128GB, two 2 PCI Express (PCIe) 3.0 slots, up to four SAS/SATA hard diskdrives (HDDs) or solid state drives (SSDs), and one dedicated internal slot for a 12G SAS storage controllercard.The C220 M5 LFF server includes a dedicated internal modular LAN on motherboard (mLOM) slot forinstallation of a Cisco Virtual Interface Card (VIC) or third-party network interface card (NIC) withoutconsuming a PCI slot in addition to 2 x 10 Gbase-T Intel x550 embedded (on the motherboard) LOM ports.The Cisco UCS C220 M5 server can be used standalone, or as part of the Cisco Unified Computing System,which unifies computing, networking, management, virtualization, and storage access into a singleintegrated architecture enabling end-to-end server visibility, management, and control in both bare metaland virtualized environments.Figure 1Cisco C220 M5 LFF Rack ServerFront ViewRear ViewCisco UCS C220 M5 Rack Server (Large Form Factor Disk Drive Model)2

DETAILED VIEWSDETAILED VIEWSChassis Front ViewFigure 2 shows the front view of the Cisco C220 M5 LFF Rack Server.Figure 21Chassis Front ViewDrive bays 1 – 4 support SAS/SATA harddrives and solid state drives (SSDs).7Temperature status LEDA size-converter drive sled is required tohold 2.5-inch SSDs.2Drive bays 1 and 2 support 2.5-inch (SFF)NVMe PCIe SSDs.8Power supply status LED3Power button/Power status LED9Network link activity LED4Unit identification button/LED10KVM connector (used with KVM cable thatprovides two USB 2.0, one VGA, and oneserial connector15System status LED11Pull-out asset tag6Fan status LEDNotes:1. For more information about the KVM cable connection, see KVM CABLE, page 623Cisco UCS C220 M5 Rack Server (Large Form Factor Disk Drive Model)

DETAILED VIEWSChassis Rear ViewFigure 3 shows the external features of the rear panel.Figure 3Chassis Rear View1Modular LAN-on-motherboard (mLOM) cardslot7Rear Identification button/LED2USB 3.0 ports (two)8Power supplies (up to two, redundant as 1 1)3Two embedded (on the motherboard) Intelx550 10Gbase-T Ethernet controller ports9PCIe riser 2/slot 2 (x16); includes PCIe cableconnectors for SFF NVMe SSDs (x8)LAN1 is left connector,LAN2 is right connector4VGA video port (DB-15)10PCIe riser 1/slot 1 (x16)51-Gb Ethernet dedicated management port11Threaded holes for dual-hole grounding lug6Serial port (RJ-45 connector)1Notes:1. For details of the serial port pinout, see Serial Port Details, page 58.Cisco UCS C220 M5 Rack Server (Large Form Factor Disk Drive Model)4

BASE SERVER STANDARD CAPABILITIES and FEATURESBASE SERVER STANDARD CAPABILITIES and FEATURESTable 1 lists the capabilities and features of the base server. Details about how to configure the server fora particular feature or capability (for example, number of processors, disk drives, or amount of memory)are provided in CONFIGURING the SERVER, page 8.Table 1 Capabilities and psetMemoryOne rack unit (1RU) chassisOne or two Intel Xeon processor scalable family CPUsIntel C620 series chipset24 slots for registered DIMMs (RDIMMs), load-reduced DIMMs (LRDIMMs), orthrough silicon via (TSV) DIMMsThis server supports multi-bit error protection.Multi-bit ErrorProtectionVideoThe Cisco Integrated Management Controller (CIMC) provides video using theASPEED Pilot 4 video/graphics controller:Integrated 2D graphics core with hardware acceleration DDR4 memory interface supports up to 16 MB directly accessible fromhost and entire DDR memory indirectly accessible from host processor. Supports all display resolutions up to 1920 x 1200 x 32bpp resolution at60Hz High speed Integrated 24-bit RAMDAC Single lane PCI-Express host interfaceeSPI processor to BMC supportAn optional SATA interposer board for up to four SATA-only drives.Up to two of the following hot-swappable power supplies: SATA Interposer BoardPower subsystemWoLFront PanelACPIFans5 770 W (AC) 1050 W (AC) 1050 W (DC)One power supply is mandatory; one more can be added for 1 1redundancy.The Intel x550 10Gbase-T Ethernet LAN ports support the wake-on-LAN (WoL)standard.A front panel controller provides status indications and control buttonsThis server supports the advanced configuration and power interface (ACPI)4.0 standard. Seven hot-swappable fans for front-to-rear coolingCisco UCS C220 M5 Rack Server (Large Form Factor Disk Drive Model)

BASE SERVER STANDARD CAPABILITIES and FEATURESTable 1 Capabilities and Features (continued)Capability/FeatureInfinibandExpansion slotsDescriptionThe Infiniband architecture is supported by the PCIe slots Riser 1 (controlled by CPU 1): One full-height profile, 3/4-length slot with x24 connector and x16lane. Riser 2 (controlled by CPU 2): One half-height profile, half-length slot with x24 connector and x16lane. I/O InterfacesDedicated RAID controller slot (see Figure 5 on page 54) An internal slot is reserved for use by the Cisco 12G SAS RAIDcontroller or the Cisco 12G SAS HBA. Rear panel One 1-Gbps RJ-45 management port (Marvell 88E6176) Two 10GBase-T LOM ports (Intel X550 controller embedded on themotherboard) One RS-232 serial port (RJ45 connector) One DB15 VGA connector Two USB 3.0 port connectors One flexible modular LAN on motherboard (mLOM) slot that canaccommodate various interface cards Internal storage devicesFront panel One KVM console connector (supplies two USB 2.0 connectors, oneVGA DB15 video connector, and one serial port (RS232) RJ45connector)Drives are installed into front-panel drive bays that provide hot-swappableaccess for SAS/SATA drives. The server is orderable with a SFF or LFF drivebackplane. Details for the LFF version are: UCSC-C220-M5L: Up to four 3.5 inch (LFF) SAS/SATA hard drives (HDDs) or SAS/SATAsolid state drives (SSDs). Optionally, up to two SFF NVMe PCIe SSDs (replacing SAS/SATAdrives). These drives must be placed in front drive bays 1 and 2 onlyand are connected from Riser 2. One internal USB 3.0 port on the motherboard that you can use with anoptional 16 GB USB thumb drive for additional storage. A mini-storage module connector on the motherboard supports either: An SD card module with two SD card slots. Mixing different capacitySD cards is not supported. An M.2 module with two SATA M.2 SSD slots. Mixing different capacityM.2 modules is not supported. One socket for a micro-SD card on PCIe Riser 1. The micro-SD cardserves as a dedicated resource for utilities such as HUU. Images can bepulled from a fileshare (NFS/CIFS) and uploaded to the cards for futureuse.Cisco UCS C220 M5 Rack Server (Large Form Factor Disk Drive Model)6

BASE SERVER STANDARD CAPABILITIES and FEATURESTable 1 Capabilities and Features (continued)Capability/FeatureDescriptionIntegrated managementprocessorBaseboard Management Controller (BMC) running Cisco IntegratedManagement Controller (CIMC) firmware.Depending on your CIMC settings, the CIMC can be accessed through the1-GbE dedicated management port, the 1-GbE LOM ports, or a Cisco virtualinterface card (VIC).UCSMStorage controllerCIMC manages certain components within the server, such as the Cisco 12GSAS HBA.Unified Computing System Manager (UCSM) runs in the Fabric Interconnectand automatically discovers and provisions some of the server components. Embedded RAID (software RAID) Supports up to four SATA-only drives Requires a SATA interposer board Cisco 12G SAS RAID controller card with internal SAS connectivity. Supports up to four internal SAS/SATA drives Plugs into a dedicated RAID controller slot Supports RAID 0, 1, 5, 6, 10, 50, 60, and JBOD mode Cisco 12G SAS HBA Supports up to four internal SAS/SATA drivesModular LAN onMotherboard (mLOM)slot Plugs into the dedicated RAID controller slotThe dedicated mLOM slot on the motherboard can flexibly accommodate thefollowing cards: Cisco Virtual Interface Cards Quad Port Intel i350 1GbE RJ45 Network Interface Card (NICNOTE: The four Intel i350 ports are provided on an optional card that plugs into the mLOM slot, and are separate from the two embedded (on the motherboard) LAN ports7Cisco UCS C220 M5 Rack Server (Large Form Factor Disk Drive Model)

CONFIGURING the SERVERCONFIGURING the SERVERFollow these steps to configure the Cisco UCS C220 M5 LFF Rack Server: STEP 1 VERIFY SERVER SKU, page 9 STEP 2 SELECT CPU(s), page 10 STEP 2 SELECT CPU(s), page 10 STEP 3 SELECT MEMORY, page 13 STEP 4 SELECT RAID CONTROLLERS, page 16 STEP 5 SELECT DRIVES, page 20 STEP 6 SELECT PCIe OPTION CARD(s), page 23 STEP 7 ORDER POWER SUPPLY, page 26 STEP 8 SELECT POWER CORD(s), page 27 STEP 9 ORDER TOOL-LESS RAIL KIT AND OPTIONAL REVERSIBLE CABLE MANAGEMENTARM, page 30 STEP 10 SELECT MANAGEMENT CONFIGURATION (OPTIONAL), page 31 STEP 11 SELECT SERVER BOOT MODE (OPTIONAL), page 32 STEP 12 ORDER SECURITY DEVICES (OPTIONAL), page 33 STEP 13 SELECT LOCKING SECURITY BEZEL (OPTIONAL), page 34 STEP 14 ORDER CISCO SD CARD MODULE (OPTIONAL), page 35 STEP 15 ORDER M.2 SATA SSD (OPTIONAL), page 36 STEP 16 ORDER INTERNAL MICRO-SD CARD MODULE (OPTIONAL), page 37 STEP 17 ORDER OPTIONAL USB 3.0 DRIVE, page 38 STEP 18 SELECT OPERATING SYSTEM AND VALUE-ADDED SOFTWARE, page 39 STEP 19 SELECT OPERATING SYSTEM MEDIA KIT, page 45 STEP 20 SELECT SERVICE and SUPPORT LEVEL, page 46 OPTIONAL STEP - ORDER RACK(s), page 52 OPTIONAL STEP - ORDER PDU, page 53Cisco UCS C220 M5 Rack Server (Large Form Factor Disk Drive Model)8

CONFIGURING the SERVERSTEP 1VERIFY SERVER SKUVerify the product ID (PID) of the server as shown in Table 2.Table 2 PID of the C220 M5 LFF Rack Base ServerProduct ID (PID)DescriptionUCSC-C220-M5LUCS C220 M5 LFF, no CPU, memory, HDD, power supply, SD cards, PCIe cards, ortool-less rail kitThe Cisco C220 M5 server: Does not include power supply, CPU, memory, hard disk drives (HDDs), SD cards, rail kit,plug-in PCIe cards.NOTE: Use the steps on the following pages to configure the server withthe components that you want to include.9Cisco UCS C220 M5 Rack Server (Large Form Factor Disk Drive Model)

CONFIGURING the SERVERSTEP 2SELECT CPU(s)The standard CPU features are: Intel Xeon processor scalable family CPUsIntel C620 series chipsetCache size of up to 38.5 MBSelect CPUsThe available CPUs are listed in Table 3.Table 3 Available Intel CPUsProduct ID B)CoresUPI2 Links(GT/s)HighestDDR4 DIMMClockSupport(MHz)3Intel Xeon Processor Scalable Family CPUsUCS-CPU-8180M8180M2.520538.50283 x 10.42666UCS-CPU-6142M6142M2.615022.00163 x 10.42666UCS-CPU-6134M6134M3.213024.7583 x 10.42666UCS-CPU-8176M8176M2.116538.50283 x 10.42666UCS-CPU-8170M8170M2.116535.75263 x 10.42666UCS-CPU-8160M8160M2.115033.00243 x 10.42666UCS-CPU-6140M6140M2.314024.75183 x 10.42666UCS-CPU-818081802.520538.50283 x 10.42666UCS-CPU-817681762.116538.50283 x 10.42666UCS-CPU-817081702.116535.75263 x 10.42666UCS-CPU-816881682.720533.00243 x 10.42666UCS-CPU-816481642.015035.75263 x 10.42666UCS-CPU-816081602.115033.00243 x 10.42666UCS-CPU-815881583.015024.75123 x 10.42666UCS-CPU-815681563.610516.5043 x 10.42666UCS-CPU-815381532.012522.00163 x 10.42666UCS-CPU-615461543.020024.75183 x 10.42666UCS-CPU-615261522.114030.25223 x 10.42666UCS-CPU-615061502.716524.75183 x 10.42666UCS-CPU-614861482.415027.50203 x 10.42666UCS-CPU-614261422.615022.00163 x 10.42666UCS-CPU-614061402.314024.75183 x 10.42666UCS-CPU-613861382.012527.50203 x 10.42666UCS-CPU-613661363.015024.75123 x 10.42666Cisco UCS C220 M5 Rack Server (Large Form Factor Disk Drive Model)10

CONFIGURING the SERVERTable 3 Available Intel CPUsProduct ID B)CoresUPI2 Links(GT/s)HighestDDR4 3 X 10.42666UCS-CPU-613261322.614019.25143 x 10.42666UCS-CPU-613061302.112522.00163 x 10.42666UCS-CPU-612861283.411519.2563 x 10.42666UCS-CPU-612661262.612519.25123 x 10.42666UCS-CPU-512251223.610516.5042 x 10.42666UCS-CPU-512051202.210519.25142 x 10.42400UCS-CPU-511851182.310516.50122 x 10.42400UCS-CPU-511551152.48513.75102 x 10.42400UCS-CPU-411641162.18516.50122 x 9.62400UCS-CPU-411441142.28513.75102 x 9.62400UCS-CPU-411241122.6858.2542 x 9.62400UCS-CPU-411041102.18511.0082 x 9.62400UCS-CPU-410841081.88511.0082 x 9.62400UCS-CPU-310631061.78511.0082 x 9.62133UCS-CPU-310431041.7858.2562 x 9.62133Notes:1. Only CPU PIDs ending in “M” support 1.5 TB/socket of memory, per Intel CPU spec. All other CPUPIDs support 768 GB/socket memory.2. UPI Ultra Path Interconnect. 2-socket servers support only 2 UPI performance, even if the CPUsupports 3 UPI.3. If higher or lower speed DIMMs are selected than what is shown in the table for a given CPU, theDIMMs will be clocked at the lowest common denominator of CPU clock and DIMM clock.11Cisco UCS C220 M5 Rack Server (Large Form Factor Disk Drive Model)

CONFIGURING the SERVERApproved Configurations(1) 1-CPU configurations: Select any one CPU listed in Table 3 on page 10.(2) 2-CPU Configurations: Select two identical CPUs from any one of the rows of Table 3 on page 10.Caveats You can select either one processor or two identical processors. The selection of 1 or 2 CPUs depends on the desired server functionality. See the followingsections:—STEP 3 SELECT MEMORY, page 13 (memory mirroring section)—Table 6 on page 19 (RAID support table)—STEP 5 SELECT DRIVES, page 20—STEP 4 SELECT RAID CONTROLLERS, page 16—STEP 6 SELECT PCIe OPTION CARD(s), page 23Cisco UCS C220 M5 Rack Server (Large Form Factor Disk Drive Model)12

CONFIGURING the SERVERSTEP 3SELECT MEMORYThe standard memory features are: Clock speed: 2666 MHz—Ranks per DIMM: 1, 2, 4, or 8—Operational voltage: 1.2 V—Registered ECC DDR4 DIMMs (RDIMMs), load-reduced DIMMs (LRDIMMs), or throughsilicon via (TSV) DIMMsMemory is organized with six memory channels per CPU, with up to two DIMMs per channel,as shown in Figure 4.Slot 2Slot 2Slot 1C220 M5 LFF Memory OrganizationSlot 1Figure 4—A1A2G2G1Chan GChan AB1C1B2C2Chan BChan HChan CChan JCPU 1D1D2J2J1K2K1L2L1M2M1Chan KE2Chan LChan EF1H1CPU 2Chan DE1H2F2Chan MChan F24 DIMMS3072 GB maximum memory (with 128 GB DIMMs)6 memory channels per CPU,up to 2 DIMMs per channel13Cisco UCS C220 M5 Rack Server (Large Form Factor Disk Drive Model)

CONFIGURING the SERVERSelect DIMMs and Memory MirroringSelect the memory configuration and whether or not you want the memory mirroring option.The available memory DIMMs and mirroring option are listed in Table 4.NOTE: When memory mirroring is enabled, the memory subsystem simultaneouslywrites identical data to two channels. If a memory read from one of the channelsreturns incorrect data due to an uncorrectable memory error, the systemautomatically retrieves the data from the other channel. A transient or soft error inone channel does not affect the mirrored data, and operation continues unless thereis a simultaneous error in exactly the same location on a DIMM and its mirroredDIMM. Memory mirroring reduces the amount of memory available to the operatingsystem by 50% because only one of the two populated channels provides data.Table 4 Available DDR4 DIMMsProduct ID (PID)PID DescriptionVoltageRanks/DIMMUCS-MR-128G8RS-H128 GB DDR4-2666-MHz TSV-RDIMM/PC4-21300/8R/x41.2 V8UCS-MR-X64G4RS-H64 GB DDR4-2666-MHz TSV-RDIMM/PC4-21300/4R/x41.2 V4UCS-ML-X64G4RS-H64 GB DDR4-2666-MHz LRDIMM/PC4-21300/4R/x41.2 V4UCS-MR-X32G2RS-H32 GB DDR4-2666-MHz RDIMM/PC4-21300/2R/x41.2 V2UCS-MR-X16G1RS-H16 GB DDR4-2666-MHz RDIMM/PC4-21300/1R/x41.2 V1UCS-MR-X16G2RS-H16 GB DDR4-2666-MHz RDIMM/PC4-21300/2R/x41.2 V2UCS-MR-X8G1RS-H8 GB DDR4-2666-MHz RDIMM/PC4-21300/1R/x41.2 V1Memory Mirroring OptionN01-MMIRRORMemory mirroring optionApproved Configurations(1) 1-CPU configuration without memory mirroring: Select from 1 to 12 DIMMs.(2) 1-CPU configuration with memory mirroring:Cisco UCS C220 M5 Rack Server (Large Form Factor Disk Drive Model)14

CONFIGURING the SERVER Select 4, 6, 8, or 12 identical DIMMs. The DIMMs will be placed by the factory as shown in thefollowing table.TotalNumberof DIMMsCPU 1 DIMM Placement in Channels (for identical ranked DIMMs)4(A1, B1); (D1, E1)6(A1, B1, C1); (D1, E1, F1)8(A1, A2, B1, B2); (D1, D2, E1, E2)12(A1, A2, B1, B2, C1, C2); (D1, D2, E1, E2, F1, F2) Select the memory mirroring option (N01-MMIRROR) as shown in Table 4 on page 14.(3) 2-CPU configuration without memory mirroring: Select from 1 to 12 DIMMs per CPU.(4) 2-CPU configuration with memory mirroring: Select 8,12 16, or 24 identical DIMMs per CPU. The DIMMs will be placed by the factory asshown in the following table.Numberof DIMMsper CPUCPU 1 DIMM Placement in Channels (for identical ranked DIMMs)CPU 2 DIMM Placement in Channels (for identical ranked DIMMs)CPU 1CPU 28(A1,B1); (D1,E1)(G1, H1); (K1, L1)12(A1, B1, C1); (D1, E1, F1)(G1, H1, J1); (K1, L1, M1)16(A1, A2, B1, B2); (D1, D2, E1, E2)(G1, G2, H1, H2); (K1, K2, L1, L2)24(A1, A2, B1, B2, C1, C2); (D1, D2, E1,E2, F1, F2)(G1, G2, H1, H2, J1, J2); (K1, K2, L1, L2,M1, M2) Select the memory mirroring option (N01-MMIRROR) as shown in Table 4 on page 14.NOTE: System performance is optimized when the DIMM type and quantity are equalfor both CPUs, and when all channels are filled equally across the CPUs in the server.15Cisco UCS C220 M5 Rack Server (Large Form Factor Disk Drive Model)

CONFIGURING the SERVERSTEP 4SELECT RAID CONTROLLERSRAID Controller Options (internal HDD/SSD support)Embedded Software RAIDThe default RAID configuration is embedded software RAID, which supports only SATA HDDs andenterprise value SSDs (RAID 0, 1, 10). A maximum of four SATA drives are supported withembedded software RAID. Embedded RAID requires a SATA interposer board.NOTE: The embedded software RAID is limited to Windows and Linux operatingsystems only. There is no VMware support for embedded software RAID.Cisco 12G SAS RAID controllerYou can choose a Cisco 12G SAS RAID controller, which plugs into a dedicated RAID controller card slot. ThisRAID controller includes a 2 GB cache and supports RAID 0, 1, 5, 6, 10, 50, 60 and JBOD mode.NOTE: The number of RAID groups (virtual drives) supported per RAID controller isas follows: Embedded RAID 8 Cisco 12G SAS RAID controller 64Cisco 12G SAS HBA (internal HDD/SSD/JBOD support)You can choose a SAS HBA for JBOD or pass-through mode support: The Cisco 12G SAS HBA supports up to four drives and plugs into a dedicated RAID controllerslot.RAID Volumes and GroupsWhen creating each RAID volume, follow these guidelines: Use the same capacity for each drive in each RAID volume For embedded software RAID: —Use only SATA HDDs—Embedded software RAID has two ports and each port can control 4 drives.—Each set of 4 SATA HDDs for a port must be in separate RAID volumes.—You cannot mix drives across ports to create a RAID volume.—For more details, see Serial Port Details, page 58.For the Cisco 12G SAS RAID controller upgrade:—Use either all SAS HDDs, or all SAS SSDs, or all SATA SSDs in each RAID volumeCisco UCS C220 M5 Rack Server (Large Form Factor Disk Drive Model)16

CONFIGURING the SERVERSelect Controller OptionsSelect one of the following: Embedded software RAID (this is the default if no other selection is made), or One Cisco 12G SAS RAID controller or Cisco 12G SAS HBA (see Table 5 on page 17), or forthe Cisco 12G SAS RAID controller, select an appropriate optional RAID configuration listed inTable 5 on page 17Table 5 shows the product ID for the C220 M5 server entry-level RAID solution. This RAID option isaccomplished with embedded software that supports a limited number of drives, operating systems, andvirtualized environments. For a more comprehensive enterprise RAID solution, choose the Cisco 12G SASRAID controller listed in Table 5.Table 5 Hardware Controller OptionsProduct ID (PID)PID DescriptionControllers for Internal DrivesNote that if the following Cisco 12G SAS RAID controller or Cisco 12G SAS HBA controller is selected,it is factory-installed in the dedicated internal slot.UCSC-RAID-M5Cisco 12G SAS RAID Controller with 2GB FBWC Supports up to 4 internal SAS HDDs and SAS/SATA SSDs Supports RAID 0, 1, 5, 6, 10, 50, 60 and JBOD Mode. UCSC-SAS-M5For all self-encrypting drives (SED), standalone Management (CIMC/UCSM)is supported for configuring and managing local keys. For now, SED drivesare managed with local key management only. Third-party keymanagement will be supported (KMIP compliant).Cisco 12G SAS HBA Supports up to 4 internal SAS HDDs and SAS/SATA SSDsSupports JBOD mode only (no RAID functionality. Ideal for SDS (SoftwareDefined Storage) applications. It is also ideal for environments demandingthe highest IOPs (for external SSD attach), where a RAID controller can bean I/O bottleneck.No SED drive supportRAID Configuration Options (not available for Cisco 12G SAS HBA or embedded software RAID)R2XX-SRAID0Enable Single Disk Raid 0 SettingR2XX-RAID0Factory preconfigured RAID striping optionEnable RAID 0 Setting. Requires a minimum of one hard drive.R2XX-RAID1Factory preconfigured RAID mirroring optionEnable RAID 1 Setting. Requires exactly two drives with the same size, speed,capacity.R2XX-RAID517Factory preconfigured RAID option Enable RAID 5 Setting. Requires a minimum of three drives of the same size,speed, capacity.Cisco UCS C220 M5 Rack Server (Large Form Factor Disk Drive Model)

CONFIGURING the SERVERTable 5 Hardware Controller Options (continued)Product ID (PID)PID DescriptionR2XX-RAID6Factory preconfigured RAID option Enable RAID 6 Setting. Requires a minimum of four drives of the same size,speed, capacity.R2XX-RAID10Factory preconfigured RAID option Enable RAID 10 Setting. Requires a even number of drives (minimum of fourdrives) of the same size, speed, capacity.NOTE: Although RAID levels 50 and 60 are not orderable from the factory, they aresupported for selected controllers as shown in Table 5.Approved Configurations The embedded software RAID default supports up to 4 internal SATA HDDs with RAID 0, 1, 10support. The Cisco 12G SAS RAID controller upgrade option supports up to four internal drives withRAID 0, 1, 10, 5, 6, 50, 60, and JBOD mode support. The Cisco 12G SAS HBA upgrade option supports up to four internal drives with JBODsupport.See Table 6 for a summary of the supported controller configuration options.Cisco UCS C220 M5 Rack Server (Large Form Factor Disk Drive Model)18

CONFIGURING the SERVERTable 6 Supported Controller Configurations for C220 M5 LFF ServerServerModelC220 M5 LFF4 DrivesC220 M5 LFF4 DrivesCisco 12G SAS RAID Controlleror Cisco 12G SAS HBA (onlyone can be installedMAX##EmbeddedInternal Driveat a time)RAID SupportDrivesCPUsRAIDTypes AllowedSupportedCisco 12G SASCisco 12G SASRAIDHBAController1EnabledNot allowedNot allowed1NotallowedInstalled in adedicated slotInstalled in adedicated slot4 internalSATA only0, 1, 10 (SATAonly)SATAHDDs/EnterpriseValue SSDs4 internal0,1,10,5,6,50,60 JBOD(12G SASRAID), JBOD(SAS HBA)SAS HDDs,SAS/SATA SSDs(NVMe requires2 CPUs)4 internalSATA only0, 1, 10 (SATAonly)SATAHDDs/EnterpriseValue SSDs4 internal0,1,10,5,6,50,60 JBOD(12G SASRAID), JBOD(SAS HBA)SAS HDDs,SAS/SATA SSDs,LFF NVMeOnly one of the above can beinstalled at a timeC220 M5 LFF4 DrivesC220 M5 LFF4 Drives2EnabledNot allowedNot allowed2NotallowedInstalled in adedicated slotInstalled in adedicated slotOnly one of the above can beinstalled at a timeNOTE: There is no RAID support for NVMe. In an embedded RAID configuration, onlyembedded software RAID (0, 1, 10) is supported. AHCI mode is not supported.NOTE: There is no RAID support for NVMe. In an embedded RAID configuration, onlyembedded software RAID (1, 1, 10) is supported. AHCI mode is not supported.19Cisco UCS C220 M5 Rack Server (Large Form Factor Disk Drive Model)

CONFIGURING the SERVERSTEP 5SELECT DRIVESThe standard disk drive features are: 3.5-inch large form factor Hot-pluggable Drives come mounted in sledsSelect DrivesThe available drives are listed in Table 7.Table 7 Available Hot-Pluggable Sled-Mounted DrivesPID DescriptionDriveTypeCapacityUCS-HY18TB10K4KN11.8 TB 12G SAS 10K RPM LFF HDD (4K)SAS1.8 TBUCS-HY12TB10K12N1.2 TB 12G SAS 10K RPM LFF HDDSAS1.2 TBUCS-HD1T7KL12N1TB 12G SAS 7.2K RPM LFF HDDSAS1 TBUCS-HD2T7KL12N2 TB 12G SAS 7.2K RPM LFF HDDSAS2 TBUCS-HD4T7KL12N4 TB 12G SAS 7.2K RPM LFF HDDSAS4 TBUCS-HD6T7KL4KN6 TB 12G SAS 7.2K RPM LFF HDD (4K)SAS6 TBUCS-HD8T7KL4KN8 TB 12G SAS 7.2K RPM LFF HDD (4K)SAS8 TBUCS-HD10T7KL4KN10 TB 12G SAS 7.2K RPM LFF HDD (4K)SAS10 TBUCS-HD12T7KL4KN12 TB 12G SAS 7.2K RPM LFF HDD (4K)SAS12 TBUCS-HD6T7KLEM6 TB 12G SAS 7.2K RPM LFF HDD (512e)SAS6 TBUCS-HD10T7KLEM10 TB 12G SAS 7.2K RPM LFF HDD (512e)SAS10 TBUCS-HD12T7KLEM12 TB 12G SAS