Thermal Shock ChamberTSE 11 ACAT.NO.E01133-T1202

ESPEC offers a compact, but highly performantthermal shock chamber ideal for the requirements oftest standards with small and low-volume specimen.Equipped with superior temperature recovery performancecapable of answering the requirements of severe test specifications,this thermal shock model offers a wide test area in a compact, slim design.1*The paperless recorder and additional overheat protector are optional.

CharacteristicsA high performance compact package to meet severe test requirements.A temperature recovery time ofless than 5 minutes is achievedin 2 zones ( 150 and 65 )without auxiliary coolingBy realizing a temperature recovery timeof less than 5 minutes for the upstreamair in the 2 zones ( 150 and 65 ),we have achieved performance equivalentto that of a large thermal shock chamberwithout having to use auxiliary coolingby means of liquid carbon dioxide, whichwas requi red i n previous compactthermal shock chamber.Complies with MIL-STD-883Hand other test standardsThis compact thermal shock chambersatisf ies the temperature cycle testrequirements of MIL-STD-883H andother test standard (see page 5).High-temperature exposure Smooth specimen transferThe "soft-move mode" is used to reducevibration shock when specimens aremov i ng bet we e n t he hot a nd coldchambers.Uniform temperaturedistribution across specimens Low-temperature exposureExamples of temperature uniformityTest conditionsHigh temperature exposure 150 30 min.Low temperature exposure 65 30 min.SpecimenPlastic molded IC 2kg Temperature uniformity measurement methodThermocouples were embedded in 10 plasticmolded ICs (16 pin DIPs), which were thenplaced on two levels in each of the cornersand in the center of a specimen basket.Sensor temperatureWithin 1.5 (Test area: upstream)High temperature uniformity performanceensures consistent stress on specimens.Within 1.0 2

CharacteristicsColor LCD interactivetouch-screen systemOperation and settings simplified by theuse of a touch-screen LCD display(instr uctions displayed on-screen).At-aglance confirmation of test patterns,test area temperatures, temperaturecycles, upstream / downstream control,and trend graphs display.Large 10.9-liter-capacity test areaControl panelControllerTest area anti-drop mechanismSettingInteractive key input by touch panelDisplayTFT Color LCDTest patternsRAM (selected entry): a maximum of 40 patterns can be enteredROM (built-in): contains 10 test standard patternsAuxiliaryfunctions・ Timer preset・ Test continuity selection・ Overheat/ Overcool protection・ Upstream/ downstream sensor selection・ Stable time control・ Quick exposure control・ Power recovery mode・ Automatic defrost・ Temperature recovery time setting TestFeatures a 10.9-liter test area, twice thatof our previous model. The volume thatcan be processed is greatly increased,and a 210 297mm printed circuit boardcan be tested in the horizontal position.・ Program memory・ Automatic power shut-off・ Programmed time display・ Test suspension・ Test completion mode selection・ Trend graph・ Alarm history display・ Sensor calibration・ RS-485 communicationareaA braking system fitted to the drivemechanism prevents specimens fromfalling into the test area when thechamber stops operation.O t he r prot e ct ion me cha n ism s a reequipped to ensure that the specimendoes not fall.Easy wiring accessA cable port is provided on the rightside to allow easy wiring of specimensfor measurement during high and lowtemperature cycle tests.Comprehensive safety system230mm148mmA dual safety system automaticallystops the test area drive mechanism ifthe door is left open, and automaticallylocks the door when the test area is inmotion.320mmEquipped with casters for mobility3Cable port (50mm, shown with cap installed)

CharacteristicsA whole range of environmentally-friendly features600Rear intake andceiling exhaust1050Minimum footprintTop viewRequired footprint(Installation space: 2.88 m2) Unit: mm2250Reduced power consumptionReduced power consu mption is animportant issue for our customers. Thiscompact ther mal shock chamberemploys number of measures such asthe use of electronic expansion valve toreg ulate the ref r igeration capacit ycontrol. Specifically aimed at energysavings.Material labeling for easy recyclingPlastic molded components are labeledand easily detachable to make recyclinge a s ie r fo r f u t u r e d i s p o s a l of t h eequipment.600Its slim design requires only 2.88m 2installation space (31 ft 2). Ideal fornarrow spaces in labs or factories.3006803001280Paperless recorder (option)Built-in paperless recorders is availableto record temperatures from varioussources, such as test area temperature.Recording is possible on Compact FlashCard or via USB port.Paperless recorder (optional)4

TEST STANDARD (TSE-11-A compliant)Exposure temperatureTest standardA 85 100C 150 150High/ low temp.Temp.Ambient temp.* recovery timeNumber ofcyclesTest startingpointMinimum10 cyclesLow or hightemp.5 cycles if notspecifiedLow temp.6 cyclesHigh temp.5 or 10 cyclesLow temp.0 55 10B 125 150MIL-STD-883H(Method No.1010.8)Exposure timeHigh temp. Ambient temp.* Low temp.̶more than10 min.̶Specimentemp within15 min.at worstcondition3 hours2 hours1 hour0.5 hour3 hoursif not specifiedless than 10 sec.less than 10%of exposuretime0 65 10D 200 150F 175 150 70 85 100 IEC 60068-2-14 125 (JIS C 60068-2-14) 155 175 200 JASO D 001EIAJ ED-2531A 2 2 2 2 2 2 21 85 2 75 3 120 60 65 70 75 80 85 90 95 100 2 2 2 2 2 2 2 2 2Ambienttemp.Ambienttemp.Ambienttemp. 5 10 25 40 55 65 3 3 3 3 3 3 40 0 5 10 15 20 25 30 35 40 45 50 3 3 3 3 3 3 3 3 3 3 3Less than 0.2 kg1 hour 15 min.00.2〜0.8 kg2 hours 15 min.ShortUpstream of0exposure isspecimen0.8〜1.5 kgrecommendable within 5 min.3 hours 15 min.0More than 1.5 kg4 hours 15 min.03 hours2 hours1 hour0.5 hour3 hoursif not specifiedless than 10 sec.less than 10%of exposuretime The above specification tests include only those tests applicable to TSE-11-A. For further information, please contact us.* Ambient temperature at exposure temperature and exposure time represents the temperature and time when moving from hot chamber to cold chamber.5

SPECIFICATIONSTemp. recoveryClodchamberHotTest areachamberTSE-11-A2-zone transition by vertical transfer of specimenPerformance *1ModelSystemHigh temp. exposure range 60 to 200 ( 140 to 392 )Low temp. exposure range 65 to 0 ( 85 to 32 )Temperature fluctuation *2 0.5 ( 0.9 )Pre-heat upper limit 200 ( 392 )Temp. heat-up time *3Ambient temp. to 200 ( 392 ) within 30 min.Pre-cool lower limit 80 ( 112 )Temp. pull-down time *3Ambient temp. to 80 ( 112 ) within 90 min.・ 2 zonesHigh temperature exposure: 150 ( 302 ), 30 min.Low temperature exposure: 65 ( 85 ), 30 min.・ Sensor position: Upstream・ Specimen: Plastic molded ICs 2 kgRecovery conditionsTemp. recovery timewithin 5 min.Test areaShelf brackets on 2 levels of fixed d wire heaterSystemMechanical cascade refrigeration systemCompressorRotary 1.5 kW 2RefrigerantR508A R404ACondenserAir-cooled condenserCoolerPlate fin cooler, cold accumulatorAir circulatorSirocco fanSpecimen power supply control terminal, integrating hour meter without reset,time signal (2), cable port 50 mm, (right side), casters with leveling feer (4), power cableFittingsTest area load resistance8 kgSpecimen basket load capacity2kg per basket (equally distributed load)Inside dimensions (W H D)320 148 230mm (12.6 5.8 9 inch)Test area capacity10.9 LOutside dimensions (W H D) *4680 1625 1050mm (26.8 64 41.3 inch)Weightapproximately 390kgAllowable ambient conditionsPower supply(Voltage fluctuation: rating 10%)Maximum load current0 to 40 ( 32 to 104 )200V AC3φ 3W 50/60Hz220V AC3φ 3W 60Hz26A25AExhaust heat quantity *6*7Noise level380V AC3φ 4W 50Hz400/415V AC3φ 4W 50Hz400V AC *53φ 4W 50Hz17A17A17A17,585kJ/h60dB or less*1 The performance values are under the conditions of a 23 ambient temperature, relative humidity of 65%rh, rated voltage, and no specimen. Heat up timeand pull down time are those of single-unit operation of each chamber.*2 The performance values are based on IEC60068-3-5:2001, JTM K07:2007.*3 Temperature heat-up/pull-down time account for performance of each temperature chamber.*4 Excluding protrusions.*5 Compliance with CE Marking.*6 At ambient temperature 23 .*7 At 1m from front of chamber, 1.2m from floor. (ISO 1996-1:2003 A-weighted sound pressure level) depending on environmentDo not use specimens which are explosive or inflammable, or which contain suchsubstances. To do so could be hazardous, as this may lead to fire or explosion. DANGERDo not place corrosive materials in the chamber. If corrosive substances orhumidifying water is used, the life of the unit may be significantly shortened. Do not place life forms or substances that exceed allowable heat generation. Be sure to read the user’s manual before operation.CAUTION6

SAFETY DEVICES OPTIONSLeakage breaker (200, 220, 380, 400/ 415V AC)Circuit breaker (400V AC)Electrical compartment door switchHot chamber overheat protection switchCold chamber overheat protection switchHot chamber overheat protector (Controller)Cold chamber overheat / overcool protectors (Controller)Test area overheat and overcool protectors (Built-in controller)Test area overheat / overcool protectorsRefrigerator high pressure switchThermal relay for compressorTemperature switch for compressorTemperature switch for air circulatorThermal relay for air circulatorMotor inverterMotor reverse prevention relayHot chamber door switchCold chamber door switchTest area holdDoor lock mechanismsFuseSpecimen power supply control terminalPaperless recorderRecords temperature of each sectionsuch as the temperature inside thechamber.Number of inputs:PL1S: 1 (5 more channels can be turned ON)Data saving cycle: 1 secPL3S: 3 (3 more channels can be turned ON)Data saving cycle: 1 secPL3L: 3 (3 more channels can be turned ON)Data saving cycle: 5 secTemperature range: 100 to 220 External memory:CF memory card port(Includes a 256MB CF card)Languag: ENG, JPN can be changedACCESSORIES Specimen basket (18-8 Cr-Ni stainless steel, 5 mesh metal basket)W320 H35 D230mmLoad capacity: 2kg (equally distributed)Cartridge fuse (5 A)Cable port rubber plugWirefisherUser's manual (CD-R, booklet)Temperature recorder (digital display)21211 setTemperature range: 100 to 220 Effective recording chart width:100mm・RK-61: 1pen・RK-63: 3 pens・RK-64: 6 dotsRecorder wiringPreparation of a power cable, temperature sensor, and conductor groundingwire for additional installation in thefuture.7

OPTIONSTerminal for recorderTotal cycle counterSpecimen basketTo output temperature values fromthe test area, hot chamber, coldchamber.Indicates cycle counts.Display range: 1 to 99999999(with reset function)Equivalent to standard accessory.・Material: stainless steel (5 mesh)Specimenpower supplycontrolterminalTime signalExternal alarmterminal (option)Additional overheat protectorAdditional preventive measures canbe taken for excessive temperaturerise in the chamber, in addition tothe standard equipped overheatprotectors.Used to bolt the chamber to the floor.Power cableThermocoupleAttached to specimens to measurespecimen temperature.・2m・4m・6m* T JIS C 1602 with ball attachedAnchoring fixturesExternal alarm terminalIf the safety device of the chamberis activated, the exter nal alar mterminal will notify it to a remotepoint.Used to con nect to the pr imar ypower source.・5m・10mColor specificationAuxiliary cooling injector (LCO2)Emergency stop pushbuttonUsed to reduce the temperat urerecovery time of low temperatureexposu re by injecting liquef iedcarbon dioxide at the beginning ofexposure.Stops the chamber immediately.Chamber can be painted to anydesired color. (a color sample isrequired)Interface・Computer interface GPIBRS 232C・Serial interface*Select one, instead of standard RS 485.Auxiliary cooling injector (LN2)Used to reduce the temperat urerecovery time of low temperatureexposu re by injecting liquef iedn it rogen at t he beg i n n i ng ofexposure.Cable port rubber plugPrevents air leakage from the cableport.Communication cable・RS 485・GPIB・RS 232C5m/ 10m/ 30m2m/ 4m1.5m/ 3m/ 6m Some photographs listed in this catalog contain Japanese display.8

http://www.espec.co.jp/englishHead Office3-5-6, Tenjinbashi, Kita-ku, Osaka 530-8550, JapanTel : 81-6-6358-4741Fax : 81-6-6358-5500ESPEC NORTH AMERICA, INC.Tel : 1-616-896-6100 Fax : 1-616-896-6150ESPEC EUROPE GmbHTel : 49-89-1893-9630 Fax : 49-89-1893-96379ESPEC (CHINA) LIMITEDTel : 852-2620-0830Fax : 852-2620-0788ESPEC ENVIRONMENTAL EQUIPMENT (SHANGHAI) CO., LTD.Head OfficeTel : 86-21-51036677 Fax : 86-21-63372237BEIJING BranchTel : 86-10-64627025 Fax : 86-10-64627036TIANJIN BranchTel : 86-22-26210366 Fax : 86-22-26282186GUANGZHOU BranchTel : 86-20-83317826 Fax : 86-20-83317825SHENZHEN BranchTel : 86-755-83674422 Fax : 86-755-83674228SUZHOU BranchTel : 86-512-68028890 Fax : 86-512-68028860ESPEC TEST TECHNOLOGY (SHANGHAI) CO., LTD.Tel : 86-21-68798008 Fax : 86-21-68798088ESPEC SOUTH EAST ASIA SDN.BHD.Tel : 60-3-8945-1377 Fax : 60-3-8945-1287Quality Management System Assessedand RegisteredESPEC CORP. has been assessed by andregistered in the Quality Management Systembased on the International Standard ISO9001:2008 (JIS Q 9001:2008) through theJapanese Standards Association (JSA).*Registration : ESPEC CORP.(Overseas subsidiaries not included)TW2E24C03 (The contents of this catalog is as of February, 2012.)Environmental Management System Assessedand RegisteredESPEC CORP. Specifications are subject to change without notice due to design improvements. Corporate names and trade names mentioned in this catalog are trademarks or registered trademarks.

ESPEC offers a compact, but highly performant thermal shock chamber ideal for the requirements of test standards with small and low-volume specimen. Equipped with superior temperature recovery performance capable of answering the requirements of severe test specifications, this thermal shock model offers a wide test area in a compact, slim design.