MultiVolume Pycnometer 1305 And Accessories - Micromeritics

Transcription

MultiVolume Pycnometer 1305 and AccessoriesMultiVolume Pycnometer 1305 and AccessoriesFor rapid volume measurement of dry powders and solids. Usessample sizes from 150 to 0.5 cm3 with 0.1 to 0.2% volumeaccuracy over the entire measurement range.130-50000-00VACUUM GREASEUniversal electrical inputFILTER GASKET004-27039-00008-16045-00Cajon (Swagelok) filter gasketfor plumbing assemblySilicone, high vacuum, 150 gCALIBRATION STANDARDFUSE003-51135-00003-51141-01Slow-Blow, 3 AG, 0.5 A, for100/120 V mainsSlow-Blow, 5 x 20 mm, for200/240 V mains135-25813-00130-25658-00135-25815-002.43 cm316.76 cm325.49 cm3135-25805-00135-25804-00135-25812-005-cm3 sample capacity35-cm3 sample capacity150-cm3 sample capacity004-25103-00Front, Teflon, for 1/4-in.(0.64-cm) OD tubingFront, Brass, for 1/8-in.(0.32-cm) OD tubingRear, Nylon, for 1/4-in.(0.64-cm) OD tubingRear, Brass, for 1/8-in.(0.32-cm) OD tubingSAMPLE CUPREDUCER004-25549-001/8-in. (0.32-cm) compressionfitting to 1/4-in. (0.64-cm) tubeFERRULEVOLUME DISPLACEMENT INSERTFront135-25803-00135-25802-00For a 5-cm3 sample cupFor a 35-cm3 sample cupRear004-25198-00004-25104-00004-25199-00May 20071

MultiVolume Pycnometer 1305 and a-N, Size 032, forsample chamber capOperator’sGAS tended Operation Supplies; includes fuses,O-rings, filters, and sample cups.CGA 580 fitting, 30 psigExpansion Kit; two outlets, includes fittings andinstructions.GAS INLET ASSEMBLY230-02001-00Copper, 1/8-in. with 1/8-in. Swagelok nut andferrules (6-foot length)2May 2007

AccuPyc 1340 Pycnometer and Accessories; AccuPyc 1330 AccessoriesAccuPyc 1340 Pycnometer and Accessories;AccuPyc 1330 AccessoriesThe AccuPyc accurately and precisely measures the density ofsolids having volumes from 0.1 to 350 00134-00020-00134-00030-00Analysis Module134-00031-00Control 1-00134-00042-00134-00043-0010-cm3 sample capacity control module1-cm3 sample capacity control module100-cm3 sample capacity control module10-cm3 sample capacity control module,with temperature control capability100-cm3 sample capacity control module,with temperature control capability10-cm3 sample capacity analysis module,with glove box module1-cm3 sample capacity analysis module,with glove box module100-cm3 sample capacity analysis module,with glove box module350-cm3 sample capacity analysis module,with glove box module10-cm3 sample capacity analysis module1-cm3 sample capacity analysis module100-cm3 sample capacity analysis module350-cm3 sample capacity analysis moduleSAMPLE CUP INSERTHANDLING TOOLAllows measurement of smaller samples withthe 1-cm3 AccuPyc133-25855-01133-09810-00For handling 1-cm3 sample cupsRetaining Pliers133-09601-00 For handling 0.1-cm3 samplecup insertSAMPLE 21-cm3 sample capacity10-cm3 sample capacity100-cm3 sample capacity350-cm3 sample capacityFiltered Cup AssemblyUsed to constrain powdered 00-cm3Filter paper for 100-cm3 cup,package of 100GREASING DISK133-25825-00KEYPAD 701-04FrenchGermanSpanishItalianVACUUM GREASEUsed to grease the O-ring inthe chamber cap008-16045-00May 20070.1-cm3 sample capacitySilicone, high vacuum, 150 g3

AccuPyc 1340 Pycnometer and Accessories; AccuPyc 1330 AccessoriesGAS REGULATORCALIBRATION 903-00004-62230-58004-33601-00004-33602-00CGA 580 fitting, 30 psigExpansion Kit; two outlets, includes fittings andinstructions.Pressure Relief Kit; prevents excessive gaspressure in the event of regulator failure. Not tobe used with noxious gases.SOFTWARE AND MANUALAccuPyc II 1340Stand Alone134-33003-00GAS INLET ASSEMBLY134-42801-00134-42803-00Copper, 1/8-in. with 1/8-in. Swagelok nut andferrules (6-foot length)290-25846-00230-02001-00For 1-cm3 AccuPycFor 10-cm3 AccuPycFor 100-cm3 AccuPycFor 350-cm3 AccuPycWindows 134-33005-00For AccuPyc 1340;uses Valco ferrulesFor AccuPyc 1330134-42802-00134-42804-00O-RINGFoamPyc Option, foranalysis of rigid foammaterials; includes softwareand operator’s manualOperator’s manualOperator’s manual,FoamPyc OptionFoamPyc Option, foranalysis of rigid foammaterials; includes softwareand operator’s manualOperator’s manualOperator’s manual,FoamPyc OptionAccuPyc 00004-25469-00Chamber cap, 1-cm3sample moduleChamber cap, 10-cm3sample moduleChamber cap, 100-cm3sample moduleChamber cap, 350-cm3sample moduleFor inlet amPyc Option, foranalysis of rigid foammaterials; includes softwareand operator’s manualOperator’s manual, 10- and100-cm3Operator’s manual, 1-cm3Operator’s manual,temperature-controlled unitKIT008-32131-00Tube Fitting004-25549-00004-25681-014133-33006-004 ft. flexible; for connectinga circulating bath unit to theAccuPyc 1330TC1/8-in. (0.32-cm)compression fitting to 1/4-in.(0.64-cm) tube1/4 in. (0.64), set of 2; forbath circulator connectorson 00Multigas manifold optionFoamPyc Sample Preparation Kit133-33601-00Extended Operation Supplies for AccuPyc1330; includes O-rings, fuse, frit, and greaseMultiVolume Kit; allows analysis of smaller samples withoutsacrificing accuracy or reproducibility.AccuPyc 1340133-33604-00133-33605-00134-33006-00100-cm3 , contains 10 cm3 & 35 cm3 inserts10-cm3, contains 1 cm3 & 3.5 cm3 inserts1-cm3 , contains 0.1 cm3 insertAccuPyc 1330133-33002-00133-33003-00100-cm310-cm3May 2007

GeoPyc 1360 PycnometerGeoPyc 1360 PycnometerDetermines envelope or T.A.P. densities and/or volumes using aunique displacement method. When absolute density is provided(AccuPyc 1340), the GeoPyc also calculates pore volume andpercent porosity. Universal electrical 6-00SAMPLE CHAMBER ASSEMBLYGeoPyc 1360 Envelope Density AnalyzerGeoPyc 1360 T.A.P.TM Density AnalyzerT.A.P. Density UpgradeEnvelope Density UpgradePLUNGER -07136-25804-07136-25805-07For 12.7-mm ID chamberFor 19.1-mm ID chamberFor 25.4-mm ID chamberFor 38.1-mm ID chamberFor 50.8-mm ID chamberIncludes plunger, cup seal, and quad ring. One sample chamber ofchoice included with purchase of -25804-00136-25805-0012.7-mm ID19.1-mm ID25.4-mm ID38.1-mm ID50.8-mm IDSample 04-10136-25805-1012.7-mm ID19.1-mm ID25.4-mm ID38.1-mm ID50.8-mm IDPiston Rod136-25801-03136-25804-03Small, for 12.7-, 19.1-, and25.4-mm chambersLarge, for 38.1- and 50.8-mmchambersPiston Coupling Extender136-25852-01 For T.A.P. densitymeasurements using the 38.1and 50.8-mm ID chambersPlunger AssemblyConsists of piston and piston 11136-25805-11May 2007For 12.7-mm ID chamberFor 19.1-mm ID chamberFor 25.4-mm ID chamberFor 38.1-mm ID chamberFor 50.8-mm ID chamberDRYFLO 004-16831-003 Liters5

GeoPyc 1360 PycnometerKEYPAD TEMPLATESIEVE004-27059-00004-27065-00No. 35, 500 mmPan; used to catch 4-00136-42005-00FUNNEL004-32177-00Plastic, for adding DryFlo tothe sample chamberEnglishSpanishFrenchGermanItalianSOFTWARE AND MANUALS136-42801-00136-42805-00Operator’s, EnvelopeDensityOperator’s, T.A.P. DensityBRUSH004-54613-003/8-in. wide x 3/4-in. long136-25815-00Black, for samplecompartmentMAT6May 2007

ASAP 2020 Physisorption and Accessories; ASAP 2010 AccessoriesASAP 2020 Physisorption and Accessories;ASAP 2010 AccessoriesMeasures surface area and pore size by physisorption. The oneport analysis manifold/vacuum system and two-port degasmanifold/vacuum system are independent and operateconcurrently. Powerful Windows-based operating program.Includes DFT Plus 0123-00202-00117-00202-00127-00DEWAR AND ACCESSORIESREFERENCE 843-00004-16844-00004-16826-00004-16833-00Nitrogen System, 110 VNitrogen System, 220 VHiVac SystemHiVac System, KalrezMicropore SystemMicropore System, KalrezAlumina, 0.49 m2/g (Krypton),10 gGlass, 5.8 m2/g, 10 gSilica-alumina pellets, surfacearea 198 m2/g, 10 gMicropore, 13X, 10 g,ASAP 2020Micropore, Y-zeolite, 2.5 g,ASAP 2020Micropore, 10 g, ASAP 2010Carbon Black, 24.1 m2/g, 10 gASAP 2020202-25850-00202-25849-00ASAP 00LN2 TRANSFER SYSTEM3 Liter, analysis3 Liter, cold trap1.9 Liter, standard1.9 Liter with hanging clip, forcold traps1 Liter, wide mouth, formonolith sample tubeDewar Kit, extended life;includes 1 each 2.5 Literanalysis Dewar and cold trapDewar, and required hardwareDewar CoverFor easy filling of sample Dewars. Includes 47-LDewar, mobile stand, and pump with 100-cmdischarge line. Universal voltage input.021-00000-00Model 021AnalysisCold TrapASAP 00Cold trap, steelCold trap, glassFor 1.9-Liter DewarFor 1-Liter DewarDewar Depth Gauge240-25901-00 For checking liquid nitrogenlevelFILTER DISK004-27041-00May 2007ASAP 2020202-31707-00202-31708-00For port fittings, 20-micron,1/4-in. diameter x 1/16-in.thick7

ASAP 2020 Physisorption and Accessories; ASAP 2010 AccessoriesSAMPLE TUBE AND r Rod240-61014-00240-61015-00240-61016-0010-cm3 bulb, 1/4-in.(0.64-cm) OD stem10-cm3 bulb, 3/8-in.(0.96-cm) OD stem10-cm3 bulb, 1/2-in.(1.27-cm) OD stemMonolith, 1/4-in. (0.64-cm)OD stem, with springs,1/2-in. (1.27-cm) ID x 1-in.(2.5-cm) capacityMonolith, 1/2-in. (1.27-cm)OD stem, with springs, 1-in.(2.5-cm) ID x 1-in. (2.5-cm)capacityStraight-wall, 1/2-in. OD(1.27-cm) stem, 10-1/2 in.(26.67 cm) longGlass, 1/2-in. (1.27-cm) ODstem, 11 in. long, for coldtrapFor 1/4-in. (0.64-cm) ODsample tube stemFor 3/8-in. (0.96-cm) ODsample tube stemFor 1/2-in. (1.27-cm) ODsample tube stemRubber Stopper240-32000-00 For 1/2-in (1.27-cm) sampletube stems004-32004-00 For 1/4-in. (0.64-cm) &3/8-in (0.96 cm) sampletube stemsFunnel240-25853-00TransealAllows transferal of the sample while stillunder vacuum from the preparation station tothe analysis station. Fits only 1/2-in (1.27-cm)sample tubes.201-33026-00300-25862-00ISOTHERMAL JACKETASAP 2020202-25901-00202-25902-00202-25903-00For 1/4-in. (0.64-cm) OD sample tube stemFor 3/8-in. (0.96-cm) OD sample tube stemFor 1/2-in. (1.27-cm) OD sample tube stemASAP 2010240-32803-03240-32803-02240-25867-00For 1/4-in. (0.64-cm) OD sample tube stemFor 3/8-in. (0.96-cm) OD sample tube stemFor 1/2-in. (1.27-cm) OD sample tube stemHEATING MANTLE WITH THERMOCOUPLEFor filling sample tubesFor bulb sample tubeFor straight-wall sampletubeASAP 2020003-26043-00230-25808-00ASAP 00Brush004-54609-00Starter kit; includes threeTranseals, hardware, andinstructionsTranseal assemblyClipWeighing SupportFor supporting sample tubes while weighing240-32805-00280-32800-00SAMPLE TUBE AND ACCESSORIES (continued)450 ºC, 24 VDCHeating Mantle Clip450 ºC, 24 VDC (CE units)350 ºC, Glass, 115 VAC, with K thermocouple450 ºC, Quartz, 115 VAC, with Kthermocouple350 ºC, Glass, 115 VAC, with Kthermocouple, for monolith sample tubeFor cleaning sample tubesSample Tube Rack240-14855-00 For holding sample tubesSEAL FRIT260-25890-00004-54130-00For 1/2-in sample tubeTool for seal frit; also usedto remove and installopeners in the sample portsTool8May 2007

ASAP 2020 Physisorption and Accessories; ASAP 2010 AccessoriesGAS 01-00004-33601-01004-33602-00CGA 580 fitting, 30 psig (Ar, He, Kr, N2)CGA 350 fitting (CO, H2), 30 psigCGA 540 fitting (O2), 30 psigCGA 320 (CO2), 30 psigExpansion Kit; two outlets, includes fittings andinstructions.Expansion Kit; three outlets, includes fittingsand instructions.Pressure Relief Kit; prevents excessive gaspressure in the event of regulator failure. Not tobe used with noxious gases.GAS INLET 471-00004-25030-00Kalrez 004-25674-00004-25465-00004-25474-00Copper, 1/8-in. with 1/8-in. Swagelok nut andferrules (6-foot length)290-25846-00230-02001-00For ASAP 2020For ASAP 2010CALIBRATION BALL135-25815-0025.487 cm3, ASAP 2010;includes traceablecertificate for ISO 004-25104-00Sample Tube240-25803-00240-25802-00260-25843-00Front, Teflon, for 1/4-in.(0.64-cm) OD tubingRear Ferrule, Nylon, for 1/4in. (0.64-cm) OD tubingFor 1/4-in. (0.64-cm) ODsample tube stemFor 3/8-in. (0.96-cm) ODsample tube stemFor 1/2-in. (1.27-cm) ODsample tube stemSATURATION PRESSURE TUBEMay 2007For sample tube, ASAP2020For sample tube, ASAP2010For cold trap, ASAP 2020For cold trap, ASAP 2010Plug, for sample portVALVE 25936-00200-25840-00Size 006, for Po tubeSize 010, for analysismanifold internal fittingsSize 013, for sealing 1/2-in.(1.27-cm) OD sample tubestemsSize 015, for sealing 1000mmHg transducer; ASAP2010CONNECTOR NUT, KNURLEDFERRULEFront004-25675-00Size 010, for sealing 1/4-in.(0.64-cm) OD sample tubestem and for degasmanifold fittingsSize 012, for sealing 3/8-in.(0.96-cm) OD sample tubestemSize 013, for sealing 1/2-in.(1.27-cm) OD sample tubestemSize 006, for Po tubeSize 217, for oil vapor trapSize 018, for degasmanifold; ASAP 2010Size 030, for calibrationchamber cap; ASAP 2010Buna-N sealKalrez sealSpanner, for servicingdegas valvesKel-F; for analysis manifoldvalvesFor Buna-N seal plungerFor Kalrez seal plungerIncludes isothermal jacket9

ASAP 2020 Physisorption and Accessories; ASAP 2010 AccessoriesRUBBER MAT, BLACKVACUUM PUMP AND ACCESSORIES (continued)Dry System202-25821-00200-25882-02200-25882-04Front shelf, ASAP 2020Elevator area, ASAP 2010Degas area, CE units, ASAP2010VAPOR OPTIONSIncludes vacuum hose, fittings, and manual.ASAP 2020202-33050-00062-00100-00Allows water vaporadsorption studies; includesreservoir containing prepurified water andinstallation instructions.Oil-less vacuum pumpSOFTWARE AND MANUALS202-33001-00202-33051-00202-33011-00Vapor supply option forvapor studies202-33021-00202-33024-00ASAP 2010201-33621-00202-33025-00Vapor supply option forASAP 2010202-42801-00201-42821-00Current version softwareand operator’s manual,ASAP 2020CFR Part 11 Confirmsoftware and operator’smanualRate of Adsorption (ROA)Program; includes software,and operator’s manualDataMaster Program;includes software, andoperator’s manualIsotherm Cycling option;includes operatinginstructionsOperator’s manual, ASAP2020Operator’s manual, ASAP2010, CE unitsVACUUM PUMP AND ACCESSORIESKITOil Vapor TrapAlumina ludes vacuum hose, fittings, oil, and -0110115 V, pump for 2020230 V, pump for 2020Filter; for vacuum pump exhaustOil Vapor Trap Kit; Includes two oil vapor traps,manual, and alumina (for vacuum pumps)Activated alumina pellets, 500 gramsFunnel, for filling vacuum pump with oilOil, 1 Liter004-62109-01202-33006-00200-33006-00Extended Operation Supplies, Nitrogensystem, ASAP 2020Standard degas option, 110 V; enablesautomatic degassingSame as 202-33601-11, 220 VDry HiVac degas option; recommended whenusing Mass specHiVac option, adds 10-mmHg transducer andhigh vacuum pumpMicropore option, adds 1-mmHg transducerChemi option, upgrades HiVac system tochemisorption systemHydrocarbon Manifold Upgrade Kit, ASAP2010Service Kit for dry vacuum pump; includesreplacement diaphragm and sealsChiller Dewar option, ASAP 2020; used whena chiller is attached to the ASAP analyzer formicropore or subambient temperaturesChiller Dewar option, ASAP 2010May 2007

ASAP 2020 Chemisorption and Accessories; ASAP 2010 AccessoriesASAP 2020 Chemisorption and Accessories;ASAP 2010 AccessoriesMeasures metal dispersion and metal surface area bychemisorption. The one-port analysis manifold/vacuum system andtwo-port degas manifold/vacuum system are independent andoperate concurrently. Powerful Windows-based operating program.Universal electrical input.202-00108-00202-00118-00202-00128-00HEATING MANTLE WITH THERMOCOUPLEREFERENCE MATERIAL004-16825-00Chemi SystemChemi-Micropore System, 1-mmHgtransducerChemi-Micropore System, KalrezPt-alumina Pellets, dispersion30.5%, 5 gramsClipLN2 TRANSFER SYSTEMFor easy filling of sample Dewars. Includes 47-LDewar, mobile stand, and pump with 100-cmdischarge line. Universal voltage input.021-00000-00Model 021ASAP 2020C003-26043-00230-25808-00ASAP -00450 ºC, 24 VDCHeating Mantle Clip450 ºC, 24 VDC (CE units)350 ºC, Glass, 115 VAC, with K thermocouple450 ºC, Quartz, 115 VAC, with Kthermocouple350 ºC, Glass, 115 VAC, with Kthermocouple, for monolith sample 74-00May 2007Size 010, sample port filterdiskSize 009, sample exhaustSize 013, sample inlet202-25821-00200-25882-02200-25882-04Front shelf, ASAP 2020Elevator area, ASAP 2010Degas area, CE units,ASAP 201011

ASAP 2020 Chemisorption and Accessories; ASAP 2010 AccessoriesSAMPLE TUBE AND ACCESSORIES004-61701-00Quartz, for use withtemperatures up to 1100 ºC004-61701-02Filler rod for quartz 00Sample or sample tube exhaust,20-micron, 3/16-in. diameterFor port fittings, 20-micronPlunger250-25627-00004-25459-00Stopper, rubber for sampletube inletCap, plastic; for sampletube exhaustWrench004-25157-00Gasket250-25608-00Quartz Wool004-32164-01For Buna-N seal plungerFor Kalrez seal plunger4- x 6-in. bag, for containingsamples in sample tubes25.487 cm3, ASAP 2010;includes traceablecertificate for ISO 9000requirementsCONNECTOR NUT, KNURLED12Kel-F; for analysis manifoldvalvesFor cleaning sample 0200-25979-00201-25822-00Spanner, for servicingdegas valves in ASAP 2010GAS REGULATORCALIBRATION BALL135-25815-00Buna-N sealKalrez sealFor filling sample 00For sample tube exhaust,1/4 in. stainless steelFor 1/2-in. (1.27-cm) ODsample tube stemVALVE ACCESSORIESWeighing Support280-32800-00 For supporting sampletubes while weighingFunnel240-25853-00Front, Teflon, for 1/4-in.(0.64-cm) OD tubingRear Ferrule, Nylon, for1/4-in. (0.64-cm) OD tubingCGA 580 fitting, 30 psig (Ar, He, Kr, N2)CGA 350 fitting (CO, H2), 30 psigCGA 540 fitting (O2), 30 psigCGA 320 (CO2), 30 psigExpansion Kit; two outlets, includes fittings andinstructions.Expansion Kit; three outlets, includes fittingsand instructions.Pressure Relief Kit; prevents excessive gaspressure in the event of regulator failure. Not tobe used with noxious gases.For sample tube to manifoldFor cold trapFor sample tube exhaustMay 2007

ASAP 2020 Chemisorption and Accessories; ASAP 2010 AccessoriesGAS INLET RE AND MANUALSCopper, 1/8 in., for Chemicontroller, ASAP 2020/2010Stainless Steel, 1/8 in., forChemi controller inlets,ASAP 2020/2010Copper, 1/8 in., with 1/8-in.Swagelok nut and ferrulesinstalled, ASAP 2010202-33013-00202-42808-00201-42828-00Current version softwareand operator’s manual,ASAP 2020 ChemiOperator’s manual, ASAP2020 ChemiOperator’s manual, ASAP2010 Chemi, CE unitsKITVACUUM PUMP AND ACCESSORIESOil Vapor TrapOperating Supplies Kit; includes sample tube, O-rings, stoppers,ferrule, frit, quartz wool, and thermocouple clip202-33608-00201-33608-00ASAP 2020 ChemiASAP 2010 ChemiAlumina PelletsFilterIncludes vacuum hose, fittings, oil, and manual.062-00001-11115 V, pump for 2020062-00001-23230 V, pump for 2020004-27040-00Filter; for vacuum pump exhaust200-33014-00Oil Vapor Trap Kit; Includes two oil vapor traps,manual, and alumina (for vacuum pumps)004-16830-00Activated alumina pellets, 500 grams200-25879-00Funnel, for filling vacuum pump with oil004-16003-01Oil, 1 LiterDry SystemIncludes vacuum hose, fittings, and manual.062-00100-00May 2007Oil-less vacuum pump13

FlowSorb III and Accessories; FlowSorb II AccessoriesFlowSorb III and Accessories;FlowSorb II AccessoriesFlowSorb III, a dynamic-flow physical adsorption instrument forsingle- and multipoint specific surface area analysis.FlowSorb III 2310, with automated elevatorFlowSorb III 2305, manually operated231-00002-00DeSorb III; a three-station outgassing devicewhich is useful where increased samplethroughput is needed for the FlowSorb.Universal electrical input. Unavailable incountries requiring CE certification.FERRULELN2 TRANSFER SYSTEMFor easy filling of sample Dewars. Includes 47-LDewar, mobile stand, and pump with 100-cmdischarge line. Universal voltage 3-00FrontRear004-25104-00Front, Teflon, for 1/4-in.(0.64-cm) OD tubingRear Ferrule, Nylon, for 1/4in. (0.64-cm) OD tubingModel 021HEATING MANTLE WITH THERMOCOUPLEDEWAR AND ACCESSORIES004-61004-00Clip350 mL, with safety sleeveand insulating coverFlowSorb III231-26001-00230-25808-00Dewar Cover230-31801-00230-31801-01Insulating, for standard DewarInsulating, split, for cold trapDewarFlowSorb II230-26001-00230-26002-00270-26600-0014Glass Fiber, 24 V (400 ºC)Heating Mantle ClipGlass Fiber, 115 V, for standard sample tubes(350 ºC)Glass Fiber, 115 V, for monolith sample tubes(350 ºC)Quartz Fiber, 115 V, for standard sampletubes (400 ºC)May 2007

FlowSorb III and Accessories; FlowSorb II AccessoriesSAMPLE TUBE AND drical bottom, 1-cm3capacityCylindrical bottom, 1-cm3capacity, package of 6Cylindrical bottom, 1-cm3capacity, package of 12Capillary stem, 1-cm3capacity4.7-cm3 capacityMonolith, up to 2-cmdiameter x 3-cm long solidsample capacityMicro U-tube, 0.1-cm3capacityGAS REGULATOR004-62230-58CGA 580 fitting, 30 psig (Ar, He, Kr, N2)GAS SAMPLING ASSEMBLY290-25842-00Rubber Stopper004-32004-00 For sample tubeFor calibration injectionsWeighing SupportFor supporting sample tubes230-32802-00230-32803-00Funnel240-25853-00For standard sample tubeFor monolithic sample tubeSOFTWARE AND 02-00Nylon, for filling sampletubesO-RINGOperator’s, FlowSorb IIIOperator’s, FlowSorb IIOperator’s, DeSorb 2300AService, FlowSorb IIKITBuna-N004-25034-00004-25466-00Size 008, for sealing sampletube holder stemsSize 010, for sealing sampletube holder stems and coldtrap stems231-33603-00Extended Operation Supplies for theFlowSorb. Includes septum, O-rings, ferrules,syringes with needles, sample tubes, fuses,stoppers, funnel, sample holder, Dewar, andcold trap cover.CALIBRATION on, 1 mLPrecision, 0.1 mL (Kr)Precision, 10 mLSeptum004-32602-00For injection portReplacement Injection Needle004-61604-01 For 10-mL syringe, packageof 3004-61602-01 For 0.1- and 1-mL syringes,package of 3May 200715

Gemini V and AccessoriesGemini V and AccessoriesDetermines single- and multipoint BET and Langmuir surfaceareas, total pore volume, and micropore analysis by the t-method.Universal electrical 0001-00238-00000-00238-00000-00CFRGemini V 2365; with keypadGemini V 2365; with Windows softwareGemini V 2365; with CFR Part 11 ConfirmsoftwareGemini V 2380, also provides BJH porevolume distributions; with keypadGemini V 2380, also provides BJH porevolume distribution; with Windows softwareGemini V 2380, also provides BJH porevolume distribution; with CFR Part 11 ConfirmsoftwareKeypad not used withWindows versionDEWAR AND ACCESSORIESLN2 TRANSFER SYSTEMFor easy filling of sample Dewars. Includes 47-LDewar, mobile stand, and pump with 100-cmdischarge line. Universal voltage input.021-00000-00Right sideLeft sideGlass, 5.8 m2/g, 10 gCarbon Black, 24.1 m2/g,10 g004-62230-58004-33601-00004-33602-00For displacing volume in the balance tubeequivalent to the volume of sample in thesample tube when analyzing high volume, lowsurface area samples.16Dewar Cover236-31802-01236-31802-02GAS REGULATORGLASS BEADS004-61065-00600 mLModel 021REFERENCE MATERIAL004-16818-00004-16833-00004-61064-00CGA 580 fitting, 30 psig (Ar, He, Kr, N2)Expansion Kit; two outlets, includes fittings andinstructions.Pressure Relief Kit; prevents excessive gaspressure in the event of regulator failure. Not tobe used with noxious gases.3 mm, 90 gramsMay 2007

Gemini V and AccessoriesRS-232 CABLESAMPLE TUBE AND ACCESSORIES (continued)003-60155-00003-20616-01Weighing Support280-32800-00 For supporting sampletubes while weighing25- to 9-pin adaptor cableShielded, 10 ft., Female/FemaleFunnelFor filling sample tubesPORT 0040 micron, for sample tubeport2 micron, for balance tubeportNylonAluminumSample Tube Rack240-14855-00 For holding sample tubesO-RINGBuna-N004-25022-00004-25466-00Size 012, for sealing 3/8-in.(9.6-mm) OD sample tubestemSize 010, for filter diskBrush004-54611-00004-54612-00SAMPLE TUBE AND ler 0236-61709-00236-33004-003/4-in. (19.1-mm) OD bulb x6.1-in. (155-mm) long, 9cm3 sample capacity3/8-in. (9.6-mm) OD x 6.1in. (155-mm) long, 2 cm3sample capacity5/8-in. (16-mm) OD x 0.53in. (13.5-mm) ID x 6-in. (152mm) longFor balance and sampletubes, 7 mm x 146.1 mmFor sample tube, 7 mm x101.6 mmHanging filler rod, 7 mm ODHanging filler rod, 13 mmODHanging filler rod, 25.4 mmODFiller Rod Accessory Kit;includes two connectorswith hooks attached and two7-mm filler rods.Rubber Stopper004-32004-00 For 1/4-in. (0.64-cm) &3/8-in. (0.96-cm) sampletube stemsMay 2007For cleaning standardsample tubeFor cleaning bulb sampletubeFUSE003-51113-00Slow-Blow, 3 AG,1.5 A, for allpower settingsKEYPAD 701-04FrenchGermanSpanishItalianISOTHERMAL INSERTS FOR SAMPLE PREP UNITSProvides an isothermal shield around thesample tube for maintaining a uniformtemperature065-25811-00065-25812-00For bulb sample tubeFor straight-wall sample tube17

Gemini V and AccessoriesVACCUM PUMP AND ACCESSORIESKIT236-33601-00Oil Vapor TrapAlumina -33014-00004-16830-00200-25879-00004-16003-01115 V; includes vacuum hose fittings, exhaustfilter, oil, and manual230 V; includes vacuum hose fittings, exhaustfilter, oil, and manualFilter; for vacuum pump exhaustOil Vapor Trap Kit; Includes two oil vapor traps,manual, and aluminaActivated alumina pellets, 500 gramsFunnel, for filling vacuum pump with oilOil, 1 LiterExtended Operating Supplies, includessample tubes, balance tubes, sample tubebrush, reference material, O-rings, frits,ferrules, and stoppersPrepSeal Kit, used to degas and transfer airsensitive samples to an analysis port withoutcontamination.Hanging Filler Rod Accessory Kit, containstwo connectors with hooks attached, two fillerrods, and installation instructions.16-mm Sample Tube Kit; includes two sampletubes with fitting assemblies, filler rods,Dewar covers, O-rings, ferrules, andinstallation instructions.1-in. Sample Tube Kit; includes two sampletubes with fitting assemblies, filler rods,Dewar covers, O-rings, ferrules, andinstallation instructionsSOFTWARE AND -00237-42820-00237-42825-0018CFR Part 11 Confirmsoftware and operator’smanualGemini V software andoperator’s manualC-Tab option; convertsGeminis 2370 and 2375 toGemini 2370C. Uses the tlayer thickness program todetermine the surface areaof carbon black.Room Temperature Option,allows you to measure gasand vapor adsorption onsamples at temperatures inthe range of -70 ºC to 100 ºC.Operator’s manual, Keypadversion, Geminis 2365/2380Operator’s manual,Windows version, Geminis2365/2380Operator’s manual, Gemini2375, for S/N 1200 andlowerOperator’s manual, Gemini2360, for S/N 1201 andhigherOperator’s manual, Gemini2370, for S/N 1201 andhigherOperator’s manual, Gemini2375, for S/N 1201 andhigherMay 2007

Gemini VI and AccessoriesGemini VI and AccessoriesDetermines single- and multipoint BET and Langmuir surfaceareas, total pore volume, and micropore analysis by the t-method.Universal electrical LN2 TRANSFER SYSTEMFor easy filling of sample Dewars. Includes 47-LDewar, mobile stand, and pump with 100-cmdischarge line. Universal voltage input.021-00000-00Gemini VI 2385; with keypadGemini VI 2385; with Windows softwareGemini VI 2385; with CFR Part 11 Confirmsoftware300-25861-202.75 Liters238/31805/00Dewar CoverModel 021REFERENCE MATERIALGAS REGULATOR004-16818-00004-16833-00Glass, SA, 5.8 m2/g, 10 gCarbon Black, 24.1 m2/g, 10 g004-62230-58004-33601-00GLASS BEADSFor displacing volume in the balance tubeequivalent to the volume of sample in thesample tube when analyzing high volume, lowsurface area samples.004-61065-00May 2007004-33602-00CGA 580 fitting, 30 psig (Ar, He, Kr, N2)Expansion Kit; two outlets, includes fittings andinstructions.Pressure Relief Kit; prevents excessive gaspressure in the event of regulator failure. Not tobe used with noxious gases.3 mm, 90 grams19

Gemini VI and AccessoriesGAS INLET ASSEMBLY230-02001-00PORT FRITCopper, 1/8-in. with 1/8-in.Swagelok nut and f

O-RING 004-25078-00 Buna-N, Size 032, for sample chamber cap GAS REGULATOR 004-62230-58 CGA 580 fitting, 30 psig 004-33601-00 Expansion Kit; two outlets, includes fittings and instructions. GAS INLET ASSEMBLY 230-02001-00 Copper, 1/8-in. with 1/8-in. Swagelok nut and ferrules (6-foot length) MANUAL 135-42801-00 Operator's KIT