EMS Viscometer New

Transcription

EMS ViscometerNewtechnologyin the world Small sample volume Disposable sample container Sealed measurementEMS ViscometerEMS - 1000

Measurement Principle of EMS Viscometer* Patent 5093599, US 8,365,582 B2EMS (Electro Magnetically Spinning) MethodRotating speed of aluminum sphere : 1,000rpm

How to operate?

Rotation speed of aluminum spheres10-310-2Low-viscosity10-1100101102103High- viscosity

Various method for determining icViscosityTemp.Control (C) 0 - 200 15 - 150 Viscosity range(mPa・S)0.1 100,0000.3 100,00010 10,000,000-0.2 20,0000.3 100,000sample amount (mL)0.3 -10 -10 -Approx. 2Approx. 2 -2-Accuracy (%)30.15 - 10333Sealed measurement Standard JISJISJISASTMJISVibrationmethodSpinning method

Features of EMS ViscometerPointSmall sample volume & Quick measurement1Point2PointWide measuring rangeVersatile sample container3Point4PointTemperature controlThermal Characteristic by changing tempature5Point6Suitable for air-sensitive samples

Point1Small sample volume & Quick measurementOnly 0.3mL is required!* With optional prove (4.7mm) , 0.7mL is required.

PointWide measuring range20.1 to 100,000mPa・S !!Viscosity 𝜂 mPa gent10,000Honey100,000

Point3Versatile sample containerDisposable !!Cap1. No cleaning required2. AutoclavablePackingSample containerAluminumSphere・for samples whichmust be measured insterile environment3. Sealed measurement・for volatile samples・for anaerobic samples

PointTemperature control4Can control temperature very speedy with accurate !!Approx. 10minutesTemperature ( )250Temp. range : 0 200 Temp. stability : 0.1 Heating rate : 10 minutes200150(25 200 )1005000510Time (min)152025

PointThermal Characteristic by changing tempature58000Sample :Two-component epoxyresin adhesiveViscosity (mPa・s)600060 65 70 40002000002040Time (min)6080

Point6Suitable for air-sensitive samplesCan save space !!Air-sensitive samples:Ionic liquid, Adhesive, Resist,Electrolytic solution of lithium-ion batteryAnother viscometerApparatus should be located underanaerobic condition.EMS methodPour a sample liquid into a samplecontainer under anaerobic condition.

EMS-1000 are used by customers who .R&D ofNew materials・Want to measure sample with wide rangee.g. - Melting point of sample is around 200 .- Measure at the same temperature on shop floor.・Want to check the hardening processe.g. - Viscosity of sample changes on standing , such as epoxy resin・Want to measure with small samplee.g. - Expensive samples such as Antibody, Organic EL material.・Want to throw samples away after measuremente.g. - such as biological sample.- Samples which affect on a human body such as hazardous chemicals.・Want to measure with sealed containere.g. - Samples which volatile easilySamples which have highly hygroscopic.R&D of Raw materialmanufacturerBio technology

ApplicationsBiotechnology・Blood - Temperature dependency of viscosity・Blood - Shear speed dependency of viscosity・Protein - Concentration dependency of viscosity・Yolk – Viscosity change of hardening processChemical・Epoxy type resin – Viscosity change of hardening process・Silicon oil – Wide range temperature dependency of viscosity・Polystyrene – Measurement of dissolution ViscosityPetrochemical・Viscosity of heavy oil and waste oil・Temperature dependency of the viscosity of asphaltCosmetics・Milky lotion – Thixotropy evaluation・Flow properties of lotions

Thank you very much.Dziękuję. Do widzeniaありがとうございます。Danke schÖnGracias非常感謝

EMS-1000 Capillary B-type Rheometer Stabinger Vibration viscometer Method Spinning method Capillary method Spinning method Vibration method Target Absolute Viscosity Kinematic Viscosity Absolute Viscosity Absolute Viscosity Absolute Viscosity Static Viscosity Temp. Control (C) 0 - 200 15 - 150 Viscosity range (mPa・S) 0.1 - 100,000 0 .