DATACENTER SWITCHES IN THE CAMPUS BACKBONE

Transcription

DATACENTER SWITCHES IN THE CAMPUS BACKBONEDan MatthewsManager Network Engineering and Unified Communications, Case Western Reserve University 2015 Internet2

Using Fixed Configuration Data CenterSwitches in the Campus BackboneCONTENTS CC-NIE Cyberinfrastructure Challenge (Background) Evaluating Backbone Upgrade Options Evaluating Upgrade RequirementsEvaluating What is AvailableCampus vs Data Center - Features CWRU Implementation and Experiences Deployment, Topology, BenefitsPerformance Monitoring (SNMP vs Splunk)Buffer monitoring and VXLAN[2] 2015 Internet2

CC-NIE Cyberinfrastructure Challenge (Background) CWRU Received a CC-NIE grant in October 2013– Included Science DMZ Component (100GE to OARnet / Internet2)– Included network upgrades to extend 10GE to research centric buildings and labs Campus Backbone is Aged, Not ready for 10GE to buildings. Current Network Infrastructure is from circa 2003– Distribution routers are pairs of Cisco 6509-E/sup720Base (L3 HSRP)– Core to Distribution is 10GE (WS-X6704-10GE)– Distribution to Building (Access) is 1GE (WS-X6516A-GBIC)– Buildings are dual connected to distribution pairs (Fairly typical campus design) Multiple Pis within “Bingham” distribution collaborated on CC-NIE.– Bingham Distribution contains 20 Buildings– Need to upgrade three to 10GE, the more the better obviously.[3] 2015 Internet2

CC-NIE Cyberinfrastructure Challenge (Background Cont.) Solution 1: Status Quo in the Backbone (Install Line cards)– Install a Cisco WS-6708 and X2-LR optics in each distribution 6509 (List price 149k)– Provides 10GE ports enough for 8 buildings (16 ports @ 9,312.50 list per port).– No other changes required. One of the benefits of chassis gear. Solution 2: Spend that money on something different.Possibly even replace the old equipment altogether.– Lets generate a list of requirements and “nice to haves” for this part of the network.– Lets look at the market and see that what else may meet these requirements at thatprice point. Seek better per port value.– Lets look at feature sets that may provide more options in terms of high performancenetworking and ease of operations. We went with Option 2.[4] 2015 Internet2

Step 1. Take Inventory (What do we really need?) Interface Count and Type– Need 24 optical 1/10GE ports minimum (12 10GE for fair comparison to option 1)– Having 48 would be better for many reasons. L3 Requirements (modest tables sizes, standard protocols)– Needs to support OSPF, OSPFv3, IPV6, a FHRP of some sort.– Needs to support policy based routing, Standard ACLs, QoS– Other standard campus routing needs like IPv4/IPv6 DHCP relay, RPF, PIM– Needs to support 1000 ipv4 routes (Current is less than 500 in these routers)– Needs to support 1000 ipv6 routes (Current is less than 25 in these routers) L2 Requirements– Needs to support Spanning Tree Protocol– Needs to support 10,000 entry CAM table (Currently 5,600)– Needs to support 10,000 entry ARP table[5] 2015 Internet2

Evaluating Backbone Upgrade Options (What's Available?) Traditional Campus Core and Dist Options (Overkill and Expensive)(gleaned vendor web sites and reference designs)– Cisco Catalyst / N7K, HP 5400/7500 , Brocade ICX / MLX, Juniper EX6200/8200– Most are chassis based, most have huge L2 and L3 table capabilities ( 256k ipv4).– Most have power supplies ranging from 2500W to 6000W– Cost per 10GE port ranges from 4,000 to 7,000 list with vendor optics.– Cost per 40GE / 100GE too much for this exercise or just plain not available. Data Center ToR Switches (Sweet spot for Value and Functionality?) – Cisco Nexus 9372px, Arista 7050/7280, Dell S4048-ON, HP 5900AF-48XG, Etc– A lot of 1U fixed 48 SFP , 4 to 6 QSFP, albeit smaller L2 and L3 tables.– Most have efficient power supplies ranging from between 500W and 1200W– Cost per 10GE port between 2,000 and 5,000 list with vendor optics– Cost per 40GE / 100GE still pricy but available with flexible options (break out cables)[6] 2015 Internet2

Campus vs Data Center: Features (Differentiators) Features are comparable, but not the quite the same (see below). Data Center switches offer some neat stuff though. Traditional Campus Core and Distribution Features– Most offer a virtual chassis system. (No FHRP, fewer configs, multi-chassis LAG)– Most offer full MPLS / VPLS implementations.– Some Offer integrated Security / NAC features.– Some offer services line cards (Firewalls / Load Balancers / Wireless Controllers) Data Center Switch Features– Most have some sort of fabric (if you are into that sort of thing). multi-chassis LAG.– Most have VRF / VRF Lite– Most offer “Network Telemetry” and very low latency forwarding.– Most have API / OpenFlow integrations and automation tools (Puppet, Chef, XMPP).– Most offer VXLAN for extending L2 over L3 networks.[7] 2015 Internet2

Campus vs Data Center: Sanity Check Are ToR switches suitable for both IMIX and research flows? Data Center Pros: More ports, Less Power, Less Space, Cool Features– We get 96 10GE capable ports instead of 16 and an upgrade path for all 20 buildings– We get at least a 2x40GE EtherChannel between the pair and Multi-Chassis LAG.– We get a 40GE or 100GE upgrade path for core links.– We get to features like advanced buffer monitoring, automation, VXLAN.– We use way less power, generate less heat, and take up less space. Data Center Cons: Longevity? More Risk.– Shorter life span. No easy (change-less) upgrade path to dense 40GE/100GE.– No operational experience with most of these devices and OSes.– Higher risk overall by replacing all L2 and L3 services with new equipment.– We won’t be able to scale this OSPF area to 256k IPV4 routes bummer[8] 2015 Internet2

Data Center Switch Options Abound Many other Data Center ToR switches might be a good fit in campusbackbones. Some Include – Dell S4048-ON, Cisco Nexus 9372px, Brocade ICX-7750, HP 5900AF-48XG, JuniperQFX 5100-48S. Choose your favorite vendor, I bet they have something to look at. Most are based on merchant silicone. Software and support are key. Many campuses have already started using 1U switches like Cisco 4500-X,Juniper EX4550, etc, as those are cross-marketed as campus and data center.They lack some features of data center offerings. Dense 100GE switches are now on the market or shipping soon.– Dell Z9100, Z6100– Arista 7060CX– Cisco Nexus 3232C[9] 2015 Internet2

Lets roll the dice! We decided to take a shot. If it fails, we can always use the switches in well a data center. We settled on a really new switch at the time, the Arista 7280SE-64. Choosing Arista helped minimize some of the operational risk.– We had been using Arista in HPC for a while so Engineers were familiar with EOS.– We also chose Arista 7500 for HPC / Science DMZ integration. The Arista 7280SE-64 specs exceeded our needs (table sizes, port count)– Based on the Broadcom Arad chipset.– 48 1/10GE SFP , 4 40GE QSFP (typical 4Watt per 10GE port)– 64k IPv4 /12k IPv6 LPM routes, 128k MACs, 96k ARP / Host entries, PIM, VRRP– Buffer Monitoring, VXLAN, Splunk App for Network Telemetry (we like Splunk), MLAG,etc.[ 10 ] 2015 Internet2

Data Center Switches in Campus Backbone: Outcomes Arista 7280SE-64 in production today and working really well.– No VoIP /QoS / Multicast issues.– No packet loss or high CPU or high latency that we have seen. Five Engineering buildings were upgraded to 10GE uplinks. Cost wasless that adding line cards and optics to Catalyst 6509-E. We deployed pairs of Arista 7150S-24 as building aggregators to take care ofthe other side of the links and provide 10GE ports within the buildings. Energy Savings Add Up (Nearly 5k/year per pair)– US Average (All Sectors) is 10.64 Cents /kWhhttp://www.eia.gov/electricity/monthly/epm table grapher.cfm?t epmt 5 6 a– Old equipment costs 5,331.40/yr (4*1430W)/1000)*.1064*24*365– New equipment costs 354.18/yr (4*95W)/1000)*.1064*24*365– If only our budgets recognized this, energy savings pays for maintenance![ 11 ] 2015 Internet2

Data Center Switches in Campus Backbone: Measurement[ 12 ] 2015 Internet2

Actual PerfSonar Throughout Test Graph Hourly PerfSonar 10GE throughput tests from Bingham Dist to Science DMZ[ 13 ] 2015 Internet2

Traditional SNMP Obscures Traffic BurstsThisshowsonly750Mbps.Wherearemyspikes?[ 14 ] 2015 Internet2

Splunk Network Telemetry App: Bandwidth ChartWow!IcanseethePerfSonartrafficBursts![ 15 ] 2015 Internet2

Buffer Monitoring (Also with Splunk App) Looking at buffer (queue) utilization of Bingham Eth 33 (uplink to core) Can you guess when I stopped the 10GE PerfSonar Throughut Tests?[ 16 ] 2015 Internet2

Buffer Monitoring (No Splunk Required) You can see this via the CLI too Might be useful for identifying “microburst” congestion events that could causepacket loss.[ 17 ] 2015 Internet2

Extending your Science DMZ using VXLAN No real bandwidth advantage, but aids in applying consistent security controls andinspection. Make sure the VTEPs have a firewall free path!CWRU ScienceDMZ DeploymentGlennan1GE10 GE40 GE100 lin40GE trunks w/ science DMZand private HPC NetsDTN1PerfSonar-dmzBinghamWhitebingham- ‐h0- ‐e1MLAGPo10Case Backbone129.22.0.0/16sciencerouter0Juniper MX480Rockefellerhpc-rhk15-m1-e1Arista 7508Ebingham- ‐h0- ‐e2NordCC-NIEEngineeringBuildingsCWRU HPCScience DMZ VlanTrunked to Buildinginetrouter1WS-C6509PBR EnabledFW BypassLab SystemCrawfordKSL HPCVXLAN Tunnel[ 18 ] 2015 Internet2

Summary Data Center class ToR L3 switches can work in campus backbonedeployments. Thought must be given to current and mid-term requirements interms of advanced features. The value proposition is compelling in comparison to traditional (or at leastmarketed as traditional) campus core and distribution options. Data Center network equipment is designed with power, heat, and spaceefficiency in mind. Depending on the size of your backbone, this could make adifference for you. Data Center network equipment seems to adopt new networking technologymore rapidly than campus centric offerings. Some of which can be helpful toCyberinfrastructure engineers. Data Center network equipment has a robust set of API and automation toolsthat are not as mature in campus or enterprise offerings. (didn’t have time tocover this next time)[ 19 ] 2015 Internet2

References Brocade List Pricing ingPurchasing/brocade/price list 2014-03-28.pdf Cisco List Pricing http://ciscoprice.com/ Juniper List Pricing juniper-pricelist-mississippi.pdf HP List Pricing atalog/hewlett-packard.html Dell Campus Networking Reference Reference-Architecture.pdf HP Campus Network Design Reference http://www.hp.com/hpinfo/newsroom/press kits/2011/InteropNY2011/FCRA Architecture Guide.pdf Cisco Campus Network Design Reference erprise/Campus/HA campus ise/Campus/Borderless Campus Network 1-0/Borderless Campus 1-0 Design Guide.pdf Juniper Campus Network Design Reference ://www.juniper.net/techpubs/en pdf/905013.pdf Brocade Campus Network Design Reference ks-Network/ta-p/37280[ 20 ] 2015 Internet2