GE Critical Power - I.E.M Company Limited

Transcription

GECritical PowerTLE Series UPS160-800 kVA/kW three phase 400 Vacwith best-in-class efficiencyimagination at workTLE-Series-CE-brochure-GEA-D 1102-GB-y13m10d18.indd 118-10-2013 18:35:20

GE provides clean, efficient and reliable power for today’s digital world with theultra high efficiency TLE Series UPS.GE’s TLE Series Uninterruptible Power Supplies 160-800 kVA/kWThe TLE Series UPS is one of the best performing three-phase UPSsystems providing critical power protection for a wide range ofapplications. The TLE Series operates in VFI mode (Voltage FrequencyIndependent) and has been developed to satisfy the growing requestof high efficiency through an innovative control algorithm with3-level inverter technology. This innovative product provides bestin-class efficiency in double conversion mode as well as eBoost operating mode. The TLE Series is developed using GE’s Design forSix Sigma methodology to help ensure that the product fully meetscustomer requirements and expectations.The TLE Series UPS provides industry-leading reliability, efficiency,clean input performance and unity power factor at output. Reliabilitycan be further increased by paralleling more units utilizing GE’sunique RPA (Redundant Parallel Architecture) technology. Throughtheir complete life cycle, all GE UPS systems are fully supportedby service teams which provide world-class, 24x7 preventive andcorrective services, training and application expertise.Ensuring uptime for critical processesUtility PowerBackupGeneratorsUPSContinuouslycleaning utilitypower and bridgingthe gap between lossof utility power andgenerator availabilityATSTransfers criticalloads to the moststable power source,ensuring sustainableuptimeSPDProtects computers,servers,etc frompower surgescoming from utilityand generator feedsPSGManages generatorstartup andsynchronization,ensuring safety andefficiencyFor mission critical processes,customers rely on our industryleading power quality solutionsto increase critical systemreliability. GE’s Critical Powerbusiness has technology thatdelivers superior performanceand industry-leading energyefficiency for facility backuppower management. Inaddition to our UPS Solutions,we provide the StandbyGenerator ParallelingSwitchgear, AutomaticTransfer Switches and SurgeSuppression Devices thatdeliver power efficiently andreliably.2TLE-Series-CE-brochure-GEA-D 1102-GB-y13m10d18.indd 218-10-2013 18:35:23

TLE Series UPS 160-800 kVA/kWDelivering Best-in-Class Efficiency with Innovative TechnologyGE’s TLE Series UPS is one of the most efficient and reliable three-phaseUPS systems, providing best-in-class efficiency, output performance andcritical power protection for your data center needs. The TLE Series UPSsolutions are optimized to provide high efficiency at part load conditions.The TLE Series UPS helps assure low input current harmonic distortion,best-in-class output voltage regulation and dynamic response. This helpscustomers save operational costs while implementing environmentallyfriendly solutions.Efficiency and Technology Provide Low Total Cost of Ownership High efficiency in double conversion mode up to 96.5% and eBoostmode operation up to 99%. High double conversion efficiency provides substantial life cycle costsaving in power and cooling cost of up to 2 MM for a 6 MW data center Clean input performance keeps the supply network clean and providesadvantages by reducing size of circuit breaker, cables and generator.Easier Installation and Configuration Flexibility True front access for operation and maintenance reduces mean time torepair (MTTR) Standard built in back feed protection and maintenance switch minimizeinstallation cost and increase safety Smaller size reduced installation and operational foot print Redundant Parallel Architecture (RPA) for reliability, redundancy andscalability up to 6 UPSHigh Performance and Availability Enhanced output performance with unit power factor to protect andsupply modern IT load Excellent dynamic performance and low output voltage distortion Improved diagnostic capabilities with waveform capture and capacitormonitoringKey FeaturesClean input performance with 0.99 input powerfactor and 3% THDiDouble conversion efficiency up to 96.5%Output power factor 1True front access designCompact foot printImproved user interfaceExtremely low output voltage distortionSuperior Battery Management3TLE-Series-CE-brochure-GEA-D 1102-GB-y13m10d18.indd 318-10-2013 18:35:32

Energy Efficiency is our focusGE’s TLE Series UPS is one of the most energy efficient double-conversion UPS in the industry, and provides worldclass energy efficiency across the operating load range. The TLE Series delivers efficiency up to 96.5% in doubleconversion mode and 99% in eBoost operating mode. This system efficiency substantially reduces operating andcooling costs thus providing a reduced cost of ownership and improved power usage effectiveness (PUE) compared toconventional UPS.GE’s UPS performance is optimized at 50-75% load operation, as this is the most common operating range. Theoptimization of the TLE Series includes selecting all major power chain components based on maximizing thecomponent efficiency at part load conditions.High Efficiency TLE Series UPS Provides: Substantial reduction in operatingcost of UPSTLE 200 kW UPS EFFICIENCYTLE series delivers efficiency up to 96.5% in double conversion (VFI) modeand 99% in eBoost operating mode98 Energy savings from reduced cooling95EFFICIENCY % Reduced energy loss minimizes airconditioning requirementtypicaloperating load928986838025%50%75%100%LOADTLE VFI ModeTLE eBoost ModeeBooste high efficiency up to 99%Boost fast transfer to inverter 2msTLE Double Conversion (VFI) - 3 Level ConvertersMains Inputinductorstatic bypasspower flowrectifierinverterAC output to thecritical loadloadUp to 96.5% EfficiencyTLE eBoost (VFD)power flowMains InputEnergy consumption is a critical issuefor IT organizations as their datacenterenergy demands continue to grow.Their goal is to reduce cost and keepthe datacenter running. IT organizationscan reduce energy consumption costswithout sacrificing system reliabilitywith GE’s eBoost technology.99% Efficiencyinductorrectifierstatic bypassinverterAC output to thecritical loadloadUp to 99% Efficiency4TLE-Series-CE-brochure-GEA-D 1102-GB-y13m10d18.indd 418-10-2013 18:35:33

High Efficiency – Data Center Life Cycle Cost SavingsThe TLE Series with 96.5% efficiency in double conversion mode and 99% efficiency in eBoost operating modeprovides considerable life cycle cost savings in comparison to a traditional transformer less UPS operating at 94%efficiency. Savings are dependent upon load, power cost and life cycle duration (years).For 6 MW load TLE series provides savings of 2 MM while operating in VFI mode.Assumptions: Power cost 0.10 /kw-hr Operating hours/year 8760 Configuration S S operating at 50% loadData Center Life Cycle Cost (10 Years)TOTAL UPS ENERGY COST ( MM)TraditionalDouble Conversion UPS 2 MM SavingsTLE SeriesDouble ConversionTLE Series eBoostLOAD (MW)eBoost PerformanceSpecificationsInput voltageUtility failureIn case of a mains failure the UPSwill transfer the load to inverter(double conversion) within 2ms.UPS output voltageTransfer to inverterOn TLE Series products, 160-800 kWsingle module and Redundant ParallelArchitecture (RPA) operation:Fast transfer to inverter: 2msInput voltage range: /- 10%Input frequency range: /- 3%Efficiency:up to 99%Extremely fast transfer to inverter( 2ms) in case of utility voltageanomaly or failureeBoost activeDouble conversion active5TLE-Series-CE-brochure-GEA-D 1102-GB-y13m10d18.indd 518-10-2013 18:35:36

Innovative Product Technology3 Level Technology for High EfficiencyThe TLE Series UPS uses a three level technology with anAdvanced Neutral Point Clamped topology implementedwith true Reverse Blocking IGBT. These result in reducedswitching and filter losses with respect to a standard two leveltechnology. Combined with optimized magnetics, the net resultis an ultimate 96.5% efficiency in double conversion mode. Inaddition, the high level of integration and the optimized powerlayout result in clean commutations with no over-voltages whichin turn translate into reduced component stress and increasedreliability.Improved Diagnostic and Reliability withNew DSP ControlEvery TLE Series UPS incorporates improved diagnosticcapabilities with the new FLEX DSP control board thatprovides capability of waveform capture, diagnosticand trend analysis. The TLE Series is also equipped withspecial hardware and monitoring capability for limited lifecomponents like fans and capacitors. Waveform capturing capability Fan failure detectionSuperior Battery Management (SBM) Component life time counters (fan and capacitors)Every GE UPS incorporates a standard feature called SuperiorBattery Management (SBM) that can be configured toperiodically test the battery system and calculate true batteryruntime using measured values for temperature and load. AC capacitor health monitoringAdvantages Works with all battery types: Flooded, VRLA, NiCD Programmable features allow the user to select the frequencyand type of battery tests that are performed:-- Frequency range can be from once per week to onceannually-- Test type range can be from deep cycle to 3-min discharges-- Manual tests can be performed at any time IGBT status diagnosticImproved reliability and availability Dedicated supply for bypass logic Dedicated supply for connectivity channels Redundant logic for emergency bypass activation Main-board integrated RPA control: RPA board containsonly interface hardware More robust RPA communication (Manchester coded)CRC – cyclic redundancy check Temperature compensated battery charger - preventsovercharging Programmable end of discharge voltage - protects againstdeep discharge Deep discharge test (manually) - provides batteryperformance tracking Boost charging - enables fast recharging of batteriesImproved Diagnostic Capability Waveform capture, diagnostic and trend analysis Diagnostic details accessible to service personnel Simultaneous acquisition of 32 channels Sampling frequency up to 10kHz Smart trigger capability with up to 16 independent triggersources to record only specific events with pre/post triggerdata acquisition 8 buffers to record up to 8 events without losing older events6TLE-Series-CE-brochure-GEA-D 1102-GB-y13m10d18.indd 618-10-2013 18:35:36

Input PerformanceOutput PerformanceClean Input PerformanceTotal Harmonic Distortion (THD)The TLE Series IGBT based rectifier and innovative controlalgorithm ensures an input Total Harmonic Distortion (THDi)of less than 3% and draws a pure sinusoidal waveform fromthe mains. This also provides UPS input power factor of 0.99.A distorted output voltage waveform affects the properfunction of the load’s equipment. The TLE Series has very lowoutput voltage THD, even with connected 100% unbalancedor 100% non-linear loads.AdvantagesOutput Power Factor 1 Saving in the sizing of upfront equipment e.g. emergencygenerators, cablings, and circuit breakers TLE Series with unity output power factor provides moreoutput power. Output power factor diagram symmetricalwith respect to zero. 100% kVA – no derating with any load. No disturbances to nearby equipment; eliminateperturbation and outage on upfront electrical equipment,avoiding also any investigation and analysis cost due tomalfunction Suitable for modern power supply application with unit orcapacitive power factor (e.g. new servers generation), crestfactor up to 3:1.Programmable Soft StartTransient ResponseThe programmable soft start allows the rectifier to rampup in a programmable time period (0-15 seconds) thuseliminating in-rush current. This feature reduces the need ofoversizing the input power system (gensets, feeder cables,and overcurrent devices).Transient response is very fast due to control algorithmswhich ensure very high dynamic stiffness. This reduces theneed to oversize the UPS for pulse load applications.Generator CompatibilityUser-programmable features such as slew rate, phase anglerate-of-change and voltage rate-of-change allow the UPS toquickly sync to a genset during emergency back-up.TLE Series Power CapabilityACTIVE POWER 0.7Unity output power factor, fullpower for critical load withoutderating for actual and futureIT loads.FACTOR0.6100% 90807060504030CAPACITIVE POWER (kVAr)201001020Available power30405060708090 100%INDUCTIVE POWER (kVAr)7TLE-Series-CE-brochure-GEA-D 1102-GB-y13m10d18.indd 718-10-2013 18:35:37

Advanced User InterfaceThe TLE Series UPS is equipped with menu-driven touchscreen display panel provides easy to read details onUPS status and metering, parameter settings, UPSconfiguration. This user-friendly display panel provides: Critical measurement of input, output and battery includedwith mimic diagram Quick operational status Measurement and operational status of RPA system Different access level for user and service Multilanguage communication interface supporting: English,German, Italian, Spanish, French, Finnish, Polish, Portuguese,Czech, Slovakian, Chinese, Swedish, Russian and Dutch.TLE Series Ease of Installation &Improved ServiceabilityFront AccessTLE Series is designed to have front access for all thecritical components that reduces mean time to repair(MTTR).Modular & Draw Out ConstructionAll the sub-assemblies for the TLE Series are designedand assembled to have slide out modular constructionthat allows fast maintenance and service.Improved DiagnosticTLE Series new diagnostic features allows to storedifferent wave forms and also provides fan failuredetection as well as warning on capacitor life thatimproves UPS availability and enhances preventivemaintenance capabilities.Standard Safety and Maintenance FeatureTLE Series UPS has standard built in back-feedprotection as well maintenance switch (standard forTLE 160-400 kW) that avoids external installation ofswitches or breakers into input distribution panelsfor providing back feed protection and maintenancedisconnect.Power Quality ServicePerformance Through PeopleWhether you are a large corporation with multiple sites or a small business owner witha single location, GE will enable you to have a constant supply of clean and reliablepower to keep your business up and running.GE has local offices in a number of countries around the globe and also a networkof selected business partners, whose salespeople and service engineers combineexpertise in our solutions with an in-depth knowledge of local market conditions.GE’s service & authorized service providers business partners, located in more than100 countries around the world, use all that expertise and knowledge to adapt GE’sproducts and services precisely to their customers’ needs. On site & emergency services Support and remote services Service agreements Online support Spare parts and repairs8TLE-Series-CE-brochure-GEA-D 1102-GB-y13m10d18.indd 818-10-2013 18:35:40

Redundant Parallel Architecture (RPA) System ConfigurationGE provides RPA, a unique technology that can parallel UPS modules with true redundancy by eliminating any single point of failure. RPAprovides a scalable paralleling technique that reduces operating footprint and increases system reliability by eliminating the need forexternal paralleling equipment and cabinets (centralized bypass and master control).One of the UPS modules in the system intelligently takes the leadership role, while the other UPS modules have access to all controlparameters. If one UPS fails to operate, the load is automatically redistributed among the others. If the lead UPS fails to operate, thenanother UPS automatically takes on the leadership role. GE’s RPA technology is implemented by distributing the control electronics withineach UPS module in the system.RPATM System AdvantagesNo Single Points of FailureThe RPA system provides complete redundancy of all criticalcomponents, allows paralleling of up to 6 units for increasedload capacity or redundancy.Online MaintenanceN 1 configurations allow maintenance on any single module inthe system while other modules provide online protection withbattery backup.Bypass Inductor DesignEnsures excellent output voltage regulation betweenparalleled modules and assists bypass line conditioning(eBoost only).Sequential Soft StartProvides sequential soft start of each module to reduceinstantaneous load on input feeders during mains recovery. Thishelps avoid over-rating of generator and overheating of cable andfuses.Scalable and ModularThe system can be easily expanded for higher capacity andredundancy without any interruption to the critical load ortransfer to bypass.Redundant CommunicationRedundant high speed bus and control electronics providehigher system reliability.Distributed Control LogicEach module in an RPA system has its own operationalcontroller. Each one continuously communicates with allothers in order to manage the entire system like a team.RPA Cable SaverUPS Module input and output cable length variation up to 10%between modules. With eBoost technology this cable lengthflexibility is increased between modules.Smaller FootprintRPA eliminates centralized control and external static bypasscabinet.GE’s RPATM SystemConfigurable up to 6 units inparallelStandard RPATM Configuration:True Redundancy with Distributed Control & BypassUPS 2UtilityCritical loadRedundantcomm busUPS 1 Future expansionUPS 3 Safe and reliable power supply Redundant CommunicationBus Easy to install and maintain Easy system upgrade/downgrade Maintenance operationwithout load interruption.9TLE-Series-CE-brochure-GEA-D 1102-GB-y13m10d18.indd 918-10-2013 18:35:40

Software & Connectivity SolutionsProtection SoftwareGE Data Protection software can communicate with the UPSover RS-232, USB or SNMP to receive status information andmeasurement values of the UPS. In case of a critical condition(time on battery, remaining battery autonomy time or low battery)for the load, the software starts a controlled shutdown.LinuxWindowsUnixAppleLAN switchAn enhanced alarm management system provides the possibilityto start applications, send messages, and send e-mails for everyupcoming or disappearing alarm.Remote Monitoring and Diagnostic Solution (iUPSGuard)GE remote monitoring solution is an anytime, anywhere concept inUPS status monitoring and alarm notification supporting all GE UPSproduct lines.Accessing the latest site information via Web and being alerted byEmail or SMS , it enables the user to make timely decisions in caseof changing critical conditions. With comprehensive data collectionand analysis it improves diagnostics capability and enhancesresponse time. 24/7 remote access to your UPS data using standard web browserdata centerfirewall Automatic alerting in case of event direct and immediately to youcell phone or by email Regularly operational reports with proactive information on criticaldata Preventative information using PMAD (Preventative Maintenance &Advanced Diagnostics) featureinternet@ Possibility to reduce intervention and onsite workSMSRemote Connectivity to Building Management SystemsThis optional Standard Network Management Protocol (SNMP)Plug–In Card allows the UPS to communicate over a LAN orinterface through all major building management systems (BMS).Integrates a modern web server for UPS monitoring Via LAN,drives remote server shutdown in case of critical UPS alarms andworks as Modbus TCP Converter “as well as Modbus RTU 485”.10TLE-Series-CE-brochure-GEA-D 1102-GB-y13m10d18.indd 1018-10-2013 18:35:42

Technical SpecificationsPowerRatingOutput Power rating (kVA)160200320400600800Output Power Rating (kW)1602003204006008003020342024002800Output Power FactorEnergyUsage1EfficiencyUp to 96.5%Efficiency (eBoost mode, option)Up to 99% (Option)Technology Rectifier TechnologyIGBT TechnologyRPAPhysicalsUp to 6 unitsDimensions (w), mm8201420Dimensions (d x h), mm865 x 1905Weight (kg)Input500950Voltage Range340-460 VacFrequency RangeOutput45-65 HzInput power factor0.99Current THD 3%Voltage3 x 380/400/415 Vac, User selectableFrequency50/60 HzVoltage THD at Linear load 1.5%Voltage THD at Non-linear load 5%Voltage Regulation Static /- 1%TopologyGeneralVFI (Voltage Frequency Independent) according to IEC 62040-3Protection DegreeIP 20Ambient operating temperature0 C up to 40 COperating modesDouble conversion, automatic bypass, eBoost mode, frequency converter, RPAStandardCE Mark, IEC 62040-1, IEC 62040-2, IEC 62040-3, IEC 60950Safety StandardsEN/IEC 62040-1EMC StandardsEN/IEC 62040-2ColorRAL 9005, blackSpecifications subject to change without prior noticeUPS Block c BypassBuilt-in Standard FeatureQ2Manual Bypass Standard back-feed protectionSSMK6K4 Integrated maintenancebypass (for TLE 160-400 kW)K7RectifierQ1Built-in UPS OptionsLOAD2. RPA kit (Redundant ParallelArchitecture)InverterBattery ChargerCB31. eBoost Operation Mode3. Kit for common input mains4. Auxiliary Power Supply (APS)24Vdc(Option)External BatteryTLES 160-400 S1 Block diagram GB 015. Surge suppressors11TLE-Series-CE-brochure-GEA-D 1102-GB-y13m10d18.indd 1118-10-2013 18:35:42

your distributor:GE Consumer & Industrial SAVia Cantonale 506595 Riazzino (Locarno)SwitzerlandT 41 (0) 91 850 51 51F 41 (0) 91 850 52 52E info.ups@ge.comimagination at workwww.gecriticalpower.com General Electric Company, USA. All Rights Reserved (10/2013). Reproduction only upon written consent by GE.GE, the GE monogram, TLE Series UPS, eBoost and RPA are trademarks of General Electric Company. GE reserves the right to make changes tospecifications of products described at any time without notice and without obligation to notify any person of such changes.TLE-Series-CE-brochure-GEA-D 1102-GB-y13m10d18.indd 12EnglishGEA-D 1102 GB1026385 / 13101818-10-2013 18:35:42

TLE Series with unity output power factor provides more output power. Output power factor diagram symmetrical with respect to zero. 100% kVA - no derating with any load. Suitable for modern power supply application with unit or capacitive power factor (e.g. new servers generation), crest factor up to 3:1. Transient Response