Product Data Sheet 4656 EZ - Ebmpapst-ventilator.hu

Transcription

Product Data Sheet 4656 EZThe engineer's choice

Product Data Sheet 4656 EZ4656 EZINDEX1General . 32Mechanics . 32.12.23Operating Data . 53.13.23.33.43.54GENERAL . 8CLIMATIC REQUIREMENTS*) . 8Safety . 95.15.26ELECTRICAL OPERATING DATA . 5OPERATING DATA - ELECTRICAL INTERFACE -OUTPUT . 6ELECTRICAL FEATURES. 6AERODYNAMIC. 6SOUND DATA . 8Environment . 84.14.25GENERAL . 3CONNECTIONS . 4ELECTRICAL SAFETY . 9APPROVAL TESTS . 9Reliability . 96.1GENERAL . 903/07/2014page 2 of 10

Product Data Sheet 4656 EZ1GeneralFan typeRotational direction looking at rotorAirflow directionBearing systemMounting positionBalancing eightHousing materialImpeller materialFan without chassisclockwiseAir outlet over flangeBall bearingany2,50,0 mm0,0 mm39,0 mm108,0 mm0,380 kgMetal03/07/2014page 3 of 10

Product Data Sheet 4656 EZ2.2ConnectionsElectrical connectionLength of lead wireWiresL 375,0 mm - 10,0 mmTolerancesee drawingLength of tubeToleranceWire gauge (AWG)Insulation diameterPlugContactWire 1Wire 2182,06 mmsee drawingsee drawingColourblackblackOperationLN03/07/2014page 4 of 10

Product Data Sheet 4656 EZ3Operating Data3.1Electrical Operating DataFor checking purposes the electrical data can be specified without an intake nozzle / aperture plate as well. For thisthe data have to defined by the appropriate quality assurance.Electrical Operating Date with intake nozzel (For checking purposes)MeasurementNormal air density 1,2 kg/m3; Temperature 23 C /- 3 C; Motor axis horizontal; warm-upconditions:time before measuring 5 minutes (unless otherwise specified).In the intake and outlet area should not be any solid obstruction within 0,5 m.Measurement setup:Measured with an aperture plateAperture plate diameter:109 mmDistance between mounting traverse and 20,5 mmaperture plate: p 0: corresp. to free air flow (see section 3.4)I:corresp. to RMS line currentFeaturesFrequencyNominal voltageCondition p 0Symbolf p 0UNTolerancePower consumptionTolerance 6,0 % p 0P p 0nSpeedToleranceValues50 Hz230,0 V- 10,0 %19,0 W - 10,0 %2.600 1/min - 3,0 %03/07/201460 Hz230,0 V 6,0 %- 10,0 %18,0 W - 10,0 %2.950 1/min - 3,0 %page 5 of 10

Product Data Sheet 4656 EZ3.2Operating Data - Electrical Interface -OutputTacho type3.3NoneElectrical FeaturesLocked rotor protectionLocked rotor current at sured with a double chamber intake rig acc. to DIN EN ISO 5801.Normal air density 1,2 kg/m3; Temperature 23 C /- 3 C;In the intake and outlet area should not be any solid obstruction within 0,5 m.Measurement setup:Measured with an aperture plateAperture plate diameter:109 mmDistance between mounting traverse and 20,5 mmaperture plate:a.) Operation condition:2.600 1/min at free air flowMax. free-air flow ( p 0 / max.)Max. static pressure ( p max. / 0)b.) Operation condition:2.950 1/min at free air flowMax. free-air flow ( p 0 / max.)Max. static pressure ( p max. / 0)Frequency: 50 Hz124,0 m3/h72 PaFrequency: 60 Hz142,0 m3/h77 Pa03/07/2014page 6 of 10

Product Data Sheet 4656 EZ03/07/2014page 7 of 10

Product Data Sheet 4656 EZ3.5Sound DataMeasurementconditions:Sound pressure level: 1 Meter distance between microphone and the air intake.Sound power level: Acc. to DIN 45635 part 38 (ISO 10302)Measured in a semianchoic chamber with a background noise level of Lp(A) 5 dB(A)For further measurement conditions see section 3.4a.) Operation condition:2.600 1/min at free air flowFrequency: 50 HzOptimal operating pointSound power level at the optimal operatingpointSound pressure level at free air flow,measured in rubber bandsb.) Operation condition:2.950 1/min at free air flow39,0 dB(A)Frequency: 60 HzOptimal operating pointSound power level at the optimal operatingpointSound pressure level at free air flow,measured in rubber bands4Environment4.1GeneralMin. permitted ambient temperature TU min.Max. permitted ambient temperature TU max.Min. permitted storage temperature TL min.Max. permitted storage temperature TL max.4.242,0 dB(A)-40 C / 50 Hz-40 C / 60 Hz65 C / 50 Hz70 C / 60 Hz-40 C100 CClimatic requirements*)Humidity requirementsWater exposureRadiation exposureDust requirementsSalt fog requirementsHarmful gas requirementshumid heat, constant; according to DIN EN 60068-278, 14 daysNoneNoneNoneNoneNone*) Permittet application area:The product is intended for use in sheltered rooms with controlled temperature and controlled humidity. Directlyexposure to water must be avoided.Pollution degree 1 (according DIN EN 60664-1)There is either no pollution or it occurs only dry, non-conductive pollution. The pollution has no negative impact.03/07/2014page 8 of 10

Product Data Sheet 4656 EZ5Safety5.1Electrical SafetyDielectric strengthDIN EN 60950 (VDE 0805) and DIN EN 60335 (VDE0700)A.) Type testMeasuring conditions: After 48h of storage at 95%R.H. and 25 C.No arcing or breakdown is allowed!All connections together to ground.B.) Routine testMeasuring conditions: At indoor climate.No arcing or breakdown is allowed!All connections together to ground.Isolation resistanceMeasuring conditions: After 48h of storage at 95%R.H. and 25 C measured with U 500 VDC for 1 min.Air and leakage distancesProtection class5.21500 VAC / 1 Min.1500 VAC / 1 Sec.RI 50 MOhm2,0 mm / 1,8 mmIApproval TestsCEULYesYes / UL507, Electric FansYes / Approval acc. to EN 60950 (VDE 0805) - Informationtechnology equipmentNoYes / GB 12350 Safety Requirements for small Power MotorsVDECSACCCThe approval tests are observed to:U approval max.: 230 V / f: 60 Hz @ TU approval max.: 65 C6Reliability6.1GeneralLife expectancy L10 at TU 40 CLife expectancy L10 at TU max.37.500 h / 50 Hz15.000 h / 50 Hz03/07/2014page 9 of 10

Product Data Sheet 4656 EZ 03/07/2014 page 6 of 10 3.2 Operating Data - Electrical Interface -Output Tacho type None 3.3 Electrical Features Locked rotor protection Impedance Locked rotor current at Un 3.4 Aerodynamic Measurement conditions: Measured with a double chamber intake rig acc. to DIN EN ISO 5801.