Osstem Implant 2014-15 Comprehensive Catalog

Transcription

Osstem Implant 2014-15 Comprehensive CatalogOverall Planning/Editing PR Department Design TeamSupervision Implant Lab, Marketing PMProduction/Distribution Marketing & Planning TeamDate of Publication 2014.Publisher Osstem Implant8th FL, World Meridian II, 123, Gasan digital 2-ro,Geumcheon-gu, Seoul, KoreaPhone 82.2.2016.7000Fax ONCONTENTSTS SYSTEMREFERENCE

"Osstem - FutureTechnology andSuperior Quality"Products that dentists can trust.That is the mission ofOsstem Implant.We deeply appreciateall of our customerswho use our products.We deeply appreciate all of our customers who use our products.With population aging, rising incomes, and increased interest in healthand aesthetics, implants have become an essential treatment indentistry around the world.Today, implants are well-known as a safe and effective treatmentoption, and the leading treatment option for patients with no teeth.To satisfy this global trend, Osstem has invested heavily in R&D andcontinuously promotes innovative products, resulting in it becoming aglobal leader in technology and product quality.Osstem is releasing new products including TSIII CA, TSIII BA, SSIIIHA, and MS SA, and is strengthening its product line-up in order toenable application in a variety of clinical cases. Other products to bereleased that will enable safe, easy implant procedures includeSMARTbuilder, AutoBone collector, 123 KIT, and ESSET KIT.TSIII CA in particular is expected to become a leading product in theglobal implant market after launching as a groundbreaking product withsuperior hydrophilic properties capable of at least 30% greater fusionthan ordinary SA products due to its calcium ion solution encapsulation.Also, to improve our customers' convenience and foster reasonablepurchasing, we have opened an online store, DenALL (www.denall.com),where dentistry materials can be purchased affordably and conveniently.Osstem leads the way in superior product quality and exports to over50 countries including the USA, China, Japan, Germany, and India, andis the first company in Korea to record implant sales of over 30 millionproducts and overseas subsidiary sales of over 100 billion won.Osstem Implant CEOGyu-ok Choi (DDS, Ph.D)

2006 Russsia (Mo(Moscow)2011 Canada (Vancouver)(Eschborn))((Esch2011 KazK zakhstan (Almaty)maty)2006 USA (Philadelphia)adelphia)hia)200619972013201013 Tuurkeyrkeyey ((Istanbul)(Isul)20 Me2011exico (Guad(Guadalajara)T iwaTaiwanan (T(TaipeTaipeTi ei)i))20111 BanBangladeshglaglh (Dhaka)(Dh2006201120062007 Australia (SSydney)19972001200601OSSTEM Co., Ltd.Founded01 Obtained CE-043403 Changed company name to 02 Listed on KOSDAQLaunched "Doobunae"(health insurance claimingsoftware)03 Established AIC12certificationTraining CenterOsstem Implant Co., Ltd.04 Obtained GOST-Rcertification in Russia12 Established the firstincorporation stage ofoverseas subsidiaries in 12countries200020020601 Established Osstem10Launched "Hanaro"(dentistry managementsoftware)Acquired Korean companySumin ComprehensiveDental MaterialsImplant Research Center08 Obtained US FDAcertificationLaunched USII implant10 Launched SSII implant2007stock exchange andbegan trading06 Obtained GOST-Rcertification in Russia12 Selected nextgeneration productsObtained certificationfrom Australia'sTherapeutic GoodsAdministration200820102011201301 Established Osstem's03 Launched TSIII SA implant06 Launched TSIII HA implant08 Selected as WPM06 Selected Osstem Implant01 Launched Osstem'sosteology researchcenter12 Selected as a NationalStrategic LeadingTechnology CompanyBiomedical National PolicyCompany12 Exceeded 10,000 dentistrysoftware members200910 Obtained permissionfrom Japan's Ministry ofHealth, Labor, andWelfare to produce andsell medical devicesResearch Center as an ATC(Superior TechnologyResearch Center)07 Selected as a worldchampion businessxenograft "A-Oss"09 Launched K3 unit chair10 Selected as a hiddenchampion business10 Obtained Health Canadacertification12 Launched K2 unit chairSelected as "Global FirstClass Product"201405 Selected as a WorldClass300 business201206 Launched TSIII CA implant07 Established Osstem MedicalEquipment Research Center

Osstem Implant,the leader in popularizing implants in Korea!We stand out with our passion for strategicR&D and best products, creating globallytrend-setting implants.Submerged type implant with an Internal hex 11taper connection structureNon-submerged type implant with anInternal octa 8 taper connectionstructure based on one-time proceduresConnection type and color - Mini/RegularHighest initial stability in soft bone by using uppersection small threadCorkscrew thread & cutting edge- Easy path adjustment through a superior self-threadingeffect- Acquires insertion torque with an increase in soft boneinitial stability and without deviation according to thedrill diametersPackaging Color Information for Each SystemThe various body shape options are available accordingto the bone and patient's clinical condition- TSII (straight body): Easily adjustable insertion depth- TSIII (1.5 taper body): Able to acquire the initial stabilityneeded for immediate loading even in soft bone- TSIV (6 taper body): Able to acquire superior initialstability only in maxillary sinus and soft boneApplied Surface - SA/CA/BA/HASubmerged type implant with an external hexconnection structureConnection type and color - Regular/WideConnection type and color- Mini/Regular/Wide/Wide PSCorkscrew thread & cutting edge- Easy path adjustment through a superior self-threadingeffect- Acquires insertion torque with an increase in soft boneinitial stability and without deviation according to thedrill diametersCorkscrew thread & cutting edge- Easy path adjustment through a superior self-threadingeffect- Acquires insertion torque with an increase in soft boneinitial stability and without deviation according to thedrill diametersThe various body shape options are available accordingto the bone and patient's clinical condition- SSII (straight body): Easily adjustable insertion depth- SSIII (1.5 taper body): Able to acquire the initial stabilityneeded for immediate loading even in soft boneThe various body shape options are available accordingto the bone and patient's clinical condition- USII (straight body): Easily adjustable insertion depth- USIII (1.5 taper body): Able to acquire the initial stabilityneeded for immediate loading even in soft bone- USIV (6 taper body): Able to acquire superior initialstability only in maxillary sinus and soft boneApplied Surface - SA/CA/HAApplied Surface - SA

Osstem Implant provides world-classsurface technologies in surface treatment, thecore implant technology for fast and safeproceduresProvides optimum surface throughacid treatmentSuperhydrophilic SA surfaceencapsulated in calcium solutionSurface coated with low crystallineNano-HA in SAPremium surface coated with highcrystalline HA- Provides Ra 2.5 3.0 surface roughnessHowever, upper section 0.5mm area is Ra 0.5 0.6- Achieved uniform micro-pit 1.3 in size- 46% greater surface area compared to RBM- Maintains optimum surface identical to SA surface- Surface activity maximized after encapsulated incalcium (CaCl2) solution- Increased ossification surface area through excellentblood wettability- Improved bone reaction performance in the earlyosseointegration stage compared to SA surface- Ultra-thin film with HA coating and 10nm or lowerthickness- HA coating on SA surface (Ra 2.5 3.0 )- Dual function of titanium and HAHA is naturally removed during ossification process- High crystalline HA coating 30 60 in thickness- HA coating on RBM surface (Ra 3.0 3.5 )- Achieved at least 98% HA high crystallization- Solves problem of interbody fusion in low crystalline HABone reaction performance(in-vitro and in-vivo)Bone reaction performance(in-vitro and in-vivo)Bone reaction performance(in-vitro and in-vivo)Bone reaction performance(in-vitro and in-vivo)- 20% improvement in osteoblast separation andossification compared to RBM- Initial bone reaction performance in animal model(mini-pig)48% improvement in initial stability (RT, 4 weeks)compared to RBM20% improvement in ossification (BIC, 4 weeks)compared to RBM- 3x increase in protein, cell adhesion compared to SA- 19% increase in initial cell separation (7 days)compared to SA- 34% improvement in initial stability (RT, 2 weeks)compared to SA- 26% improvement in ossification (BIC, 2 weeks)compared to SA- Fused surface having advantages of both SA and HA- Maintains advantage of SA optimum surface formation- Superior early ossification of the HA in soft bonecondition- 30% improvement in ossification (BIC) compared to SA- Excellent biocompatibility in HA that is similar to bone- 2x improvement in osteoblast ossification (5 days)compared to SA- 40% improvement in initial stability (RT, 4 weeks) inanimal models compared to SA- Suitable for weak bone tissue, or tooth extraction orimplant insertion

TS SYSTEMContents016018020022024067069069069070TSII SAFixtureTSIII SAFixtureTSIII CAFixtureTSIII BAFixtureTSIII 031070071071072072TSIV SAFixtureTSIV inerCap ssingMaleLocatorBlock OutSpacersLocatorImpressionCopingLocatorLab AnalogLocatorCore iAbutmentMultiAngledAbutment

FIXTURECOMPONENTS0 160 1802002202402602803003003 66067074075077TSII SA FixtureTSIII SA FixtureTSIII CA FixtureTSIII BA FixtureTSIII HA FixtureTSIV SA FixtureTSIV CA FixtureSimple MountCover ScrewHealing AbutmentCustom Healing AbutmentPROSTHETIC FLOW DIAGRAM 1Rigid AbutmentTransfer AbutmentPROSTHETIC FLOW DIAGRAM 2Angled AbutmentFreeForm ST AbutmentGoldCast AbutmentNP-Cast AbutmentPROSTHETIC FLOW DIAGRAM 3SmartFit AbutmentZiocera (Angled) AbutmentTemporary AbutmentQuick Temporary AbutmentPROSTHETIC FLOW DIAGRAM 4Multi (Angled) AbutmentPROSTHETIC FLOW DIAGRAM 5Convertible AbutmentPROSTHETIC FLOW DIAGRAM 6Stud AbutmentLocator Abutment

TSII SAFixtureD Ø 5.0Hex 2.5Submerged type implant with an internal hex 11 taper connection structureOptimum screw thread design for SA surface to achieve consistent TS2S5011STS2S5013SShortStraight body design for easy adjustment of insertion depthHighest initial stability in soft bone by upper-section thread and body designPowerful self-threading effect using corkscrew threadTS2S5006SRecommended insertion torque: 40Ncm or more※ For a single posterior implant case, use of fixture at least 4.5mm in diameter isHex 1.2recommendedNoMount fixture order codeL: fixture product code (ex : TS2S4010S)Pre-Mounted fixture order code (fixture mount cover screw): B fixture product code (ex : BTS2S4010S)TS SYSTEMTS SYSTEMD016017D Ø 3.5Hex 2.1D Ø 4.0Hex 2.5D Ø 4.5Hex S2M3511S TS2M3513S

TSIII SAFixtureSubmerged type implant with an internal hex 11 taper connection structureOptimum screw thread design for SA surface to achieve consistent roughnessD Ø 5.0Hex 2.5Taper body design with superior initial stabilityHighest initial stability in soft bone by using upper-section thread and body design66Extra shortShortL78.51011.513Powerful self-threading effect using corkscrew threadAcquires the initial stability needed in immediate loading even in soft boneUltra-wideIn implant cases for posterior tooth extraction and immediate insertion andreplacing a failed implantTS3S5005S TS3S5006S TS3S5007S TS3S5008S TS3S5010S TS3S5011S TS3S5013SWith its optimized apex design, capable of extracting a tooth and obtaining initialstability predictably even at the bottom 3mmHex 1.2Recommended insertion torque: 40Ncm or more※ For a single posterior implant case, use of fixture at least 4.5mm in diameter isrecommendedLNoMount fixture order code: fixture product code (ex : TS3S4010S)TS SYSTEMTS SYSTEMPre-Mounted fixture order code (fixture mount cover screw): B fixture product code (ex : BTS3S4010S)DUltra-Wide018D Ø 3.5Hex 2.18.5L1011.513D Ø 6.0Hex 08STS3S7010STS3S7011STS3S7013SL6ShortD Ø 4.0Hex 2.5L7TS3M3508STS3M3510S8.510TS3M3511S TS3M3513S11.513D Ø 7.0Hex 2.5LShortD Ø 4.5Hex S4513STS3S7006S

TSIII CAFixtureSubmerged type implant with an internal hex 11 taper connection structureD Ø 5.0Hex 2.5Superior hydrophilic SA surface encapsulated in calcium solutionTaper body design with superior initial stabilityHighest initial stability in soft bone by using upper-section thread and body S5011CTS3S5013CPowerful self-threading effect using corkscrew threadShortAchieves high initial stability needed in immediate loading even in soft boneUltra-wideIn implant cases for posterior tooth extraction and immediate insertion andTS3S5006Creplacing a failed implantWith its optimized apex design, capable of extracting a tooth and obtaining initialstability predictably even at the bottom 3mmHex 1.2Recommended insertion torque: 40Ncm or more※ For a single posterior implant case, use of fixture at least 4.5mm in diameter isrecommendedLNoMount fixture order code: fixture product code (ex : TS3S4010C)TS SYSTEMTS SYSTEMPre-Mounted fixture order code (fixture mount cover screw): B fixture product code (ex : BTS3S4010C)DUltra-Wide020D Ø 3.5Hex 2.18.5L1011.513D Ø 6.0Hex 08CTS3S7010CTS3S7011CTS3S7013CL6ShortTS3M3508C TS3M3510C TS3M3511C TS3M3513CD Ø 4.0Hex 2.5L78.51011.513D Ø 7.0Hex 2.5LShortD Ø 4.5Hex S4513CTS3S7006C

TSIII BA FixtureD Ø 5.0Hex 2.5Submerged type implant with an internal hex 11 taper connection S3S5011BTS3S5013BSurface coated with low crystalline Nano-HA in SATaper body design with superior initial stabilityHighest initial stability in soft bone by using upper-section thread and body designPowerful self-threading effect using corkscrew threadAchieves high initial stability needed in immediate loading even in soft boneRecommended insertion torque: 40Ncm or more※ For a single posterior implant case, use of fixture at least 4.5mm in diameter isHex 1.2recommendedNoMount fixture order codeL: fixture product code (ex : TS3S4010B)Pre-Mounted fixture order code (fixture mount cover screw): B fixture product code (ex : BTS3S4010B)TS SYSTEMTS SYSTEMD022023D Ø 3.5Hex 2.18.5L10TS3M3508B TS3M3510BD Ø 4.0Hex 2.5D Ø 4.5Hex 2.5LL11.513TS3M3511B 4510BTS3S4511BTS3S4513B

TSIII HA FixtureD Ø 5.0Hex 2.5Submerged type implant with an internal hex 11 taper connection TS3S5011HTS3S5013HPremium surface coated with high crystalline HAShortTaper body design with superior initial stabilityHighest initial stability in soft bone by using upper-section small threadPowerful self-threading effect using corkscrew threadAchieves high initial stability needed in immediate loading even in soft boneTS3S5006HRecommended insertion torque: 35Ncm or lower※ For a single posterior implant case, use of fixture at least 4.5mm in diameter isrecommendedHex 1.2※ HA fixture usage not recommended due to possibility of coating layer cracks inhard bone and disbondingLPre-Mounted fixture order code (fixture mount cover screw): B fixture product code (ex : BTS3S4010H)TS SYSTEMTS SYSTEMD024025D Ø 3.5Hex 2.18.5L1011.513TS3M3508H TS3M3510H TS3M3511H TS3M3513HD Ø 4.0Hex 2.5D Ø 4.5Hex HTS3S4511HTS3S4513H

TSIV SAFixtureUltra-wideSubmerged type implant with an internal hex 11 taper connection structureOptimum screw thread design for SA surfaceFixture for use only in maxillary sinus and soft boneD Ø 6.0Hex 2.5Highest initial stability in soft bone by using more tapered body shape anddeeper thread pitchPowerful self-threading effect using corkscrew 6011STS4S6013S11.513TS4S7011STS4S7013SDue to sharp apex design, even after D4 bone Ø2.0, Ø3.0mm drilling implantinsertion is possibleUltra-wideIn implant cases for posterior tooth extraction and immediate insertion andreplacing a failed implantWith its optimized apex design, capable of extracting a tooth and obtaining initialstability predictably even at the bottom 3mmHex 1.2Recommended insertion torque: 40Ncm or more※ For a single posterior implant case, use of fixture at least 4.5mm in diameter isrecommendedD Ø 7.0Hex 2.5L78.510L※ TSIV fixture insertion is recommended at 15rpm or lower due to large threadpitch and higher insertion speed (or bone expansion feature): fixture product code (ex : TS4S4010S)TS4S7007SPre-Mounted fixture order code (fixture mount cover screw): B fixture product code (ex : BTS4S4010S)TS4S7008STS4S7010STS SYSTEMTS SYSTEMNoMount fixture order codeD026027D Ø 4.0 Pitch 0.8Hex 2.5D Ø 4.5 Pitch 1.0Hex 2.5D Ø 5.0 Pitch 1.2Hex TS4S5010STS4S5011STS4S5013S

TSIV CAFixtureUltra-wideSubmerged type implant with an internal hex 11 taper connection structureSuperior hydrophilic SA surface encapsulated in calcium solutionD Ø 6.0Hex 2.5Fixture for use only in maxillary sinus and soft boneHighest initial stability in soft bone by using more tapered body shape anddeeper thread 011CTS4S6013C11.513TS4S7011CTS4S7013CPowerful self-threading effect using corkscrew threadDue to sharp apex design, even after D4 bone Ø2.0, Ø3.0mm drilling implantinsertion is possibleUltra-wideIn implant cases for posterior tooth extraction and immediate insertion andLreplacing a failed implantWith its optimized apex design, capable of extracting a tooth and obtaining initialstability predictably even at the bottom 3mmD Ø 7.0Hex 2.5Recommended insertion torque: 40Ncm or more※ For a single posterior implant case, use of fixture at least 4.5mm in diameter isL78.510recommended※ TSIV fixture insertion is recommended at 15rpm or lower due to large threadNoMount fixture order codeTS4S7007C: fixture product code (ex : TS4S4010C)028TS4S7008CTS4S7010CTS SYSTEMTS SYSTEMDpitch and higher insertion speed (or bone expansion feature)029D Ø 4.0 Pitch 0.8Hex 2.5D Ø 4.5 Pitch 1.0Hex 2.5D Ø 5.0 Pitch 1.2Hex TS4S5010CTS4S5011CTS4S5013C

Mount & ScrewSimple MountHealing Abutment1.2 Hex driverCUse 1.2 Hex driverPacking unit : mount mount screwC ConnectionHex driver : 1.2Tightening torque : 5 8NcmDHMatching tableTSHAMMHealing AbutmentH3.04.05.07.0AbutmentG/H1.02.0 or 3.03.0 or 4.05.0 이상Impression copingTypeShortShortLongLongFixture levelTS SYSTEMTS A457MTSHA459M3.04.05.07.09.0Ø 4.0TSHA403RTSHA404RTSHA405RTSHA407RTSHA409RØ 4.5TSHA453RTSHA454RTSHA455RTSHA457RTSHA459RØ 5.0TSHA503RTSHA504RTSHA505RTSHA507RTSHA509RØ 6.0TSHA603RTSHA604RTSHA605RTSHA607RTSHA609RØ 7.0TSHA703RTSHA704RTSHA705RTSHA707RTSHA709RØ 8.0--TSHA805R--DCover ScrewC0.4H1.4Long size is used in deep implant insertionHex driver : 1.2Recommended tightening torque : 5 8Ncm2.0HHØ 4.0Ø 4.5Fixture levelDC ConnectionGSCS35GSCS35MHGSCS35LHFixture levelGSCS40S-GGSCS40M-GGSCS40L-G

Custom Healing Abutment7.0Material : medical PEEKCustomizing through easy adjustment and removal toachieve ideal emergence profile5.0Hex driver : 1.2Recommended tightening torque : 5 8NcmPacking unit : abutment Ti screwC ConnectionHAbutment Ti screw order code: product code TH (ex : TSCHAPR7TH)Ti screwFixture levelTS SYSTEMTS SYSTEM0320335.07.09.0Ti screw: GSCHABSMTTSCHAPM5TSCHAPM7TSCHAPM9Ti screw: GSCHABSSTTSCHAPR5TSCHAPR7TSCHAPR9CH

PROSTHETIC FLOW DIAGRAM 1Rigid AbutmentRigid / TransferAbutment Level ImpressionSingleDBridgeRigid Burn-out Cylinder039pFinishingReamer setUsed in producing cement-retained prostheticsGold coloring on gingiva region for improved aestheticsOuter driver : Ø4.0 (242p)Outer driver or 1.2 hex driver : Ø4.5, Ø5.0, Ø6.01.2 hex driver : Ø7.0Recommended tightening torque : 30NcmHG/HPacking unit : abutment protect capRigid Lab AnalogFixture level039pAbutment protect cap order code: product code P (ex : GSRA5620P)TS SYSTEMTS SYSTEMRigid Impression Coping038p034035Rigid Protect CapRigid Retraction Cap038p038pD Ø 4.0HG/H1.0MHexRigid AbutmentRigid Outer Driver,1.2 Hex DriverTransfer Abutment035p(Mini, Regular(Ø4.0) Only Outer Driver)4.05.57.0Non-Hex1.2 Hex Driver040pCover ScrewHealing Abutment030p031pD Ø 4721GSRA4731GSRA4741GSRA47511.2 Hex DriverTSII SATSIII SATSIII CATSIII BATSIII HATSIV SATSIV CA016p018p020p022p024p026p028p4.05.57.0

Rigid AbutmentD Ø 4.0HG/H4.05.57.0D Ø A6730GSRA6740GSRA6750D Ø SRA7640GSRA7650TS SYSTEM2.0TS SYSTEM1.00364.05.57.0D Ø 5.0HG/H4.05.57.0D Ø 6.0H4.05.57.0G/H037

Rigid Abutment ComponentsRigid Protect CapUsed to protect rigid abutments in the oralcavity and minimize foreign body sensationfor the patientAble to be applied in lower structure of atemporary prostheticDH4.05.57.0Rigid Burn-out CylinderDTypeSingleBridgeUsed in attaching a rigid lab analog inframework for prostheticsAfter casting a prosthetic, margin area isadjusted using specialized reamerGSRPC460GSRPC470Ø 4.0/ Ø 4.0GSRP400SGSRP400BØ 4.5/ Ø 4.5GSRPC441GSRPC461GSRPC471Ø 4.5/ Ø 4.5GSRP450SGSRP450BØ 5.0GSRPC540GSRPC560GSRPC570Ø 5.0GSRP500SGSRP500BØ 6.0GSRPC640GSRPC660GSRPC670Ø 6.0GSRP600SGSRP600BØ 7.0-GSRPC760-Ø 7.0GSRP700SGSRP700B0384.05.57.0TS SYSTEMGSRPC440TS SYSTEMØ 4.0/ Ø 4.0Rigid Retraction CapDHDH4.05.57.0Achieves rigid abutment on a working modelProvides an impression with an accuratemargin when taking a direct impressionRigid Impression CopingRigid Lab AnalogØ 4.0 / Ø 4.0GSRRC440GSRRC460GSRRC470Ø 4.5/ Ø 4.5GSRRC441GSRRC461GSRRC471Ø 4.0/ Ø 4.0GSRLA440GSRLA460GSRLA470Ø 5.0GSRRC540GSRRC560GSRRC570Ø 4.5/ Ø 4.5GSRLA441GSRLA461GSRLA471Ø 6.0GSRRC640GSRRC660GSRRC670Ø 5.0GSRLA540GSRLA560GSRLA570Ø 7.0-GSRRC760-Ø 6.0GSRLA640GSRLA660GSRLA670Ø 7.0-GSRLA760-4.05.57.0Ø 4.0/ Ø 4.0GSRIC440SGSRIC460SGSRIC470SØ 4.5/ Ø 4.5GSRIC441SGSRIC461SGSRIC471SØ 5.0GSRIC540SGSRIC560SGSRIC570SØ 6.0GSRIC640SGSRIC660SGSRIC670SØ 7.0-GSRIC760S-DHUsed in taking impressions of rigidabutments039

Transfer AbutmentD Ø 5.0Used in producing cement-retained prostheticsGold coloring on gingiva region for improved 650NDEbonyGold screw: GSABSS1.2 hex driverRecommended tightening torque : 20Ncm(mini), 30Ncm(regular)Packing unit : abutment EbonyGold screwH※ TS transfer abutments and TS rigid abutments have the samemargin upper form. Therefore, all components used in TS rigidHexabutments can be used in TS transfer abutmentsG/HEbonyGoldscrewNon-HexFixture level4.05.57.04.05.57.0Abutment EbonyGold screw order code: product code WH (ex : GSTA4621WH)TS SYSTEMTS SYSTEMD Ø 6.0040D Ø 4.5HG/H1.02.03.04.0HG/H5.0EbonyGold screw: GSABSSEbonyGold screw: GSABSMHexHexNon-HexD Ø 05.0Non-HexD Ø 7.04.05.57.04.05.57.0HG/HEbonyGold screw: GSABSSHexNon-Hex5.57.05.57.0EbonyGold screw: on-Hex5.55.5041

Transfer Abutment ComponentsLaboratory ScrewLab ScrewWaxing ScrewLab screw: Used in apparatus to prevent damage tofinal screwWaxing screw: Used in producing transfer jigs andforming screw holes during wax upBite IndexTakes bite with registration after final impression1.2 hex driverGSABSMLGSABSMW6.08.010.012.0TS SYSTEMGSABSSLØ 12SØ 12SLGSABSSW042TS SYSTEM4.0D043Fixture Lab AnalogAchieves fixture in oral cavity on a working modelGSTLA350GSTLA400

Transfer Abutment ComponentsFixture Pick-up Impression CopingFixture Transfer Impression CopingTakes impression using open tray techniqueSuperior impression stability with an extended flag with a holeTakes impression using closed tray techniqueAccurate impression with gemstone-shaped structure (1.2 hex driver* Label is basic packaging specification1.2 hex driverPacking unit : hex - impression coping guide pinPacking unit : Impression coping body guide pin)non-hex - impression copingGuide xHexNon-Hex044TS SYSTEMNon-Hex9.0TS SYSTEMHex5.0Ø 4.0Ø 4.5Ø 4.0Ø 4.5Ø 5.0Ø 6.0Ø PGPR150*GSPGPM150LGSPGPR150LGuide PinDLTypeØ 4.0Ø 4.5Ø 4.0Ø 4.5Ø 5.0Ø 6.0Ø PR150L*GSPGPR200LØ 4.0Ø 4.5Ø 4.0Ø 4.5Ø 5.0Ø 6.0Ø GSTIS7014GSTIS7014N

PROSTHETIC FLOW DIAGRAM 2Angled AbutmentTransfer / Angled / FreeForm ST /GoldCast / NP-CastFixture Level Impression040pD17 Used when a prosthetic's path adjustment isnecessary at 17。axial angleGold coloring for aesthetics12 orientation choices with two types of hexes, A and BAccurate hex type abutment selection by using anabutment selectorEbonyGold Screw81.2 hex driverRecommended tightening torque : 20Ncm(mini),G/HFixturelevel30Ncm(regular)Packing unit : abutment EbonyGold screwHexNon-HexA TypeB n-HexAngledAbutmentFreeForm 50p052p053pAbutment EbonyGold screw order Code: product code WH (ex : GSAA5020AWH)A typeB typeNon-hexTS SYSTEMTS SYSTEMTransferAbutment046047Fixture Lab AnalogD Ø 4.5042pG/HType2.0Hex AHex B4.0Non-HexHex AHex BNon-HexEbonyGold screw: GSABSMGSAA4520MA GSAA4520MBHexNon-HexHexGSAA4520MNGSAA4540MA GSAA4540MBGSAA4540MNNon-HexFixture Pick-up Impression CopingFixture Transfer Impression CopingBite Index044p045p043pD Ø 4.5Cover ScrewHealing Abutment030p031p1.2 Hex DriverG/HType2.04.0Hex AHex BNon-HexHex AHex 40BGSAA4540NEbonyGold screw: GSABSSTSII SATSIII SATSIII CATSIII BATSIII HATSIV SATSIV CA016p018p020p022p024p026p028p

Angled AbutmentD Ø 5.0G/HTypeAngled Abutment Components2.0Hex AHex

Healing Abutment 032 Custom Healing Abutment Rigid Impression Coping Rigid Abutment Angled Abutment Angled Abutment Selector ZioCera Abutment ZioCera Angled Abutment FreeForm ST Abutment Convertible Combination Cylinder Convertible Angled Cylinder Abutment 065 Multi Angled Abutment. FIXTURE COMPONENTS 016 018 020 022 024 026 028 030 030 031 032