Industrial Rigmaster LED Series Luminaires Enclosed And . - Emerson

Transcription

Industrial Rigmaster LED Series LuminairesEnclosed and Gasketed FixturesNEC/CEC:cCSAus ListedType 3R, 4, 4XIP66NEC/CEC:Simultaneous ExposureSuitable for Use in Wet LocationsAmerican Bureau of Shipping (ABS) CertifiedMarine Outside Type (Salt Water) Applications For use in locations where:— Flammable gases and dusts may be present— A high degree of corrosion resistance is required— Protection against dirt, water and moisture is necessary Typical industries include:— Petrochemical facilities— Waste and sewer treatment— Pulp and paper mills— Food processing plants— Foundries— General manufacturing facilities— Underground tunnelsFeatures Lightweight design makes mounting and installation easy. Low fixture profile allows installation in compact spaces. Two sizes and output options deliver up to 7600 lumens.Fluorescent EquivalentModelNumberNominalLumens 4760032W3T8 Precision engineered clear polycarbonate lens offers wide lightdistribution for greater area coverage. Choice of color temperature (CCT): 5000K cool white, 4000Kneutral white or 3000K warm white with minimum 80 CRI. Field replaceable lens, LED driver, battery pack and batterymanagement module (BMM) Three unique mounting bracket options allow for mounting inany location and retrofitting third party fixtures. For ease of retrofitting, mounting brackets accommodatemost bolt patterns for Crouse-Hinds , Dialight and othermanufacturers. See compatibility chart on page 11. Emergency version is suitable for heights up to 14 feet. Wirenuts and screw terminal block option for addedflexibility. Hinged wire compartment cover is secured with captive screwsfor safety and convenience. Loop in/out wiring capability for inter connecting fixtures Standard screw-type terminal block can accept UL/CSA22-12 AWG wire. 5 casted points for secondary safety retention. Standard 6 kV surge protection. Fixture position locking mechanism provides ease andconsistency of aiming. Rugged housing with superior thermal design translates to longluminaire life. Ambient Temperature: -40 C to 65 C (-40 F to 149 F) Ambient Temperature for Emergency Version: -20 C to 55 C(-4 F to 131 F)Options Brackets can be factory installed or purchased separately Safety cable can be purchased separately or configured as anadd on option to be shipped with the LED fixture. Standard ¾” NPT threads with ½” option. Clear or Diffused Polycarbonate Lens. Emergency battery back up option for 90 or 180 minutes. Wirenuts or screw terminal blocks availableStandard Materials Housing: copperfree (4/10 of 1% max.) aluminumLens: thermal shock- and impact-resistant polycarbonate lensGasket: silicone rubber, mechanically securedBolts: stainless steelClose up plugs: (3) aluminum providedMounting brackets: Zinc plated steelStandard Finishes Housing: gray epoxy powder coat finish, electrostaticallyapplied for complete uniform protectionNEC/CEC Certifications and Compliances UL Standard: UL 924; UL 844; UL 1598; UL 1598A; UL 50E;UL 8750 CSA Standard: C22.2 No. 0 - 10; C22.2 No. 94.2 - 15; C22.2No. 137-18; C22.2 No 141-15; C22.2 No. 250.0 - 18; C22.2 No.250.13 -17; C22.2 No. 60529-16 NEMA ANSI/IEC Standards: 60529 Industrial Rigmaster Standard:— cCSAus: 164460, Certificate Number: 70208309 Industrial Rigmaster Emergency:— cCSAus: 164460, Certificate Number: 70218502DesignLights Consortium Check DLC QPL for current list of products.Related Products Rigmaster LED Luminaries Crouse-Hinds is a registered trademark of Eaton Corporation. Dialight is a registered trademark of Dialight. Applicable to standard (non emergency) fixtures only. Terminal block option available for BU voltage configuration only.Visit our website at www.emerson.com or contact us at (800) 621-1506. October 20201EXPLOSION PROOF LED LINEAR: NEC/CEC Nominal lumen value for 5000K, clear Lens. Detailed lumen informationis provided in data tables. LED L70 of 60,000 hours reported at 65 C ( 149 F). Photometric data and electronic drawings available uponrequest.

Industrial Rigmaster LED Series LuminairesEnclosed and Gasketed FixturesNEC/CEC:cCSAus ListedType 3R, 4, 4XIP66NEC/CEC:Simultaneous ExposureSuitable for Use in Wet LocationsAmerican Bureau of Shipping (ABS) CertifiedMarine Outside Type (Salt Water) Illustrated FeaturesLED Flexibility and Modular DesignHinged wirebox cover withcaptive screws allow hasslefree installation in challengingconditions and preventsaccidental disengagement toenhance workplace safetyNotched position lockingmechanism enables fixture to beaimed consistentlyFive points for secondaryretention provide protectionagainst infield vibration.Rigmaster offers two NPT hubson each end for through wiring.The leads are placed outsidethe wiring compartment tofacilitate plug n play installationso customers can save time andbypass unscrewing the coverChoose from three color temperatures (CCT): 3000K, 4000K, and 5000KStandard linear light distribution pattern: wide distribution maximizes spread and work plane brightness to optimize number ofluminaires neededEXPLOSION PROOF LED LINEAR: NEC/CECConfigurable OptionsMounting Brackets : Choose to mount yourRigmaster using one of three distinctly designedbrackets to best suit your installation needs. Allbrackets can be factory installed to save time inthe field or purchased separately.Wirenuts or Screw Terminal Blocks:Choose between wirenuts and screwterminal blocks for ease of fieldinstallation. Terminal blocks supportUL/CSA 22 to 12 AWG wire.Clear or Diffused Polycarbonate Lens:Select a clear or diffused polycarbonatelens for the optimal level of work planebrightness and visual comfort. Theselenses are field interchangeable forconvenience and flexibilitySafety FeaturesSafety cables can be purchased separately orincluded with fixture to reduce ordering andreceiving complexity Applicable to standard (non emergency) fixtures only. Terminal block option available for BU voltage configuration only. Brackets and safety cables can be ordered separately or included with fixture. See Ordering Table for more information. Mounting Brackets compatible with standard and emergency versions are not the same. please refer to mounting bracket details on page 9 and 10 for details.2Visit our website at www.emerson.com or contact us at (800) 621-1506. October 2020

Industrial Rigmaster LED Series LuminairesEnclosed and Gasketed FixturesNEC/CEC:cCSAus ListedType 3R, 4, 4XIP66NEC/CEC:Simultaneous ExposureSuitable for Use in Wet LocationsAmerican Bureau of Shipping (ABS) CertifiedMarine Outside Type (Salt Water) Order using catalog numbering guides below.IRMA2Series:IRM - IndustrialRigmasterLinear LED2CDHub Size:1 - (4) 1/2" NPT2 - (4) 3/4" NPTMounting :N - If None (Use ifOrdering AppletonBracket Separately)A - Small Swivel BracketB - Large Swivel BracketL - Low Profile BracketBULight DistributionPattern:L - Linear PatternColor Temperature:C - Cool 5000KN - Neutral 4000KW - Warm 3000KLens Material:D - DiffusedPolycarbonateP - ClearPolycarbonateNGW2Color:G - Appleton Gray(Standard)Voltage :BU - 120-277 Vac;125-300 VdcBH - 347-480 VacEmergency:N - If None(Standard)H - 90 MinutesE - 180 MinutesWiring Method:W - Wire Nuts(Standard)T - Fixed TerminalBlock Option :Blank - If None1 - (1) SafetyCable2 - (2) SafetyCables Applicable to standard (non emergency) fixtures only. For lumen output information, see Lumen Values Table. Terminal block option available for BU voltage configuration only. Brackets and safety cables can be ordered separately or included with fixture. See Ordering Table for more information. Mounting option A is not available with emergency version. Emergency battery back up version is only available with BU voltage configuration for 120-277V operation.Visit our website at www.emerson.com or contact us at (800) 621-1506. October 20203EXPLOSION PROOF LED LINEAR: NEC/CECLumen (nominal) :2 - 4,300 Lumens (2')4 - 7,600 Lumens (4')L

Industrial Rigmaster LED Series LuminairesEnclosed and Gasketed FixturesNEC/CEC:cCSAus ListedType 3R, 4, 4XIP66NEC/CEC:Simultaneous ExposureSuitable for Use in Wet LocationsAmerican Bureau of Shipping (ABS) CertifiedMarine Outside Type (Salt Water) Lumen Values Table Lumen Output (Efficacy) for Clear PolycarbonateIRM*2IRM*45000K CCT, 80 CRI4390 (138)7650 (146)4000K CCT, 80 CRI4230 (133)7370 (140)3000K CCT, 80 CRI4160 (131)7250 (138)EXPLOSION PROOF LED LINEAR: NEC/CECLumen Output (Efficacy) for Diffused PolycarbonateIRM*2IRM*45000K CCT, 80 CRI4100 (124)7130 (132)4000K CCT, 80 CRI3950 (119)6870 (127)3000K CCT, 80 CRI3890 (117)6770 (125)Lumen Output in Emergency Mode for Clear Polycarbonate90 Minute180 Minute5000K CCT, 80 CRI13508004000K CCT, 80 CRI12607603000K CCT, 80 CRI1200720Lumen Output in Emergency Mode For Diffused Polycarbonate90 Minute180 Minute5000K CCT, 80 CRI11307004000K CCT, 80 CRI10906803000K CCT, 80 CRI1080670 Applicable to standard (non emergency) fixtures only. All lumen values are typical (tolerance /- 10%)4Visit our website at www.emerson.com or contact us at (800) 621-1506. October 2020

Industrial Rigmaster LED Series LuminairesEnclosed and Gasketed FixturesNEC/CEC:cCSAus ListedType 3R, 4, 4XIP66NEC/CEC:Simultaneous ExposureSuitable for Use in Wet LocationsAmerican Bureau of Shipping (ABS) CertifiedMarine Outside Type (Salt Water) Emergency Battery Backup Functionality - Automatic Testing System (ATS) FunctionalFull DurationStarts within 24 to 45 hours after the initial powerup of the moduleStarts within 5 to 26 days after the initial power of the moduleOccurs every 14 days after the initial aforementioned functional testOccurs every 364 days after the initial aforementioned functional testLasts for 30 secondsLasts for the full duration of the rated emergency periodAt the completion of functional and full duration tests, LED indicator will display the status of the emergency luminaire when AC is presentLED IndicatorLED IndicatorColorTimingDescriptionGreen1 sec ON: 1 sec OFFNormal charging ok, Battery not yet fullycharged, No fault detected, Testing okGreen0.25 sec ON: 0.25 sec OFFFunctional / Duration Self-Test on-goingGreenSteady ONCharging ok, Battery fully charged, No faultdetected, Testing okRed1 sec ON: 1 sec OFFFault condition. Installation issue. Battery isreverse, not connected or shorted.Functional test failure, full durationtest failureLED Indicators OFF, LED Array ONLED Indicator Lights (Red and Green) OFFNo AC, Emergency mode ONEXPLOSION PROOF LED LINEAR: NEC/CECLED Signals Applicable to standard (non emergency) fixtures only. Applicable only for Emergency version.Visit our website at www.emerson.com or contact us at (800) 621-1506. October 20205

Industrial Rigmaster LED Series LuminairesEnclosed and Gasketed FixturesNEC/CEC:cCSAus ListedType 3R, 4, 4XIP66NEC/CEC:Simultaneous ExposureSuitable for Use in Wet LocationsAmerican Bureau of Shipping (ABS) CertifiedMarine Outside Type (Salt Water) Electrical Ratings - Standard Version VoltageInput PowerInput Current (amp)Power FactorTHD120 Vac330.28 0.9 20277 Vac330.12 0.9 20125 Vdc330.27NANAModelBUIRM*2300 Vdc330.11NANA347 Vac360.11 0.9 20480 Vac360.08 0.9 20120 Vac550.5 0.9 20277 Vac550.2 0.9 20125 Vdc550.44NANA300 Vdc550.18NANA347 Vac570.16 0.9 20480 Vac570.12 0.9 20VoltageInput PowerInput Current (amp)Power FactorTHD120 Vac390.35A 0.9 20277 Vac390.15A 0.9 20120 Vac600.57A 0.9 20277 Vac600.20A 0.9 20BHEXPLOSION PROOF LED LINEAR: NEC/CECBUIRM*4BHElectrical Ratings - Emergency Version BUModelIRM*2BUIRM*4 Applicable to standard (non emergency) fixtures only. All lumen values are typical (tolerance /- 10%)6Visit our website at www.emerson.com or contact us at (800) 621-1506. October 2020

Industrial Rigmaster LED Series LuminairesEnclosed and Gasketed FixturesNEC/CEC:cCSAus ListedType 3R, 4, 4XIP66NEC/CEC:Simultaneous ExposureSuitable for Use in Wet LocationsAmerican Bureau of Shipping (ABS) CertifiedMarine Outside Type (Salt Water) Standard Mounting BracketsDescriptionWeightkg (lbs)Catalog NumberSmall Swivel Bracket0.74(1.7)RMSSBLarge Swivel Bracket1.1(2.4)RMLSBLow Profile Bracket0.80 (1.8)RMLPBDescriptionWeightkg (lbs)Emergency Version Mounting BracketsCatalog Number2.0 (4.4)RMHLSBRigmaster Emergency LowProfile Bracket1.9 (4.1)RMHLPBEXPLOSION PROOF LED LINEAR: NEC/CECRigmaster Emergency StandardSwivel Bracket Applicable to standard (non emergency) fixtures only.Visit our website at www.emerson.com or contact us at (800) 621-1506. October 20207

Industrial Rigmaster LED Series LuminairesEnclosed and Gasketed FixturesNEC/CEC:cCSAus ListedType 3R, 4, 4XIP66NEC/CEC:Simultaneous ExposureSuitable for Use in Wet LocationsAmerican Bureau of Shipping (ABS) CertifiedMarine Outside Type (Salt Water) )).)).)).)).).))).)))).))).) . ).) . )) . )) . ). )) . ).) . ).) . )) .).))).)).)) . )BRACKET MOUNTING))BRACKET MOUNTING.)).).)).).).)).)))))).RMLSB - Standard)RMSSB - Standard)LOCKING SCREW)LOCKING SCREWEXPLOSION PROOF LED LINEAR: NEC/CEC.).).) . ).)) . ).)).)Dimensions in Millimeters (Inches).) .) .))))))LOCKING SCREWSDIAGONALLY OPPOSITELOCKING SCREW))BRACKET MOUNTINGRMLPB - Standard Applicable to standard (non emergency) fixtures only.8Visit our website at www.emerson.com or contact us at (800) 621-1506. October 2020

Industrial Rigmaster LED Series LuminairesEnclosed and Gasketed FixturesNEC/CEC:cCSAus ListedType 3R, 4, 4XIP66NEC/CEC:Simultaneous ExposureSuitable for Use in Wet LocationsAmerican Bureau of Shipping (ABS) Certified. Water) Marine Outside Type (Salt. .Dimensions in Millimeters (Inches). . .EXPLOSION PROOF LED LINEAR: NEC/CEC.RMHLSB - Emergency. . .RMHLPB - Emergency Applicable to standard (non emergency) fixtures only.Visit our website at www.emerson.com or contact us at (800) 621-1506. October 20209

Industrial Rigmaster LED Series LuminairesEnclosed and Gasketed FixturesNEC/CEC:cCSAus ListedType 3R, 4, 4XIP66NEC/CEC:Simultaneous ExposureSuitable for Use in Wet LocationsAmerican Bureau of Shipping (ABS) CertifiedMarine Outside Type (Salt Water) Retrofit Bracket Compatibility Chart For customers trying to retrofit an existing fixture, use the table below as a guide to select the best bracket to suit your needsManufacturerPart NumberRMSSB Small Swivel BracketRMLSB Large Swivel BracketRMLPB Low Profile BracketCrouse Hinds ight AZZ Rig-A-Lite Retrofit bracket Compatibility - Emergency Version EXPLOSION PROOF LED LINEAR: NEC/CECFor customers trying to retrofit an existing fixture, use the table below as a guide to select the best bracket to suit your needsManufacturerPart NumberRMHLSBRMHLPBCrouse Hinds DP1057MTKXXLTXW4XXLTXW4LPXXLSXW4XX53050XXDialight AZZ Rig-A-Lite Other Accessories and Replacement PartsDescriptionCatalog NumbersSafety CablesStainless Steel Safety CablesLEDSC—Replacement Battery Management ModuleBMMRM—Replacement Battery PackBPMLLED Applicable to standard (non emergency) fixtures only. The above information is strictly for guidance purposes and does not guarantee compatibility and fit. Please carefully review bolt patterns on each bracket toensure it meets your needs Crouse-Hinds is a registered trademark of Eaton Corporation. Dialight is a registered trademark of Dialight. AZZ and Rig-A-Lite are registered trademarks of AZZ.10Visit our website at www.emerson.com or contact us at (800) 621-1506. October 2020

Industrial Rigmaster LED Series LuminairesEnclosed and Gasketed FixturesNEC/CEC:cCSAus ListedType 3R, 4, 4XIP66NEC/CEC:Simultaneous ExposureSuitable for Use in Wet LocationsAmerican Bureau of Shipping (ABS) CertifiedMarine Outside Type (Salt Water) Replacement DriversVoltageDriver WattageLuminaire ModelConstant Current SettingsCatalog NumberBU50WIRM*2600mAAPM050C135UD060BH50WIRM*2600 mAAPM050C135HD060BU50WIRM*41040 mAAPM050C135UD104BH50WIRM*41040 mAAPM050C135HD104Replacement LensesDescriptionLuminaire ModelQuantity per e LensCatalog NumberRMCLDiffusedPolycarbonate LensRMDLOther Mounting OptionsDimensions in Millimeters (Inches)BCDEWeightper 100 kg (lbs)52.3(2.06)50.8(2.00)35.1(1.38)25.4(1.00)3/8 - 1637.65 (83.00)CatalogNumberMax Loadkg (lbs)EXPLOSION PROOF LED LINEAR: NEC/CECABeam ClampsBH-502E-Tapping340.00(750.00)LoadAccessories and Replacement PartsDescriptionCatalog NumbersHalf Clamp Brackets for Pole Mounting (set of two) For 42 mm to 49 mm pole (1-1/4 to 1-1/2" tube)316 stainless steelFEHC49S For 60 mm pole (2" tube)316 stainless steelFEHC60S Zinc plated steel conduit hanger with swingboltsH75-SWBConduit Clamps Applicable to standard (non emergency) fixtures only. Additional hardware (not supplied) is required to use this accessory with the Rigmaster fixture and mounting bracket. please use two M8 x 20mm bolts,two M8 split lock washers and two M8 nuts. for additional details contact Appleton Technical Support. For compatibility of other Appleton conduit clamps, contact Appleton Technical Support.Visit our website at www.emerson.com or contact us at (800) 621-1506. October 202011

Industrial Rigmaster LED Series LuminairesEnclosed and Gasketed FixturesNEC/CEC:cCSAus ListedType 3R, 4, 4XIP66NEC/CEC:Simultaneous ExposureSuitable for Use in Wet LocationsAmerican Bureau of Shipping (ABS) CertifiedMarine Outside Type (Salt Water) Dimensions in Millimeters (Inches)319 mm(12.6)249 mm(9.8)600 mm(23.6)100 mm(3.9)111.6 mm(4.4)80.9 mm(3.2)106.7 mm(4.2)18.1 mm(0.7)WIRING COMPARTMENTCONDUIT/CABLE ENTRYOPTIONS HUB SIZE 3/4”OR 1/2” OR M20(2 PER SIDE)IRM*2 - StandardCONDUIT/CABLEENTRY(2 PER SIDE)111.6 mm(4.4)1100 mm(43.3)80.9 mm(3.2)18.1 mm(0.7)88.6 mm(3.5)249 mm(9.8)100.0 mm(3.9)EXPLOSION PROOF LED LINEAR: NEC/CEC319 mm(12.6)IRM*4 - StandardModelProduct Lengthm (ft)Product Weightkg (lb)IRM*20.6 (2.0)3.7 (8.2)IRM*41.1 (3.6)4.6 (10.1) Applicable to standard (non emergency) fixtures only.Note: weight of brackets are provided separately12Visit our website at www.emerson.com or contact us at (800) 621-1506. October 2020

Industrial Rigmaster LED Series LuminairesEnclosed and Gasketed FixturesNEC/CEC:cCSAus ListedType 3R, 4, 4XIP66NEC/CEC:Simultaneous ExposureSuitable for Use in Wet LocationsAmerican Bureau of Shipping (ABS) CertifiedMarine Outside Type (Salt Water) Dimensions in Millimeters (Inches)IRM*2 - EmergencyEXPLOSION PROOF LED LINEAR: NEC/CECIRM*4 - EmergencyModelProduct Lengthm (ft)Product Weightkg (lb)IRM*2 - Emergency0.6 (2.0)7.6 (16.8)IRM*4 - Emergency1.1 (3.6)8.6 (19.0) Applicable to standard (non emergency) fixtures only.Note: weight of brackets are provided separatelyVisit our website at www.emerson.com or contact us at (800) 621-1506. October 202013

Industrial Rigmaster LED Series LuminairesEnclosed and Gasketed FixturesNEC/CEC:cCSAus ListedType 3R, 4, 4XIP66NEC/CEC:Simultaneous ExposureSuitable for Use in Wet LocationsAmerican Bureau of Shipping (ABS) CertifiedMarine Outside Type (Salt Water) Photometric Data — DATA SHOWN IS ABSOLUTE2ft, Clear Polycarbonate Lens, 5000K CCTLuminaire Lumens 4,474.5POLAR CANDELA DISTRIBUTION180 170 160 150 1,600130 1,067120 800533110 267100 090 26780 53370 4321012344321060 1,0671,3332420 fc10 fc5 fc2.5 fc50 0 10 20 30 40 - Max CD: 80 H- 0 H- 90 .852.6LUMENS PER ZONE% 01.2%170-18013800EXPLOSION PROOF LED LINEAR: NEC/CECZONAL LUMEN SUMMARY140 1,3331,600ISOFOOTCANDLE PLOT1 fc0.5 fc0.2 fc0.1 fcPoint of Max FC: 4.43Mounting Height 10ftTotal LLF: 0.9- 45 HZone0-1010-2020-3030-4040-5050-6060-7070-8080-90% s0.70.10000.00.10.10.0% 0.30.1% Total0%0%0%0%0%0%0%0%0%4ft, Clear Polycarbonate Lens, 5000K CCTLuminaire Lumens 7,699.2POLAR CANDELA DISTRIBUTION180 170 160 150 2,800ISOFOOTCANDLE PLOTZONAL LUMEN SUMMARY140 2,333130 43210123441,867120 1,400933110 467100 090 46780 93370 21060 1,8672,33350 0 10 - 0 H- 90 H20 30 40 81,029.4343.588.1LUMENS PER ZONE% 10090-1200-9090-1800-180420 fc10 fc5 fc2.5 fc- 45 H1 fc0.5 fc0.2 fc0.1 fcPoint of Max FC: 8.79Mounting Height 10ftTotal LLF: 0% Luminaire23.4%39.8%81%19%5.6%0%100%0%100% Applicable to standard (non emergency) fixtures only.14Visit our website at www.emerson.com or contact us at (800) 621-1506. October 2020

Industrial Rigmaster LED Series LuminairesEnclosed and Gasketed FixturesNEC/CEC:cCSAus ListedType 3R, 4, 4XIP66NEC/CEC:Simultaneous ExposureSuitable for Use in Wet LocationsAmerican Bureau of Shipping (ABS) CertifiedMarine Outside Type (Salt Water) Photometric Data — DATA SHOWN IS ABSOLUTE2ft, Diffused Polycarbonate Lens, 5000K CCTLuminaire Lumens 4001.8POLAR CANDELA DISTRIBUTIONISOFOOTCANDLE PLOTZONAL LUMEN 93.78.24,001.8% MENS PER ZONE% 01.3%170-180Lumens0.30.71.11.31.41.31.00.70.3% 1.00.4% Total0%0%0%0%0%0%0%0%0%Photometric Data — DATA SHOWN IS ABSOLUTE4ft, Diffused Polycarbonate Lens, 5000K CCTLuminaire Lumens 6704.4POLAR CANDELA DISTRIBUTIONISOFOOTCANDLE PLOTZONAL LUMEN .013.16,704.1% 90.5LUMENS PER ZONE% 01.4%170-180 Applicable to standard (non emergency) fixtures only.Visit our website at www.emerson.com or contact us at (800) 621-1506. October 202015EXPLOSION PROOF LED LINEAR: 180

Industrial Rigmaster LED Series LuminairesEnclosed and Gasketed FixturesNEC/CEC:cCSAus ListedType 3R, 4, 4XIP66NEC/CEC:Simultaneous ExposureSuitable for Use in Wet LocationsAmerican Bureau of Shipping (ABS) CertifiedMarine Outside Type (Salt Water) Photometric Data — DATA SHOWN IS ABSOLUTE2ft Clear Polycarbonate Lens, 5000K CCT - Emergency ModeLuminaire Lumens 1,364.9EXPLOSION PROOF LED LINEAR: NEC/CECPOLAR CANDELA DISTRIBUTIONISOFOOTCANDLE PLOTZONAL LUMEN 364.7% ns37.0109.8176.3226.1271.8285.1178.471.26.2LUMENS PER ZONE% 00.5%170-180Lumens0.20.20.30.50.50.50.40.30.1% 0.20.1% Total0%0%0%0%0%0%0%0%0%4ft Clear Polycarbonate Lens, 5000K CCT - Emergency ModeLuminaire Lumens 1,360.2POLAR CANDELA DISTRIBUTIONISOFOOTCANDLE PLOTZONAL LUMEN 360.0% ns36.1107.7174.9225.7273.7286.7177.370.46.2LUMENS PER ZONE% 00.5%170-180 Applicable to standard (non emergency) fixtures only.16Visit our website at www.emerson.com or contact us at (800) 621-1506. October 2020

most bolt patterns for Crouse-Hinds , Dialight and other manufacturers. See compatibility chart on page 11. Emergency version is suitable for heights up to 14 feet. Wirenuts and screw terminal block option for added flexibility. No.Hinged wire compartment cover is secured with captive screws for safety and convenience.