Email Web AL ROUF LED LIGHTING Main Catalogue Final-2

Transcription

LIGHTIS A GIFTTHATEVERYPEOPLEDESERVEalroufled.com

TABLEOFCONTENTS03Company’s04Project Cycle05Project Completed06Case Study07Lighting Design09List of Clients11Luminaires20Obstruction Light28Luminaires40Luminaires42Luminaires47Vendor CodeIntroductionSipchemReturn of InvestmentIndustrial LightsIndoor LightsGas Station LightsRetail Lightsalroufled.com

INTRODUCTIONIN TODAY'S WORLD NATURAL RESOURCESSAVING IS ONE OF THE MAIN POINTS THATTAKES A HEADLINE IN EACH AND EVERYCOUNTRIES' LEADERS.MEETING, NOT ONLY THAT BUT ALSO HOWTO GO GREENER IN TERMS OF POWERCONSUMPTION IN ALL FIELDS.AL ROUF LED LIGHTINGTECHNOLOGY CO. LTD. WAS BORN TOPLAY THE MAIN ROLE IN ENGINEERED LEDLIGHTING SOLUTION, OUR WORKINGTEAM HAVE DEVELOPED SKILLS. ON DAILYBASIS IN ALL LIGHTING APPLICATIONFIELDS SPECIALIZATION IN RETAIL,HOSPITALITY, AND INDUSTRIAL LIGHTINGSGAVE US THE FLAVOR WE HAVE BEENLOOKING FOR.BY THAT CONCEPT AND FOLLOWING THISDREAM, ALROUF HAVE SPENT THE PASTTHREE YEARS WORKING WITH THE TOPMANUFACTURES AROUND THE WORLD TODEVELOP PRODUCTS THAT SUITS THEHARSH ENVIRONMENTAL SITUATION ONSAUDI ARABIA. FROM SMALL SCALE TOLARGE PROJECTS, HIGH & LOW PROFILE.NO MATTER WHAT TYPE, SIZE, LOCATION,AGE, SYSTEM YOU HAVE WE ARE THERETO HELP YOU BE MORE EFFICIENT.alroufled.com3

PROJECT CYCLE1SITESURVEYIN THIS STAGE WE COLLECT ALL THE NEEDED DATA SUCH ASFACILITY APPLICATION, EXISTING LIGHTING SYSTEM, POWERCONSUMPTION, CAD DRAWING AND ENVIRONMENT.LIGHTINGDESIGNWE PUT ALL COLLECTED DATA INTO THE TABLE, AND WE USE THELATEST TECHNOLOGY IN LIGHTING DESIGN (DIALUX) TO GET THEBEST LIGHTING SOLUTIONS.PROJECTPROPOSALPROJECT PROPOSAL WE MAKE 2 OR 3 DIFFERENT SOLUTIONS THATHAVE VARIATION OF COST AND SAVINGS DEPENDING ON THE SITEAND CLIENT REQUIREMENTS.RETURN OFINVESTMENTSFOR EVERY SOLUTIONS WE SUBMIT RETURN OF INVESTMENTSTUDY THAT EXPLAINS AN IN DEPT DETAILS OF THE SAVINGS ANDINITIAL COST OF THE SOLUTION AND THE PAYBACK PERIOD.2345SAMPLEINSTALLATION6WE ALWAYS ADVICE OUR CLIENTS TO INSTALL FREE OF CHARGESAMPLES TO ENSURE OUR DESIGN RESULTS AND AT THE SAME TIMETHE CLIENTS CAN PERCEIVE OUR LIGHTING SOLUTIONS IN AREALISTIC VIEW.LOGISTICANDDELIVERYWE WORK HAND TO HAND WITH THE SUPPLIER AND THE COURIERTO DELIVER THE GOODS IN THE SHORTEST TIME. THE CLIENT ISALWAYS UPDATED BY ALL MEANS. IN TERMS OF COURIER WEALWAYS WORK WITH THE BEST REGARDLESS OF THE COST ORVALUE OF THE PROJECT.INSTALLATIONWE WILL BE THERE IN ALL PHASES OF THE PROJECT GIVING ALLTHE NEEDED SUPPORT BY THE CLIENT. WE EVEN DO TURNKEYPROJECTS IF REQUESTED BY THE CLIENT.78CUSTOMERTRAININGWE PROVIDE TRAINING FOR ANY CONTRACTOR WHO WILL DO THEJOB FOR THE END CLIENT. WE ALWAYS SUPPORT THEM WHENTECHNICAL ISSUES ARISES.AFTER SALESSERVICESWARRANTY AND MAINTENANCE SERVICE ARE ISSUED TO ALLCLIENTS AROUND THE COUNTRY OR REGARDLESS WHERE IS THELOCATION OF THE CLIENT94alroufled.com

TYPE OF LIGHT: HIGHBAY LIGHT (BEFORE):LUX (RANGE): 150LX-200LXLOCATION OF INSTALLATION: SHOAIBATYPE OF LIGHT: HIGHBAY LIGHT (AFTER):LUX (RANGE): 500LXLOCATION OF INSTALLATION: SHOAIBATYPE OF LIGHT: LINEAR LIGHTLUX (RANGE): 1000LX-1100LXLOCATION OF INSTALLATION: PANDATYPE OF LIGHT: TRACK LIGHTLUX (RANGE): 1500LXLOCATION OF INSTALLATION: PANDATYPE OF LIGHT: TRACK LIGHTLUX (RANGE): 1500LX CRI: 90LOCATION OF INSTALLATION: PANDAPROJECTCOMPLETEDTYPE OF LIGHT: HIGHBAY LIGHTLUX (RANGE): 400LX-500LXLOCATION OF INSTALLATION: SAUDI SULBTYPE OF LIGHT: FLOODLIGHTLUX (RANGE): 600LXLOCATION OF INSTALLATION: ARABIAN PIPESalroufled.comTYPE OF LIGHT: STREET LIGHTLUX (RANGE): 50LX-75LXLOCATION OF INSTALLATION: SEC5

CASESTUDYSIPCHEM REFORM AREA COMBINATIONOF HIGHBAY AND AREA LIGHT IS NOTONLY INEFFICIENT AND UNACCEPTABLEFOR THE CONTINUOUS EMITTINGHIGHER DEGREE TEMPERATURE, BUTTHEY ALSO MAKE IT DIFFICULT FORSTAFF TO PERFORM THEIR WORKWITHOUT THE USE OF SUPPLEMENTAL,TEMPORARY, PORTABLE LIGHTS. INADDITION, ONGOING MAINTENANCE ISA CHALLENGE. WORKER MUST BUILDSCAFFOLDING AND TIMELY CHANGINGLAMPS AND ACCESSORIES WITHPORTABLE LIGHTING. HEAT EMISSIONFROM EQUIPMENT CAUSING FIXTUREFAILURES, SO MAINTENANCE IS ANON-GOING PROCESS.OUR DESIGNERS WORKING FOR ABETTER SOLUTION, AIMING TO LIGHTTHE FACILITY WITH THELATEST-GENERATION LED FIXTURE TOPROVIDE THE MOST ENERGY-EFFICIENT,SAFE AND RELIABLE ILLUMINATION.THEREFORE WE PROPOSED A NEWDESIGN WITH DIALIGHT FLOOD LIGHTTO ILLUMINATE A LIGHT BETWEENAISLE ALONG WITH AREA LIGHT FORPASSAGE. THE GOALS FOR THESE TOREDUCE TOTAL CONSUMPTIONMAXIMIZE LIGHTING EFFICIENCY,IMPROVE SUSTAINABILITY AND SAFETYAND REDUCE MAINTENANCE DEMANDAND LOWER TOTAL OPERATING COST.6alroufled.com

LIGHTING DESIGNALROUF LIGHTING TECHNOLOGY CO. LTD WAS NOT JUST A REGULAR TRADER THAT ONLYDEALS IN SELLING LAMPS, BUT WE ARE PROUD TO TAKE IMMENSE EFFORT THAT WE ARECAPABLE ON DESIGN, SELL AND BUILD AS WELL BY OUR WELL EXPERIENCEDPROFESSIONALS. AND AS OUR WORK CULTURE WE PROVIDE OUR RESPECTED CLIENTS WITHFREE LIGHTING AUDIT /SURVEY, CONSULTATIONS, LIGHTING DESIGN, STUDY OR ROI FOR FREEMOSTLY ALL OF THE TIME.WE PROVIDE THESE SERVICES TO ACHIEVE GREAT RESULTS BENEFICIAL TO OUR CLIENT BYMEETING THEIR NEEDS BY ILLUMINATION AND SAVINGS WITHOUT SACRIFICING NATURE.DOING THIS WE FOCUS ON THREE FUNDAMENTAL ASPECTS OF THE ILLUMINATION OFBUILDINGS OR SPACES.THE FIRST IS THE ERGONOMIC ASPECT: THE MEASURE OF HOW MUCH OF A FUNCTION THELIGHTING PLAYS.NEXT IS ENERGY EFFICIENCY, ENSURING THAT LIGHT IS NOT WASTED BY OVER ILLUMINATIONWHICH OCCURS EITHER BY ILLUMINATING VACANT SPACES UNNECESSARILY OR BYPROVIDING MORE LIGHT THAN NEEDED FOR THE AESTHETICS OR THE TASK.LASTLY, AESTHETIC APPEAL OF A BUILDING OR SPACE TO BE LIGHTED, AN ASPECTPARTICULARLY IMPORTANT IN THE ILLUMINATION OF ANY ENVIRONMENTS BUT MORE ON TORETAIL INDUSTRY BUT NOT LIMITED TO IT.alroufled.com7

RETURN OF INVESTMENTPANDA P201 JEDDAH STORETri ProofLights(Warehouse)60 X 60(Office Area)Down Lights(Toilets)Down Lights(Corridors)Linear(Sales Area)Track Lights(Fresh Area)Existing Replaced Existing Replaced Existing Replaced Existing Replaced Existing Replaced Existing LightsLights2X36 Lights 4X36 Lights 2X26 Lights 2X26 Lights 2X58 Lights (70w) Lights(72w) (43w) (144w) (41w) (52w) (15w) (52w) (19w) (116w) (50w) (70w) (34w)Light SourceLamp Power (Watts)72431444152155219116507034Ballast or Driver Power Lamp LifeWarranty for Lamp (years)Luminaire CostEmergency Backup Luminaire CostLamp Maintenance Cost(Cost of Lamp Cost of Gears frequency of Replacement yearly)200200200200ROI CONSIDERATIONPOINTS50K, 10-15KHrsHrs50K,HrsMaintenance Installation Cost (Labour)250250250250250250Luminaire 9356561717292949129535535T. OF INITIAL COST INVESTMENTS FOR THE REPLACED LED ITEMSEmergency Backup Luminaire QuantityT. Luminaire Quantity Including EMKPower Rate per kw-hr in (SAR)INSTALLATION COST FOR REPLACED ITEMSSAR 0.30 SAR 0.30 SAR 0.30 SAR 0.30 SAR 0.30 SAR 0.30 SAR 0.30 SAR 0.30 SAR 0.30 SAR 0.30 SAR 0.30 SAR 0.30System Usage/day in (hrs)24COST0%DimmingT.Levelto % OF CONSUMPTIONHours of Dimming /Day0242424242424242424FORLIGHT0% MAINTENANCE0% COMPLETE0%0% EXISTING0%0%0%0%0%COSTS0%000000015,809.00- FOR10,808.003,247.005,365Total Initial Cost of eachT.ReplacedCOSTLightOF -141,775204948760Total hours Usage/year in (hrs)Consumption per Year/1 Luminaire (kw/hr)Consumption per Year/CompleteLuminaires (kw/hr)Maintenance Cost/year 06223,5476,3512,581705152534,4031,524339166,312 67,913 109,354 50,319SARSARSARSARSARSAR 0 INSAR50 YEARSSAR 0 WARRANTYSAR 0 22,095(ROI) RETURNOF0 INVESTMENT4,1852,5201,305T. Cost/year Consumption per yearCost Maintenance Cost R705SAR3,346SAR1,524138SAR 0SAR29,425SAR 0SARSARSARSAR188,407 67,913 138,779 50,319SAVINGPAY BACK PERIOD (YEARS)Installation Cost forReplaced ItemsT. of Initial Cost Investment for theReplaced LED Items InstallationSAR 450,579.00T. Cost of Consumption for completeExisting Lights Maintenance CostSAR 386,044T. Cost of Consumption forComplete Replaced LED ItemsSAR 137,876Saving/ Year (SAR)8SAR 110,000.00SAR 248, 168.41ROI (Return of Investmentin 5years Warranty175%Pay Back Period (Years)1.82alroufled.com

LIST OF CLIENTSINDUSTRIAL SEGMENTSalroufled.com9

LIST OF CLIENTSRETAIL:Gasoline Stations:ContractingP SCConstructionProjects SpecialistsContracting Co.LtdIsam K. KabbaniGroup of CompaniesHospitality:10alroufled.com

LUMINAIRESINDUSTRIAL LIGHTS

INDUSTRIAL LIGHTHighbay Series are designed for retail, hospitality, industriallighting adopting the newest LED lightingTechnology with higher lm/w light Efficiency.AREA OF APPLICATIONSupermarket , Factories, Warehouse, High room, Exhibition Hall.ALROUF HIGHBAY LIGHT12Nominal Wattage100W to 300WAvailable Wattages100W, 150W, 200W, 230W, 300WInput VoltageAC200-240V / AC100-240V / AC100-277V / AC200-480V 50/60HzOperating Temperature-40 C to 50 CLuminaire Efficacy130lm/WBeam Angle60 /90 /120 CRI RatingRA70/RA80CCT3000KIP RatingIP65IK RatingIK08MaterialDie-cast Aluminum, Tempered GlassFinishBlack (RAL9005), other RAL available upon requestLumen MaintenanceL70 @ 75,000hrs, 25 CLife Span50,000hrsSource of LEDNichia, Philips Lumileds or EquivalentDriver BrandMeanwell, Inventronics or EquivalentDimming0(1)-10V, PWMSafety FeaturesOver temperature protection, Over voltage protection, Over currentprotection, Ground protection against electric shockCertificationCE, RoHS, TUV, DLC, SASO4000K5000K5700K6500Kalroufled.com

INDUSTRIAL LIGHTHighly durable and robust Linear light designed for harshconditions have to be countered.AREA OF APPLICATIONParking Facilities, Corridors and Hallways, Warehouses,Storage Rooms, Factories and Production AreasALROUF LINEAR LIGHTalroufled.comNominal Wattage40W to 60WAvailable Wattages40W, 60WInput Voltage100-277 VAC, 47-63HzOperating Temperature-30 C to 50 CLuminaire Efficacy135lm/W, 5Beam Angle120 CRI Rating RA80CCT3000KIP RatingIP69K, IP65IK RatingIK10MaterialPolycarbonate, AluminumFinishWhiteLumen MaintenanceL70 100,000hrsLife Span5 yearsSource of LEDNichia, Philips Lumileds or EquivalentDriver BrandMeanwell, Inventronics or EquivalentDimming1-10V, DALISafety FeaturesOpen cirucuit protection, Short circuit Protection, Overvoltage protectionCertificationENEC, TUV, CE, RoHs, CB, UL, cUL, DLC Premium, SAA, RCM, SASO4000K5000K6000K13

INDUSTRIAL LIGHTAn Industrial grade Flood Light has an innovation design anddifferent optics for the best performance in the lightingdistribution.AREA OF APPLICATIONFreight yards, Board illumination, Ports and airports,Landscape lightingALROUF FLOOD LIGHT14Nominal Wattage30W to 200WAvailable Wattages30W, 60W, 80W, 100W, 150W, 180W, 200WInput VoltageAC200-240V / AC100-277V / AC200-480V 50-60HzOperating Temperature-35 C to 55 CLuminaire Efficacy130lm/WBeam Angle30 / 60 / 90 / 65 x120 / 75 x135 CRI Rating RA70CCT2700K to 6500KIP RatingIP65IK RatingIK08MaterialAluminumFinishBlack, GrayLumen MaintenanceL70 @ 75,000hrs at 25 CLife Span50,000hrsSource of LEDNichia, Philips Lumileds or EquivalentDriver BrandMeanwell, Inventronics or EquivalentDimmingNoneSafety FeaturesOvervoltage, overcurrent & over temperature protection, 4KV surge protectionCertificationUL, DLC, TUV, CE, ROHS, ISO9001, ISO140001, LM80, SASOalroufled.com

INDUSTRIAL LIGHTALROUF FLOOD LIGHTalroufled.comNominal Wattage150W to 200WAvailable Wattages150W, 200WInput VoltageAC100-277V, 47-63HzOperating Temperature-30 C to 50 CLuminaire Efficacy150lm/W, 10Beam Angle30 , 60 , 90 , 130 , 90 x120 , 40 x130 , TYPE 2, TYPE 3, TYPE 4CRI Rating RA70CCT3000KIP RatingIP67IK RatingIK10MaterialDie-cast aluminum, GlassFinishWhiteLumen Maintenance70%Life Span5 yearsSource of LEDNichia, Philips Lumileds or EquivalentDriver BrandMeanwell, Inventronics or EquivalentDimming1-10V, DALISafety FeaturesOpen circuit protection, Short circuit Protection, Overvoltage protectionCertificationTUV, CE, RoHs, SASO4000K5000K6000K15

INDUSTRIAL LIGHTALROUF SOLAR STREET LIGHT16Nominal Wattage40W to 80WAvailable Wattages40W, 60W, 80WOperating Temperature-20 C to 70 CSolar Panel50W, 70W and 100W monocrystalline solar panelBattery12.8V 24Ah LiFePO4 (Lithium Iron Battery)Power Output4 hours 100% max. power, 4 hours 60%, 4 hours 30%Discharge Time10-12 hrsLuminaire Efficacy120-130lm/WBeam Angle140 horizontal direction, 70 vertical directionCRI RatingRA80CCT3000K to 6500KIP RatingIP65MaterialAluminumFinishBlackLife Span50,000hrsSource of LEDNichia, Philips Lumileds or EquivalentDimmingPIR motion sensorSafety FeaturesAcoording to EN 60598-1 standards, SASOalroufled.com

INDUSTRIAL LIGHTALROUF SOLAR STREET LIGHTalroufled.comNominal Wattage40W to 60WAvailable Wattages40W, 60WOperating Temperature-20 C to 70 CSolar Panel80W and 120W solar panelBattery12.8V 24Ah LiFePO4 (Lithium Iron Battery)Power Output4 hours 100% max. power, 4 hours 60%, 4 hours 30%Discharge Time12 hrsLuminaire Efficacy120lm/WBeam Angle140 horizontal direction, 70 vertical directionCRI RatingRA80CCT6000K to 6500KIP RatingIP66MaterialAluminumFinishBlackLife Span50,000hrsSource of LEDNichia, Philips Lumileds or EquivalentDimmingnoneSafety FeaturesAcoording to EN 60598-1 standards, SASO17

INDUSTRIAL LIGHTALROUF STREET LIGHT18Nominal Wattage40W to 260WAvailable Wattages40W, 80W, 100W,150W,200W,260WInput VoltageAC85-265VOperating Temperature-35 C to 55 CLuminaire Efficacy120lm/WBeam Angle150 ,75 CRI Rating RA70CCT2700K to 6500KIP RatingIP66IK RatingIK09MaterialADC12 aviation die-casting aluminumFinishGray RAL 7037Lumen MaintenanceL70 72000hrsLife Span50,000hrsSource of LEDNichia, Philips Lumileds or EquivalentDriver BrandMeanwell, Inventronics or EquivalentDimmingNone by default but optional upon requestSafety FeaturesSurge protection, Short circuit protectionCertificationCE, RoHS, SASOalroufled.com

INDUSTRIAL LIGHTALROUF STREET LIGHTalroufled.comNominal Wattage50W to 200WAvailable Wattages50W, 100W,150W,200WInput Voltage100-277 VAC (347/480 VAC Optional)Operating Temperature-30 C to 55 CLuminaire Efficacy135lm/WBeam Angle100 x150 , 80 x135 , 80 x150 CRI Rating RA70CCT2700K to 6500KIP RatingIP66IK RatingIK10MaterialAluminum AlloyFinishGrayLumen MaintenanceL70 100,000hrsLife Span50,000hrsSource of LEDNichia, Philips Lumileds or EquivalentDriver BrandMeanwell, Inventronics or EquivalentDimmingOptionalSafety Featuresas per CB, CE certificationCertificationCB, CE, RoHS, SASO19

OBSTRUCTION LIGHTObstruction light generally be used on any tall structuresuch as Flares, tower crane, chimneys, electricity pylons, tallbuildings and wind turbinesAll products are certified by FAA and ICAO regulation.LOW INTENSITYWattage: Single & Dual Units DC - 1.5W; Single & Dual Units AC - 6.5WOperating Voltage:120 - 240V AC; 277V AC; 12 - 48V DCEffective Intensity:32 cd (FAA, TC & ICAO); 100 cd (CASA)Ratings IP66MEDIUM INTENSITYWattage: 10W (FAA L-864 infrared)Operating Voltage: 48VDC (-10%; 15%)Effective light output: night mode at 0 on site 2000cd (red)Flash per minute: 20, 30, 40 or 60 flashes per minute or fixed(ICAO medium intensity type C), 30fl per minute for L-864HIGH INTENSITYWattage: 120W (FAA L-864 infrared)Operating Voltage: 48VDC (-10%; 15%)Effective light output: night mode at 0 on site 2000cd (red)Effective light output : day time at 0 on site 100000cd (white)Effective light output : twilight mode at 0 on site20000cd (white)Flash per minute: 6020alroufled.com

EXPLOSION PROOF LIGHTSALROUF HIGHBAY/LOWBAY LIGHTNominal Wattage20W to 200WAvailable Wattages20W, 40W, 60W, 80W, 100W, 120W, 150W, 200WInput VoltageAC100-277V / AC200-480V / DC12-36VOperating Temperature-40 C to 50 CLuminaire Efficacy140lm/WBeam Angle60 /90 /120 /140 CRI RatingRA80CCT2700K to 7000KIP RatingIP66IK RatingIK10MaterialCopper Free Aluminum, Tempered GlassFinishGrayLumen MaintenanceL70 @ 50,000hrsLife Span50,000hrsSource of LEDNichia, Philips Lumileds or EquivalentDriver BrandMeanwell, Inventronics or EquivalentDimmingDimmable function availableSafety Features10Kv surge protectionMarking AtexII3 G Ex ec IIB T3 Gc, II2 D Ex op is tb IIIC T120 C/135 C DbMarking IECEXEX ec IIB T3C Gc, Ex op is tb IIIC T120 C/135 C DbMarking UL844Class I, Division 2, Groups A, B, C, DClass II, Division 1, Groups E, F, GClass II, Division 2, Groups F, GClass IIIMarine MarkingUL 1598A, ABS Type ApprovedCertificationSASOalroufled.com21

EXPLOSION PROOF LIGHTSALROUF HIGHBAY LIGHTNominal Wattage20W to 80WAvailable Wattages20W, 40W, 60W, 80WInput VoltageAC100-277V / AC200-480V / DC12-36VOperating Temperature-40 C to 50 CLuminaire Efficacy140lm/WBeam Angle40 /60 /90 /120 CRI RatingRA70CCT2700K to 7000KIP RatingIP66IK RatingIK10MaterialDie-cast Aluminum, Tempered GlassFinishGrayLumen MaintenanceL70 @ 50,000hrsLife Span50,000hrsSource of LEDNichia, Philips Lumileds or EquivalentDriver BrandMeanwell, Inventronics or EquivalentDimmingDimmable function availableSafety Features10Kv surge protectionMarking AtexII2 G Ex db op is IIB T4/T5 Gb, II2 D Ex op is tb IIIC T135 C Db IP66Marking IECEXEx db op is IIB T4/T5 Gb, Ex op is tb IIIC T135 C Db IP66Marking UL844Class I, Division 1, Groups C, DClass I, Division 2, Groups A, B, C, DClass II, Division 1, Groups E, F, GClass II, Division 2, Groups F, GClass III22Marine MarkingUL 1598A, ABS and DNV Type ApprovedCertificationSASOalroufled.com

EXPLOSION PROOF LIGHTSALROUF FLOOD LIGHTNominal Wattage20W to 200WAvailable Wattages20W, 40W, 60W, 80W, 100W, 120W, 150W, 200WInput VoltageAC100-277V / AC200-480V / DC12-36VOperating Temperature-40 C to 50 CLuminaire Efficacy140lm/WBeam Angle60 /90 /120 CRI RatingRA70CCT2700K to 7000KIP RatingIP66IK RatingIK10MaterialDie-cast Aluminum, Tempered GlassFinishGrayLumen MaintenanceL70 @ 50,000hrsLife Span50,000hrsSource of LEDNichia, Philips Lumileds or EquivalentDriver BrandMeanwell, Inventronics or EquivalentDimmingDimmable function availableSafety Features10Kv surge protectionMarking AtexII3 G Ex nR IIC T5/T6 Gc, II2 D Ex op is tb IIIC T95 C/T80 C Db IP66Marking IECEXEx nR IIC T5/T6 Gc, Ex op is tb IIIC T95 C/T80 C Db IP66Marking UL844Class I, Division 2, Groups A, B, C, DClass II, Division 1, Groups E, F, GClass II, Division 2, Groups F, GClass IIIMarine MarkingUL 1598A, ABS and DNV Type ApprovedCertificationSASOalroufled.com23

EXPLOSION PROOF LIGHTSALROUF FLOOD LIGHTNominal Wattage20W to 220WAvailable Wattages20W, 40W, 60W, 80W, 100W, 150W, 220WInput VoltageAC100-277V / AC200-480VOperating Temperature-40 C to 50 CLuminaire Efficacy130lm/WBeam Angle60 /90 /120 CRI RatingRA70CCT4000K to 5700KIP RatingIP66IK RatingIK10MaterialCopper Free Aluminum, Tempered GlassFinishGrayLumen MaintenanceL70 @ 50,000hrsLife Span50,000hrsSource of LEDNichia, Philips Lumileds or EquivalentDriver BrandMeanwell, Inventronics or EquivalentDimmingDimmable function availableSafety Features10Kv surge protectionMarking AtexII2 G Ex db IIC T6 Gb, II2 D Ex tb is tb IIIC T80 C Db IP66Marking IECEXEx db IIC T6 Gb, Ex tb IIIC T80 C Db IP66Marking UL844Class I, Division 1, Groups C, DClass I, Division 2, Groups A, B, C, DClass II, Division 1, Groups E, F, GClass II, Division 2, Groups F, GClass III24Marine MarkingUL 1598A, ABS and DNV Type ApprovedCertificationSASOalroufled.com

EXPLOSION PROOF LIGHTSALROUF LINEAR LIGHTNominal Wattage10W to 60WAvailable Wattages10W, 20W, 30W, 40W, 50W, 60WInput VoltageAC100-277V / AC200-480V / DC12-36VOperating Temperature-40 C to 50 CLuminaire Efficacy140lm/WBeam Angle120 CRI RatingRA70CCT2700K to 7000KIP RatingIP66IK RatingIK10MaterialDie-cast Aluminum, PolycarbonateFinishGrayLumen MaintenanceL70 @ 50,000hrsLife Span50,000hrsSource of LEDNichia, Philips Lumileds or EquivalentDriver BrandMeanwell, Inventronics or EquivalentDimmingDimmable function availableSafety Features10Kv surge protectionMarking AtexII3 G Ex nR IIC T5/T6 Gc, II2 D Ex op is tb IIIC T95 C/T80 C Db IP66Marking IECEXEx nR IIC T5/T6 Gc, Ex op is tb IIIC T95 C/T80 C Db IP66Marking UL844Class I, Division 2, Groups A, B, C, DClass II, Division 1, Groups E, F, GClass II, Division 2, Groups F, GClass IIIMarine MarkingUL 1598A, ABS and DNV Type ApprovedCertificationSASOalroufled.com25

EXPLOSION PROOF LIGHTSALROUF LINEAR LIGHT HIGHBAYNominal Wattage20W to 120WAvailable Wattages20W, 30W, 60W, 80W, 90W, 100W, 110W, 120WInput VoltageAC100-277V / AC200-480V / DC12-36VOperating Temperature-40 C to 50 CLuminaire Efficacy140lm/WBeam Angle40 /60 /90 /120 CRI RatingRA70CCT4000K to 5700KIP RatingIP66IK RatingIK10MaterialCopper free Aluminum, PolycarbonateFinishGrayLumen MaintenanceL70 @ 50,000hrsLife Span50,000hrsSource of LEDNichia, Philips Lumileds or EquivalentDriver BrandMeanwell, Inventronics or EquivalentDimmingDimmable function availableSafety Features10Kv surge protectionMarking AtexII2 G Ex db IIB T4 Gb, II2 D Ex tb IIIC T63.5 C Db IP65Marking IECEXEx db IIB T4 Gb, Ex tb IIIC T63.5 C Db IP65Marking UL844Class I, Division 1, Groups C, DClass I, Division 2, Groups A, B, C, DClass II, Division 1, Groups E, F, GClass II, Division 2, Groups F, GClass III26Marine MarkingUL 1598A, ABS and DNV Type ApprovedCertificationSASOalroufled.com

EXPLOSION PROOF LIGHTSALROUF EXIT LIGHTNominal WattageAvailable WattagesInput VoltageOperating TemperatureMaterialEmergency TimeSafety FeaturesMarking UL844Certification3W to 11W3W, 7W, 11WAC100-277V 50/60 Hz10 C to 55 CCopper free Aluminum Alloy3hrsSelf Testing MicroprocessorClass I, Division 2, Groups A, B, C, DSASOALROUF EXIT LIGHTNominal WattageAvailable WattagesInput VoltageOperating TemperatureColor TemperatureIP RatingMaterialSafety FeaturesMarking UL844Marking AtexMarking IECEXCertification1W to 3W1W, 2W, 3WAC100-277V, DC12-36V10 C to 55 C2700 to 7000KIP66Glass fiber reinforced polyester10 Kv surge proctectionClass I, Division 2, Groups A, B, C, DII2 G Ex eb ib op is q IIC T4/T5 Gb, II2 D Ex op is tb IIIC T135 C/100 C Db IP66Ex eb ib op is q IIC T4/T5 Gb, Ex op is tb IIIC T135 C/100 C Db IP66SASOALROUF EXIT LIGHTNominal WattageAvailable WattagesInput VoltageOperating TemperatureIP RatingMaterialSafety FeaturesMarking UL844Certification3W to10W3W, 5W, 8W, 10WAC100-277V, DC12-48V10 C to 55 CIP66A360 Die-casting aluminum, resistant acrylic10 Kv surge proctectionClass I, Division 1, Groups C, DClass I, Division 2, Groups A, B, C, DClass II, Division 1, Groups E, F, GClass II, Division 2, Groups F, GClass IIISASOALROUF LED TORCHPower RatingInput VoltageOperating TemperatureStrong/Normal Light Luminous FluxLED Average Service LifeStrong/Normal Light DurationBattery Charging HoursBattery Recyclable Charging TimesIP RatingMaterialMarking AtexCertificationalroufled.com3W3.7V10 C to 55 C 390lm/ 130lm100,000hrs4hrs/8hrs 6hrsApprox. 1000 timesIP67AluminumEx d II Ct6SASO27

LUMINAIRESINDOORS

INDOOR LIGHTSALROUF PANEL LIGHTalroufled.comNominal Wattage40WAvailable Wattages40WInput Voltage100-240VAC 50/60HzOperating Temperature-20 C to 50 CSizes595x595, 600x600, 295x1195, 300x1200Lumen Output3260lm 5 (WW), 3750lm 5 (NW), 4040lm 5 (CW)Beam Angle120 CRI Rating RA80CCT3000K(WW), 4000K(NW), 6500K(CW)IP RatingIP20MaterialPolycarbonate, Aluminum, SteelFinishWhiteLife Span50,000hrsSource of LEDNichia, Philips Lumileds or EquivalentDriver BrandMeanwell, Inventronics or EquivalentDimmingnoneSafety Featuresas per CB certificationCertificationCB, SASO29

INDOOR LIGHTSALROUF BASIC DOWNLIGHTSNominal Wattage12W to 35WAvailable Wattages12W,15W,20W,25W,30W,35WInput VoltageAC220-240VOperating Temperature-20 C to 40 CLuminaire Efficacy100lm/WBeam Angle90 CRI Rating RA80CCT3000K, 4000K, 6000KIP RatingIP20MaterialAluminumFinishSandy Black, WhiteLife Span50,000hrsSource of LEDNichia, Philips Lumileds or EquivalentDriver BrandMeanwell, Inventronics or EquivalentDimmingTRIAC, 1-10V, DALISafety Featuresas per CE-EMC, CE-LVD certificationCertificationCE, SASOALROUF DOWNLIGHTS WITH COLORED REFLECTORS30Nominal Wattage6W to 25WAvailable Wattages6W,8W,12W,15W,20W,25WInput VoltageAC220-240VOperating Temperature-20 C to 40 CLuminaire Efficacy100lm/WBeam Angle30 CRI RatingRA90CCT2700K, 3000K, 3500K, 4000KIP RatingIP20MaterialAluminumFinishSandy Black, WhiteLife Span50,000hrsSource of LEDNichia, Philips Lumileds or EquivalentDriver BrandMeanwell, Inventronics or EquivalentDimmingTRIACSafety Featuresas per CE-EMC, CE-LVD certificationCertificationCE, SASOalroufled.com

INDOOR LIGHTSALROUF LED TUBE LIGHTSalroufled.comNominal Wattage9W to 24WAvailable Wattages9W, 14W, 18W, 24WInput Voltage100-240VAC 50/60HzOperating Temperature-20 C to 50 CSizes600, 900, 1200, 1500luminous Efficacy 105 Im/WBeam Angle180 CRI Rating RA80CCT3000K(WW), 4000K(NW), 6500K(CW)IP RatingIP20MaterialPolycarbonate, AluminumFinishWhiteLife Span50,000hrsSource of LEDNichia, Philips Lumileds or EquivalentDimmingnoneSafety Featuresas per CB certificationCertificationCB, SASO31

INDOOR LIGHTSALROUF EXIT LIGHTWattage1.2WInput Voltage120-277VAC 50/60HzBatteryBuilt-in 1.2/1200mAh NiMH batteryMaterialABS, UL-94V-0 flame rating, fire resistantMountingWall suface mounting, Ceiling mounting Side wall mountingComplianceSS IEC 60598-2-22, SS 563, SASOALROUF EXIT LIGHTWattage3WInput Voltage220-240VAC 50/60HzBatteryHigh Temperature Nickel CadmiumChargerRegulated Variable RateMaterialAcrylic plate (fire retardant)Rated Duration3hrsLife Span50,000hrsMountingSuface wall, Suspended, Surface CeilingSafety FeaturesLow battery voltage cutoffComplianceSS IEC 60598-2-22, SS 563, SASOALROUF EXIT LIGHTWattage3WInput Voltage220-240VAC 50/60HzBatteryHigh Temperature Nickel CadmiumChargerRegulated Variable RateMaterialAcrylic plate (fire retardant)Rated Duration3hrsLife Span50,000hrsMountingRecessed CeilingSafety FeaturesLow battery voltage cutoffComplianceSS IEC 60598-2-22, SS 563, SASOALROUF EXIT LIGHT32Wattage3WInput Voltage220-240VAC 50/60HzBatteryHigh Temperature Nickel CadmiumChargerRegulated Variable RateMaterialAcrylic plate (fire retardant)Rated Duration3hrsLife Span50,000hrsMountingSufrace wall, Semi-recessed wallSafety FeaturesLow battery voltage cutoffComplianceSS IEC 60598-2-22, SS 563, SASOalroufled.com

INDOOR LIGHTSALROUF EXIT LIGHTWattage3WInput Voltage220-240VAC 50/60HzBatteryHigh Temperature Nickel CadmiumChargerRegulated Variable RateMaterialAcrylic plate (fire retardant)Rated Duration3hrsLife Span50,000hrsMountingSuspended, Surface ceiling, Surface wallSafety FeaturesLow battery voltage cutoffComplianceSS IEC 60598-2-22, SS 563, SASOALROUF EXIT LIGHTWattage3WInput Voltage220-240VAC 50/60HzBatteryHigh Temperature Nickel CadmiumChargerRegulated Variable RateMaterialAcrylic plate (fire retardant)Rated Duration3hrsLife Span50,000hrsMountingRecessed wall mountSafety FeaturesLow battery voltage cutoffComplianceSS IEC 60598-2-22, SS 563, SASOALROUF CUSTOMIZED SIGNAGE LIGHTWattage3WInput Voltage220-240VAC 50/60HzBatteryHigh Temperature Nickel CadmiumChargerRegulated Variable RateMaterialAcrylic plate (fire retardant)Life Span50,000hrsMountingSurface mount (Recessed mount option available)alroufled.com33

INDOOR LIGHTSALROUF EMERGENCY LIGHTWattage1.5WInput Voltage220-240VAC 50/60HzBatteryHigh Temperature Nickel CadmiumChargerRegulated Variable RateMaterialAcrylic plate (fire retardant)Rated Duration3hrsMountingRecessed ceilingSafety FeaturesLow battery voltage cutoffComplianceSS IEC 60598-2-22, SS 563, IEC 61347-2-7, IEC 61347-2-13, SASOALROUF EMERGENCY LIGHTWattage1.5WInput Voltage220-240VAC 50/60HzBatteryHigh Temperature Nickel CadmiumChargerRegulated Variable RateMaterialAcrylic plate (fire retardant)Rated Duration3hrsMountingSurface mountSafety FeaturesLow battery voltage cutoffComplianceSS IEC 60598-2-22, SS 563, IEC 61347-2-7, IEC 61347-2-13,SASOALROUF EMERGENCY LIGHTWattage1.5WInput Voltage220-240VAC 50/60HzBatteryHigh Temperature Nickel CadmiumChargerRegulated Variable RateMaterialAcrylic plate (fire retardant)Rated Duration3hrsMountingRecessed ceilingSafety FeaturesLow battery voltage cutoffComplianceSS IEC 60598-2-22, SS 563, SASOALROUF EMERGENCY LIGHT34Wattage12.5WInput Voltage220-240VAC 50/60HzBatteryHigh Temperature Nickel CadmiumChargerRegulated Variable RateMaterialAcrylic plate (fire retardant)Rated Duration2hrsMountingRecessed ceilingSafety FeaturesLow battery voltage cutoffComplianceSS IEC 60598-2-22, SS 563, SASOalroufled.com

INDOOR LIGHTSALROUF EMERGENCY LIGHTWattage3WInput Voltage220-240VAC 50/60HzBatteryHigh Temperature Nickel CadmiumChargerRegulated Variable RateMaterialAcrylic plate (fire retardant)Rated Duration2hrsMountingSurface ceilingSafety FeaturesLow battery voltage cutoffComplianceSS IEC 60598-2-22, SS 563, SASOALROUF EMERGENCY LIGHTWattage1.5WInput Voltage220-240VAC 50/60HzBatteryHigh Temperature Nickel CadmiumChargerRegulated Variable RateMaterialAcrylic plate (fire retardant)Rated Duration2hrs (3hrs on request)MountingSurface mountedSafety FeaturesLow battery voltage cutoffComplianceSS IEC 60598-2-22, SS 563, SASOALROUF WEATHERPROOF EMERGENCY LIGHTWattage1.5WInput Voltage220-240VAC 50/60HzBatteryHigh Temperature Nickel CadmiumChargerRegulated Variable RateMaterialAcrylic plate (fire retardant)Rated Duration2hrsMountingSurface mountedSafety FeaturesLow battery voltage cutoffComplianceSS IEC 60598-2-22, SS 563, SASOalroufled.com35

INDOOR LIGHTSALROUF CONVERSION KITPower Consumption 2WInput Voltage220-240VAC 50/60HzLamp Type3-70V LED loadSupply Current20mATrickle Charge80mA/125mABattery ChargerRegulated variable rateBattery ProtectionLow battery voltage cut offBatteryHigh Temperature Nickel CadmiumMaterialElectro-galvanised steelMax. Casing Temp, Tc70 CMax. Ambient Temp, Ta50 CRated Duration2hrs/3hrsMountingSurface mountedSafety FeaturesLow battery voltage cutoffComplianceIEC 61347-2-7 (SS 490-2-7), SS 563, IEC 61347-2-13, IEC 62384, SASOALROUF BATTERY PACK36LED Luminaire Power RangeIndoor LED Light 0-30W, 0-60WMax. LED Driver Current Connected2000mAInput Voltage100-277VAC 50/60HzOutput Emergency Power

Luminaires Industrial Lights Obstruction Light Luminaires Indoor Lights Luminaires Gas Station Lights . Nichia, Philips Lumileds or Equivalent Meanwell, Inventronics or Equivalent 0(1)-10V, PWM . Email web AL ROUF