The Path To More Efficient Lighting - Philips

Transcription

§The path to more efficient lighting

High pressure sodium lampsWhich lamp is the ideal replacement?Standardlamp70 Watt100 Watt150 Watt250 Watt400 WattMASTERSONPIA Plus 70 Watt 100 Watt 150 Watt 250 Watt 400 15871150019344515871150019345215Standardhigh pressure sodium ovoideStandardlamp50 Watt70 Watt100 Watt150 WattStandardlamp70 Watt100 Watt150 Watt250 Watt400 WattMASTERCityWhiteCDO-ET 50 Watt 70 Watt 100 Watt 150 WattMASTERSON-TPIA Plus 70 Watt 100 Watt 150 Watt 250 Watt 400 871150019229515871150017987615871150017988315- 1-1 lamp replacement,from yellow to yellowlight- high reliability- improved service lifetimefrom 12000 hrs to 16000hrs (4 years)- 1-1 lamp replacement,from yellow to whitelight- hight qualitative whitelightThe implementing measure for office, industry andstreet lighting (tertiary) laid down new requirementsregarding minimum efficiency in sodium vapour lamps.Inefficient sodium vapour lamps will therefore bediscontinued as of April 2012.1-1lamplampreplacement,replacement,- ghtreliabilityqualitative white- -highlight- improvedservice lifetimefrom 12000 hrs to 16000hrs (4 years)Timeplan for the phasing outStandardhigh pressure sodium tubular2010Standardlamp50 Watt70 Watt100 Watt150 Watt250 WattMASTERCityWhiteCDO-TT 50 Watt 70 Watt 100 Watt 150 Watt 250 15871150020536015871150020905415- 1-1 lamp replacement,from yellow to whitelight- hight qualitative whitelightEuP-Legislation 200920152017Metal Halidepermitteddiscontinuation of all inefficient metal halide lampsall inefficient typesPermittedDiscontinuation22012High pressure mercurypermitted discontinuation of allhigh pressure mercury lampsHigh pressure sodiumpermitteddiscontinuation of unefficienthigh pressure sodium replacementsNote: All wattages are approximate. The decisive factor is the luminous flux (lumen)Lamps may no longer be put on the market. All stocks may be used up.

High pressure mercury lampsWhich energy saving lamp is the ideal replacement?New approaches are particularly in demand in times offinancial and energy crises. The mercury vapour lampUp towill soon be obsolete, as it will lose the CE symbol from20%***2015. So municipalities should already be rethinkingEnergysavingand including new lighting solutions in future budgetplanning. Modern lighting concepts make the entiretownscape more attractive. Both residents and visitorsbenefit from this.Highpressuremercury80 Watt**125 Watt**250 Watt**400 Watt**SON-HEOC . 68 Watt** 110 Watt** 220 Watt** 350 5871150018213515- from white to yellowlight- lower running costs- 1-1 lamp replacementHigh pressuremercury lampePhilips offers a wide spectrum of low-maintenance,high-quality outdoor luminaires that are state of theart. Here we give just a selection of the availableproducts. Please consult the latest catalogue or theInternet for other outdoor luminaires.Up to42%*EnergysavingHigh pressuremercury80 Watt**125 Watt**250 Watt**MASTERCityWhite CDO-ET 70 Watt CDO-ET 70 Watt CDO-ET 150 Watt- lamp and gear to build inexisting luminaire- high qualitative whitelightExisting luminaires*Energy consumption with similar luminous flux and number of lighting hours.** These lamps will lose the CE symbol in 2015.*** Energy consumption of an energy-saving lamp compared to a mercury vapour lamp.EuP-Legislation 20093

High pressure mercury lampsWhich energy saving system is the ideal replacement?Up to79%*EnergysavingHigh pressuremercury50/80 Watt**125 Watt**2x 50/80 Watt**250 Watt**400 Watt**MASTERCosmoWhite CPO-TW 45 Watt CPO-TW 160 Watt CPO-TW 45/60 Watt CPO-TW 60/90 Watt CPO-TW 90/140 Watt- high qualitative white light- more light- service lifetime up to16000 hrs (4 years)- dimming down to 60% ofnominal powerGreen FlagshipA “Green Flagship” product is better in at least one ofthe key areas than rival products, its predecessor or adifferent product type in the same application. In allother key areas it is at least as good.High pressuremercury lampHigh pressuremercuryUp to65%*Energysaving80 Watt**125 Watt**250 Watt**MASTERCityWhite CDO-TT2 CDO-TT 50/70 Watt CDO-TT 70 Watt CDO-TT 150 Watt- high qualitative white light- more light- service lifetime up to12000 hrs (3 years)- dimming down to 60% ofnominal powerKey areas:Efficient use of energyHazardous materialsPackagingReliability over course of service lifeNew luminaireHigh pressuremercuryUp to75%*Energysaving80 Watt**125 Watt**250 Watt**High pressuremercuryUp to70%*Here we give just a selection of the available products.Please consult the latestcatalogue or the Internetfor other products or theirtechnical characteristics anddimensions.4EuP-Legislation 2009Energysaving50 Watt80 Watt125 Watt125 Watt* Energy consumption with similar luminous flux and number of lighting hours.** These lamps will lose the CE symbol in 2015.*** Power consumption depends on colour temperature.MASTERSON-T Plus SON-T Plus 50 Watt SON-T Plus 50/70 Watt SON-T Plus 100/150 WattFortimo LED LLM*** 1000 lm / 16 - 17 Watt 1300 lm / 25 - 28 Watt 3000 lm / 35 - 40 Watt 4500 lm / 56 - 60 Watt- from white to yellow light- more light- service lifetime up to16000 hrs (4 years)- dimming down to 30% ofnominal power- high qualitative white light- more light- service lifetime up to50000 hrs- dimming down to 0% ofnominal powerRecyclabilityWeight

Fluorescent lampsWhich fluorescent lamp is the ideal replacement?Up to10%*EnergysavingTL-D StandardlampsLight colour 33-640Up toThe implementing measure for office, industry andFrom 13.04.2010street lighting (tertiary) laid down new requirementsregarding minimum efficiency and colour rendering influorescent lamps. Inefficient TL-D standard lamps inlight colours 33-640 and 54-765 will thus be discontinued as of April 2010 and must be replaced by Super80 light colours.Discontinuation of alllight colours33-540 and 54-765via minimum efficiency(Im/W) and colourrendering (RA 80)10%*EnergysavingUp to50%*EnergysavingTL-DLamp33-64018 Watt36 Watt58 WattTL-DLamp33-64018 Watt30 Watt36 Watt58 WattTL-DLamp33-64018 Watt36 Watt58 WattTL-DLamp33-64018 Watt36 Watt58 WattTL-DLamp33-640For even higher energy efficiency, consider switching from TL-D luminaires to luminaires with TL-5 lamps inside and controls.18 Watt36 Watt58 WattMASTER TL-DEco 840EOC8711500. 16 Watt 32 Watt 51 Watt.26861740.26462640.26470140MASTER TL-DSuper 80 840EOC8711500. 18 Watt 30 Watt 36 Watt 58 Watt.63171840.63186240.63201240.63219740MASTER TL-DReflex 840 18 Watt 36 Watt 58 WattMASTER TL-DXtra 840 18 Watt 36 Watt 58 WattMASTER TL-DXtreme 840 18 Watt 36 Watt 58 868840.55886240- higher light output- better colour rendering(Ra 85)- 75% less mercurycontent- longer lifetime- higher light output- better colour rendering(Ra 85)- 75% less mercury content- longer lifetime- 85% of the light isdirected down- replaces 2 TL-D standardlamps in luminaireswithout a reflector- better colour rendering(Ra 85)- 38% less mercury content- longer lifetime- higher light output- better colour rendering(Ra 85)- extra long lifetime of55000 hrs on electroniccontrol gear- higher light output- better colour rendering(Ra 85)- extreme long lifetime of79000 hrs on electroniccontrol gearEuP-Legislation 20095

Standby losses for dimmable DALI gearWhich energy efficient gear is the ideal replacementA light fixture using dimmable electronic gear isconsidered most efficient in today’s EEI classificationUp to65%*and contains the A1 class label. Leglistation for theseStandby losssavingtypes of gear becomes more stringent on standbylosses. Dimmable electronic gears containing a DigitalDimmable gear withstandby loss 1 WattHF-R TD E11- HF-R TD TL-5 EII range HF-R TD PLL EII range HF-R TD TL-D EII range HF-R TD PL-T/C/R EII rangeDimmable gear withstandby loss 1 WattHF-R intelligent TD- HF-Ri TD 1 28/35/49/54 TL-5 HF-Ri TD 2 28/35/49/54 TL-5 HF-Ri TD 1 35/49/80 TL-5Adressable Lighting Interface (DALI) or Digital SerialInterface (DSI) are mostly not switched off but go instandby mode when an area is vacated. In an averageoffice application the power consumption in standbylasts on average 14 hrs per day and 24 hrs duringthe weekends. This can add up the energy costsconsiderable. Therefor per 2010 these standby lossescan no longer exceed 1 Watt. Per 2012 this is furtherrestricted to max 0,5 Watt per ballast.Already today Philips offers dimmable DALI gear withlowest available standby loss in the market at only350mW for its existing HFR EII range, and only 250mWfor its new HFR Intelligent range.6EuP-Legislation 2009Dimmable electronic gearwith standby loss 1 Wattand future 0,5 Watt (2012)Up to75%*Standby losssaving- only 350 mW standbyloss- 1-100% dimmable range- anti extinguish control- extended cable flexibilitytechnology- full DALI compliant- only 250 mW standbyloss- delivering 5% energysaving VS.HF-R EII bysmart electrode heating- T5 eco compatible- optimized for controlsystems such as Actilume,OccuPlus, full DALIcompliant- lamp on guard

ElectroMagnetic and class A3 electronic gearWhich energy efficient gear is the ideal replacementAlso for ballasts for fluorescent lamps the EUP legislationbecomes more stringent. Since November 2005 Class25%*D and C classed ElectroMagnetic (EM) ballasts areBTA C and B2HF Performer IntelligentBTA 18W C 220V 50HzBTA 36W C 220V 50Hz HFPi 1 14/21/39 TL5 EII 220-240 50/60Hz HFPi 1 14/21/39 TL5 EII 220-240 50/60HzBTA C and B2HF Performer IIIBTA 18W C 220V 50HzBTA 36W C 220V 50Hz HF P III 418 220-240 50/60Hz HF P III 236 220-240 50/60HzUp toBTA C and B2HF Selectalume IIEnergysavingBTA 18W C 220V 50HzBTA 36W C 220V 50Hz HF SII 1 18W 220-240 50/60Hz HF SII 1 36W 220-240 50/60HzEnergysavingalready banned within the EU. Per 2012 every singleluminaire range, equipped with B class EM ballasts- Ability to recogniseand operate multiple lamptypes, TLD, TL5, PLL- 25% Energy saving, A2 class- Compliant withDC emergency lightingnormswhich is offered to the market, published in a catalogor offered in a price lists is to be published or offeredin a class A3 or A2 electronic alternative as well. Thenext stage is the period 2012 -2017 that serves as aD,C and future (2017) B classElectroMagnetic gearUp to25%*Energysavingtransition period for luminaire manufacturers to adjust- One product can runmultiple lamps- Flicker free operation- Silent operation- 25% Energy saving, A2 classand further build towards a complete A2 class electronicluminaire portfolio. By 2017 this transition must becompleted. Per 2017 all light fixtures containing electromagnetic (EM) ballasts and also A3 class electronicballasts will be banned within the EU.Already today Philips offers class A2 and A3 energyefficient alternatives to EM ballasts in a wide range ofelectronic gear as displayed in the overview.20%*- Ability to operate from220 to 240V- 20% energy saving, A3 class- One piece hassle freeinstallation compared withmultiple componentmagnetic systemD, C and future (2017) Bclass electromagnetic gearHere we give just a selectionof the available products.Please consult the latestcatalogue or the Internetfor other products or theirtechnical characteristics anddimensions.* The calculations are based on the energy consumption of a luminairewith LLB and TL-D lamp compared to a luminaire with EB and TL-Dlamp or a luminaire with EB and TL5 lamp technology, with similarluminous flux and age.EuP-Legislation 20097

www.philips.com/oem 2009 Koninklijke Philips Electronics N.V.All rights reserved. Reproduction in whole or in part is prohibited without the prior written consent of the copyright owner. Theinformation presented in this document does not form part of any quotation or contract, is believed to be accurate and reliable and maybe changed without notice. No liability will be accepted by the publisher for any consequence of its use. Publication thereof does notconvey nor imply any license under patent- or other industrial or intellectual property rights.

Philips offers a wide spectrum of low-maintenance, high-quality outdoor luminaires that are state of the art. Here we give just a selection of the available products. Please consult the latest catalogue or the Internet for other outdoor luminaires. Existing luminaires - lamp and gear to b