Explosionproof Rigmaster LED Series Luminaires Linear LED . - Emerson

Transcription

Explosionproof Rigmaster LED Series LuminairesLinear LED fixture for hazardous environmentsNEC/CEC:Class I, Division 1, Groups C and DClass II, Division 1, Groups E, F, GClass IIIClass I Zone 1, Group IIBNEC/CEC:Type 3R, 4, 4X, IP66Simultaneous ExposureSuitable for Use in Wet LocationsNEC/CEC:Marine Outside Type (Salt Water) American Bureau of Shipping (ABS) Certified Applications For use in locations where:— Flammable gases, dusts and ignitable vapors are present— A high degree of corrosion resistance is required— Protection against dirt, water and moisture is necessary— Access to relamp is difficult— Extreme temperature conditions are present Typical applications include:— Drilling rigs— Offshore rigs— Oil refineries— Petrochemical facilities— Foundries— Waste and sewer treatment— Mining and underground tunnels— Power generation— Select paint booth areas Features Low fixture profile allows installation in compact spaces. Two sizes and output options deliver up to 7600 lumens.Fluorescent EquivalentModelNumberNominalLumens ReplacementLamp WattageReplacementLamp TypeReplacementLamp Quantity430032WT82760032WT83 Nominal lumen value for 5000K, clear Lens. detailed lumen informationis provided in data tables Choice of color temperature (CCT): 5000K cool white, 4000Kneutral white or 3000K warm white with minimum 80 CRI. Field replaceable lens, LED driver, battery pack and batterymanagement module (BMM). Two unique mounting bracket options allow for mounting in anylocation and retrofitting third party fixtures. For ease of retrofitting, mounting brackets accommodate mostbolt patterns for Crouse-Hinds , Dialight and othermanufacturers. See compatibility chart below on page 10. Power leads are shipped with wire-nuts as standard. Screw-type terminal block can accept UL/CSA 22-12 AWGwire. Loop in/out wiring capability for interconnecting fixtures. Precision threaded wire cover provides hassle free access towiring department for easy installation and maintenance. Emergency version is suitable for mounting heights up to 15 ftfor 90 minute duration and up to 12 ft for 180 minute duration. Up to 4 casted points for secondary safety retention. Standard 6kV surge protection. Fixture position locking mechanism provides ease andconsistency of aiming. Rugged housing with superior thermal design translates to longluminaire life. Ambient Temperature : -40 C to 65 C (-40 F to 149 F). LED L70 of 60,000 hours reported at 65 C ( 149 F). Photometric data and electronic drawings available uponrequest.Options Brackets can be factory installed or purchased separately. Choice of clear or frosted glass lens Safety cable can be purchased separately or configured as anadd on option to be shipped with the LED fixture Standard ¾” NPT threads with ½” option Emergency battery back up option for 90 or 180 minutes Wirenuts or screw terminal blocks available Standard Materials Housing: copperfree (4/10 of 1% max.) aluminumLens: thermal shock- and impact-resistant glass lensGasket: silicone rubberBolts: Highly corrosion resistant stainless steel (SS 316)Close up plugs: (1) aluminum providedMounting brackets: Zinc plated steelStandard Finishes Housing: gray epoxy powder coat finish, electrostaticallyapplied for complete uniform protectionNEC/CEC Certifications and Compliances UL Standard: UL 50 (13th Edition), UL 50E (2nd Edition), UL 844(13th Edition), UL 1598 (4th Edition), UL 1598A (1st Edition) ,UL 8750 (2nd Edition), UL 924 (10th Edition) CSA Standard: CSA C22.2 No. 94.1-15, CSA 22.2 No 94.2 -15,CSA C22.2 No 137-18, CSA 22.2 No 250.0-18, CSA C22.2 No250.13-17, CSA C22.2 No 60529 -16, CSA C22.2 No 141-15 ANSI Standard: ANSI/IEC 60529 Rigmaster Standard:— UL Certified, File Number: E10794 Rigmaster Emergency— UL Certified, File Number: E175025Related Products Industrial Rigmaster LED Luminaries Hazardous CID2 Rigmaster LED LuminairesDesignLights Consortium Check DLC QPL for current list of products. Applicable to standard (non emergency) fixtures only. Nominal lumen value for 5000K, clear Lens. detailed lumen information is provided in data tables Suitable for use in applications described under NEC 516.6(C)(1) and 516.6(C)(2), 2020 edition. Crouse-Hinds is a registered trademark of Eaton Corporation. Dialight is a registered trademark of Dialight.Visit our website at www.emerson.com or contact us at (800) 621-1506. February 2021233LED/AREA: NEC/CEC, ATEX/IECEx ENCLOSED AND GASKETEDERM*2ERM*4 Ambient Temperature for Emergency Version: -20 C to 55 C(-4 F to 131 F).

Explosionproof Rigmaster LED Series LuminairesLinear LED fixture for hazardous environmentsNEC/CEC:Class I, Division 1, Groups C and DClass II, Division 1, Groups E, F, GClass IIIClass I Zone 1, Group IIBNEC/CEC:Type 3R, 4, 4X, IP66Simultaneous ExposureSuitable for Use in Wet LocationsNEC/CEC:Marine Outside Type (Salt Water) American Bureau of Shipping (ABS) Certified Illustrated FeaturesFlexibility and Ease of UsePrecision threaded wirebox andcover allows hassle free accessto power leads for easy wiringand maintenance in challengingconditions. Cover is securedwith a safety chain to preventaccidental disengagement andenhances workplace safetyNotched position locking mechanismenables multiple fixtures to be aimedconsistently without spending significanttimeRigmaster offers a NPT hub on each end for throughwiring. The power leads are placed inside thewiring compartment and can be easily accessed byremoving the tool-less wire box coverChoose from three color temperatures (CCT): 3000K, 4000K, and 5000KStandard linear light distribution pattern: wide distribution maximizes spread and work plane brightness to optimize number ofluminaires neededLED/AREA: NEC/CEC, ATEX/IECEx ENCLOSED AND GASKETEDConfigurable OptionsMounting Brackets :Choose to mount yourRigmaster using one ofthese distinctly designedbrackets to best suit yourinstallation needs. Allbrackets can be factoryinstalled to save time inthe field or purchasedseparately.ERMLSB Large SwivelBracket:Can be used to tilt andaim the fixture up to 90degrees in incrementsof 15 degrees using thepre-notched lockingmechanismERMLPB Low ProfileBracket: This fixedposition bracket can beused to lower overallmounting profile in lowceiling applicationsWirenuts or Screw Terminal Blocks: Choose between wirenuts and screw terminal blocksto suit end user wiring preferences. Terminal blockssupport UL/CSA 22 to 12 AWG wireSafety FeaturesSafety Cables : can be purchasedseparately or included with fixture toreduce ordering and receiving complexityUp to four points for secondaryretention provide protection againstinfield vibration. Applicable to standard (non emergency) fixtures only. Brackets and safety cables can be ordered separately or included with fixture. See Ordering Table for more information. Mounting Brackets compatible with standard and emergency versions are not the same. please refer to mounting bracket details on page 9 for details.234Visit our website at www.emerson.com or contact us at (800) 621-1506. February 2021

Explosionproof Rigmaster LED Series LuminairesLinear LED fixture for hazardous environmentsNEC/CEC:Class I, Division 1, Groups C and DClass II, Division 1, Groups E, F, GClass IIIClass I Zone 1, Group IIBNEC/CEC:Type 3R, 4, 4X, IP66Simultaneous ExposureSuitable for Use in Wet LocationsNEC/CEC:Marine Outside Type (Salt Water) American Bureau of Shipping (ABS) Certified Order using catalog numbering guides below.ERMB42CCL(non-optic)CID1(standard)Appleton Bracket Separately)Color Temperature:B - Large Swivel BracketN - Neutral 4000KL - Low Profile BracketW - Warm 3000KWiring Method:Voltage :W - Wire Nuts (Standard)Lens Material:T - Terminal Blocks 125-300 VdcBH - 347-480 VacEmergency:Option :2 - 4,300 Lumens (2')C - Clear GlassN - If None (Standard)Blank - If None4 - 7,600 Lumens (4')F - Frosted Glass H - 90 minutes1 - (1) Safety CableE - 180 minutes2 - (2) Safety Cables Emergency battery back up version is only available with BU voltage configuration for 120-277Vac operation. For lumen output information, see Lumen Values Table. Brackets and safety cables can be ordered separately or included with fixture. See Ordering Table for more information. Applicable to standard (non emergency) fixtures only.Visit our website at www.emerson.com or contact us at (800) 621-1506. February 2021235LED/AREA: NEC/CEC, ATEX/IECEx ENCLOSED AND GASKETEDLumen (nominal) :2(Standard)BU - 120-277 Vac;C - Cool 5000KWColor:L - Linear Pattern2 - (4) 3/4" NPTLinear LEDMounting :N - If None (Use if OrderingGG - Appleton GrayPattern:1 - (4) 1/2" NPTRigmasterNLight DistributionHub Size:Series:ERM - ExplosionproofBU

Explosionproof Rigmaster LED Series LuminairesLinear LED fixture for hazardous environmentsNEC/CEC:Class I, Division 1, Groups C and DClass II, Division 1, Groups E, F, GClass IIIClass I Zone 1, Group IIBNEC/CEC:Type 3R, 4, 4X, IP66Simultaneous ExposureSuitable for Use in Wet LocationsNEC/CEC:Marine Outside Type (Salt Water) American Bureau of Shipping (ABS) Certified Lumen Values Table Lumen Output (Efficacy) for Clear Glass icacy5000K, 80 CRI, Clear Glass Lens431013375301364000K, 80 CRI, Clear Glass Lens412512872001303000K, 80 CRI, Clear Glass Lens40701267100128Lumen Output (Efficacy) for Frosted Glass LensLED/AREA: NEC/CEC, ATEX/IECEx ENCLOSED AND sEfficacy5000K CCT, 80 CRI, Frosted Glass Lens31909654901004000K CCT, 80 CRI, Frosted Glass Lens3080935310973000K CCT, 80 CRI, Frosted Glass Lens304092523095Lumen Output in Emergency Mode for Clear Glass LensConfiguration90 Minute180 Minute5000K CCT, 80 CRI13508004000K CCT, 80 CRI12607603000K CCT, 80 CRI1200720 All lumen values are typical (tolerance /- 10%) Applicable to standard (non emergency) fixtures only.236Visit our website at www.emerson.com or contact us at (800) 621-1506. February 2021

Explosionproof Rigmaster LED Series LuminairesLinear LED fixture for hazardous environmentsNEC/CEC:Class I, Division 1, Groups C and DClass II, Division 1, Groups E, F, GClass IIIClass I Zone 1, Group IIBNEC/CEC:Type 3R, 4, 4X, IP66Simultaneous ExposureSuitable for Use in Wet LocationsNEC/CEC:Marine Outside Type (Salt Water) American Bureau of Shipping (ABS) Certified Emergency Battery Backup Functionality - Automatic Testing System (ATS) FunctionalFull DurationStarts within 24 to 45 hours after the initial powerup of the moduleStarts within 5 to 26 days after the initial power of the moduleOccurs every 14 days after the initial aforementioned functional testOccurs every 364 days after the initial aforementioned functional testLasts for 30 secondsLasts for the full duration of the rated emergency periodAt the completion of functional and full duration tests, LED indicator will display the status of the emergency luminaire when AC is presentLED IndicatorLED IndicatorIndicator ColorTimingDescriptionGreen1 sec ON: 1 sec OFFNormal charging ok, Battery not yet fullycharged, No fault detected, Testing okGreen0.25 sec ON: 0.25 sec OFFFunctional / Duration Self-Test on-goingGreenSteady ONCharging ok, Battery fully charged, No faultdetected, Testing okRed1 sec ON: 1 sec OFFFault condition. Installation issue. Battery isreverse, not connected or shorted.Functional test failure, full durationtest failureLED Indicators OFF, LED Array ONLED Indicator Lights (Red and Green) OFFNo AC, Emergency mode ON Applicable to standard (non emergency) fixtures only.Visit our website at www.emerson.com or contact us at (800) 621-1506. February 2021237LED/AREA: NEC/CEC, ATEX/IECEx ENCLOSED AND GASKETEDLED Signals

Explosionproof Rigmaster LED Series LuminairesLinear LED fixture for hazardous environmentsNEC/CEC:Class I, Division 1, Groups C and DClass II, Division 1, Groups E, F, GClass IIIClass I Zone 1, Group IIBNEC/CEC:Type 3R, 4, 4X, IP66Simultaneous ExposureSuitable for Use in Wet LocationsNEC/CEC:Marine Outside Type (Salt Water) American Bureau of Shipping (ABS) Certified Electrical Ratings VoltageInput PowerInput Current (amp)Power FactorTHD120 Vac330.28 0.9 20277 Vac330.12 0.9 20125 Vdc330.27NANA300 Vdc330.11NANA347 Vac360.11 0.9 20480 Vac360.08 0.9 20120 Vac550.47 0.9 20277 Vac550.20 0.9 20125 Vdc550.44NANA300 Vdc550.18NANA347 Vac560.16 0.9 20480 Vac560.12 0.9 20VoltageInput PowerInput Current (amp)Power FactorTHD120 Vac390.35A 0.9 20277 Vac390.15A 0.9 20120 Vac600.57A 0.9 20277 Vac600.20A 0.9 20ModelBUERM*2BHLED/AREA: NEC/CEC, ATEX/IECEx ENCLOSED AND GASKETEDBUERM*4BHElectrical Ratings - Emergency Version BUModelERM*2BUERM*4 All values are typical (tolerance /-10%). Applicable to standard (non emergency) fixtures only.238Visit our website at www.emerson.com or contact us at (800) 621-1506. February 2021

Explosionproof Rigmaster LED Series LuminairesLinear LED fixture for hazardous environmentsNEC/CEC:Class I, Division 1, Groups C and DClass II, Division 1, Groups E, F, GClass IIIClass I Zone 1, Group IIBNEC/CEC:Type 3R, 4, 4X, IP66Simultaneous ExposureSuitable for Use in Wet LocationsNEC/CEC:Marine Outside Type (Salt Water) American Bureau of Shipping (ABS) Certified NEC/CEC Temperature Codes Class I, Division 1Groups C and DClass II, Division 1,Groups E, F and GSimultaneous Class IDivision 1 Groups C & Dand Class II Division 1Groups E,F & GT6T6T6T6T6T665 (149)T6T5T540 (104)T6T6T6T6T6T6T6T5T5AmbientTemperature C ( F)Supply wire Temperature C ( F)40 (104)55 (131)90 (194)55 (131)90 (194)65 (149)ModelERM*2ERM*4LED/AREA: NEC/CEC, ATEX/IECEx ENCLOSED AND GASKETEDNEC/CEC Temperature Codes - Emergency Version Class I, Division 1,Groups C & DClass II, Division 1,Group E,F & GSimultaneous ClassI Division 1 GroupsC & D and Class IIDivision 1 GroupsE,F & GT6T6T655(131)T6T6T640 (104)T6T6T6T6T6T6AmbientTemperature C ( F)Supply wireTemperature C ( F)40 (104)Model90 (194)ERM*290 (194)ERM*455(131)"T" Numbers Represent the Maximum Internal Temperature or Maximum Surface Temperature NEC/CEC"T" #Temp.Range C ( F)T1351- 450(664 842350326- 350(619 662)325301- 325(574 617)T2281- 300(538 572)T2A261- 280(448 500)T2BT2CT2D231216201- 260 - 230 - 215(448 - (421 - (394 500)446)419)T3181- 200(358 392)T3A166- 180(331 356)T3B161- 165(322 329)T3C136- 160(277 320)T4121- 135(250 275)T4A101- 120(214 248)T586 100(187 212)T685(185) Ambient Temperature Range: -40 C to 65 C (-40 F to 149 F). Ambient Temperature Range: -20 C to 55 C (-4 F to 131 F) T numbers represent the maximum internal temperature for Class I Division 1 and Class II Division 1 locations designated by the NEC. T numbers represent the maximum surface temperature under a dust blanket for Class II, Division 2 as designated by the NEC. Applicable to standard (non emergency) fixtures only.Visit our website at www.emerson.com or contact us at (800) 621-1506. February 2021239

Explosionproof Rigmaster LED Series LuminairesLinear LED fixture for hazardous environmentsNEC/CEC:Class I, Division 1, Groups C and DClass II, Division 1, Groups E, F, GClass IIIClass I Zone 1, Group IIBNEC/CEC:Type 3R, 4, 4X, IP66Simultaneous ExposureSuitable for Use in Wet LocationsNEC/CEC:Marine Outside Type (Salt Water) American Bureau of Shipping (ABS) Certified Standard Mounting BracketsDimensions mm (in)Weightkg (lbs)CatalogNumberLargeSwivelBracket1.5 (3.3)ERMLSBLowProfileBracket1.3 (2.8)ERMLPBDescription 331.58mm TYP.(13.5) 16mm TYP.(0.63)5.75mmTYP.(0.23)5mmTYP.(0.2)5mmTYP.(0.2) 87.47mm TYP(3.44) 180.18mm (7.09) 50.8mm TYP(2) 64.5mm TYP(2.54) 7mm TYP(0.28) 45mm (1.77) 9mm TYP.(0.35) 283mm TYP.(11.14) 165.5mm TYP.(6.52) 114.5mm TYP.(4.51) 87.47mm TYP.(3.44) 35mm (1.38) 14mm TYP.(0.55) 283mm TYP.(11.14) 165.5mm TYP.(6.52) 114.5mm TYP.(4.51) 14mm TYP.(0.55) R4.5 TYP.(0.18) 16mm TYP.(0.63) 9mm TYP(0.35) 35mm (1.38)161.04mm(6,34) 64.5mm TYP(2,54) 45mm (1,77) 7mm TYP(0,28) R5.75mmTYP.(0.23) 50.8mm TYP(2)LED/AREA: NEC/CEC, ATEX/IECEx ENCLOSED AND GASKETED 343.5mm TYP.(13.52) 331mm TYP.(13.03)R5mmTYP.(0.2) Applicable to standard (non emergency) fixtures only.240Visit our website at www.emerson.com or contact us at (800) 621-1506. February 2021

Explosionproof Rigmaster LED Series LuminairesLinear LED fixture for hazardous environmentsNEC/CEC:Class I, Division 1, Groups C and DClass II, Division 1, Groups E, F, GClass IIIClass I Zone 1, Group IIBNEC/CEC:Type 3R, 4, 4X, IP66Simultaneous ExposureSuitable for Use in Wet LocationsNEC/CEC:Marine Outside Type (Salt Water) American Bureau of Shipping (ABS) Certified Emergency Version Mounting BracketsDimensions mm (in)DescriptionWeightkg (lbs)CatalogNumberRigmasterEmergency1.8 (4.0) ERMHLSBSwivelBracket Applicable to standard (non emergency) fixtures only.Visit our website at www.emerson.com or contact us at (800) 621-1506. February 2021241LED/AREA: NEC/CEC, ATEX/IECEx ENCLOSED AND GASKETEDRigmasterEmergencyLow Profile 1.6 (3.5) ERMHLPBFixedBracket

Explosionproof Rigmaster LED Series LuminairesLinear LED fixture for hazardous environmentsNEC/CEC:Class I, Division 1, Groups C and DClass II, Division 1, Groups E, F, GClass IIIClass I Zone 1, Group IIBNEC/CEC:Type 3R, 4, 4X, IP66Simultaneous ExposureSuitable for Use in Wet LocationsNEC/CEC:Marine Outside Type (Salt Water) American Bureau of Shipping (ABS) Certified Mounting Bracket Selection Guide - Standard Version For customers trying to retrofit an existing fixture and match bolt patterns, use the table below as a guide to select the best bracket to suit your needsManufacturerPart NumberERMLSBLarge Swivel BracketERMLPBLow Profile BracketCrouse Hinds DP1057MTKXXLTXW4X—LSXW5—XAZZ Rig-A-Lite 53050X—Appleton AccessoriesGRFC75A junction boxX—Dialight Mounting Bracket Selection Guide - Emergency Version LED/AREA: NEC/CEC, ATEX/IECEx ENCLOSED AND GASKETEDFor customers trying to retrofit an existing fixture and match bolt patterns, use the table below as a guide to select the best bracket to suit your needsManufacturerPart NumberERMHLSB - EmergencySwivel BracketERMHLPB - EmergencyLow Profile BracketCrouse Hinds DP1057MTKXXLTXW4XXLSXW5XX53050X—Dialight AZZ Rig-A-Lite Accessories and Replacement PartsDescriptionCatalog NumbersStainless Steel Safety CablesLEDSC—Replacement BatteryManagement ModuleBPMLLED—Replacement Battery PackBMMRMSafety Cables The above information is strictly for guidance purposes and does not guarantee compatibility and fit. Please carefully review bolt patterns on each bracket toensure it meets your needs Applicable to standard (non emergency) fixtures only. Crouse-Hinds is a registered trademark of Eaton Corporation. Dialight is a registered trademark of Dialight. AZZ and Rig-A-Lite are registered trademarks of AZZ.242Visit our website at www.emerson.com or contact us at (800) 621-1506. February 2021

Explosionproof Rigmaster LED Series LuminairesLinear LED fixture for hazardous environmentsNEC/CEC:Class I, Division 1, Groups C and DClass II, Division 1, Groups E, F, GClass IIIClass I Zone 1, Group IIBNEC/CEC:Type 3R, 4, 4X, IP66Simultaneous ExposureSuitable for Use in Wet LocationsNEC/CEC:Marine Outside Type (Salt Water) American Bureau of Shipping (ABS) Certified Replacement DriversCatalog NumberVoltageConstant Current SettingsWattageLuminaire BH600 mA50WERM*2APM050C135UD104BU1040 mA50WERM*4APM050C135HD104BH1040 mA50WERM*4Replacement LensesLuminaire ModelQuantity per luminaireClearGlass LensERM*21ERM*42ERM*21ERM*42FrostedGlass LensCatalog NumberERMCLLED/AREA: NEC/CEC, ATEX/IECEx ENCLOSED AND GASKETEDDescriptionERMFL Applicable to standard (non emergency) fixtures only.Visit our website at www.emerson.com or contact us at (800) 621-1506. February 2021243

Explosionproof Rigmaster LED Series LuminairesLinear LED fixture for hazardous environmentsNEC/CEC:Class I, Division 1, Groups C and DClass II, Division 1, Groups E, F, GClass IIIClass I Zone 1, Group IIBNEC/CEC:Type 3R, 4, 4X, IP66Simultaneous ExposureSuitable for Use in Wet LocationsNEC/CEC:Marine Outside Type (Salt Water) American Bureau of Shipping (ABS) Certified Dimensions in Millimeters (Inches) 298 mm (11.7)117 mm(4.6)47 mm(1.8)156 mm(6.1) 249 mm (9.8)181 mm(7.1) 124 mm (4.9)181 mm(7.1) 572 mm (22.5)ERM*2 - Standard 298 mm (11.7)117 mm(4.6)47 mm(1.8)156 mm(6.1)181 mm(7.1)124 mm(4.9) 1149 mm (45.3)181 mm(7.1)LED/AREA: NEC/CEC, ATEX/IECEx ENCLOSED AND GASKETED 249 mm (9.8)ERM*4 - StandardProduct Weight and LengthModel #LumensWeight kg (lb)Length m (ft)ERM*243008.9 (19.6)0.57 (1.9)ERM*4760013.4 (29.5)1.15 (3.8)Note: weight of brackets are not included Applicable to standard (non emergency) fixtures only.244Visit our website at www.emerson.com or contact us at (800) 621-1506. February 2021

Explosionproof Rigmaster LED Series LuminairesLinear LED fixture for hazardous environmentsNEC/CEC:Class I, Division 1, Groups C and DClass II, Division 1, Groups E, F, GClass IIIClass I Zone 1, Group IIBNEC/CEC:Type 3R, 4, 4X, IP66Simultaneous ExposureSuitable for Use in Wet LocationsNEC/CEC:Marine Outside Type (Salt Water) American Bureau of Shipping (ABS) Certified Dimensions in Millimeters (Inches)ERM*2 - EmergencyLED/AREA: NEC/CEC, ATEX/IECEx ENCLOSED AND GASKETEDERM*4 - EmergencyProduct Weight and LengthModelWeight kg (lb)Length m (ft)ERM*2 - Emergency12.8 (28.2)0.57 (1.9)ERM*4 - Emergency18.4 (40.6)1.15 (3.8)Note: weight of brackets are provided separately Applicable to standard (non emergency) fixtures only.Visit our website at www.emerson.com or contact us at (800) 621-1506. February 2021245

Explosionproof Rigmaster LED Series LuminairesLinear LED fixture for hazardous environmentsNEC/CEC:Class I, Division 1, Groups C and DClass II, Division 1, Groups E, F, GClass IIIClass I Zone 1, Group IIBNEC/CEC:Type 3R, 4, 4X, IP66Simultaneous ExposureSuitable for Use in Wet LocationsNEC/CEC:Marine Outside Type (Salt Water) American Bureau of Shipping (ABS) Certified Photometric Data — DATA SHOWN IS ABSOLUTE2ft, Clear Glass Lens, 5000K CCTLuminaire Lumens 4325.5LED/AREA: NEC/CEC, ATEX/IECEx ENCLOSED AND GASKETEDPOLAR CANDELA DISTRIBUTIONISOFOOTCANDLE PLOTZONAL LUMEN 13.04,325.9% 49.6432.2665.1816.1859.6780.6478.8120.410.6LUMENS PER ZONE% 700.2%170-180% mens0.20.71.52.12.42.31.91.40.5% Total0%0%0%0%0.1%0.1%0%0%0%4ft, Clear Glass Lens, 5000K CCTLuminaire Lumens 7646.5POLAR CANDELA DISTRIBUTIONISOFOOTCANDLE PLOTZONAL LUMEN .118.47,646.5% 8.1LUMENS PER ZONE% 700.2%170-180% Lumens0.51.32.33.03.23.12.51.80.7% Total0%0%0%0%0%0%0%0%0% Applicable to standard (non emergency) fixtures only.246Visit our website at www.emerson.com or contact us at (800) 621-1506. February 2021

Explosionproof Rigmaster LED Series LuminairesLinear LED fixture for hazardous environmentsNEC/CEC:Class I, Division 1, Groups C and DClass II, Division 1, Groups E, F, GClass IIIClass I Zone 1, Group IIBNEC/CEC:Type 3R, 4, 4X, IP66Simultaneous ExposureSuitable for Use in Wet LocationsNEC/CEC:Marine Outside Type (Salt Water) American Bureau of Shipping (ABS) Certified Photometric Data — DATA SHOWN IS ABSOLUTE2ft Clear Glass Lens, 5000K CCT - 90 min Emergency ModeLuminaire Lumens 1287.4POLAR CANDELA DISTRIBUTIONISOFOOTCANDLE PLOTZONAL LUMEN 1287.4% ns45.3130.4199.9244.4256.2231.1140.334.82.8LUMENS PER ZONE% 700.2%170-180Lumens0.00.00.10.30.50.50.40.30.1% 0.10.0% Total0%0%0%0%0%0%0%0%0%4ft Clear Glass Lens, 5000K CCT - 90 min Emergency ModeLuminaire Lumens 1316.5POLAR CANDELA DISTRIBUTIONISOFOOTCANDLE PLOTZONAL LUMEN .5% S PER ZONE% 00.3%170-180 Applicable to standard (non emergency) fixtures only.Visit our website at www.emerson.com or contact us at (800) 621-1506. February 2021247LED/AREA: NEC/CEC, ATEX/IECEx ENCLOSED AND -180

Order using catalog numbering guides below. ERM B 4 2 C C L BU N G W 2 Series: ERM - Explosionproof Rigmaster Linear LED CID1 Hub Size: 1 - (4) 1/2" NPT 2 - (4) 3/4" NPT Light Distribution Pattern: L - Linear Pattern (non-optic) (standard) Color: G - Appleton Gray (Standard) Mounting : N - If None (Use if Ordering Appleton Bracket Separately)