Fibula Nail 2with Tip-LocTM TechnologyProduct Overview

Acumed Fibula Nail 2Designed in conjunction with Roy Sanders, MD, the Acumed Fibula Nail 2 is designed to addresssimple, transverse, and short oblique fractures as well as osteotomies of the fibula. The systemincludes three nail diameters and four length options, power reamers and carbon fiber radiolucenttargeting guides to streamline the procedure, threaded holes within the nail, headless hexalobescrews to help minimize soft-tissue irritation, and the option to lock the nail proximally, providingadditional fixation within the canal.The Fibula Nail 2 must be used in conjunction with the Acumed Fibula and Forearm Nail 2 BaseSet, which contains universal instrumentation to implant the Fibula Nail 2, Ulna Nail 2, and screws.

Low-Profile Screws3.5 mm headless hexalobe screws arelow-profile and are intended to minimizesoft-tissue irritationNail BendThe nail’s 5 degree bend is designedto accommodate the shape of theintramedullary canalTwo Lateral to Medial ScrewsBoth L/M screws are angled 8 degreessuperior to the joint space, and the mostproximal screw hole is threaded to createa locking construct to provide additionalfixation when desired. Both screwtrajectories can be used forsyndesmotic fixationFixed-Angle Screw HolesTwo threaded anterior to posteriorfixed-angle screw holesSystem FeaturesOptional Proximal FixationThe Tip-Loc Bushing and Set Screwoffer the option to lock the nail proximally,providing additional fixation within the canal

Comprehensive SystemThe Acumed Fibula Nail 2 includes 12 nails offered in 3 diameters and 4 lengths, 3.5 mm headless and nonlocking hexalobescrews, and the option to lock the nail proximally.2.6 mm Fibula Nail 2110 mm110 mm145 mmOptional End Caps3.6 mm Fibula Nail 2110 mm145 mm190 mmNote: All nail taildiameters are 6.35 mm3.0 mm Fibula Nail 2270 mm145 mm190 mm190 mm270 mm270 mmEnd caps assist in limiting ossification over the end of the nail, making the nail threadseasier to engage if removal is desired. End caps also allow for the creation of anintermediate nail length while adjusting for anatomic variances and screw trajectories.End Caps 0.4 mm 5 mm 10 mm 15 mm

ReamersReaming can be achieved under powerto optimize operative time, or by handif preferredScrew OptionsThe Fibula Nail 2 implants accept both3.5 mm Headless Hexalobe Screws and3.5 mm Nonlocking Hexalobe Screws.Headless screws lock into the threadedholes within the nail and are intended tocreate a low-profile construct aimed atminimizing soft-tissue irritationOptional Proximal FixationThe Tip-Loc Bushing and Set Screwoffer the option to lock the nailproximally, providing additional fixationwithin the canalSystem FeaturesUniversal InstrumentationThe Fibula Nail 2 is delivered in sterilepackaging and is designed to be used inconjunction with the Fibula and ForearmNail 2 Base Set. This set includes sharedinstrumentation to implant the Fibula Nail 2,Ulna Nail 2, and screws

6.5 mm drill used through a smallincision to create entry for the fibula nailShort (110 mm) nail to address simplefractures in the distal third of the fibulaIncision andEntry Point

X-Rays5 bend in the nail accommodates the shapeof the intramedullary canalMultiple threaded screw hole options

Preparation andPositioningFibula Nail 2SurgicalTechniqueIncision and EntryPointReaming and NailSelectionNail and Base PlateAssembly

Nail Insertion andScrew DrillingEnd Cap Placement(optional)Closure andPostoperative CareSurgical OverviewTargeting GuideAssembly

Our mission is to aid the afflicted through the ingenuity of ourminds, the labor of our hands, and the compassion of our hearts.

Acumed Headquarters5885 NE Cornelius Pass RoadHillsboro, OR 97124Office: 1.888.627.9957Office: 1.503.627.9957Fax: 1.503.520.9618www.acumed.netFNA00-04-B Effective: 2020/10 2020 Acumed LLCThese materials contain information about products that may or may not be available in any particular country or may beavailable under different trademarks in different countries. The products may be approved or cleared by governmentalregulatory organizations for sale or use with different indications or restrictions in different countries. Products may not beapproved for use in all countries. Nothing contained on these materials should be construed as a promotion or solicitationfor any product or for the use of any product in a particular way which is not authorized under the laws and regulationsof the country where the reader is located. Specific questions physicians may have about the availability and use ofthe products described on these materials should be directed to their particular authorized Acumed distributor. Specificquestions patients may have about the use of the products described in these materials or the appropriateness for theirown conditions should be directed to their own physician.Acumed , and Tip-Loc are registered trademarks of Acumed LLC